Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 41
Filtrar
1.
Int J Mol Sci ; 25(12)2024 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-38928493

RESUMO

The incorporation of histone variants has structural ramifications on nucleosome dynamics and stability. Due to their unique sequences, histone variants can alter histone-histone or histone-DNA interactions, impacting the folding of DNA around the histone octamer and the overall higher-order structure of chromatin fibers. These structural modifications alter chromatin compaction and accessibility of DNA by transcription factors and other regulatory proteins to influence gene regulatory processes such as DNA damage and repair, as well as transcriptional activation or repression. Histone variants can also generate a unique interactome composed of histone chaperones and chromatin remodeling complexes. Any of these perturbations can contribute to cellular plasticity and the progression of human diseases. Here, we focus on a frequently overlooked group of histone variants lying within the four human histone gene clusters and their contribution to breast cancer.


Assuntos
Neoplasias da Mama , Histonas , Humanos , Neoplasias da Mama/genética , Neoplasias da Mama/metabolismo , Neoplasias da Mama/patologia , Histonas/metabolismo , Histonas/genética , Feminino , Montagem e Desmontagem da Cromatina , Cromatina/metabolismo , Cromatina/genética , Nucleossomos/metabolismo , Família Multigênica
2.
bioRxiv ; 2024 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-38798454

RESUMO

Despite decades of research, acute myeloid leukemia (AML) remains a remarkably lethal malignancy. While pediatric AML (pAML) carries a more favorable prognosis than adult AML, the past 25 years of large clinical trials have produced few improvements in pAML survival. Nowhere is this more evident than in patients carrying a t(16;21)(p11;q22) translocation, which yields the FUS::ERG fusion transcript. Patients with FUS::ERG-positive AML are often primary refractory, and most responders quickly relapse. In COG clinical trials, allogeneic stem cell transplantation was of no benefit to FUS::ERG pAML patients; 100% of transplanted patients succumbed to their disease. Expression of major histocompatibility complex (MHC) class I & II and costimulatory molecules is absent at diagnosis in FUS::ERG AML, mirroring the epigenetic mechanism of post-transplant relapse seen in adult AML and its associated dismal outcomes. Here we show that this class-defining immune-repressive phenotype is driven by overexpression of the EZH2 histone lysine methyltransferase in vitro and in multiple clinical cohorts. We show that treatment with the FDA-approved EZH2 inhibitor tazemetostat along with IFN-γ reverses this phenotype, re-establishes MHC presentation, and severely impairs the viability of FUS::ERG AML cells. EZH2 inhibitors may thus provide the first targeted therapeutic option for patients with this high-risk subtype of pAML, with particular benefit as a bridge to successful allogeneic stem cell transplantation.

3.
Environ Pollut ; 347: 123586, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38467368

RESUMO

Inorganic arsenic (iAs) causes cancer by initiating dynamic transitions between epithelial and mesenchymal cell phenotypes. These transitions transform normal cells into cancerous cells, and cancerous cells into metastatic cells. Most in vitro models assume that transitions between states are binary and complete, and do not consider the possibility that intermediate, stable cellular states might exist. In this paper, we describe a new, two-hit in vitro model of iAs-induced carcinogenesis that extends to 28 weeks of iAs exposure. Through week 17, the model faithfully recapitulates known and expected phenotypic, genetic, and epigenetic characteristics of iAs-induced carcinogenesis. By 28 weeks, however, exposed cells exhibit stable, intermediate phenotypes and epigenetic properties, and key transcription factor promoters (SNAI1, ZEB1) enter an epigenetically poised or bivalent state. These data suggest that key epigenetic transitions and cellular states exist during iAs-induced epithelial-to-mesenchymal transition (EMT), and that it is important for our in vitro models to encapsulate all aspects of EMT and the mesenchymal-to-epithelial transition (MET). In so doing, and by understanding the epigenetic systems controlling these transitions, we might find new, unexpected opportunities for developing targeted, cell state-specific therapeutics.


