Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-26773885

RESUMO

An ultra-high performance liquid chromatography/tandem mass spectrometry (UPLC-MS/MS) method for the simultaneous determination of (4S,5R)-5-[3,5-bis (trifluoromethyl)phenyl]-3-{[4'-fluoro-5'-isopropyl-2'-methoxy-4-(trifluoromethyl)biphenyl-2-yl] methyl}-4-methyl-1,3-oxazolidin-2-one (anacetrapib, I) and [(13)C5(15)N]-anacetrapib, II in human plasma has been developed to support a clinical study to determine the absolute bioavailability of I. The analytes and the stable-isotope labeled internal standard ([(13)C7(15)N(2)H7]-anacetrapib, III) were extracted from 100µL of human plasma by liquid-liquid extraction using 20/80 isopropyl alcohol/hexane (v/v). The chromatographic separation of the analytes was achieved using Waters BEH Shield RP 18 (50×2.1mm×1.7µm) column and mobile phase gradient of 0.1% formic acid in water (Solvent A) and 0.1% formic acid in acetonitrile (Solvent B) at 0.6mL/min flow rate. The MS/MS detection was performed on AB Sciex 5000 or AB 5500 in positive electrospray ionization mode, operated in selected reaction monitoring mode. The assay was validated in the concentration range 1-2000ng/mL for I; and a lower curve range, 0.025-50ng/mL for II. In addition to the absolute bioavailability determination, it was desired to better elucidate the pharmacokinetic behavior of several hydroxylated metabolites of I. Toward this end, two exploratory assays for the hydroxy metabolites of I were qualified in the concentration range 0.5-500ng/mL. All metabolites were separated on a Supelco Ascentis Express Phenyl-Hexyl (50×2.1mm, 2.7µm) column. Metabolite M4 was analyzed in the negative mode with a mobile phase consisting of a gradient mixture of water (A) and acetonitrile (B). The other three metabolites, M1-M3 were analyzed in the positive mode using a mobile phase gradient of water with 0.1% formic acid (A) and acetonitrile with 0.1% formic acid (B). The assays were utilized to support a clinical study in which a microdosing approach was used to determine the pharmacokinetics of anacetrapib and its metabolites.


Assuntos
Cromatografia Líquida/métodos , Oxazolidinonas/sangue , Oxazolidinonas/farmacocinética , Espectrometria de Massas em Tandem/métodos , Disponibilidade Biológica , Humanos , Marcação por Isótopo , Modelos Lineares , Oxazolidinonas/química , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
2.
J Chromatogr B Analyt Technol Biomed Life Sci ; 879(17-18): 1457-66, 2011 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-21459053

RESUMO

Sensitive and selective methods based on high performance liquid chromatography (HPLC) with tandem mass spectrometric (MS/MS) detection were developed for the determination of vitamin D(3) in human serum. Derivatization of vitamin D(3) and its stable isotope labeled internal standard provided highly sensitive quantification and selective detection from endogenous compounds. Samples were prepared using the in-tube liquid-liquid extraction (LLE), 96-well plate LLE, and in-tip solid phase micro-extraction (SPME) in 96-well format. In all methods, the MS/MS detection was performed using Applied Biosystems-Sciex API 3000 tandem mass spectrometers interfaced with a heated nebulizer probe and operated in the positive ionization mode. Both tube and plate LLE methods achieved a lower limit of quantitation (LLOQ) of 0.5 ng/mL when 1.0 and 0.4 mL of human serum was processed, respectively, and were validated in the concentration range of 0.5-25 ng/mL; while for the in-tip SPME method, LLOQ was 5 ng/mL with only 0.1 mL of human serum required. Comparisons were made among three different methods, including precision and accuracy, sample throughput, recovery and matrix effects.


Assuntos
Colecalciferol/sangue , Microextração em Fase Sólida/métodos , Espectrometria de Massas em Tandem/métodos , Cromatografia Líquida/métodos , Humanos , Sensibilidade e Especificidade
3.
J Chromatogr B Analyt Technol Biomed Life Sci ; 816(1-2): 297-308, 2005 Feb 25.
Artigo em Inglês | MEDLINE | ID: mdl-15664362

