Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
EuroIntervention ; 19(7): 580-588, 2023 Sep 18.
Artigo em Inglês | MEDLINE | ID: mdl-37565470

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) in non-calcified aortic regurgitation (NCAR) is an off-label procedure. The balloon-expandable Myval includes extra-large sizes (30.5 mm and 32 mm) of interest in this setting. AIMS: We aimed to evaluate the safety and feasibility of Myval in NCAR. METHODS: This was an international, multicentre, observational study that enrolled all consecutive patients with symptomatic severe NCAR undergoing TAVR with the Myval device. The images were centrally analysed. RESULTS: A total of 113 patients were recruited, 64.6% were men, the mean age was 78.4±7.5 years, and the Society of Thoracic Surgeons score was 2.7±1.7%. Aortic root dilatation was present in 59.3% of patients, 7.1% were bicuspid, and the mean annular area was 638.6±106.0 mm2. The annular area was beyond the recommended range for extra-large sizes in 2.6% of cases, and additional volume was added in 92% (median 4 cc, up to 9 cc). The extra-large sizes were used in 95 patients (84.1%), and the mean oversizing was 17.9±11.0%. The technical success rate was 94.7%; the rate of residual ≥moderate aortic regurgitation was 8.9%, and the pacemaker rate was 22.2%. There were no cases of annular rupture, cardiac tamponade, or aortic dissection, but in 4 patients (3.5%) valve embolisation occurred (1 antegrade and 3 ventricular), all in cases with a tapered left ventricle outflow tract (p=0.007). Thirty-day and 1-year mortality were 5.3% and 9.7%, respectively. Technical success was associated with better survival (97.1% vs 72.7%; p=0.012), and valve embolisation was the main determinant of mortality (p=0.047). CONCLUSIONS: Myval is a feasible and safe option for selected non-operable patients with NCAR and demonstrated good midterm outcomes and lack of impact of oversizing on device durability.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Masculino , Humanos , Idoso , Idoso de 80 Anos ou mais , Feminino , Substituição da Valva Aórtica Transcateter/métodos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Desenho de Prótese
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...