Static mixers may be used to dissolve gaseous ozone in water treatment facilities in order to provide protection against the waterborne parasite Cryptosporidium parvum. The objective of this study was to determine the effect of a brief exposure to turbulent gas-liquid mixing conditions in a static mixer on inactivation of C. parvum oocysts by ozone. Inactivation measured in an ozone contacting apparatus that employed a static mixer for ozone dissolution was compared to predictions based on a previously published kinetic model of C. parvum inactivation by dissolved ozone in gently stirred batch reactors. Although initial contact in the static mixer had no immediate effect on the oocysts, a 20% increase in the rate of inactivation during subsequent contact with dissolved ozone was observed. Increasing the degree of turbulence within the static mixer did not yield additional inactivation. Use of static mixers for dissolution of ozone in drinking water treatment systems may provide limited enhancement of C. parvum inactivation by dissolved ozone.