RESUMO

Analytical method for the simultaneous determination of dextromethorphan (1) and dextrorphan (2) in urine, based on solid-phase extraction of drug from acidified hydrolyzed biological matrix, were developed. The analytes (1 and 2) and the internal standard (levallorphan, 3, IS) were detected by high-performance liquid chromatography-mass spectrometry (HPLC-MS/MS) in positive ionization mode using a heated nebulizer (HN) probe and monitoring their precursor-->product ion combinations of m/z 272-->215, 258-->201, and 284-->201 for 1, 2, and 3, respectively, in multiple reaction monitoring mode. The analytes and IS were chromatographed on a Keystone Prism reverse phase (50 mm x 2.0 mm) 5 microm column using a mobile phases consisting of a 35/65 or 27/73 mixtures of methanol/water containing 0.1% TFA adjusted to pH 3 with ammonium hydroxide pumped at 0.4 ml/min for 1 and 2, respectively. The limits of reliable quantification of 1 and 2 were 2 and 250 ng/ml, respectively, when 1 ml of urine was processed. The absence of matrix effect was demonstrated by analysis of neat standards and standards spiked into urine extracts originating from five different sources. The linear ranges of the assay were 2-200 and 250-20,000 ng/ml for 1 and 2, respectively. Assay selectivity was evaluated by monitoring the "cross-talk" effects from other metabolites into the MS/MS channels used for monitoring 1, 2, and 3. In addition, an interfering peak originating from an unknown metabolite of 1 into the quantification of dextromethorphan was detected, requiring an effective chromatographic separation of analytes from other metabolites of 1. The need for careful assessment of selectivity of the HPLC-MS/MS assay in the presence of metabolites, and the assessment of matrix effect, are emphasized.


Assuntos
Antitussígenos/metabolismo , Cromatografia Líquida de Alta Pressão/métodos , Dextrometorfano/urina , Dextrorfano/urina , Espectrometria de Massas/métodos , Estabilidade de Medicamentos , Congelamento , Humanos , Reprodutibilidade dos Testes
4.
J Pharm Biomed Anal ; 35(5): 1213-29, 2004 Sep 03.
Artigo em Inglês | MEDLINE | ID: mdl-15336366

RESUMO

A method for the simultaneous determination of Aprepitant, I (5-[[2(R)-[1(R)-(3,5-bistrifluoromethylphenyl)ethoxy]-3(S)-(4-fluorophenyl) morpholin-4-yl]methyl]-2,4-dihydro-[1,2,4]triazol-3-one) and two active metabolites (II and III) in human plasma has been developed. The method was based on high-performance liquid chromatography (HPLC) with atmospheric pressure chemical ionization tandem mass spectrometric (APCI-MS-MS) detection in positive ionization mode using a heated nebulizer interface. The analytes and internal standard (IV) (Fig. 1) were isolated from basified plasma using liquid-liquid extraction. The organic extracts were dried, reconstituted in mobile phase and injected into the HPLC-MS/MS system. The analytes were chromatographed on a narrow bore (50 mm x 2.0 mm, 3 microm) Keystone Scientific's Prism R.P. analytical column, with mobile phase consisting of acetonitrile (ACN):water containing trifluoroacetic acid with pH adjusted to 3 (40:60, v/v) pumped at a flow rate of 0.5 ml/min. The MS-MS detection was performed on a Sciex API 3000 tandem mass spectrometer operated in selected reaction monitoring mode. The precursor-->product ion combinations of m/z 535-->277, 438-->180, 452-->223 and 503-->259 were used to quantify I, II, III, and IV, respectively, after chromatographic separation of the analytes. The assay was validated in the concentration range of 10-5000 ng/ml for I and II and 25-5000 ng/ml for III when 1 ml of plasma was processed. The precision of the assay (expressed as coefficient of variation, CV) was less than 10% at all concentrations within the standard curve range, with adequate assay accuracy. Matrix effect experiments were performed to demonstrate the absence of any significant change in ionization of the analytes when comparing neat standards to analytes in the presence of plasma matrix. This assay was utilized to support a clinical study where multiple oral doses of I were administered to healthy subjects to investigate the pharmacokinetics, safety, and tolerability of Aprepitant. Concentrations of the two most active metabolites, which if present in high concentrations would increase the neurokinin-1 (NK1) receptor occupancy level and therefore potentially contribute to the antiemetic action of Aprepitant, were determined.


Assuntos
Morfolinas/sangue , Antieméticos/sangue , Antieméticos/metabolismo , Aprepitanto , Cromatografia Líquida de Alta Pressão/métodos , Estabilidade de Medicamentos , Armazenamento de Medicamentos , Congelamento , Humanos , Espectrometria de Massas/métodos , Estrutura Molecular , Morfolinas/metabolismo
5.
Artigo em Inglês | MEDLINE | ID: mdl-15203036

