Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 30
Filtrar
1.
Bone ; 130: 115100, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31678491

RESUMO

It is estimated that over 200 million people worldwide are affected by osteoporosis. Vertebral fracture risk prediction using dual energy x-ray absorptiometry (DXA) is confounded by limitations of the technology, such as 2D measurements of bone mineral density (BMD), inability to measure bone distribution and heterogeneity, and potential overestimations of BMD due to degenerative diseases. To overcome these shortcomings, single energy (SE) quantitative computed tomography (QCT) imaging estimates of Hounsfield units (HU) and volumetric BMD have been implemented as alternative methodologies for assessing fracture risk. However, marrow fat within the vertebrae can highly affect the vBMD and fracture properties estimations. To address this issue, 54 vertebrae were dissected from nine cadaveric spines and scanned using SE-QCT (120kVp) and dual energy (DE)-QCT (80/140 kVp), with the latter accounting for marrow fat within the vertebrae. The vertebrae were then scanned using DXA and subjected to mechanical testing to obtain fracture properties. aBMD outcomes from DXA showed a better correlation with DE-QCT vBMD versus SE outcomes [DE: aBMD vs. vBMD (R2: 0.61); SE: aBMD vs. vBMD (R2: 0.27)]. SE-QCT underestimated vertebral vBMD by -56% (p<0.0001) when compared to DE-QCT. vBMD estimates from SE-QCT could predict 45% and 37% of the vertebral failure loads and stiffness, respectively, compared to 67% and 46% from DE-QCT. DE-QCT vBMD outcomes highly correlated with fracture properties of vertebrae as compared to SE-QCT metrics. As DE scanning has the ability to correct for the effects of bone marrow fat, estimated vBMD from SE-QCT were significantly underestimated compared to DE-QCT. Dual energy CT scanning has the potential to more accurately predict vertebral failure and aid the clinician in the evaluation of appropriate interventions. Future studies should consider implementing DE-QCT in their fracture assessment.


Assuntos
Densidade Óssea , Fraturas Ósseas , Absorciometria de Fóton , Fraturas Ósseas/diagnóstico por imagem , Humanos , Vértebras Lombares/diagnóstico por imagem , Tomografia Computadorizada por Raios X
2.
Spine J ; 19(8): 1346-1353, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-30902702

RESUMO

BACKGROUND CONTEXT: Obesity, which is currently surging to epidemic levels within the United States, has been linked to hyperostotic conditions like diffuse idiopathic skeletal hyperostosis (DISH) and ossification of the posterior longitudinal ligament (OPLL). Excess adipose tissue and insulin-resistance may cause a systemic increase in serum levels of proinflammatory cytokines and these signals can affect bone metabolism. Spinal ligaments and discs may have receptors for these signaling molecules. Anecdotal observations at this institution suggested that there is a clinically important subset of younger patients with obesity and multilevel stenosis in the presence of unusual calcification of the spinal ligaments that is distinct from DISH. PURPOSE: To determine if there is an association between truncal obesity and calcifications of the spine in nonelderly adults. STUDY DESIGN/SETTING: This is a retrospective analysis of 214 sequential trauma patients between the ages of 29 and 50. Patients' age, sex, truncal obesity, history of hypertension, and diabetes were assessed for association with ligamentous calcification of the spine. PATIENT SAMPLE: Sequential trauma patients were chosen from our institution's trauma database between 2006 and 2007. METHODS: Full spine computed tomography (CT) imaging was examined for bone formation in the region of the anterior longitudinal ligament (ALL) and annulus, posterior longitudinal ligament (PLL) and annulus, and the ligamentum flavum (LF). Visceral and subcutaneous abdominal fat were also evaluated. The authors report no study funding sources or conflicts of interest. OUTCOME MEASURES: Calcification of the ALL, PLL, and LF were assigned a score at each level and then combined for a total calcification score (TCS) for the entire spine. Obesity was estimated using a truncal body mass index (TBMI) by using a previously validated CT derived truncal total adiposity volume (TAV). RESULTS: ALL calcification was associated with age, male gender, hypertension, and increased adiposity. PLL calcification was significantly associated with age and hypertension. LF calcification was only associated with increased obesity. CONCLUSIONS: In our analysis of nonelderly patients, LF calcification was independently associated with truncal obesity. This implies obesity plays a greater role in calcification than could be accounted for by simply age-related degeneration or gender.


Assuntos
Obesidade/epidemiologia , Ossificação do Ligamento Longitudinal Posterior/epidemiologia , Traumatismos da Coluna Vertebral/epidemiologia , Tomografia Computadorizada por Raios X , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Ossificação do Ligamento Longitudinal Posterior/diagnóstico por imagem , Estudos Retrospectivos , Traumatismos da Coluna Vertebral/diagnóstico por imagem , Coluna Vertebral/diagnóstico por imagem
3.
PLoS One ; 13(9): e0203714, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30248138

