1.
Vasc Specialist Int ; 40: 12, 2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38661144

RESUMO

Purpose: This study aims to investigate whether routine screening for silent pulmonary embolism (PE) can be justified in patients with deep vein thrombosis (DVT). Materials and Methods: We retrospectively analyzed the medical records of 201 patients with lower-extremity DVT admitted to the vascular surgery department of a single tertiary university center between 2019 and 2023. All patients underwent clinical evaluation, basic laboratory exams, a whole-leg colored duplex ultrasound, and a computed tomography pulmonary angiography (CTPA), to screen for an occult, underlying PE. Results: The overall incidence of silent PE was 48.8%. The median admission D-dimer level was significantly higher in patients with silent PE than in those without PE (9.60 vs. 5.51 mg/L, P=0.001). A D-dimer value ≥5.14 mg/L was discriminant for predicting silent PE, with a sensitivity of 68.2% and a specificity of 59.3%. Silent PE was significantly more common on the right side, with the embolus located at the main pulmonary, lobar, segmental, and subsegmental arteries in 29.6%, 32.7%, 20.4%, and 17.3%, respectively. A higher incidence of occult PE was observed in patients with iliofemoral DVT (P=0.037), particularly when the thrombus extended to the inferior vena cava (P=0.003). Moreover, iliofemoral DVT was associated with a larger size and a more proximal location of the embolus (P=0.041). Multivariate logistic regression showed that male sex (odds ratio [OR]=2.46, 95% confidence interval [CI]: 1.39-3.53; P=0.026), cancer (OR=2.76, 95% CI: 1.45-4.07; P=0.017), previous venous thromboembolism (VTE) history (OR=2.67, 95% CI: 1.33-4.01; P=0.022), D-dimer value ≥5.14 mg/L (OR=2.24, 95% CI: 1.10-3.38; P=0.033), iliofemoral DVT (OR=2.13, 95% CI: 1.19-3.07; P=0.041), and thrombus extension to the IVC (OR=2.95, 95% CI: 1.43-4.47; P=0.009) served as independent predictors for silent PE. Conclusion: A high incidence of silent PE was observed in patients with lower-extremity DVT. Screening of patients with DVT who have the aforementioned predictive risk factors using CTPA for silent PE may be needed and justified for the efficient management of VTE and its long-term complications.

2.
Vasc Specialist Int ; 39: 39, 2023 Dec 04.
Artigo em Inglês | MEDLINE | ID: mdl-38044693

RESUMO

Endovascular aortic aneurysm sealing (EVAS) with the Nellix endograft was initially considered a groundbreaking and acceptable alternative to conventional endovascular aortic aneurysm repair, with encouraging initial results. However, long-term follow-up has revealed a high incidence of endograft-related complications, such as caudal migration and type Ia endoleaks, indicating the need for reintervention. Managing failed EVAS remains challenging and is an ongoing topic of discussion, especially for high-risk patients. We describe a 70-year-old female who initially underwent EVAS with a Nellix endograft and presented after 5 years of follow-up with caudal endograft migration and a type Ia endoleak. The patient was treated with endovascular implantation of an Altura stent-graft, a relatively new low-profile device with a similar double stent configuration. Device migration and endoleaks were undetectable at 12 months of follow-up, suggesting that the Altura might offer a safe and efficient approach in cases of Nellix proximal failure.