RESUMO

Methods based on high-performance liquid chromatography (HPLC) with atmospheric-pressure chemical ionization (APCI) mass spectrometric (MS) detection using either single (MS) or triple (MS/MS) quadrupole mass spectrometric detection for the determination of (2R)-[1(R)-(3,5-bis-trifluoromethylphenyl)ethoxy]-3(S)-(4-fluoro-phenyl)morpholin-4-ylmethyl]-5-oxo-4,5-dihydro-[1,2,4]triazol)methyl morpholine (Aprepitant, Fig. 1) in human plasma has been developed. Aprepitant (I) and internal standard (II, Fig. 1) were isolated from the plasma matrix buffered to pH 9.8 using a liquid-liquid extraction with methyl-t-butyl ether (MTBE). The analytes were separated on a Keystone Scientific's Javelin BDS C-8 2 mm x 4.6 mm 3 microm guard column coupled to BDS C-8 50 mm x 4.6 mm 3 microm analytical column, utilizing a mobile phase of 50% acetonitrile and 50% water containing 0.1% formic acid and 10 mM ammonium acetate delivered at a flow rate of 1 ml/min. The single quadrupole instrument was operated in a single ion monitoring (SIM) mode analyzing the protonated molecules of Aprepitant and II at m/z 535 and 503, respectively. The triple quadrupole mass spectrometer was operated in multiple reaction monitoring mode (MRM) monitoring the precursor --> ion combinations of m/z 535 --> 277 and 503 --> 259 for Aprepitant and II, respectively. The linear calibration range for both single and triple quadrupole detectors was from 10 to 5000 ng/ml of plasma with coefficients of variation less than 8% at all concentrations. Both single and triple quadrupole instruments yielded similar precision and accuracy results. Matrix effect experiments performed on both instruments demonstrated the absence of any significant change in ionization of the analytes when comparing neat standards to analytes in the presence of plasma matrix. Both instruments were used successfully to support numerous clinical trials of Aprepitant.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Espectrometria de Massas/instrumentação , Morfolinas/sangue , Substância P/antagonistas & inibidores , Aprepitanto , Pressão Atmosférica , Humanos , Espectrometria de Massas/métodos , Padrões de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
6.
Artigo em Inglês | MEDLINE | ID: mdl-15113535

RESUMO

Sensitive methods based on capillary gas chromatography (GC) with mass spectrometric (MS) detection in a selected-ion monitoring mode (SIM) for the determination of a cyclooxygenase II (COX-II) inhibitor (3-isopropoxy-4-(4-methanesulfonylphenyl)-5,5'-dimethyl-5H-furan-2-one, I) in human plasma, in two concentration ranges of 0.1-20 and 5-1000 ng/ml, are described. Following liquid-liquid extraction, the residue, after evaporation of the organic phase to dryness, was reconstituted in acetonitrile (20 l) and part of the extract (1 l) was analyzed by GC/MS/SIM. The drug (I) and internal standard (II) were separated on a 25 mx0.2 mm capillary column with HP Ultra 1 (100% dimethylpolysiloxane, 0.33 m) phase and analyzed by MS/SIM monitoring ions at m/z 237 and 282 for I and II, respectively. The standard curve was linear within the lower concentration range of 0.1-20 ng/ml and the lower limit of quantification (LLOQ) in plasma was 0.1 ng/ml. Intraday coefficients of variation (CV, n=5) were 8.9, 4.2, 5.7, 3.1, 1.9, 1.9, and 4.4% at 0.1, 0.2, 0.5, 1.0, 5.0, 10, and 20 ng/ml, respectively. The standard curve was also linear within the higher concentration range of 5-1000 ng/ml and the LLOQ in plasma was 5 ng/ml. Intraday coefficients of variation (CV, n=5) were all below 9% at all concentrations within the standard curve range. The accuracy for I in human plasma was 91-112% and the recovery of I and II was greater than 70% at all concentrations within both standard curve ranges. The details of the assay methodology are presented.


Assuntos
Inibidores de Ciclo-Oxigenase/sangue , Furanos/sangue , Cromatografia Gasosa-Espectrometria de Massas/métodos , Humanos , Padrões de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
7.
Anal Chem ; 75(13): 3019-30, 2003 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-12964746

