Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Commun Phys ; 6(1): 82, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37124119

RESUMO

The Extremely Brilliant Source (EBS) is the experimental implementation of the novel Hybrid Multi Bend Achromat (HMBA) storage ring magnetic lattice concept, which has been realised at European Synchrotron Radiation Facility. We present its successful commissioning and first operation. We highlight the strengths of the HMBA design and compare them to the previous designs, on which most operational synchrotron X-ray sources are based. We report on the EBS storage ring's significantly improved horizontal electron beam emittance and other key beam parameters. EBS extends the reach of synchrotron X-ray science confirming the HMBA concept for future facility upgrades and new constructions.

2.
J Synchrotron Radiat ; 21(Pt 5): 986-95, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25177987

RESUMO

Although beamline instrumentation is by nature driven by science, some recent examples serve as reminders that new technologies also enable new science. Indeed, exploiting the full scientific potential of forthcoming new storage rings with unprecedented source characteristics will, in many cases, require the development and implementation of novel instrumentation. In comparison with present synchrotron radiation facilities, the majority of beamlines should reap immediate performance benefits from the improved source emittance, principally through increased flux and/or horizontal beam size reduction at the sample. Instrumentation will have to develop along similar quantitative and qualitative trends. More speculative and more challenging is anticipating instrumentation that will be required by the new science made possible thanks to the unique coherence properties of diffraction-limited storage rings (DLSRs). ESRF has recently carried out a detailed feasibility study for a new ultra-low-emittance 6 GeV hybrid multibend storage ring, identified as ESRF Upgrade Programme Phase II. Although its performance is not expected to be equivalent to a DLSR source, the successful implementation of the ESRF Phase II project has to address scientific instrumentation issues that are also common to DLSRs. This article aims at providing a comprehensive review of some of the challenges encountered by the ESRF, in the context of the preparation of Phase II of its upgrade programme.

3.
Rev Sci Instrum ; 82(2): 025109, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21361635

RESUMO

A low temperature sample environment for x-ray photon correlation spectroscopy measurements in small-angle scattering geometry is presented. The chamber has been designed to allow investigations of dynamical phenomena in supercooled liquids and the typical working temperature range is 110-330 K with a thermal stability ΔT/T down to 10(-4). A variable external magnetic field up to 0.12 T can be applied, which is of interest in studies of, e.g., ferrofluids and liquid crystalline materials. Here, technical details about the sample environment are given together with examples of recent applications.

4.
J Synchrotron Radiat ; 17(1): 107-18, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20029119

RESUMO

The first phase of the ESRF beamline ID23 to be constructed was ID23-1, a tunable MAD-capable beamline which opened to users in early 2004. The second phase of the beamline to be constructed is ID23-2, a monochromatic microfocus beamline dedicated to macromolecular crystallography experiments. Beamline ID23-2 makes use of well characterized optical elements: a single-bounce silicon (111) monochromator and two mirrors in Kirkpatrick-Baez geometry to focus the X-ray beam. A major design goal of the ID23-2 beamline is to provide a reliable, easy-to-use and routine microfocus beam. ID23-2 started operation in November 2005, as the first beamline dedicated to microfocus macromolecular crystallography. The beamline has taken the standard automated ESRF macromolecular crystallography environment (both hardware and software), allowing users of ID23-2 to be rapidly familiar with the microfocus environment. This paper describes the beamline design, the special considerations taken into account given the microfocus beam, and summarizes the results of the first years of the beamline operation.


Assuntos
Biopolímeros/química , Cristalografia por Raios X/instrumentação , Lentes , Síncrotrons/instrumentação , Desenho Assistido por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , França , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
5.
J Synchrotron Radiat ; 13(Pt 3): 227-38, 2006 May.
Artigo em Inglês | MEDLINE | ID: mdl-16645249

RESUMO

The demand for access to macromolecular crystallography synchrotron beam time continues to increase. To meet this demand the ESRF has constructed a dual station beamline using a canted undulator system as the X-ray source. The first phase of the beamline to be constructed is ID23-1, a tunable MAD-capable station with a mini-focus X-ray beam. The beamline makes use of well characterized optical elements: a channel-cut monochromator with a high-precision toroidal mirror to focus the X-ray beam. The beamline has been conceived with the aim of providing high levels of automation to create an industrial-like environment for protein crystallography. A new software suite has been developed to permit reliable easy operation for the beamline users and beamline staff. High levels of diagnostics are built in to allow rapid trouble-shooting. These developments are now being exported to the ESRF macromolecular crystallography beamline complex and have been made in a modular fashion to facilitate transportability to other synchrotrons.


Assuntos
Cristalografia por Raios X/instrumentação , Óptica e Fotônica/instrumentação , Robótica/instrumentação , Síncrotrons/instrumentação , Desenho de Equipamento , França
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...