Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Orthop Traumatol Surg Res ; : 103900, 2024 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-38703888

RESUMO

BACKGROUND: The Terrible Triad of the elbow is a constellation of elbow dislocation, radial head fracture and coronoid process fracture. A common type of coronoid fracture documented with this triad is type II Regan-Morrey coronoid fractures. The preferred fixation method for this fracture type is the lasso technique, medial-lateral tunnel orientation being the traditional approach. Considering elbow anatomy, we saw an opportunity to potentially improve fixation by altering the suture lasso tunnel orientation to a proximal-distal orientation. HYPOTHESIS: Two tunnels in the proximal-distal direction would result in greater biomechanical stability as compared to the traditional lasso technique. MATERIAL AND METHODS: A type 2 Regan-Morrey fracture was created in 12 fresh frozen cadaveric elbows at 50% of the coronoid height using an oscillating saw. The humero-ulnar joint was placed in 0 degrees flexion then loaded at a rate of 10mm/min to failure. RESULTS: The control technique (medio-lateral tunnels) showed failure load of 150±81N that was not significantly different (p=0.825) than the 134±116N measured for the modified technique (distal-proximal tunnels). The portion of the load-displacement curve used to calculate stiffness was linear (R^2=0.94±0.04) with determination coefficients that did not differ between the two groups (p=0.351). For stiffness, we measured 17±13N/mm and 14±12N/mm respectively for control and modified techniques that did not result in a significant difference (p=0.674). CONCLUSION: In this attempt to improve the shortcomings of the lasso technique, we found that changing from medio-lateral to proximal-distal drilling directions did not result in an appreciable biomechanical benefit. LEVEL OF EVIDENCE: Basic science study; Biomechanics.

2.
Ochsner J ; 22(3): 204-210, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36189099

RESUMO

Background: Early (2020) reports on mortality in patients with coronavirus disease 2019 (COVID-19) who underwent orthopedic surgery ranged from 20.5% to 56%, but these studies included elderly patients with multiple comorbidities. The mortality rate for younger and asymptomatic COVID-19-positive patients undergoing orthopedic surgery after high-energy trauma is underreported. The purpose of this study was to compare the 30-day mortality of asymptomatic COVID-19-positive patients and COVID-19-negative patients surgically treated for orthopedic trauma at a Level I trauma center during the coronavirus pandemic. A secondary objective was to compare the patients' postoperative hospital course and length of stay. Methods: This study is a single-center retrospective review of all patients who underwent an orthopedic surgical procedure at a Level I trauma center during a 3-month period early in the COVID-19 pandemic. All patients received a preoperative nasopharyngeal swab to determine COVID-19 infection status. Preoperative demographic variables, perioperative and postoperative mortality within 30 days, length of stay, and intensive care unit days were compared between COVID-19-positive and COVID-19-negative patients. Results: Of the 471 total patients, 13 were COVID-19-positive and 458 were COVID-19-negative prior to surgery. The average age of all patients was 40.5 ± 19.8 years. The mortality rate in the COVID-19-positive group was 0% vs 0.7% in the COVID-19-negative group, with no significant difference between groups (P=0.77). The COVID-19-positive group vs the COVID-19-negative group had no significant difference in hospital length of stay (7.4 days vs 4.4 days, respectively, P=0.12). Conclusion: Asymptomatic COVID-19-positive orthopedic trauma patients treated with surgery at a Level I trauma center in a 3-month period during the COVID-19 pandemic had a 0% mortality rate, and we found no differences between COVID-19-positive and COVID-19-negative patients with respect to mortality and hospital length of stay.

3.
OTA Int ; 5(2): e203, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35919107

RESUMO

Background: Intertrochanteric femur fractures are a common orthopaedic injury that are often treated surgically. Cephalomedullary nails (CMN) are frequently the implant of choice for intertrochanteric femur fractures, resulting in low complication rates. Implant failure is a rare but reported complication. Common locations of failure include the proximal nail aperture, distal screw holes, and implant shaft. In this case report, we describe a CMN failure pattern through fenestrated cephalic screw holes. Case: A 70-year-old female sustained an OTA 31A-2.2 peritrochanteric fracture during a motor vehicle collision. She was treated the following day with a Synthes Trochanteric Fixation Nail-Advanced CMN utilizing a fenestrated cephalic screw. There were no intraoperative complications. She was made non-weight bearing for 8 weeks after the procedure due to ipsilateral foot fractures. At 6 months follow-up she was noted to have a delayed union. 11 months postoperatively she suffered a ground level fall and the cephalic lag screw failed through its fenestrations, resulting in varus collapse of her fracture at the femoral neck. The patient then underwent nail extraction and salvage total hip arthroplasty. Conclusion: Cephalomedullary nail implant failure is presented with implant fracture propagation through a fenestrated cephalic screw. Cephalomedullary lag screw failure is rare and can be difficult to manage. It is important to monitor new implants for unique failure mechanisms.

4.
Orthop Traumatol Surg Res ; 108(4): 103273, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35331920

RESUMO

INTRODUCTION: Pelvic internal fixation has become a popular method for treatment of unstable pelvic ring injuries. Although successful, one complication is femoral nerve palsy from compression of the connecting rod. In light of this complication, this study was designed to evaluate sagittal inclinations of the rod and the feasibility of using a rod with a constant curvature. HYPOTHESIS: It is hypothesized that that there is a connection between the sagittal inclination of the rod and the rod to bone distance, as well as single rod can be contoured with a constant curvature to be used in the majority of all patients. METHODS: Three dimensional models of pelvis CTs from a single level 1 trauma center were created and imported into a program where software superimposed a pre-contoured rod in the sagittal planes upon the pelvic slices. The sagittal inclination was deemed acceptable is no interference occurred between the area of compression risk and the rod. For each pelvis and considered sagittal rod inclination, the rod radius of curvature (ROC), minimal rod to bone distance (RTB) and transverse inclinations (φL and φR) were measured at which the pedicle screws should be inserted to follow the direction of the smallest RTB. RESULTS: The sagittal inclinations feasible for all subjects were between 15° to 30°. In this sagittal range, the average RTB varied in values ranging from 4.0±0.9mm to 25.4±11.4mm (p<0.01). Only 46% of subjects allowed a rod with constant curvature. DISCUSSION AND CONCLUSION: Our study found that a rod to bone distance of 15mm was not safe for all models. As well, many subject models did not allow placement of pre-contoured rod. Patient specific templating of pelvic subcutaneous internal fixation is strictly needed to limit complications. LEVEL OF EVIDENCE: VII; Basic Science.


Assuntos
Fraturas Ósseas , Parafusos Pediculares , Ossos Pélvicos , Traumatismos dos Nervos Periféricos , Fixação Interna de Fraturas/métodos , Fraturas Ósseas/cirurgia , Humanos , Ossos Pélvicos/lesões , Ossos Pélvicos/cirurgia , Pelve
5.
JBJS Case Connect ; 10(3): e19.00564, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32910618

RESUMO

CASE: We report a case of a right knee lateral bucket-handle meniscal tear repair in a 25-year-old woman bilateral below-knee amputee. At the 4-year follow-up, the patient was ambulatory in a prosthesis with a successful outcome. CONCLUSION: Meniscus repair in below-knee amputees requires careful evaluation and surgical management. Specific consideration should be given to evaluating limb alignment, maintaining the stump integrity, surgical technique, modified bracing, and rehabilitation. This case report demonstrates that bucket-handle meniscus repair can be successful in a below-knee amputee.


Assuntos
Amputados , Artroscopia/métodos , Lesões do Menisco Tibial/cirurgia , Adulto , Feminino , Humanos , Imageamento por Ressonância Magnética , Lesões do Menisco Tibial/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...