RESUMO

In recent years, high-performance liquid chromatography (HPLC) with tandem mass spectrometric (MS/MS) detection has been demonstrated to be a powerful technique for the quantitative determination of drugs and metabolites in biological fluids. However, the common and early perception that utilization of HPLC-MS/MS practically guarantees selectivity is being challenged by a number of reported examples of lack of selectivity due to ion suppression or enhancement caused by the sample matrix and interferences from metabolites. In light of these serious method liabilities, questions about how to develop and validate reliable HPLC-MS/MS methods, especially for supporting long-term human pharmacokinetic studies, are being raised. The central issue is what experiments, in addition to the validation data usually provided for the conventional bioanalytical methods, need to be conducted to confirm HPLC-MS/MS assay selectivity and reliability. The current regulatory requirements include the need for the assessment and elimination of the matrix effect in the bioanalytical methods, but the experimental procedures necessary to assess the matrix effect are not detailed. Practical, experimental approaches for studying, identifying, and eliminating the effect of matrix on the results of quantitative analyses by HPLC-MS/MS are described in this paper. Using as an example a set of validation experiments performed for one of our investigational new drug candidates, the concepts of the quantitative assessment of the "absolute" versus "relative" matrix effect are introduced. In addition, experiments for the determination of, the "true" recovery of analytes using HPLC-MS/MS are described eliminating the uncertainty about the effect of matrix on the determination of this commonly measured method parameter. Determination of the matrix effect allows the assessment of the reliability and selectivity of an existing HPLC-MS/MS method. If the results of these studies are not satisfactory, the parameters determined may provide a guide to what changes in the method need to be made to improve assay selectivity. In addition, a direct comparison of the extent of the matrix effect using two different interfaces (a heated nebulizer, HN, and ion spray, ISP) under otherwise the same sample preparation and chromatographic conditions was made. It was demonstrated that, for the investigational drug under study, the matrix effect was clearly observed when ISP interface was utilized but it was absent when the HN interface was employed.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Espectrometria de Massas/métodos , Humanos , Espectrometria de Massas/instrumentação , Plasma/química , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
8.
J Pharm Biomed Anal ; 28(5): 925-34, 2002 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-12039635

RESUMO

Methods for the quantitative determination of efavirenz in human plasma and the qualitative assessment of the stereochemical integrity of efavirenz in post-dose human plasma samples are described. After the addition of an internal standard, plasma samples were extracted with hexane-methylene chloride (65/35, v/v%). The extracts were evaporated to dryness and reconstituted in mobile phase. Upon exposure to UV light, the analyte was found to form fluorescent products; the major fluorescent product was isolated and identified as a substituted quinoline. Thus, the plasma extracts were analyzed via HPLC with post-column photochemical derivatization and fluorescence detection. Reverse phase chromatography was used for the quantitative assay, whereas chromatography with a column containing a chiral stationary phase (dinitrobenzoyl leucine) was used for the stereochemical assessment. The quantitative assay has been validated in the concentration range of 50-1000 ng/ml using 0.5 ml samples. Analyte recovery was better than 89% at all points on the standard curve. Intra-day precision was better than 5% C.V., while accuracy was between 95 and 104% of nominal over the range of the assay. The selective detection method reduces the likelihood of interference by co-administered medications or endogenous species. The stereochemical configuration of efavirenz was confirmed to remain intact in post-dose human plasma samples. The quantitative method has been successfully utilized to support a study in which a possible drug interaction between co-administered HIV protease inhibitors and efavirenz was evaluated.


Assuntos
Oxazinas/sangue , Inibidores da Transcriptase Reversa/sangue , Alcinos , Benzoxazinas , Cromatografia Líquida de Alta Pressão , Ciclopropanos , Humanos , Indicadores e Reagentes , Espectroscopia de Ressonância Magnética , Oxazinas/farmacocinética , Fotoquímica , Fotólise , Controle de Qualidade , Inibidores da Transcriptase Reversa/farmacocinética , Espectrometria de Fluorescência , Espectrofotometria Ultravioleta , Estereoisomerismo
9.
Artigo em Inglês | MEDLINE | ID: mdl-11863283

RESUMO

A method for the simultaneous determination of a cyclooxygenase-2 inhibitor, 4-(4-methanesulfonylphenyl)-3-phenyl-5H-furan-2-one (rofecoxib, I) and [13C7]rofecoxib, (II), in human plasma has been developed to support the clinical oral bioavailability (BA) study of I. The method is based on high-performance liquid chromatography (HPLC) with atmospheric pressure chemical ionization tandem mass spectrometric (APCI-MS-MS) detection in the negative ionization mode using a heated nebulizer interface. Two different stable isotope labeled analogs of I were initially evaluated for their use as intravenous (i.v.) markers in the BA study. [13CD3]Rofecoxib was shown to be isotopically unstable in plasma and water containing solvent and an efficient deuterium exchange prevented its use in the study. On the other hand, the isotopic integrity of the subsequently synthesized [13C7]rofecoxib (II) was maintained, as expected, in plasma and other solvent systems. The results of these experiments clearly demonstrated the need for the careful evaluation of the isotopic integrity of the stable isotope labeled compound for the successful utilization of these compounds in BA studies and also as internal standards in the quantitative analysis of drugs in biological fluids. After liquid-liquid extraction of I, II, and internal standard (III) from plasma, the analytes were chromatographed on a narrow bore (100 mm x 3.0 mm) C18 analytical column, with mobile phase consisting of acetonitrile-water (1:1, v/v) at a flow-rate of 0.5 ml/min. The MS-MS detection was performed on a PE Sciex API III Plus tandem mass spectrometer operated in the selected reaction monitoring mode. The precursor-->product ion combinations of m/z 313-->257, 320-->292, and 327-->271 were used to quantify I, II, and III, respectively. The assay was validated in the concentration range of 0.1 to 100 ng/ml of plasma for both I and II. The precision of the assay (expressed as relative standard deviation) was less than 10% at all concentrations within the standard curve range, with adequate assay accuracy. The assay was utilized to support the clinical BA study in which oral doses of I were administered together with an i.v. dose of II to determine the oral BA of rofecoxib at 12.5- and 25-mg doses.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Inibidores de Ciclo-Oxigenase/sangue , Lactonas/sangue , Espectrometria de Massas/métodos , Administração Oral , Disponibilidade Biológica , Isótopos de Carbono , Inibidores de Ciclo-Oxigenase/administração & dosagem , Inibidores de Ciclo-Oxigenase/farmacocinética , Lactonas/administração & dosagem , Lactonas/farmacocinética , Padrões de Referência , Reprodutibilidade dos Testes , Sulfonas
10.
Drug Metab Dispos ; 29(12): 1614-28, 2001 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-11717181