RESUMO

Anterior cervical discectomy and fusion (ACDF) is performed to relieve pain caused by degenerative disk disease and nerve obstruction. As an alternative to bone graft, autologous concentrated bone marrow aspirate (CBMA) is used to achieve vertebral fusion with a satisfactory success rate. This has been attributed in part to bone marrow-resident mesenchymal stromal cells (MSCs) with the capacity to differentiate into osteoblasts and generate bone tissue. To date, there has been no study comparing cellular yields, MSC frequencies and their osteogenic potential with ACDF outcome. Patients (n = 24) received ACDF with CBMA and allograft bone matrix. Colony forming unit fibroblast (CFU-F) and CFU-osteoblasts (CFU-O) assays were performed on CBMA samples to enumerate MSCs (CFU-F) and osteogenic MSCs (CFU-O). CFUs were normalized to CBMA volume to define yield and also to mononuclear cells (MNC) to define frequency. After 1-year, fusion rates were good (86.7%) with pain and disability improved. There was a negative relationship between MNC and CFU-F measurements with age of patient and CFU-Os negatively correlated with age in females but not males. Tobacco use did not affect CBMA but was associated with poorer clinical outcome. Surprisingly, we found that while high-grade fusion was not associated with CFU-O, it correlated strongly (p<0.0067) with CBMA containing the lowest frequencies of CFU-F (3.0x10(-6)-5.83x10(-5) CFU-F/MNC). MNC levels alone were not responsible for the results. These observations suggest that osteogenesis by human bone marrow is controlled by homeostatic ratio of MSCs to other cellular bone marrow components rather than absolute level of osteogenic MSCs, and that a lower ratio of MSCs to other cellular components in marrow tends to predict effective osteogenesis during ACDF. The results presented herein challenge the current dogma surrounding the proposed mechanism of MSCs in bone healing.


Assuntos
Vértebras Cervicais/cirurgia , Transplante de Células-Tronco Mesenquimais , Fusão Vertebral/métodos , Adulto , Fatores Etários , Idoso , Células da Medula Óssea/citologia , Transplante de Medula Óssea , Diferenciação Celular , Ensaio de Unidades Formadoras de Colônias , Feminino , Fibroblastos/citologia , Humanos , Masculino , Células-Tronco Mesenquimais/citologia , Pessoa de Meia-Idade , Osteoblastos/citologia , Osteogênese , Fatores Sexuais , Uso de Tabaco , Resultado do Tratamento
4.
Stem Cells Transl Med ; 7(4): 342-353, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29405665

RESUMO

Non-union defects of bone are a major problem in orthopedics, especially for patients with a low healing capacity. Fixation devices and osteoconductive materials are used to provide a stable environment for osteogenesis and an osteogenic component such as autologous human bone marrow (hBM) is then used, but robust bone formation is contingent on the healing capacity of the patients. A safe and rapid procedure for improvement of the osteoanabolic properties of hBM is, therefore, sought after in the field of orthopedics, especially if it can be performed within the temporal limitations of the surgical procedure, with minimal manipulation, and at point-of-care. One way to achieve this goal is to stimulate canonical Wingless (cWnt) signaling in bone marrow-resident human mesenchymal stem cells (hMSCs), the presumptive precursors of osteoblasts in bone marrow. Herein, we report that the effects of cWnt stimulation can be achieved by transient (1-2 hours) exposure of osteoprogenitors to the GSK3ß-inhibitor (2'Z,3'E)-6-bromoindirubin-3'-oxime (BIO) at a concentration of 800 nM. Very-rapid-exposure-to-BIO (VRE-BIO) on either hMSCs or whole hBM resulted in the long-term establishment of an osteogenic phenotype associated with accelerated alkaline phosphatase activity and enhanced transcription of the master regulator of osteogenesis, Runx2. When VRE-BIO treated hBM was tested in a rat spinal fusion model, VRE-BIO caused the formation of a denser, stiffer, fusion mass as compared with vehicle treated hBM. Collectively, these data indicate that the VRE-BIO procedure may represent a rapid, safe, and point-of-care strategy for the osteogenic enhancement of autologous hBM for use in clinical orthopedic procedures. Stem Cells Translational Medicine 2018;7:342-353.


Assuntos
Medula Óssea/efeitos dos fármacos , Glicogênio Sintase Quinase 3 beta/antagonistas & inibidores , Células-Tronco Mesenquimais/efeitos dos fármacos , Osteogênese/efeitos dos fármacos , Animais , Medula Óssea/metabolismo , Células da Medula Óssea/efeitos dos fármacos , Células da Medula Óssea/metabolismo , Diferenciação Celular/efeitos dos fármacos , Células Cultivadas , Feminino , Humanos , Células-Tronco Mesenquimais/metabolismo , Camundongos Nus , Osteoblastos/efeitos dos fármacos , Osteoblastos/metabolismo , Ratos , Ratos Nus , Transdução de Sinais/efeitos dos fármacos
5.
Proc (Bayl Univ Med Cent) ; 30(3): 268-272, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28670054

RESUMO

A retrospective, comparative study was performed reviewing the electronic medical records and digital radiographs of patients who underwent treatment for intertrochanteric and pertrochanteric hip fractures with either a hip screw and side plate (HSSP) or intramedullary nail. A total of 430 patients were treated with HSSP, and 725 were managed with a cephalomedullary nail (CMN). Of these, 103 sustained a contralateral hip fracture. Fixation technique was not associated with a significant difference in the rate of contralateral fracture. Among the patients with a contralateral fracture, the median time to contralateral fracture was 119.28 months following HSSP and 81.97 months following CMN. Bisphosphonate use was found to be a significant predictor of contralateral fracture for all patients, but when matching using propensity scores, its use was found to be insignificant. In conclusion, there was no difference in the rate of subsequent contralateral hip fracture when comparing HSSP with CMN. Additionally, the time to second surgery between the two treatment modalities was found to be statistically insignificant. It is unclear if bisphosphonate use increased the odds of having a contralateral fracture, regardless of the surgical intervention. The difference in the bisphosphonate effect using propensity score matching suggests that the results may be due to confounding variables and bias.