Assuntos
Arsênio , Neoplasias , Humanos , Arsênio/toxicidade , Fatores de Transcrição/metabolismo , Epigênese Genética , Carcinogênese/induzido quimicamente
4.
bioRxiv ; 2023 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-37745326

RESUMO

DNA mutations are necessary drivers of cancer, yet only a small subset of mutated cells go on to cause the disease. To date, the mechanisms that determine which rare subset of cells transform and initiate tumorigenesis remain unclear. Here, we take advantage of a unique model of intrinsic developmental heterogeneity (Trim28+/D9) and demonstrate that stochastic early life epigenetic variation can trigger distinct cancer-susceptibility 'states' in adulthood. We show that these developmentally primed states are characterized by differential methylation patterns at typically silenced heterochromatin, and that these epigenetic signatures are detectable as early as 10 days of age. The differentially methylated loci are enriched for genes with known oncogenic potential. These same genes are frequently mutated in human cancers, and their dysregulation correlates with poor prognosis. These results provide proof-of-concept that intrinsic developmental heterogeneity can prime individual, life-long cancer risk.

5.
Nat Metab ; 4(9): 1150-1165, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-36097183

RESUMO

Studies in genetically 'identical' individuals indicate that as much as 50% of complex trait variation cannot be traced to genetics or to the environment. The mechanisms that generate this 'unexplained' phenotypic variation (UPV) remain largely unknown. Here, we identify neuronatin (NNAT) as a conserved factor that buffers against UPV. We find that Nnat deficiency in isogenic mice triggers the emergence of a bi-stable polyphenism, where littermates emerge into adulthood either 'normal' or 'overgrown'. Mechanistically, this is mediated by an insulin-dependent overgrowth that arises from histone deacetylase (HDAC)-dependent ß-cell hyperproliferation. A multi-dimensional analysis of monozygotic twin discordance reveals the existence of two patterns of human UPV, one of which (Type B) phenocopies the NNAT-buffered polyphenism identified in mice. Specifically, Type-B monozygotic co-twins exhibit coordinated increases in fat and lean mass across the body; decreased NNAT expression; increased HDAC-responsive gene signatures; and clinical outcomes linked to insulinemia. Critically, the Type-B UPV signature stratifies both childhood and adult cohorts into four metabolic states, including two phenotypically and molecularly distinct types of obesity.


Assuntos
Proteínas de Membrana , Proteínas do Tecido Nervoso , Adaptação Fisiológica , Adulto , Animais , Criança , Histona Desacetilases , Humanos , Insulina , Proteínas de Membrana/metabolismo , Camundongos , Proteínas do Tecido Nervoso/genética , Obesidade/genética , Obesidade/metabolismo
6.
Anal Chem ; 92(7): 5311-5318, 2020 04 07.
Artigo em Inglês | MEDLINE | ID: mdl-32142258

RESUMO

Automated genotyping of drug-resistant Mycobacterium tuberculosis (MTB) directly from sputum is challenging for three primary reasons. First, the sample matrix, sputum, is highly viscous and heterogeneous, posing a challenge for sample processing. Second, acid-fast MTB bacilli are difficult to lyse. And third, there are hundreds of MTB mutations that confer drug resistance. An additional constraint is that MTB is most prevalent where test affordability is paramount. We address the challenge of sample homogenization and cell lysis using magnetic rotation of an external magnet, at high (5000) rpm, to induce the rotation of a disposable stir disc that causes chaotic mixing of glass beads ("MagVor"). Nucleic acid is purified using a pipet tip with an embedded matrix that isolates nucleic acid ("TruTip"). We address the challenge of cost and genotyping multiple mutations using 203 porous three-dimensional gel elements printed on a film substrate and enclosed in a microfluidic laminate assembly ("Lab-on-a-Film"). This Lab-on-a-Film assembly (LFA) serves as a platform for amplification, hybridization, washing, and fluorescent imaging, while maintaining a closed format to prevent amplicon contamination of the workspace. We integrated and automated MagVor homogenization, TruTip purification, and LFA amplification in a multisample, sputum-to-genotype system. Using this system, we report detection down to 43 cfu/mL of MTB bacilli from raw sputum.