RESUMO

Rofecoxib is a potent and highly selective cyclooxygenase-2 inhibitor used for the treatment of osteoarthritis and pain. Following administration of [4-(14)C]rofecoxib to intact rats, the plasma C(max) (at approximately 1 h) was followed by a secondary C(max) (at approximately 10 h), which was not observed in bile duct-cannulated rats. Following administration of [4-(14)C]5-hydroxyrofecoxib to intact or bile duct-cannulated rats, radiolabeled rofecoxib was detected in plasma, and once again a secondary C(max) for rofecoxib was observed (at approximately 10 h), which occurred only in the intact animals. These results indicate that reversible metabolism of rofecoxib to 5-hydroxyrofecoxib occurs in the rat and that the process is dependent upon an uninterrupted bile flow. Studies on the contents of the gastrointestinal tract of rats showed that conversion of 5-hydroxyrofecoxib to parent compound occurs largely in the lower intestine. Treatment of rats with [5-(18)O]5-hydroxyrofecoxib, followed by liquid chromatography-tandem mass spectrometry analyses of plasma samples, confirmed that 5-hydroxyrofecoxib undergoes metabolism to the parent drug, yielding [1-(18)O]rofecoxib, [2-(18)O]rofecoxib, and unlabeled rofecoxib. Similarly, treatment with [1,2-(18)O(2)]rofecoxib afforded the same three isotopic variants of rofecoxib. These findings are consistent with a metabolic sequence involving 5-hydroxylation of rofecoxib, biliary elimination of the corresponding glucuronide, and deconjugation of the glucuronide in the lower gastrointestinal tract. Reduction of the 5-hydroxyrofecoxib thus liberated yields a hydroxyacid that cyclizes spontaneously to regenerate rofecoxib, which is reabsorbed and enters the systemic circulation. This sequence represents a novel form of enterohepatic recycling and reflects the susceptibility of 5-hydroxyrofecoxib, as well as rofecoxib itself, to reversible 2-furanone ring opening under in vivo conditions.


Assuntos
Inibidores de Ciclo-Oxigenase/farmacocinética , Lactonas/metabolismo , Lactonas/farmacocinética , Animais , Bile/metabolismo , Biotransformação , Radioisótopos de Carbono , Cromatografia Líquida de Alta Pressão , Furanos/metabolismo , Absorção Intestinal , Marcação por Isótopo , Espectroscopia de Ressonância Magnética , Masculino , Isótopos de Oxigênio , Ratos , Ratos Sprague-Dawley , Sulfonas , Distribuição Tecidual
11.
J Chromatogr B Biomed Sci Appl ; 748(1): 31-9, 2000 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-11092584