7.
Spine J ; 17(3): 418-430, 2017 03.
Artigo em Inglês | MEDLINE | ID: mdl-27765715

RESUMO

BACKGROUND CONTEXT: Spine pain and the disability associated with it are epidemic in the United States. According to the National Center for Health Statistics, more than 650,000 spinal fusion surgeries are performed annually in the United States, and yet there is a failure rate of 15%-40% when standard methods employing current commercial bone substitutes are used. Autologous bone graft is the gold standard in terms of fusion success, but the morbidity associated with the procedure and the limitations in the availability of sufficient material have limited its use in the majority of cases. A freely available and immunologically compatible bone mimetic with the properties of live tissue is likely to substantially improve the outcome of spine fusion procedures without the disadvantages of autologous bone graft. PURPOSE: This study aimed to compare a live human bone tissue analog with autologous bone grafting in an immunocompromised rat model of posterolateral fusion. DESIGN/SETTING: This is an in vitro and in vivo preclinical study of a novel human stem cell-derived construct for efficacy in posterolateral lumbar spine fusion. METHODS: Osteogenically enhanced human mesenchymal stem cells (OEhMSCs) were generated by exposure to conditions that activate the early stages of osteogenesis. Immunologic characteristics of OEhMSCs were evaluated in vitro. The secreted extracellular matrix from OEhMSCs was deposited on a clinical-grade gelatin sponge, resulting in bioconditioned gelatin sponge (BGS). Bioconditioned gelatin sponge was used alone, with live OEhMSCs (BGS+OEhMSCs), or with whole human bone marrow (BGS+hBM). Efficacy for spine fusion was determined by an institutionally approved animal model using 53 nude rats. RESULTS: Bioconditioned gelatin sponge with live OEhMSCs did not cause cytotoxicity when incubated with immunologically mismatched lymphocytes, and OEhMSCs inhibited lymphocyte expansion in mixed lymphocyte assays. Bioconditioned gelatin sponge with live OEhMSC and BGS+hBM constructs induced profound bone growth at fusion sites in vivo, with a comparable rate of fusion with syngeneic bone graft (negative [0 of 10], BGS alone [0 of 10], bone graft [7 of 10], BGS+OEhMSC [10 of 15], and BGS+hBM [8 of 8]). CONCLUSIONS: Collectively, these studies demonstrate that BGS+OEhMSC constructs possess low immunogenicity and drive vertebral fusion with efficiency matching syngeneic bone graft in rodents. We also demonstrate that BGS serves as a promising scaffold for spine fusion when combined with hBM.


Assuntos
Células-Tronco Adultas , Aloenxertos , Substitutos Ósseos , Transplante Ósseo/métodos , Vértebras Lombares/cirurgia , Células-Tronco Mesenquimais , Fusão Vertebral/métodos , Adulto , Animais , Feminino , Gelatina , Humanos , Vértebras Lombares/fisiologia , Modelos Animais , Osteogênese , Ratos Nus , Transplante Autólogo , Transplante Homólogo
8.
Spine (Phila Pa 1976) ; 41 Suppl 7: S14-5, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27015060

RESUMO

Improving spinal fusion by optimizing scaffold and surface engineering is a topic of interest for both surgeons and researchers. Concerns regarding patient safety with off-label use of bone morphogenetic protein (BMP) have increased, and patients are choosing minimally invasive spine surgery to lessen morbidity by avoiding harvest of bone graft. These trends may be driving studies on how surgeons can avoid issues associated with biologics (e.g., cost, morbidity), while achieving efficacious and safe bone fusion.


Assuntos
Materiais Revestidos Biocompatíveis , Nanoestruturas , Procedimentos Ortopédicos , Engenharia Tecidual/métodos , Alicerces Teciduais , Animais , Benzofenonas , Dexametasona , Humanos , Cetonas , Polietilenoglicóis , Polímeros , Ratos , Propriedades de Superfície
9.
J Bone Joint Surg Am ; 97(22): e73, 2015 Nov 18.
Artigo em Inglês | MEDLINE | ID: mdl-26582625

RESUMO

BACKGROUND: With the rise of obesity in the American population, there has been a proportionate increase of obesity in the trauma population. The purpose of this study was to use a computed tomography-based measurement of adiposity to determine if obesity is associated with an increased burden to the health-care system in patients with orthopaedic polytrauma. METHODS: A prospective comprehensive trauma database at a level-I trauma center was utilized to identify 301 patients with polytrauma who had orthopaedic injuries and intensive care unit admission from 2006 to 2011. Routine thoracoabdominal computed tomographic scans allowed for measurement of the truncal adiposity volume. The truncal three-dimensional reconstruction body mass index was calculated from the computed tomography-based volumes based on a previously validated algorithm. A truncal three-dimensional reconstruction body mass index of <30 kg/m(2) denoted non-obese patients and ≥ 30 kg/m(2) denoted obese patients. The need for orthopaedic surgical procedure, in-hospital mortality, length of stay, hospital charges, and discharge disposition were compared between the two groups. RESULTS: Of the 301 patients, 21.6% were classified as obese (truncal three-dimensional reconstruction body mass index of ≥ 30 kg/m(2)). Higher truncal three-dimensional reconstruction body mass index was associated with longer hospital length of stay (p = 0.02), more days spent in the intensive care unit (p = 0.03), more frequent discharge to a long-term care facility (p < 0.0002), higher rate of orthopaedic surgical intervention (p < 0.01), and increased total hospital charges (p < 0.001). CONCLUSIONS: Computed tomographic scans, routinely obtained at the time of admission, can be utilized to calculate truncal adiposity and to investigate the impact of obesity on patients with polytrauma. Obese patients were found to have higher total hospital charges, longer hospital stays, discharge to a continuing-care facility, and a higher rate of orthopaedic surgical intervention.