Assuntos
Automação , Dispositivos Lab-On-A-Chip , Mycobacterium tuberculosis/genética , Imagem Óptica , Escarro/microbiologia , Tuberculose Resistente a Múltiplos Medicamentos/diagnóstico por imagem , Genótipo , Humanos , Imagem Óptica/instrumentação
8.
Lab Chip ; 19(7): 1217-1225, 2019 03 27.
Artigo em Inglês | MEDLINE | ID: mdl-30801596

RESUMO

We describe a Lab-on-a-Film disposable that detects multidrug-resistant tuberculosis (MDR-TB) from sputum extracts. The Lab-on-a-Film disposable consists of 203 gel elements that include DNA sequences (probes) for 37 mutations, deletions, or insertion elements across 5 genes (including an internal control). These gel elements are printed on a flexible film, which costs approximately 500 times less than microarray glass. The film with printed gel elements is then laminated to additional rollable materials (films) to form a microfluidic flow cell. We combined multiplex amplification and hybridization steps in a single microfluidic chamber, without buffer exchanges or other manipulations up to and throughout hybridization. This flow cell also incorporates post hybridization wash steps while retaining an entirely closed-amplicon system, thus minimizing the potential for sample or amplicon cross-contamination. We report analytical sensitivity of 32 cfu mL-1 across all MDR-TB markers and detection of MDR-TB positive clinical specimens using an automated TruTip workstation for extraction and the Lab-on-a-Film disposable for amplification and detection of the extracts.


Assuntos
Equipamentos Descartáveis , Resistência a Múltiplos Medicamentos/genética , Técnicas de Genotipagem/instrumentação , Mycobacterium tuberculosis/efeitos dos fármacos , Mycobacterium tuberculosis/genética , Escarro/microbiologia , Humanos
9.
PLoS One ; 13(7): e0199869, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29975759

RESUMO

Automated nucleic acid extraction from primary (raw) sputum continues to be a significant technical challenge for molecular diagnostics. In this work, we developed a prototype open-architecture, automated nucleic acid workstation that includes a mechanical homogenization and lysis function integrated with heating and TruTip purification; optimized an extraction protocol for raw sputum; and evaluated system performance on primary clinical specimens. Eight samples could be processed within 70 min. The system efficiently homogenized primary sputa and doubled nucleic acid recovery relative to an automated protocol that did not incorporate sample homogenization. Nucleic acid recovery was at least five times higher from raw sputum as compared to that of matched sediments regardless of smear or culture grade, and the automated workstation reproducibly recovered PCR-detectable DNA to at least 80 CFU mL-1 raw sputum. M. tuberculosis DNA was recovered and detected from 122/123 (99.2%) and 124/124 (100%) primary sputum and sediment extracts, respectively. There was no detectable cross-contamination across 53 automated system runs and amplification or fluorescent inhibitors (if present) were not detectable. The open fluidic architecture of the prototype automated workstation yields purified sputum DNA that can be used for any molecular diagnostic test. The ability to transfer TruTip protocols between personalized, on-demand pipetting tools and the fully automated workstation also affords public health agencies an opportunity to standardize sputum nucleic acid sample preparation procedures, reagents, and quality control across multiple levels of the health care system.


Assuntos
DNA Bacteriano/genética , DNA Bacteriano/isolamento & purificação , Mycobacterium tuberculosis/genética , Manejo de Espécimes/métodos , Escarro/microbiologia , Tuberculose/diagnóstico , Tuberculose/microbiologia , Automação Laboratorial , Humanos , Mycobacterium tuberculosis/isolamento & purificação , Técnicas de Amplificação de Ácido Nucleico
10.
J Microbiol Methods ; 148: 174-180, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29678500