RESUMO

A method for the determination of 4-(4-methanesulfonylphenyl)-3-phenyl-5H-furan-2-one (Rofecoxib, Vioxx, MK-0966, I) a cyclooxygenase-2 inhibitor, in human plasma has been developed. The method is based on high-performance liquid chromatography (HPLC) with atmospheric pressure chemical ionization tandem mass spectrometric (APCI-MS-MS) detection in negative ionization mode using a heated nebulizer interface. Drug and internal standard (II) were isolated from basified plasma using liquid-liquid extraction. The organic extracts were dried, reconstituted in mobile phase and injected into the HPLC-MS-MS system. Compounds I and II were chromatographed on a narrow bore (100 mm x 3.0 mm) C18 analytical column, with mobile phase consisting of acetonitrile:water (1:1, v/v) at a flow-rate of 0.4 ml/min. The MS-MS detection was performed on a PE-Sciex API III Plus tandem mass spectrometer operated in selected reaction monitoring mode. The parent-->product ion combinations of m/z 313-->257 and 327-->271 were used to quantify I and II, respectively, after chromatographic separation of the analytes. The assay was validated in the concentration range of 0.1 to 100 ng/ml of plasma. The precision of the assay (expressed as coefficient of variation) was less than 10% at all concentrations within the standard curve range, with adequate assay accuracy. The effect of HPLC mobile phase components on the ionization efficiency and sensitivity of detection in the positive and negative ionization modes, and the detailed description of all necessary steps involved in the assay for I in plasma are presented.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Inibidores de Ciclo-Oxigenase/sangue , Lactonas/sangue , Espectrometria de Massas/métodos , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Sulfonas
12.
J Chromatogr B Biomed Sci Appl ; 721(2): 229-38, 1999 Jan 22.
Artigo em Inglês | MEDLINE | ID: mdl-10052695

RESUMO

Methods for the determination of a semi-synthetic cyclic hexapeptide (I, MK-0991) in human plasma based on high-performance liquid chromatography (HPLC) with tandem mass spectrometric (MS-MS) detection using pneumatically assisted electrospray (ion spray, ISP) and turbo ion spray (TISP) interfaces were developed. Drug and internal standard (II, an isostere of I) were isolated from plasma by solid-phase extraction (SPE). The eluent from SPE was evaporated to dryness, the residue was reconstituted in mobile phase and injected into the HPLC system. The use of ISP, TISP and heated nebulizer (HN) interfaces as sample introduction systems were evaluated and showed that the heated nebulizer was not adequate for analysis due to thermal instability and/or adsorption of I and II to glass surfaces of the interface. Compounds I and II were chromatographed on a wide pore (300 A), 150x4.6 mm C8 analytical column, and the HPLC flow-rate of 1.2 ml/min was split 1:20 prior to introduction to the ISP or TISP interface of the mass spectrometric system. The MS-MS detection was performed on a PE Sciex API III Plus tandem mass spectrometer operated in selected reaction monitoring mode (SRM). The precursor-->product ion combinations of m/z 1093.7-->1033.6 and 1094.7-->1033.6 were used to quantify I and II, respectively, after chromatographic separation of the analytes. The assay was validated in the concentration range of 10-1000 ng/ml using ISP, and 2.5-500 ng/ml of plasma using TISP with good precision and adequate accuracy. The effects of HPLC mobile-phase components on the ionization efficiency and sensitivity of detection in the positive ionization mode, the evaluation of the matrix effect, and limitations in sensitivity of detection of I due to the formation of multiply charged species are presented.


Assuntos
Antibacterianos/sangue , Antifúngicos/sangue , Peptídeos Cíclicos , Peptídeos , Calibragem , Caspofungina , Cromatografia Líquida de Alta Pressão , Equinocandinas , Humanos , Lipopeptídeos , Espectrometria de Massas , Padrões de Referência , Reprodutibilidade dos Testes
13.
J Chromatogr B Biomed Sci Appl ; 716(1-2): 195-208, 1998 Sep 25.
Artigo em Inglês | MEDLINE | ID: mdl-9824233

RESUMO

The purpose of this work was to develop HPLC-MS-MS methods for the quantification of L-368,899 (1) in human plasma and urine and to evaluate the selectivity of these methods in post-dose samples in the presence of metabolites. Assays were based on double liquid-liquid extraction of the drug and internal standard (I.S., 2) from basified plasma, evaporation of the extracts to dryness, derivatization of the primary amino groups of 1 and 2 with trifluoroacetic anhydride (TFAA) to form trifluoroacetylated (TFA) analogs, and HPLC analysis using tandem mass spectrometer equipped with the heated nebulizer interface as a detector. The derivatization with TFAA was required to eliminate the carryover and adsorption problems encountered when underivatized molecules were chromatographed, and allowed quantitation at low concentration (0.5 ng/ml) in plasma and urine. Initially, assays in control human plasma and urine were validated in the concentration range of 0.5-75 ng/ml, using simplified chromatographic conditions with a 2-min run-time and no separation of the drug from I.S.. Quantitation was based on the high selectivity of detection and multiple reaction monitoring (MRM) using the precursor-->product ion combinations of m/z 651-->152 and m/z 665-->425 for the TFA-derivatized 1 and 2, respectively. However, when selected post-dose urine samples from a clinical study were analyzed using this assay, the area of the I.S. peak was 4 to 7 times larger than the area of I.S. peak in pre-dose urines, indicating the presence of metabolites giving rise to the m/z 665-->425 I.S. peak. A number of metabolites contributing to the I.S. ion pair were separated from 1 and 2 using a longer analytical column, a weaker mobile phase, and by extending the HPLC run-time to 12 min. Under these new conditions, the modified assays both in plasma and urine were validated in the concentration range of 0.5 to 75.0 ng/ml. These assays were selective in the post-dose urine samples in the presence of metabolites.


Assuntos
Canfanos/sangue , Canfanos/urina , Cromatografia Líquida de Alta Pressão/métodos , Espectrometria de Massas/métodos , Piperazinas/sangue , Piperazinas/urina , Receptores de Ocitocina/antagonistas & inibidores , Anidridos Acéticos , Animais , Canfanos/metabolismo , Cães , Fluoracetatos , Humanos , Piperazinas/metabolismo , Controle de Qualidade , Sensibilidade e Especificidade
14.
J Chromatogr B Biomed Sci Appl ; 713(2): 371-8, 1998 Aug 25.
Artigo em Inglês | MEDLINE | ID: mdl-9746252

RESUMO

A sensitive and specific assay of human plasma for the determination of (5alpha,7beta,16beta)-16[(4-chlorophenyl)oxy]-4,7- dimethyl-4-aza-androstan-3-one (I), a selective inhibitor of human type 1 5alpha-reductase, has been developed. The method is based on high-performance liquid chromatography (HPLC) with tandem mass spectrometric (MS-MS) detection. The analyte (I) and internal standard, Proscar (II), were isolated from the basified biological matrix using a liquid-liquid extraction with methyl-tert.-butyl ether (MTBE). The organic extract was evaporated to dryness, the residue was reconstituted in mobile phase and injected into the HPLC system. The MS-MS detection was performed on a PE Sciex API III Plus tandem mass spectrometer using a heated nebulizer interface. Multiple reaction monitoring using the precursor-->product ion combinations of m/z 430-->114 and 373-->305 was used to quantify I and internal standard (II), respectively. The assay was validated in the concentration range of 0.5 to 500 ng/ml in human plasma. The precision of the assay, expressed as coefficient of variation (C.V.), was less than 7% over the entire concentration range, with adequate assay specificity and accuracy. The HPLC-MS-MS method provided sufficient sensitivity to completely map the 24 h pharmacokinetic time-course following a single 0.5 mg dose of I.


Assuntos
Azasteroides/sangue , Di-Hidrotestosterona/análogos & derivados , Inibidores Enzimáticos/sangue , Oxirredutases/antagonistas & inibidores , Azasteroides/farmacologia , Colestenona 5 alfa-Redutase , Cromatografia Líquida de Alta Pressão , Di-Hidrotestosterona/sangue , Di-Hidrotestosterona/farmacologia , Inibidores Enzimáticos/farmacologia , Humanos , Isoenzimas/antagonistas & inibidores , Espectrometria de Massas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
15.
Anal Chem ; 70(5): 882-9, 1998 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-9511465

RESUMO

Contrary to common perceptions, the reliability of quantitative assays for the determination of drugs in biological fluids using high-performance liquid chromatography with tandem mass spectrometric (LC/MS/MS) detection methods and the integrity of resulting pharmacokinetic data may not be absolute. Results may be adversely affected by lack of specificity and selectivity due to ion suppression caused by the sample matrix, interferences from metabolites, and "cross-talk" effects. In this paper, an example of the effect of the sample matrix on the determination of finasteride (I) in human plasma is presented. The ion suppression effect was studied by analyzing standards of I injected directly in mobile phase and comparing the response (peak areas) of I and an internal standard (II) with the peak areas of the same analytes spiked before extraction into five different plasma pools and standards spiked into the plasma extracts after extraction. The LC/MS/MS analyses were performed using a turbo ion spray interface (TISP) under chromatographic conditions, characterized by minimal (total run time of 2 min, capacity factors, k' of 1.50 and 1.75 for I and II, respectively) and high retention of the analytes (total run time 6 min, k' of 3.25 and 13.25 for I and II, respectively). The absolute peak areas for I and II in different plasmas were calculated, and the slopes and peak area ratios at all concentrations within the standard curve ranges were compared. When analyses were performed under conditions of minimal HPLC retention, the slope of the standard line for one set of plasma samples was substantially different (about 50% higher) from that from other plasma sources. The precision of the assay, expressed as coefficient of variation (CV, %) was also inadequate and varied from 15 to 30% at all concentrations within the standard curve range. When the same experiments were repeated using high HPLC retention, the slopes from different plasma sources were practically the same, and the CV was improved to 6-14%. By increasing k' and providing more chromatographic retention of analytes, the "unseen" interferences from plasma matrix were mostly separated from analytes, practically eliminating the ion suppression. In addition, by eliminating from plasma extracts a number of endogenous components through more selective extraction, the ion suppression was also minimized. The detailed data and the design of these experiments are presented. In addition, development of a highly sensitive assay for I in human plasma at low picogram per milliliter concentrations using LC/MS/MS with a heated nebulizer (HN) interface, instead of a TISP interface, is described. In this case, the effects of sample matrixes were not observed.