Assuntos
Fraturas Ósseas/terapia , Preços Hospitalares/estatística & dados numéricos , Luxações Articulares/terapia , Ligamentos/lesões , Traumatismo Múltiplo/terapia , Obesidade/complicações , Adiposidade , Adulto , Índice de Massa Corporal , Estudos de Casos e Controles , Feminino , Fraturas Ósseas/complicações , Fraturas Ósseas/economia , Fraturas Ósseas/mortalidade , Mortalidade Hospitalar , Humanos , Imageamento Tridimensional , Luxações Articulares/complicações , Luxações Articulares/economia , Luxações Articulares/mortalidade , Tempo de Internação/economia , Tempo de Internação/estatística & dados numéricos , Assistência de Longa Duração/estatística & dados numéricos , Extremidade Inferior/lesões , Masculino , Pessoa de Meia-Idade , Traumatismo Múltiplo/complicações , Traumatismo Múltiplo/economia , Traumatismo Múltiplo/mortalidade , Obesidade/diagnóstico por imagem , Obesidade/economia , Procedimentos Ortopédicos/economia , Procedimentos Ortopédicos/estatística & dados numéricos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Centros de Traumatologia/economia , Centros de Traumatologia/estatística & dados numéricos , Estados Unidos
10.
J Bone Miner Res ; 30(1): 83-94, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25130615

RESUMO

Although bone has remarkable regenerative capacity, about 10% of long bone fractures and 25% to 40% of vertebral fusion procedures fail to heal. In such instances, a scaffold is employed to bridge the lesion and accommodate osteoprogenitors. Although synthetic bone scaffolds mimic some of the characteristics of bone matrix, their effectiveness can vary because of biological incompatibility. Herein, we demonstrate that a composite prepared with osteogenically enhanced mesenchymal stem cells (OEhMSCs) and their extracellular matrix (ECM) has an unprecedented capacity for the repair of critical-sized defects of murine femora. Furthermore, OEhMSCs do not cause lymphocyte activation, and ECM/OEhMSC composites retain their in vivo efficacy after cryopreservation. Finally, we show that attachment to the ECM by OEhMSCs stimulates the production of osteogenic and angiogenic factors. These data demonstrate that composites of OEhMSCs and their ECM could be utilized in the place of autologous bone graft for complex orthopedic reconstructions.


Assuntos
Regeneração Óssea , Criopreservação , Proteínas da Matriz Extracelular/biossíntese , Matriz Extracelular/química , Células-Tronco Mesenquimais/metabolismo , Alicerces Teciduais/química , Animais , Células Cultivadas , Matriz Extracelular/metabolismo , Humanos , Células-Tronco Mesenquimais/citologia , Camundongos
11.
Obesity (Silver Spring) ; 21(5): 997-1003, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23784903

RESUMO

OBJECTIVE: To utilize data from routine CT scans to quantify obesity in polytrauma patients without the need to obtain a height and weight. DESIGN AND METHODS: We utilized a comprehensive database including multidetector CT thoracoabdominal images of all polytrauma patients admitted to a Level 1 trauma center. One thousand one hundred seventy-four patients were reviewed from 2006 to 2008 and of these, 162 had previous documentation of Body Mass Index (BMI) or height and weight measurements as an outpatient within 6 months of trauma activation and with a truncal girth smaller than the scanning area of the CT machine. Truncal Adiposity Volume (TAV) was calculated from three dimensional reconstructions (3DRs) of the CT scans of the thorax and abdomen obtained in the emergency department. RESULTS: Statistical analysis yielded a fairly good correlation between TAV and BMI (correlation coefficient = 0.77; p-value < 0.0001). The intra-observer and inter-observer correlations in measuring TAV were high; 0.99 and 0.98 respectively. A linear regression equation of BMI on TAV was estimated and it had a form: 3DR BMI = 20.81+0.00064×TAV. In conclusion, TAV provides a reproducible means of evaluating obesity in trauma patients from routinely obtained CT scans. CONCLUSIONS: The TAV eliminates the often problematic task of obtaining a height and weight in a trauma patient and it correlates fairly well with the most commonly used clinical method of quantifying patient adiposity, BMI. This method may provide a more direct measurement of adiposity than does BMI, and holds promise for improving trauma care and research in the obese patient.


Assuntos
Abdome , Adiposidade , Índice de Massa Corporal , Traumatismo Múltiplo/diagnóstico por imagem , Obesidade/diagnóstico por imagem , Tórax , Tomografia Computadorizada por Raios X/métodos , Adulto , Serviço Hospitalar de Emergência , Feminino , Humanos , Modelos Lineares , Masculino , Traumatismo Múltiplo/complicações , Obesidade/complicações , Variações Dependentes do Observador , Reprodutibilidade dos Testes
12.
Spine (Phila Pa 1976) ; 38(15): E907-18, 2013 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-23591659