RESUMO

Systems that automate extraction of nucleic acid from cells or viruses in complex clinical matrices have tremendous value even in the absence of an integrated downstream detector. We describe our bench-top automated workstation that integrates our previously-reported extraction method - TruTip - with our newly-developed mechanical lysis method. This is the first report of this method for homogenizing viscous and heterogeneous samples and lysing difficult-to-disrupt cells using "MagVor": a rotating magnet that rotates a miniature stir disk amidst glass beads confined inside of a disposable tube. Using this system, we demonstrate automated nucleic acid extraction from methicillin-resistant Staphylococcus aureus (MRSA) in nasopharyngeal aspirate (NPA), influenza A in nasopharyngeal swabs (NPS), human genomic DNA from whole blood, and Mycobacterium tuberculosis in NPA. The automated workstation yields nucleic acid with comparable extraction efficiency to manual protocols, which include commercially-available Qiagen spin column kits, across each of these sample types. This work expands the scope of applications beyond previous reports of TruTip to include difficult-to-disrupt cell types and automates the process, including a method for removal of organics, inside a compact bench-top workstation.


Assuntos
Automação Laboratorial/instrumentação , Automação Laboratorial/métodos , Técnicas de Diagnóstico Molecular/instrumentação , Técnicas de Diagnóstico Molecular/métodos , Ácidos Nucleicos/isolamento & purificação , Manejo de Espécimes/instrumentação , Manejo de Espécimes/métodos , Células Sanguíneas/química , Misturas Complexas/isolamento & purificação , Humanos , Vírus da Influenza A/química , Staphylococcus aureus Resistente à Meticilina/química , Mycobacterium tuberculosis/química
11.
J Clin Microbiol ; 56(3)2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29305543

RESUMO

There is a growing awareness that molecular diagnostics for detect-to-treat applications will soon need a highly multiplexed mutation detection and identification capability. In this study, we converted an open-amplicon microarray hybridization test for multidrug-resistant (MDR) Mycobacterium tuberculosis into an entirely closed-amplicon consumable (an amplification microarray) and evaluated its performance with matched sputum and sediment extracts. Reproducible genotyping (the limit of detection) was achieved with ∼25 M. tuberculosis genomes (100 fg of M. tuberculosis DNA) per reaction; the estimated shelf life of the test was at least 18 months when it was stored at 4°C. The test detected M. tuberculosis in 99.1% of sputum extracts and 100% of sediment extracts and showed 100% concordance with the results of real-time PCR. The levels of concordance between M. tuberculosis and resistance-associated gene detection were 99.1% and 98.4% for sputum and sediment extracts, respectively. Genotyping results were 100% concordant between sputum and sediment extracts. Relative to the results of culture-based drug susceptibility testing, the test was 97.1% specific and 75.0% sensitive for the detection of rifampin resistance in both sputum and sediment extracts. The specificity for the detection of isoniazid (INH) resistance was 98.4% and 96.8% for sputum and sediment extracts, respectively, and the sensitivity for the detection of INH resistance was 63.6%. The amplification microarray reported the correct genotype for all discordant phenotype/genotype results. On the basis of these data, primary sputum may be considered a preferred specimen for the test. The amplification microarray design, shelf life, and analytical performance metrics are well aligned with consensus product profiles for next-generation drug-resistant M. tuberculosis diagnostics and represent a significant ease-of-use advantage over other hybridization-based tests for diagnosing MDR tuberculosis.


Assuntos
Técnicas de Genotipagem/métodos , Sedimentos Geológicos/microbiologia , Mycobacterium tuberculosis/genética , Análise de Sequência com Séries de Oligonucleotídeos , Escarro/microbiologia , Tuberculose Resistente a Múltiplos Medicamentos/diagnóstico , Antituberculosos/farmacologia , Farmacorresistência Bacteriana Múltipla/genética , Genes MDR/genética , Genótipo , Humanos , Isoniazida/farmacologia , Testes de Sensibilidade Microbiana , Técnicas Analíticas Microfluídicas , Mycobacterium tuberculosis/efeitos dos fármacos , Mycobacterium tuberculosis/isolamento & purificação , Rifampina/farmacologia , Sensibilidade e Especificidade
12.
J Virol Methods ; 208: 152-9, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25066276

