Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Heliyon ; 10(7): e27971, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38623195

RESUMO

Background: Although the conventional replacement for lost teeth has been partial or full dentures, the need for a fixed, esthetic, and functional restoration makes dental implants a reliable alternative. Aim: To evaluate the initial and final stability of platelet rich fibrin coated implants using resonance frequency analyzer. Method: ology: Thirteen patients with two or more missing teeth were informed about the procedure, and a consent form was obtained after cone beam computer tomography evaluation. Blood was drawn from the anticubital area of the patient, which was centrifuged to obtain platelet-rich fibrin. In all, 26 implants were placed, among which 13 were platelet-rich fibrin-coated (test group) and 13 were without platelet-rich fibrin (control group), and implant stability quotient values were recorded. Results: The mean age of the patients was 34.4 (SD = 4.28). Majority of the patients were males (9; 69.2%) whereas there were only four (30.8%) female patients. When comparison between overall primary implant stability with and without PRF was done, the mean difference was 5.12 and this difference was not statistically significant (p = 0.221) whereas a statistically significant difference (p = 0.019) was found when comparison between overall secondary implant stability was done with and without PRF. The primary and secondary stability values for the control group were 69.18 ± 7.45 and 73.84 ± 8.21 respectively, and the primary and secondary stability values for the test group were 64.06 ± 12.66 and 81.49 ± 7.61 respectively, which showed statistically significant differences among the groups. The difference in these values signify that primary stability is more in control group whereas secondary stability is more in case group. This signifies that PRF enhances the stability of implant. Conclusion: Implants coated with platelet-rich fibrin exhibited better osseointegration than implants without platelet-rich fibrin.

2.
Indian J Otolaryngol Head Neck Surg ; 60(4): 379-81, 2008 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23120587

RESUMO

Atrophic rhinitis is a form of chronic rhinitis in which the nasal mucosa atrophies and hardens, causing the nasal passages to dilate and dry out. Other prominent findings include bad smell, extensive nasal crusting and bleeding. Surgical and nonsurgical methods have been advocated for its treatment. We describe a prosthetic technique for its management.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...