RESUMO

STUDY DESIGN: Prospective, multicenter, randomized Food and Drug Administration approved investigational device exemption clinical trial. OBJECTIVE: To evaluate the safety and effectiveness of the PCM Cervical Disc compared with anterior cervical discectomy and fusion (ACDF) in the treatment of patients with degenerative spondylosis and neurological symptoms at 1 level between C3-C4 and C7-T1. SUMMARY OF BACKGROUND DATA: Cervical disc arthroplasty in the treatment of symptomatic cervical spondylosis has been studied in other series. The PCM Cervical Disc is a nonconstrained motion-sparing alternative to ACDF. METHODS: Patients 18 to 65 years of age with single-level symptomatic cervical spondylosis with radiculopathy and/or myelopathy unresponsive to nonoperative treatment were enrolled, including patients with prior nonadjacent or adjacent single-level fusions. The per-protocol patient sample at 2 years included 342 patients (189 PCM, 153 ACDF). Longitudinal outcomes were comparatively evaluated. RESULTS: At 2 years postoperatively, clinical measures-neck and arm pain visual analogue scale, Neck Disability Index (NDI), SF-36, and neurological status-were significantly improved from preoperative baselines in both groups. Mean NDI score at 2 years was significantly lower in PCM group (P = 0.029). There were no statistical differences between groups in rates of surgery-related serious adverse events (5.6% PCM, 7.4% ACDF) or secondary surgical procedures (5.2% PCM, 5.4% ACDF). Patients with PCM reported lower dysphagia scores (8.8/100 vs. 12.1/100; P = 0.045) and higher patient satisfaction (82.8/100 vs. 81.4/100). Overall success, a composite endpoint including minimum 20% NDI improvement, no major complications, no neurological worsening, no secondary surgical procedures, and meeting radiographical criteria of motion for PCM and fusion for ACDF, was significantly greater in the PCM group (75.1% vs. 64.9%; P = 0.020). CONCLUSION: The treatment of symptomatic single-level cervical spondylosis with PCM achieves clinical outcomes that are at least equivalent to ACDF while maintaining motion. At 2 years, patients with PCM had lower NDI scores, statistically lower rate of prolonged dysphagia, greater patient satisfaction, and superior overall success.


Assuntos
Vértebras Cervicais/cirurgia , Discotomia/métodos , Fusão Vertebral/métodos , Espondilose/cirurgia , Substituição Total de Disco/métodos , Adolescente , Adulto , Idoso , Vértebras Cervicais/fisiopatologia , Avaliação da Deficiência , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Cervicalgia/diagnóstico , Cervicalgia/fisiopatologia , Medição da Dor , Estudos Prospectivos , Amplitude de Movimento Articular , Doenças da Medula Espinal/complicações , Doenças da Medula Espinal/fisiopatologia , Doenças da Medula Espinal/cirurgia , Espondilose/complicações , Espondilose/fisiopatologia , Inquéritos e Questionários , Fatores de Tempo , Resultado do Tratamento , Estados Unidos , United States Food and Drug Administration , Adulto Jovem
13.
Spine (Phila Pa 1976) ; 38(14): 1183-7, 2013 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-23474597

RESUMO

STUDY DESIGN: Retrospective comparative study using prospectively collected data. OBJECTIVE: To compare the rate of infection with and without the use of vancomycin powder application during posterior cervical instrumentation. SUMMARY OF BACKGROUND DATA: Surgical site infections (SSI) are a significant source of morbidity in multilevel posterior-instrumented fusions for cervical spondylotic myelopathy (CSM). Local delivery of antibiotics has been associated with decreased rates of SSI in posterior-instrumented fusions, but no study has addressed the effects of these measures on a population composed of exclusively multilevel posterior cervical instrumentation performed with decompression for CSM. METHODS: All patients undergoing multilevel posterior decompression and instrumentation for CSM by a single surgeon from 2003-2011 were included. Post hoc analysis of prospectively collected data was analyzed comparing consecutive patients treated without the use of vancomycin powder with those treated after the initiation of vancomycin powder prophylaxis. Intervention cohort and controls were examined for differences in SSI rate, body mass index, neurological status, comorbidities, and complications. RESULTS: A total of 112 patients were included in the study. Intervention (n = 40) and control (n = 72) groups were statistically similar with regard to age, body mass index, comorbidities, estimated blood loss, and operative time. Univariate analysis showed a significant decrease in infection rate in the intervention group (0%) compared with the control group (15%) in this high-risk population (P = 0.007; power = 81%). No adverse events were noted in the intervention group associated with the use of vancomycin powder. CONCLUSION: The local application of vancomycin was associated with a significant reduction in the risk of SSI in multilevel posterior cervical-instrumented fusions for CSM. This study supports the growing body of evidence that vancomycin powder placed in the wound can reduce the incidence of postoperative wound infections, and is the first that addresses this specific population. LEVEL OF EVIDENCE: 2.


Assuntos
Vértebras Cervicais/cirurgia , Fusão Vertebral/métodos , Infecção da Ferida Cirúrgica/prevenção & controle , Vancomicina/uso terapêutico , Antibacterianos/uso terapêutico , Antibioticoprofilaxia/métodos , Vértebras Cervicais/patologia , Descompressão Cirúrgica/efeitos adversos , Descompressão Cirúrgica/métodos , Seguimentos , Humanos , Staphylococcus aureus Resistente à Meticilina/efeitos dos fármacos , Staphylococcus aureus Resistente à Meticilina/isolamento & purificação , Pessoa de Meia-Idade , Pós , Estudos Retrospectivos , Doenças da Medula Espinal/cirurgia , Fusão Vertebral/efeitos adversos , Espondilose/cirurgia , Infecção da Ferida Cirúrgica/etiologia , Infecção da Ferida Cirúrgica/microbiologia , Fatores de Tempo , Resultado do Tratamento
14.
Spine J ; 13(8): 856-61, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23465740