RESUMO

The objectives of this study were to develop a user-friendly, gel element microarray test for influenza virus detection, subtyping, and neuraminidase inhibitor resistance detection, assess the performance characteristics of the assay, and perform a clinical evaluation on retrospective nasopharyngeal swab specimens. A streamlined microarray workflow enabled a single user to run up to 24 tests in an 8h shift. The most sensitive components of the test were the primers and probes targeting the A/H1 pdm09 HA gene with an analytical limit of detection (LoD) <100 gene copies (gc) per reaction. LoDs for all targets in nasopharyngeal swab samples were ≤1000 gc, with the exception of one target in the seasonal A/H1N1 subtype. Seasonal H275Y variants were detectable in a mixed population when present at >5% with wild type virus, while the 2009 pandemic H1N1 H275Y variant was detectable at ≤1% in a mixture with pandemic wild type virus. Influenza typing and subtyping results concurred with those obtained with real-time RT-PCR assays on more than 97% of the samples tested. The results demonstrate that a large panel of single-plex, real-time RT-PCR tests can be translated to an easy-to-use, sensitive, and specific microarray test for potential diagnostic use.


Assuntos
Farmacorresistência Viral , Vírus da Influenza A Subtipo H1N1/classificação , Vírus da Influenza A Subtipo H1N1/isolamento & purificação , Análise em Microsséries/métodos , Técnicas de Diagnóstico Molecular/métodos , Neuraminidase/genética , Proteínas Virais/genética , Antivirais/farmacologia , Humanos , Vírus da Influenza A Subtipo H1N1/efeitos dos fármacos , Vírus da Influenza A Subtipo H1N1/genética , Laboratórios , Tipagem Molecular/métodos , Proteínas Mutantes/genética , Nasofaringe/virologia , Oseltamivir/farmacologia , Estudos Retrospectivos , Sensibilidade e Especificidade , Fatores de Tempo , Recursos Humanos
13.
J Vis Exp ; (86)2014 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-24796567

RESUMO

Simplifying microarray workflow is a necessary first step for creating MDR-TB microarray-based diagnostics that can be routinely used in lower-resource environments. An amplification microarray combines asymmetric PCR amplification, target size selection, target labeling, and microarray hybridization within a single solution and into a single microfluidic chamber. A batch processing method is demonstrated with a 9-plex asymmetric master mix and low-density gel element microarray for genotyping multi-drug resistant Mycobacterium tuberculosis (MDR-TB). The protocol described here can be completed in 6 hr and provide correct genotyping with at least 1,000 cell equivalents of genomic DNA. Incorporating on-chip wash steps is feasible, which will result in an entirely closed amplicon method and system. The extent of multiplexing with an amplification microarray is ultimately constrained by the number of primer pairs that can be combined into a single master mix and still achieve desired sensitivity and specificity performance metrics, rather than the number of probes that are immobilized on the array. Likewise, the total analysis time can be shortened or lengthened depending on the specific intended use, research question, and desired limits of detection. Nevertheless, the general approach significantly streamlines microarray workflow for the end user by reducing the number of manually intensive and time-consuming processing steps, and provides a simplified biochemical and microfluidic path for translating microarray-based diagnostics into routine clinical practice.


Assuntos
Mycobacterium tuberculosis/efeitos dos fármacos , Mycobacterium tuberculosis/genética , Reação em Cadeia da Polimerase/métodos , Farmacorresistência Bacteriana Múltipla , Tuberculose/microbiologia
14.
J Clin Microbiol ; 52(6): 2100-7, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24719444

RESUMO

We developed a simplified microarray test for detecting and identifying mutations in rpoB, katG, inhA, embB, and rpsL and compared the analytical performance of the test to that of phenotypic drug susceptibility testing (DST). The analytical sensitivity was estimated to be at least 110 genome copies per amplification reaction. The microarray test correctly detected 95.2% of mutations for which there was a sequence-specific probe on the microarray and 100% of 96 wild-type sequences. In a blinded analysis of 153 clinical isolates, microarray sensitivity for first-line drugs relative to phenotypic DST (true resistance) was 100% for rifampin (RIF) (14/14), 90.0% for isoniazid (INH) (36/40), 70% for ethambutol (EMB) (7/10), and 89.1% (57/64) combined. Microarray specificity (true susceptibility) for first-line agents was 95.0% for RIF (132/139), 98.2% for INH (111/113), and 98.6% for EMB (141/143). Overall microarray specificity for RIF, INH, and EMB combined was 97.2% (384/395). The overall positive and negative predictive values for RIF, INH, and EMB combined were 84.9% and 98.3%, respectively. For the second-line drug streptomycin (STR), overall concordance between the agar proportion method and microarray analysis was 89.5% (137/153). Sensitivity was 34.8% (8/23) because of limited microarray coverage for STR-conferring mutations, and specificity was 99.2% (129/130). All false-susceptible discrepant results were a consequence of DNA mutations that are not represented by a specific microarray probe. There were zero invalid results from 220 total tests. The simplified microarray system is suitable for detecting resistance-conferring mutations in clinical M. tuberculosis isolates and can now be used for prospective trials or integrated into an all-in-one, closed-amplicon consumable.


Assuntos
Antituberculosos/farmacologia , Farmacorresistência Bacteriana , Técnicas de Genotipagem/métodos , Análise em Microsséries/métodos , Mycobacterium tuberculosis/efeitos dos fármacos , Mycobacterium tuberculosis/genética , Tuberculose Resistente a Múltiplos Medicamentos/diagnóstico , Genes Bacterianos , Humanos , Testes de Sensibilidade Microbiana/métodos , Mutação , Sensibilidade e Especificidade
15.
J Clin Virol ; 58(1): 138-43, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23880159

RESUMO

BACKGROUND: Rapid, simple and efficient influenza RNA purification from clinical samples is essential for sensitive molecular detection of influenza infection. Automation of the TruTip extraction method can increase sample throughput while maintaining performance. OBJECTIVES: To automate TruTip influenza RNA extraction using an Eppendorf epMotion robotic liquid handler, and to compare its performance to the bioMerieux easyMAG and Qiagen QIAcube instruments. STUDY DESIGN: Extraction efficacy and reproducibility of the automated TruTip/epMotion protocol was assessed from influenza-negative respiratory samples spiked with influenza A and B viruses. Clinical extraction performance from 170 influenza A and B-positive respiratory swabs was also evaluated and compared using influenza A and B real-time RT-PCR assays. RESULTS: TruTip/epMotion extraction efficacy was 100% in influenza virus-spiked samples with at least 745 influenza A and 370 influenza B input gene copies per extraction, and exhibited high reproducibility over four log10 concentrations of virus (<1% CV). RNA yields between the three automated methods differed by less than 0.5 log10 gene copies. 99% of clinical specimens that were PCR-positive after easyMAG or QIAcube extraction were also positive following TruTip extraction. Overall Ct value differences obtained between TruTip/epMotion and easyMAG/QIAcube clinical extracts ranged from 1.24 to 1.91. Pairwise comparisons of Ct values showed a high correlation of the TruTip/epMotion protocol to the other methods (R2>0.90). CONCLUSION: The automated TruTip/epMotion protocol is a simple and rapid extraction method that reproducibly purifies influenza RNA from respiratory swabs, with comparable efficacy and efficiency to both the easyMAG and QIAcube instruments.


Assuntos
Automação Laboratorial/métodos , Influenza Humana/diagnóstico , Orthomyxoviridae/genética , RNA Viral/isolamento & purificação , Sistema Respiratório/virologia , Manejo de Espécimes/métodos , Humanos , Orthomyxoviridae/isolamento & purificação , RNA Viral/genética , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Fatores de Tempo
16.
J Vis Exp ; (76): e50356, 2013 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-23793016

RESUMO

TruTip is a simple nucleic acid extraction technology whereby a porous, monolithic binding matrix is inserted into a pipette tip. The geometry of the monolith can be adapted for specific pipette tips ranging in volume from 1.0 to 5.0 ml. The large porosity of the monolith enables viscous or complex samples to readily pass through it with minimal fluidic backpressure. Bi-directional flow maximizes residence time between the monolith and sample, and enables large sample volumes to be processed within a single TruTip. The fundamental steps, irrespective of sample volume or TruTip geometry, include cell lysis, nucleic acid binding to the inner pores of the TruTip monolith, washing away unbound sample components and lysis buffers, and eluting purified and concentrated nucleic acids into an appropriate buffer. The attributes and adaptability of TruTip are demonstrated in three automated clinical sample processing protocols using an Eppendorf epMotion 5070, Hamilton STAR and STARplus liquid handling robots, including RNA isolation from nasopharyngeal aspirate, genomic DNA isolation from whole blood, and fetal DNA extraction and enrichment from large volumes of maternal plasma (respectively).


Assuntos
DNA/isolamento & purificação , Ensaios de Triagem em Larga Escala/métodos , RNA/isolamento & purificação , DNA/sangue , Feminino , Ensaios de Triagem em Larga Escala/instrumentação , Humanos , Masculino , Líquido da Lavagem Nasal/química , Nasofaringe/metabolismo , RNA/sangue , Robótica/instrumentação , Robótica/métodos
17.
Appl Environ Microbiol ; 79(3): 799-807, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23160129

RESUMO

The objectives of this study were to unify amplification, labeling, and microarray hybridization chemistries within a single, closed microfluidic chamber (an amplification microarray) and verify technology performance on a series of groundwater samples from an in situ field experiment designed to compare U(VI) mobility under conditions of various alkalinities (as HCO(3)(-)) during stimulated microbial activity accompanying acetate amendment. Analytical limits of detection were between 2 and 200 cell equivalents of purified DNA. Amplification microarray signatures were well correlated with 16S rRNA-targeted quantitative PCR results and hybridization microarray signatures. The succession of the microbial community was evident with and consistent between the two microarray platforms. Amplification microarray analysis of acetate-treated groundwater showed elevated levels of iron-reducing bacteria (Flexibacter, Geobacter, Rhodoferax, and Shewanella) relative to the average background profile, as expected. Identical molecular signatures were evident in the transect treated with acetate plus NaHCO(3), but at much lower signal intensities and with a much more rapid decline (to nondetection). Azoarcus, Thaurea, and Methylobacterium were responsive in the acetate-only transect but not in the presence of bicarbonate. Observed differences in microbial community composition or response to bicarbonate amendment likely had an effect on measured rates of U reduction, with higher rates probable in the part of the field experiment that was amended with bicarbonate. The simplification in microarray-based work flow is a significant technological advance toward entirely closed-amplicon microarray-based tests and is generally extensible to any number of environmental monitoring applications.


Assuntos
Bactérias/classificação , Bactérias/genética , Biota , Água Subterrânea/microbiologia , Metagenômica/métodos , Análise em Microsséries/métodos , Acetatos/metabolismo , DNA Bacteriano/genética , RNA Ribossômico 16S/genética , Sensibilidade e Especificidade , Bicarbonato de Sódio/metabolismo
18.
J Microbiol Methods ; 91(3): 366-76, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23041495

RESUMO

Detection of methicillin-resistant Staphylococcus aureus (MRSA) is important for prevention and control of MRSA infections, but the discovery of mecA dropouts and SCCmec junction sequences with homology to coagulase-negative staphylococci (CoNS) has challenged several real-time PCR tests. The objective of this study was to develop a user-friendly, gel element microarray test for MRSA detection, to estimate the analytical performance characteristics of the test on bacterial isolates, and to perform an initial evaluation of the test on nasopharyngeal swabs from patients known to have a high prevalence of S. aureus containing mecA dropouts. The assay limit of detection for the test was 250 fg (or less) of genomic DNA per amplification reaction (approximately 80 cell equivalents) and MRSA was consistently detected at a ratio of 1:12,000 in a non-target background. Of 87 bacterial isolates, the test accurately classified 86 (98.8%) overall, and correctly identified 14 mecA dropout specimens that were falsely positive in the BD GeneOhm MRSA test or BD GeneOhm StaphSR test. A retrospective analysis of 246 nasal swab samples acquired from a high-risk patient population (overall prevalence=10.8% by culture) resulted in 80.5% sensitivity (95% CI=68.4%, 92.6%) and 96.6% specificity. Of these 246 samples, 174 (71%) were positive for mecA, 86 (35%) were positive for S. aureus tufA and 46 (19%) were positive for a SCCmec junction sequence. To estimate method repeatability, 48 samples representing the full range of phenotypes, genotypes and microarray probe SNR values were tested in triplicate, with three discordant results for a concordance rate of 97.9% (141/144 tests). These data demonstrate that a very simple microarray test can identify mecA dropouts with high specificity in either cultured isolates or nasal swabs from a high-prevalence, high-risk patient population. However, the clinical sensitivity of the test will likely depend on local microbial ecology and the prevalence of mecA positive CoNS in any given patient population.