Assuntos
Inibidores Enzimáticos/sangue , Finasterida/sangue , Cromatografia Líquida de Alta Pressão , Cromatografia Líquida/métodos , Humanos , Masculino , Espectrometria de Massas/métodos , Hiperplasia Prostática/sangue , Reprodutibilidade dos Testes
16.
J Chromatogr B Biomed Sci Appl ; 693(1): 131-7, 1997 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-9200526

RESUMO

A sensitive and specific method for the determination of N-[1(R)¿[1,2-dihydro-1-methylsulfonylspiro(3H-indole-3,4'-piper idin)-1'-yl]carbonyl¿-2-(phenylmethoxy)ethyl]-2-amino-2-meth ylpropanamide (MK-677, I), a growth hormone secretagogue, has been developed. The method is based on high-performance liquid chromatography (HPLC) with tandem mass spectrometric (MS-MS) detection. The analyte and internal standard (II) were isolated from the basified plasma using a liquid-liquid extraction with methyl-tert.-butyl ether (MTBE). The organic extract was evaporated to dryness, the residue was reconstituted in mobile phase and injected into the HPLC system. The MS-MS detection was performed on a PE Sciex API III Plus tandem mass spectrometer using a heated nebulizer interface. Multiple reaction monitoring of parent-->product ion combinations at m/z 529-->267 and 527-->267 was used to quantify I and II, respectively. The assay was validated in human plasma in the concentration range of 0.1 to 100 ng/ml, and the limit of quantification (LOQ) was 0.1 ng/ml. The precision of the assay, as expressed as coefficients of variation (C.V.,%) was less than 7% at all concentrations within the standard curve range, with adequate assay specificity and accuracy. The HPLC-MS-MS method provided sufficient sensitivity to completely map the pharmacokinetic time-course following a single 5-mg oral dose of I.


Assuntos
Hormônio do Crescimento Humano/metabolismo , Indóis/sangue , Compostos de Espiro/sangue , Cromatografia Líquida , Humanos , Indóis/farmacocinética , Espectrometria de Massas , Sensibilidade e Especificidade , Compostos de Espiro/farmacocinética
17.
J Chromatogr B Biomed Sci Appl ; 691(1): 77-85, 1997 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-9140760

RESUMO

A sensitive and specific assay for the determination of 3-[[4-(4-chlorophenyl)piperazin-1-yl]methyl]-1H-pyrrolo[2,3-b]p yri dine (I, L-745,870), a potential antipsychotic agent, has been developed, utilizing high-performance liquid chromatography (HPLC) with tandem mass spectrometric (MS-MS) detection. The analyte and the internal standard (II, 3-[[4-(4-trifluoromethyl)piperazin-1-yl]methyl]-1H-pyrrolo[2,3-b] pyridine) were isolated from a basified biological matrix using liquid-liquid extraction with methyl-tert.-butyl ether. The organic extract was evaporated to dryness, the residue was reconstituted in a mobile phase and injected into the HPLC system. The chromatographic conditions used for the analysis were a Keystone Scientific C18 BDS 150 x 4.6 mm, 5 microns column with a mobile phase consisting of a 40:60 (v/v) mixture of acetonitrile and water containing 10 mM ammonium acetate and 0.1% formic acid pumped at a flow-rate of 1.2 ml/min, yielding retention times of 3.4 and 5.0 min for I and II, respectively. The MS-MS detection was performed on a PE Sciex API III Plus tandem mass spectrometer using a heated nebulizer interface. Multiple reaction monitoring using the parent-->product ion combinations of m/z 327-->131 and 361-->131 were utilized to quantitate I and II, respectively. The assays were validated in the concentration range of 0.1 to 100 and 0.5 to 500 ng/ml for plasma and urine, respectively. The precision of the assays, expressed as coefficients of variation were less than 10% over the entire concentration range, with adequate assay accuracy, sensitivity and specificity to determine the pharmacokinetics in human subjects following a single 1-mg dose.


Assuntos
Antipsicóticos , Cromatografia Líquida de Alta Pressão/métodos , Antagonistas dos Receptores de Dopamina D2 , Espectrometria de Massas/métodos , Piridinas/sangue , Piridinas/urina , Pirróis/sangue , Pirróis/urina , Humanos , Microquímica , Receptores de Dopamina D4 , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...