RESUMO

BACKGROUND CONTEXT: Characteristic changes of the facet joints, including synovial cysts, facet joint hypertrophy, and facet joint effusions, on magnetic resonance imaging (MRI) and computed tomography have been associated with lumbar degenerative spondylolisthesis. The cervical facets have not been examined for associations with cervical degenerative spondylolisthesis similar to those seen in the lumbar spine. PURPOSE: To define abnormalities of the facet joints seen on supine MRI that correlate with cervical spondylolisthesis seen on upright radiographs. STUDY DESIGN: Retrospective radiographic review of consecutive patients with a universally applied standard. PATIENT SAMPLE: A total of 204 consecutive patients from a single institution, with both an MRI and upright radiographs, were reviewed. OUTCOME MEASURES: Sagittal plane displacement on upright lateral radiographs was compared with MRI. The total area of the facet joint and the amount of facet joint asymmetry were measured on an axial MRI. METHODS: The data were analyzed to determine a significant association between the cervical degenerative spondylolisthesis and the following: facet joint asymmetry, increased total area of the facet joint, and age. RESULTS: Degenerative spondylolisthesis was seen in 26 patients at C3-C4 and in 27 patients at C4-C5. Upright radiographs identified significantly more degenerative spondylolisthesis than MRIs at levels C3-C4 and C4-C5, 26 versus 6 (p<.001) at C3-C4 and 27 versus 11 (p<.001) at C4-C5. Patients with degenerative spondylolisthesis were more likely to be older, have a larger total facet area, and more facet asymmetry at C3-C4 and C4-C5 (p<.05). CONCLUSIONS: Supine MRIs underestimate sagittal displacement compared with upright lateral radiographs. Asymmetric facet hypertrophy at C3-C4 and C4-C5 is associated with degenerative spondylolisthesis on upright lateral films even in the absence of anterolisthesis on supine MRIs.


Assuntos
Vértebras Cervicais/patologia , Instabilidade Articular/patologia , Espondilolistese/patologia , Articulação Zigapofisária/patologia , Adulto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Instabilidade Articular/complicações , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Espondilolistese/complicações
15.
J Clin Med ; 2(3): 49-66, 2013 Aug 19.
Artigo em Inglês | MEDLINE | ID: mdl-26237062

RESUMO

For spinal fusions and the treatment of non-union fractures, biological substrates, scaffolds, or carriers often are applied as a graft to support regeneration of bone. The selection of an appropriate material critically influences cellular function and, ultimately, patient outcomes. Human bone marrow mesenchymal stem cells (BMSCs) are regarded as a critical component of bone healing. However, the interactions of BMSCs and commercial bone matrices are poorly reported. BMSCs were cultured with several commercially available bone substrates (allograft, demineralized bone matrix (DBM), collagen, and various forms of calcium phosphates) for 48 h to understand their response to graft materials during surgical preparation and the first days following implantation (cell retention, gene expression, pH). At 30 and 60 min, bone chips and inorganic substrates supported significantly more cell retention than other materials, while collagen-containing materials became soluble and lost their structure. At 48 h, cells bound to ß-tricalcium phosphate-hydroxyapatite (ßTCP-HA) and porous hydroxyapatite (HA) granules exhibited osteogenic gene expression statistically similar to bone chips. Through 24 h, the DBM strip and ßTCP-collagen became mildly acidic (pH 7.1-7.3), while the DBM poloxamer-putties demonstrated acidity (pH < 5) and the bioglass-containing carrier became basic (pH > 10). The dissolution of DBM and collagen led to a loss of cells, while excessive pH changes potentially diminish cell viability and metabolism. Extracts from DBM-poloxamers induced osteogenic gene expression at 48 h. This study highlights the role that biochemical and structural properties of biomaterials play in cellular function, potentially enhancing or diminishing the efficacy of the overall therapy.

16.
Coluna/Columna ; 12(2): 138-141, 2013. ilus, tab
Artigo em Inglês | LILACS | ID: lil-680730

RESUMO

OBJECTIVE: The purpose of this study is to report the results using PediGuard (electrical conductivity device) to reduce radiation exposure while drilling the pilot hole for pedicle screw placement. METHOD: Eighteen patients diagnosed with a degenerative lumbar spine, that required a posterior spinal fusion. Average age of the patients were 55 ± 12 years. Patients received postoperative CT scans of all screws. Scans were reviewed by an independent reviewer grading 'in' < 2 mm of breach , or 'out' > 2 mm of breach. In a randomized fashion, the surgeon created pilot holes with either his standard technique or by using the PediGuard. Fluoroscopy was used for each drilling as necessary. Once the pilot hole was created, the surgeon inserted titanium screws into the pedicle pilot holes. A total of 78 screws (39 standard probe and 39 PediGuard ) were analyzed. RESULTS: 78 screws (39 standard probe and 39 PediGuard were analyzed. No significant difference in breach rate > 2mm by either method (p=1.000), with one screw out in each group. Fluoroscopy shots averaged 5.2 (range, 0 to 15), average decrease of 2.3 (30%) per screw in the PediGuard group vs. 7.5 (range, 2 to 17) in the standard group (p< .001). CONCLUSION: This trial to assess pedicle probe location within the pedicle and vertebral body showed the number of fluoroscopy shots were reduced by 30%, compared to a standard probe while maintaining a 97.5% screw placement accuracy.