3.
J Endovasc Ther ; : 15266028231172379, 2023 May 11.
Artigo em Inglês | MEDLINE | ID: mdl-37166154

RESUMO

PURPOSE: A variety of last-generation endografts are currently available for standard endovascular repair (EVAR) of infrarenal abdominal aortic aneurysms (AAAs). The purpose of this study is to report the preliminary clinical outcomes of the Minos trimodular stent-graft system, which was recently introduced to the European market. MATERIALS AND METHODS: Between February 2020 and 2022, we treated 41 consecutive AAA patients (mean age 72.2±8.5, 37 males) with elective standard EVAR using the Minos. The mean maximum diameter of AAAs was 54.7±6.6 mm, the mean proximal neck's (PN) diameter was 24.8±2.7 mm, while the relevant length and angulation were 16.0 mm and 21.7°, respectively. Overall, 22 (53.6%) patients presented with shorter and angulated PN, according to the stent-graft's instructions of use, and in 6 (14.6%) patients the PN angulation >60° was combined with concomitant iliac angulation >60°. Eleven (26.8%) EVARs were performed with concomitant enormous iliac artery narrowing and tortuosity. Finally, in 19 (46.3%) AAAs, the distal iliac landing zone was aneurysmatic and they were treated with the bell-bottom technique in 17 patients and with limb extension to the external iliac artery in two cases. We evaluated technical and clinical success of the index procedures, which was based on the combination of five factors: freedom from EVAR-related mortality, from graft-related endoleak of any type, from migration at any part of graft as well the absence of notable increase AAA's sac maximum diameter and the patency of bifurcated stent-graft and of access vessels. RESULTS: Primary technical and clinical success of index procedures was 100%. During a median 12-month radiological follow-up the clinical success remained 100%. No type I or III endoleak, stent-graft migration, EVAR-related death, AAA rupture, or graft-related adverse events or reinterventions were documented. Four (9.8%) type II endoleaks were detected with stable AAA sac diameter. The overall incidence of sac regression was 34.1% (n=14). CONCLUSION: The preliminary results of our series showed that Minos provided excellent feasibility and safety features even through angulated and tortuous iliac vessels and in short and angulated PNs. The overall clinical success at 1 year suggests that performance of Minos follows very high standards. Further validation of these promising results with long-term data is acquired to complete the evaluation of this recently introduced stent-graft system. CLINICAL IMPACT: The current study explored the clinical performance of a new in market ultra-low profile bifurcated abdominal aortic stent-graft, the MINOS. The early and 12-month results of study suggest that implantation of this stent-graft in standard EVAR, even in hostile proximal aortic neck and iliac vessels conditions, follows very high clinical standards and encourage the further clinical use of MINOS.

4.
J Endovasc Ther ; : 15266028231167998, 2023 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-37078515

RESUMO

PURPOSE: To measure the long-term proximal aortic neck dilatation (AND) after elective endovascular aortic aneurysm repair (EVAR) with a variety of contemporary, third-generation, endograft devices. MATERIALS AND METHODS: This is a noninterventional prospective cohort study of 157 patients that underwent standard EVAR with self-expanding abdominal endografts. Patients' recruitment lasted from 2013 to 2017, and postoperative follow-up was up to 5 years. A computed tomography angiography (CTA) was performed at the first month and then at 1, 2, and 5 years. Proximal aortic neck's (PAN) basic morphological characteristics (diameter, length, angulation) were measured based on the analysis of CTA in a standardized fashion. Neck-related adverse events, such as migration, endoleak or rupture, and reinterventions were recorded. RESULTS: Significant straightening of the PAN was evident even in the first-month CTA with concurrent neck shortening that became significant at 5 years. Both the suprarenal aorta and the PAN significantly dilated overtime, with PAN dilating more progressively. Mean neck dilatation at the juxtarenal level was 0.8±0.4 mm at 1 year, 1.8±0.8 mm at 2 years, and 3.9±1.7 mm at 5 years, with a mean neck dilatation rate of 0.07 mm/month overall. The incidence of AND ≥2.5 mm was 37.2% at 2 years and 58.1% at 5 years after EVAR and was considered important (≥5 mm) in 11.5% of patients at 2 years and 30.6% of patients at 5 years. A multivariate analysis performed showed that the endograft oversizing, the preoperative neck diameter, and the preoperative abdominal aortic aneurysm sac diameter served as independent predictors of AND at 5 years. At the 5-year follow-up, 8 late type Ia endoleaks (6.5%) and 7 caudal migrations (5.6%) were identified, while no late ruptures were reported. In total, 11 late endovascular reinterventions (8.9%) were performed. Overall, proximal neck-related adverse outcomes (5/7 migrations and 5/8 endoleaks) and reinterventions (7/11) were significantly associated with the presence of important late AND. CONCLUSION: Proximal AND after EVAR is common. It can influence the long-term durability of proximal endograft fixation and is significantly associated with adverse outcomes, often leading to reinterventions. A systemic and extended surveillance protocol is needed for maintenance of good long-term results. CLINICAL IMPACT: This is a thorough and systematic analysis of the long-term geometric remodeling of the proximal aortic neck after EVAR, that highlights the importance of a strict, and extended surveillance protocol for maintenance of good long-term results of EVAR.

5.
J Vasc Surg ; 77(3): 941-956.e1, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-35948244

RESUMO

OBJECTIVE: To provide an updated systematic literature review summarizing current evidence on aortic neck dilatation (AND) after endovascular aortic aneurysm repair (EVAR) in patients with infrarenal abdominal aortic aneurysm. METHODS: An extensive electronic search in major electronic databases was conducted between January 2000 and December 2021. Eligible for inclusion were observational studies that followed up with patients (n ≥ 20) undergoing EVAR with self-expanding endografts, for 12 or more months, evaluated AND with computed tomography angiography and provided data on relevant outcomes. The primary end point was the incidence of AND after EVAR, and the secondary end points were the occurrence of type Ia endoleak, stent graft migration, secondary rupture, and reintervention. RESULTS: We included 34 studies with a total sample of 12,038 patients (10,413 men; median age, 71 years). AND was defined clearly in 18 studies, but significant differences in AND definition were evidenced. The pooled incidence of AND based on quantitative analysis of 16 studies with a total of 9201 patients (7961 men; median age, 72 years) was calculated at 22.9% (95% confidence interval [CI], 14.4-34.4) over a follow-up period ranging from 12 months to 14 years. The risk of a type Ia endoleak was significantly higher in AND patients compared with those without AND (odds ratio, 2.95; 95% CI, 1.10-7.93; P = .030). Similarly, endograft migration was more common in the AND group compared with the non-AND group (odds ratio, 5.95; 95% CI, 1.80-19.69; P = .004). The combined incidence of secondary rupture and reintervention did not differ significantly between the two groups, even though the combined effect was in favor of the non-AND group. CONCLUSIONS: Proximal AND after EVAR is common and occurs in a large proportion of patients with infrarenal abdominal aortic aneurysm. AND can influence the long-term durability of proximal endograft fixation and is significantly related to adverse outcomes, often leading to reinterventions.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Masculino , Humanos , Idoso , Implante de Prótese Vascular/efeitos adversos , Endoleak/etiologia , Resultado do Tratamento , Dilatação/efeitos adversos , Fatores de Risco , Procedimentos Endovasculares/efeitos adversos , Estudos Retrospectivos , Aneurisma da Aorta Abdominal/cirurgia , Prótese Vascular/efeitos adversos
6.
Vasc Specialist Int ; 38: 13, 2022 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-35712874

RESUMO

Renal artery aneurysms (RAAs) are rare lesions with a prevalence of less than 1% in the general population. Renal arteriovenous malformations (AVMs) are rare lesions with an estimated incidence of less than 0.04%. The coexistence of these two clinical entities is extremely rare and narrows the available treatment options by endovascular or open surgery. We describe a case of a giant symptomatic RAA type III, which was combined with a high-flow renal AVM in the right kidney. Using two vascular plugs, the RAA was excluded successfully. The perfusion of the right kidney's lower pole was preserved by implantation of two covered stents in the inferior segmental renal artery.

7.
Int Angiol ; 41(3): 196-204, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35138072

RESUMO

BACKGROUND: Postimplantation syndrome (PIS) represents an acute phase systemic inflammatory response following endovascular aortic aneurysm repair (EVAR). Our objective was to investigate the risk factors associated with the manifestation and severity of PIS with various available stent-grafts. METHODS: We performed a retrospective analysis of prospectively collected data covering the period 2016-2020. The study included 191 patients. Body temperature was recorded regularly and blood sample was obtained daily. The imaging protocol included computed tomography aortoiliac angiography before surgery and one month after. The volumes of pre-existing and new-onset mural thrombus were calculated in a semi-automated fashion. Five abdominal aortic stent-graft devices were used: Endurant™ ΙΙ, Anaconda™, Treo®, E-tegra® and AFX® 2. Subgroup analysis was performed between woven polyester and ePTFE lined devices. RESULTS: The incidence of PIS was 21.5%. No significant differences were observed regarding demographics, risk factors, aneurysm anatomy or operative data. The amount of pre-existing and new-onset mural thrombus were not related with PIS (P=0.117 and P=0.096). PIS incidence in the polyester subgroup was 24.2%, significantly higher compared to 8.3% in the ePTFE subgroup. In-subgroup analysis revealed that the use of Anaconda™ was associated with the higher frequency (61.1%, P=0.021). Multivariate logistic regression showed that polyester was the single factor significantly associated with PIS (hazard ratio=2.6, P=0.043), as opposed to the new onset thrombus (hazard ratio=1.29, P=0.101). CONCLUSIONS: PIS is not uncommon and should be taken into consideration in patients presenting with fever after EVAR. The endograft's liner material seems to play the primordial role, with woven polyester to be attributed with significantly higher incidence.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Trombose , Aneurisma da Aorta Abdominal/complicações , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Humanos , Incidência , Poliésteres , Estudos Retrospectivos , Fatores de Risco , Stents/efeitos adversos , Síndrome , Trombose/diagnóstico por imagem , Trombose/epidemiologia , Trombose/etiologia , Fatores de Tempo , Resultado do Tratamento
8.
Int Angiol ; 40(5): 359-367, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34142539