Assuntos
Proteínas de Bactérias/genética , Staphylococcus aureus Resistente à Meticilina/isolamento & purificação , Mucosa Nasal/microbiologia , Análise de Sequência com Séries de Oligonucleotídeos/métodos , Infecções Estafilocócicas/microbiologia , Humanos , Staphylococcus aureus Resistente à Meticilina/classificação , Staphylococcus aureus Resistente à Meticilina/genética , Staphylococcus aureus Resistente à Meticilina/metabolismo , Muco/metabolismo , Muco/microbiologia , Mucosa Nasal/metabolismo , Proteínas de Ligação às Penicilinas , Estudos Retrospectivos , Sensibilidade e Especificidade
19.
J Virol Methods ; 183(1): 8-13, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22425698

RESUMO

This report describes the development and pre-clinical testing of a new, random-access RNA sample preparation system (TruTip) for nasopharyngeal samples. The system is based on a monolithic, porous nucleic acid binding matrix embedded within an aerosol-resistant pipette tip and can be operated with single or multi-channel pipettors. Equivalent extraction efficiencies were obtained between automated QIAcube and manual TruTip methods at 10(6) gene copies influenza A per mL nasopharyngeal aspirate. Influenza A and B amended into nasopharyngeal swabs (in viral transport medium) were detected by real-time RT-PCR at approximately 745 and 370 gene copies per extraction, respectively. RNA extraction efficiency in nasopharyngeal swabs was also comparable to that obtained on an automated QIAcube instrument over a range of input concentrations; the correlation between threshold cycles (or nucleic acid recovery) for TruTip and QIAcube-purified RNA was R(2)>0.99. Preclinical testing of TruTip on blinded nasopharyngeal swab samples resulted in 98% detection accuracy relative to a clinically validated easyMAG extraction method. The physical properties of the TruTip binding matrix and ability to customize its shape and dimensions likewise make it amenable to automation and/or fluidic integration.


Assuntos
Vírus da Influenza A/genética , Vírus da Influenza B/genética , Nasofaringe/virologia , RNA Viral/isolamento & purificação , Manejo de Espécimes/métodos , Virologia/métodos , Animais , Humanos
20.
Anal Biochem ; 421(2): 526-33, 2012 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-22033291

RESUMO

By modifying polymer compositions and cross-linking reagents, we have developed a simple yet effective manufacturing strategy for copolymerized three-dimensional gel element arrays. A new gel-forming monomer, 2-(hydroxyethyl) methacrylamide (HEMAA), was used. HEMAA possesses low volatility and improves the stability of copolymerized gel element arrays to on-chip thermal cycling procedures relative to previously used monomers. Probe immobilization efficiency within the new polymer was 55%, equivalent to that obtained with acrylamide (AA) and methacrylamide (MA) monomers. Nonspecific binding of single-stranded targets was equivalent for all monomers. Increasing cross-linker chain length improved hybridization kinetics and end-point signal intensities relative to N,N-methylenebisacrylamide (Bis). The new copolymer formulation was successfully applied to a model orthopox array. Because HEMAA greatly simplifies gel element array manufacture, we expect it (in combination with new cross-linkers described here) to find widespread application in microarray science.


Assuntos
Géis , Metacrilatos/química , Análise de Sequência com Séries de Oligonucleotídeos , Sequência de Bases , Cinética , Sondas de Oligonucleotídeos , Reação em Cadeia da Polimerase , Volatilização
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...