OBJETIVO: Relatar os resultados do uso do dispositivo PediGuard para reduzir a exposição à radiação durante a perfuração do orifício piloto para a colocação do parafuso pedicular. MÉTODOS: Dezoito pacientes com diagnóstico de doença degenerative da coluna lombar e submetidos à artrodese posterior (todos pelo investigador principal [CDC]) foram incluídos no estudo. A idade média dos pacientes era de 55 ± 12 anos. No pós-operatório foi realizada tomografia computadorizada em todos os pacientes para avaliação do posicionamento dos parafusos. Os exames foram revisados por um avaliador independente. Os parafusos foram considerados no interior do pedículo quando o rompimento da cortical era menor que 2mm, e localizados for a quando o rompimento era maior que 2mm. O orificio piloto foi re alizado foi realizado de modo randomizado por meio de sonda ou utilizando o PediGuard, tendo sido utilizada a fluoroscopia quando necessario. Parafusos pediculares de titânio foram utilizados de acordo com a técnica padrão. Foram utilizados 78 parafusos de titânio de acordo com a técnica padrão, 39 parafusos com orificio piloto realizado com sonda e 39 parafusos com orificio piloto realizado com o PediGuard. RESULTADOS: Não houve diferença significativa na taxa de rompimento do pedículo > 2 milímetros por qualquer um dos dois métodos (p = 1,000), tendo sido observado apenas 1 parafuso fora do pedículo vertebral em ambos os grupos. A media da utilização da fluoroscopia foi 5,2 disparos (variando de 0 a 15) por parafuso no grupo PediGuard vs 7,5 (variando de 2 a 17) no grupo em que a sonda foi utilizada (p <0,0001). Foi observada redução média de 2,3 disparos (30%) por parafuso com a utilização do PediGuard. Foram realizados 202 disparos na fluoroscopia no grupo do PediGuard e 293 no grupo padrão. CONCLUSÕES: Neste estudo prospectivo e randomizado foi observado que a utilização do PediGuard para o prepare do orifício piloto reduz os disparos da fluoroscopia em 30% em comparação com a utilização de sonda, mantendo a precisão da colocação do parafuso pedicular em 97,5% das perfurações.


OBJETIVO: La finalidad de este estudio es relatar los resultados al usar PediGuard (dispositivo de diferenciación de conductividad eléctrica) para reducir la exposición a la radiación al perforar el orificio piloto para la colocación de tornillos pediculares. MÉTODO: Dieciocho pacientes con diagnóstico de degeneración de la columna lumbar, que precisaban artrodesis espinal posterior. El promedio de edad de los pacientes fue 55 ± 12 años. Los pacientes fueron sometidos a TC de todos los tornillos después de la cirugía. Las TC fueron analizadas por un revisor independiente y graduadas como 'dentro' < 2 mm de vacío o 'fuera' > 2 mm de vacío. De modo aleatorio, el cirujano creó orificios piloto con su técnica estándar o usando PediGuard. La fluoroscopía fue usada para cada perforación, de acuerdo a la necesidad. Una vez creado el orificio piloto, el cirujano insertó tornillos de titanio en los orificios pediculares pilotos. Fue analizado un total de 78 tornillos (39 con sonda estándar y 39 con PediGuard). RESULTADOS: Fueron analizados setenta y ocho tornillos (39 con sonda estándar y 39 con PediGuard). No fue encontrada diferencia significativa en la tasa de vacíos > 2 mm en ninguno de los métodos (p = 1,000), con un tornillo fuera en cada grupo. Cada inyección de fluoroscopía fue en promedio 5,2 (franja 0 a 15), la reducción media fue 2,3 (30%) por tornillo en el grupo PediGuard en comparación con 7,5 (franja 2 a 17) en el grupo estándar (p < 0,001). CONCLUSIÓN: Este estudio evalúa la ubicación de la sonda pedicular en el interior del pedículo y el cuerpo vertebral mostró que el número de inyecciones de fluoroscopía fue reducido en 30% en comparación con la sonda estándar, al mismo tiempo en que mantuvo la precisión de 97,5% en la colocación del tornillo.


Assuntos
Humanos , Coluna Vertebral/cirurgia , Artrodese , Fluoroscopia , Exposição à Radiação , Parafusos Pediculares
17.
Int J Shoulder Surg ; 6(3): 71-5, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23204760

RESUMO

PURPOSE: To established an association between shoulder pain and the stroke specialization among NCAA men swimmers. MATERIALS AND METHODS: All members of the top 25 NCAA men's swim teams were invited to complete the survey. Eleven teams with a total of 187 participants completed the study survey. The teams were mailed surveys that included multiple choice questions regarding their primary stroke and their incidence of shoulder pain. Additionally, the survey included questions about risk factors including distance trained, type of equipment, weight training, and stretching. RESULTS: The analysis showed that there was no significant difference in the rates of shoulder pain among the four strokes and individual medley specialists. The other risk factors did not show a significant correlation with shoulder pain. CONCLUSIONS: This study found no significant correlation between stroke specialty and shoulder pain in male collegiate swimmers. LEVEL OF EVIDENCE: Level 3. CLINICAL RELEVANCE: Descriptive epidemiology study.

18.
Spine (Phila Pa 1976) ; 37(21): E1305-9, 2012 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-22772570

RESUMO

STUDY DESIGN: Prospective, randomized, controlled study. OBJECTIVE: To report the results of using the PediGuard (SpineGuard, Inc., San Francisco, CA), a local electrical conductivity measurement device, to reduce radiation exposure while drilling the pilot hole for pedicle screw placement. SUMMARY OF BACKGROUND DATA: Reports of pedicle screw placement in the lumbar spine have shown medial pedicle perforations with nerve root impingement in addition to lateral pedicle and vertebral body perforations that can impinge the nerve root within the psoas. Routine use of fluoroscopy (fluoro) is thought to reduce the risk of perforations but is associated with increased radiation. A new pedicle-drilling device (PediGuard) which uses electrical conductivity differentiation at the tip for assessing bone versus soft tissue, has been developed to improve the safe positioning of pedicle screws. This device not only warns of an impending medial breach but also is the only device available to, in real time, nonradiographically detect a lateral breach. METHODS.: Eighteen patients with a diagnosis of lumbar degenerative spine who had a posterior spinal fusion were enrolled. The average age of the patients was 55 ± 12 years. Postoperative computed tomographic scans were reviewed by an independent reviewer. Screws were considered "in" (<2 mm of breach) or "out" (≥ 2 mm of breach). In a randomized fashion, the surgeon placed a pilot hole either with a standard technique (manual probe) or the PediGuard, and used fluoro for each drilling as a guidance assist as necessary. Electromyographic testing was not done by the surgeon. A total of 78 screws (39 via standard probe and 39 with PediGuard assist) were analyzed. RESULTS: There was no significant difference in breach rate of 2 mm or more by either of the 2 methods (P = 1.000), with 1 screw out in each group. Fluoro shots averaged 5.2 (range, 0-15) per screw in the PediGuard group versus 7.5 (range, 2-17) in the standard group (P < 0.001). This represents an average decrease of 2.3 (30%) fluoro shots per screw with the PediGuard. There were 202 total fluoro shots used in the PediGuard group versus 293 in the standard group. CONCLUSION: In this prospective, randomized trial of a pedicle drilling device that uses electrical conductivity differentiation at the tip for assessing bone versus soft tissue, the number of fluoro shots was reduced by 30% compared with a standard drilling probe while maintaining a 97.5% accurate, safe screw placement.