RESUMO

BACKGROUND: Primary varicose veins (PVV) represent the most prominent clinical manifestation of chronic venous disease (CVD) and has a complex pathophysiological background. The aim of our study was to investigate the impact of sonographic hemodynamical and contemporary epidemiological factors on the clinical severity of PVV. METHODS: We analyzed the sonographic hemodynamical and clinical parameters from 159 consecutive CVD patients and 233 lower limbs with PVV of clinical stages C2, C3 and C4. Univariate and logistic regression analysis was performed between patients of C2 (N.=70 - 30.0%) and C3 - 4 stages and between subgroups C3 (N.=101 - 43.3%) and C4 (N.=62 - 26.6%). RESULTS: Reflux of common femoral vein and saphenofemoral junction was detected in 43.3% and 65.7%. High venous reflux rates were found at the great saphenous above and below knee (90.1% - 53.2%) and in Cockett perforators (80.5%). Logistic regression revealed that factors associated with the symptomatic C3; 4 stages were the duration of disease >10 years (P=0.015, insufficiency in two or more perforators (P<0.001) and history of 2 pregnancies (P=0.001). Analysis C3 vs. C4 showed that insufficiency in two or more perforators increased the likelihood of advanced C4 clinical stage by 2.2 times, (P=0.037). An additional significant factor was the presence of at least one incompetent Cockett perforator. CONCLUSIONS: Clinical severity of PVV is correlated with a plethora of complex anatomical, hemodynamical and epidemiological factors. Insufficiency in two or more perforators seems to play the most important role and this highlights the value of preoperative venous ultrasound mapping.


Assuntos
Varizes , Insuficiência Venosa , Veia Femoral/diagnóstico por imagem , Humanos , Extremidade Inferior , Veia Safena/diagnóstico por imagem , Varizes/diagnóstico por imagem , Varizes/epidemiologia , Insuficiência Venosa/diagnóstico por imagem , Insuficiência Venosa/epidemiologia
9.
Ann Vasc Surg ; 72: 498-506, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32949740

RESUMO

BACKGROUND: We aimed to investigate whether the transfusion of 2 units of fresh frozen plasma (FFP) immediately post aneurysm exclusion has any effect on the perioperative fibrinogen levels and the outcome of patients undergoing elective endovascular repair (EVAR) of abdominal aortic aneurysm (AAA). METHODS: Consecutive infrarenal AAA patients undergoing elective EVAR with the bifurcated Endurant-II stent-graft (Medtronic) were recruited from 2 vascular units. The first unit has a routine policy of administering 2 units of FFP immediately upon aneurysm exclusion (FFP group), whereas the second unit has no such policy (control group). Serum fibrinogen levels were measured on admission and 24 hr post-EVAR and the perioperative change in fibrinogen (Δfib) was calculated (24-hr postoperative minus preoperative fibrinogen). The 2 groups were compared with regards to the perioperative fibrinogen levels (preoperative, 24-hr postoperative, and Δfib) and the outcome (endoleaks, reinterventions, major adverse cardiovascular events, death) during follow up. RESULTS: A total of 70 patients (41 in the FFP group, 29 controls) were examined. There were 68 men, the mean age was 70 ± 7 years and the maximum AAA diameter was 63.3 ± 13.8 mm. During the follow up (34 ± 19 months), a total of 6 endoleaks were recorded (2 type Ia, 2 type Ib and 1 type II). Mean preoperative fibrinogen, 24-hr postoperative fibrinogen and Δfib was 391.1 ± 92.8 mg/dL, 367.7 ± 97.8 mg/dL and -23.5 ± 51.02 mg/dL, respectively. There was a trend for the fibrinogen to fall 24 hr postprocedure, but this was not statistically significant (P = 0.07). There was a weak negative association between Δfib and endoleaks (P = 0.007, r = -0.29). Compared to controls, the FFP group had a higher 24-hr postoperative fibrinogen (401.8 ± 112.9 mg/dL vs. 319.3 ± 34.9 mg/dL, P < 0.0001) and a lower Δfib (-3.00 ± 56.01 mg/dL vs. -52.48 ± 21.15 mg/dL, P < 0.0001). No significant difference was observed between the 2 groups with regards to endoleaks, reinterventions, major adverse cardiovascular events, or deaths. CONCLUSIONS: Transfusion of 2 units of FFP postaneurysm exclusion prevents a significant drop in plasma fibrinogen 24 hr post-EVAR, but the impact on clinical outcome has yet to be defined.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular , Procedimentos Endovasculares , Fibrinogênio/metabolismo , Troca Plasmática , Plasma , Idoso , Aneurisma da Aorta Abdominal/sangue , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/mortalidade , Biomarcadores/sangue , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Procedimentos Cirúrgicos Eletivos , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Feminino , Grécia , Humanos , Masculino , Pessoa de Meia-Idade , Troca Plasmática/efeitos adversos , Troca Plasmática/mortalidade , Complicações Pós-Operatórias/mortalidade , Complicações Pós-Operatórias/cirurgia , Reoperação , Fatores de Tempo , Resultado do Tratamento