Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Magn Reson Imaging ; 53(2): 437-444, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-32918328

RESUMO

BACKGROUND: Charcot-Marie-Tooth (CMT) disease is diagnosed through clinical findings and genetic testing. While there are neurophysiological tools and clinical functional scales in CMT, objective disease biomarkers that can facilitate in monitoring disease progression are limited. PURPOSE: To investigate the utility of diffusion tensor imaging (DTI) in determining the microstructural integrity of sciatic and peroneal nerves and its correlation with the MRI grading of muscle atrophy severity and clinical function in CMT as determined by the CMT neuropathy score (CMTNS). STUDY TYPE: Prospective case-control. SUBJECTS: Nine CMT patients and nine age-matched controls. FIELD STRENGTH/SEQUENCE: 3 T T1 -weighted in-/out-of phase spoiled gradient recalled echo (SPGR) and DTI sequences. ASSESSMENT: Fractional anisotropy (FA), axial diffusivity (AD), radial diffusivity (RD), and mean diffusivity (MD) values for sciatic and peroneal nerves were obtained from DTI. Muscle atrophy was graded according to the Goutallier classification using in-/out-of phase SPGRs. DTI parameters and muscle atrophy grades were compared between CMT and controls, and the relationship between DTI parameters, muscle atrophy grades, and CMTNS were assessed. STATISTICAL TESTS: The Wilcoxon Signed Ranks test was used to compare DTI parameters between CMT and controls. The relationship between DTI parameters, muscle atrophy grades, and CMTNS were analyzed using the Spearman correlation. Receiver operating characteristic (ROC) analyses of DTI parameters that can differentiate CMT from healthy controls were done. RESULTS: There was a significant reduction in FA and increase in RD of both nerves (P < 0.05) in CMT, with significant correlations between FA (negative; P < 0.05) and RD (positive; P < 0.05) with muscle atrophy grade. In the sciatic nerve, there was significant correlation between FA and CMTNS (r = -0.795; P < 0.05). FA and RD could discriminate CMT from controls with high sensitivity (77.8-100%) and specificity (88.9-100%). DATA CONCLUSION: There were significant differences of DTI parameters between CMT and controls, with significant correlations between DTI parameters, muscle atrophy grade, and CMTNS. Level of Evidence 2 Technical Efficacy Stage 2 J. MAGN. RESON. IMAGING 2021;53:437-444.


Assuntos
Doença de Charcot-Marie-Tooth , Imagem de Tensor de Difusão , Anisotropia , Doença de Charcot-Marie-Tooth/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética , Nervos Periféricos/diagnóstico por imagem , Estudos Prospectivos
2.
Int J Hyperthermia ; 36(1): 554-561, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31132888

RESUMO

Purpose: This study aimed to evaluate the effects of various computed tomography (CT) acquisition parameters and metal artifacts on CT number measurement for CT thermometry during CT-guided thermal ablation. Methods: The effects of tube voltage (100-140 kVp), tube current (20-250 mAs), pitch (0.6-1.5) and gantry rotation time (0.5, 1.0 s) as well as metal artifacts from a radiofrequency ablation (RFA) needle on CT number were evaluated using liver tissue equivalent polyacrylamide (PAA) phantom. The correlation between CT number and temperature from 37 to 80 °C was studied on PAA phantom using optimum CT acquisition parameters. Results: No statistical significant difference (p > 0.05) was found on CT numbers under the variation of different acquisition parameters for the same temperature setting. On the other hand, the RFA needle has induced metal artifacts on the CT images of up to 8 mm. The CT numbers decreased linearly when the phantom temperature increased from 37 to 80 °C. A linear regression analysis on the CT numbers and temperature suggested that the CT thermal sensitivity was -0.521 ± 0.061 HU/°C (R2 = 0.998). Conclusion: CT thermometry is feasible for temperature assessment during RFA with the current CT technology, which produced a high CT number reproducibility and stable measurement at different CT acquisition parameters. Despite being affected by metal artifacts, the CT-based thermometry could be further developed as a tissue temperature monitoring tool during CT-guided thermal ablation.


Assuntos
Resinas Acrílicas/química , Ablação por Radiofrequência/métodos , Termometria/métodos , Tomografia Computadorizada por Raios X/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...