Assuntos
Parafusos Ósseos , Vértebras Lombares/cirurgia , Monitorização Intraoperatória/instrumentação , Fusão Vertebral/instrumentação , Adulto , Idoso , Feminino , Fluoroscopia , Humanos , Vértebras Lombares/patologia , Masculino , Pessoa de Meia-Idade , Monitorização Intraoperatória/métodos , Estudos Prospectivos , Reprodutibilidade dos Testes , Fusão Vertebral/métodos , Tomografia Computadorizada por Raios X , Resultado do Tratamento
19.
Sci Transl Med ; 4(132): 132ra55, 2012 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-22553253

RESUMO

The methodology for the repair of critical-sized or non-union bone lesions has unpredictable efficacy due in part to our incomplete knowledge of bone repair and the biocompatibility of bone substitutes. Although human mesenchymal stem cells (hMSCs) differentiate into osteoblasts, which promote bone growth, their ability to repair bone in vivo has been variable. We hypothesized that given the multistage process of osteogenesis, hMSC-mediated repair might be maximal at a specific time point of healing. Using a mouse model of calvarial healing, we demonstrate that the osteo-repair capacity of hMSCs can be substantially augmented by treatment with an inhibitor of peroxisome proliferator-activated receptor γ, but efficacy is confined to the rapid osteogenic phase. Upon entry into the bone-remodeling phase, hMSC retention signals are lost, resulting in truncation of healing. To solve this limitation, we prepared a scaffold consisting of hMSC-derived extracellular matrix (ECM) containing the necessary biomolecules for extended site-specific hMSC retention. When inhibitor-treated hMSCs were coadministered with ECM, they remained at the injury, well into the remodeling phase of healing, which resulted in reproducible and complete repair of critical-sized bone defects in mice in 3 weeks. These data suggest that hMSC-derived ECM and inhibitor-treated hMSCs could be used at optimal times to substantially and reproducibly improve bone repair.


Assuntos
Regeneração Óssea , Matriz Extracelular/metabolismo , Células-Tronco Mesenquimais/citologia , Células-Tronco Mesenquimais/metabolismo , Fosfatase Alcalina/metabolismo , Anilidas/farmacologia , Animais , Regeneração Óssea/efeitos dos fármacos , Diferenciação Celular/efeitos dos fármacos , Colágeno/metabolismo , Matriz Extracelular/efeitos dos fármacos , Regulação da Expressão Gênica/efeitos dos fármacos , Humanos , Transplante de Células-Tronco Mesenquimais , Células-Tronco Mesenquimais/efeitos dos fármacos , Células-Tronco Mesenquimais/enzimologia , Camundongos , Crânio/efeitos dos fármacos , Crânio/patologia , Fatores de Tempo , Cicatrização/efeitos dos fármacos
20.
Exp Biol Med (Maywood) ; 237(5): 491-8, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22619369

RESUMO

The focus of this study was to identify changes in protein expression within the bone tissue environment between osteopenic and control bone tissue of human femoral neck patients with osteoarthritis. Femoral necks were compared from osteopenic patients and age-matched controls. A new method of bone protein extraction was developed to provide a swift, clear view of the bone proteome. Relative changes in protein expression between control and osteopenic samples were quantified using difference gel electrophoresis (DIGE) technology after affinity chromatographic depletion of albumin and IgG. The proteins that were determined to be differentially expressed were identified using standard liquid chromatography mass spectrometry (LC/MS/MS) and database searching techniques. In order to rule out blood contamination, blood from age-matched osteoporotic, osteopenic and controls were analyzed in a similar manner. Image analysis of the DIGE gels indicated that 145 spots in the osteopenic bone samples changed at least ± 1.5-fold from the control samples (P < 0.05). Three of the proteins were identified by LC/MS/MS. Of the proteins that increased in the osteopenic femurs, two were especially significant: carbonic anhydrase I and phosphoglycerate kinase 1. Apolipoprotein A-I was the most prominent protein that significantly decreased in the osteopenic femurs. The blood samples revealed no significant differences between groups for any of these proteins. In conclusion, carbonic anhydrase I, phosphoglycerate kinase 1 and apolipoprotein A-I appeared to be the most significant variations of proteins in patients with osteopenia and osteoarthritis.


Assuntos
Apolipoproteína A-I/metabolismo , Doenças Ósseas Metabólicas/metabolismo , Osso e Ossos/metabolismo , Anidrase Carbônica I/metabolismo , Colo do Fêmur/metabolismo , Osteoartrite/metabolismo , Fosfoglicerato Quinase/metabolismo , Proteínas/análise , Idoso , Cromatografia de Afinidade , Cromatografia Líquida , Eletroforese em Gel Bidimensional , Feminino , Humanos , Espectrometria de Massas , Pessoa de Meia-Idade , Osteoartrite/patologia , Proteoma/análise , Proteômica/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA