Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 49
Filtrar
1.
Expert Opin Ther Targets ; : 1-16, 2024 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-38700451

RESUMO

INTRODUCTION: The cardiac conduction system (CCS) is crucial for maintaining adequate cardiac frequency at rest and modulation during exercise. Furthermore, the atrioventricular node and His-Purkinje system are essential for maintaining atrioventricular and interventricular synchrony and consequently maintaining an adequate cardiac output. AREAS COVERED: In this review article, we examine the anatomy, physiology, and pathophysiology of the CCS. We then discuss in detail the most common genetic mutations and the molecular mechanisms of cardiac conduction disease (CCD) and provide our perspectives on future research and therapeutic opportunities in this field. EXPERT OPINION: Significant advancement has been made in understanding the molecular mechanisms of CCD, including the recognition of the heterogeneous signaling at the subcellular levels of sinoatrial node, the involvement of inflammatory and autoimmune mechanisms, and the potential impact of epigenetic regulations on CCD. However, the current treatment of CCD manifested as bradycardia still relies primarily on cardiovascular implantable electronic devices (CIEDs). On the other hand, an If specific inhibitor was developed to treat inappropriate sinus tachycardia and sinus tachycardia in heart failure patients with reduced ejection fraction. More work is needed to translate current knowledge into pharmacologic or genetic interventions for the management of CCDs.

2.
Europace ; 26(5)2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38646912

RESUMO

AIMS: Traditional atrial fibrillation (AF) recurrence after catheter ablation is reported as a binary outcome. However, a paradigm shift towards a more granular definition, considering arrhythmic or symptomatic burden, is emerging. We hypothesize that ablation reduces AF burden independently of conventional recurrence status in patients with persistent AF, correlating with symptom burden reduction. METHODS AND RESULTS: Ninety-eight patients with persistent AF from the DECAAF II trial with pre-ablation follow-up were included. Patients recorded daily single-lead electrocardiogram (ECG) strips, defining AF burden as the proportion of AF days among total submitted ECG days. The primary outcome was atrial arrhythmia recurrence. The AF severity scale was administered pre-ablation and at 12 months post-ablation. At follow-up, 69 patients had atrial arrhythmia recurrence and 29 remained in sinus rhythm. These patients were categorized into a recurrence (n = 69) and a no-recurrence group (n = 29). Both groups had similar baseline characteristics, but recurrence patients were older (P = 0.005), had a higher prevalence of hyperlipidaemia (P = 0.007), and had a larger left atrial (LA) volume (P = 0.01). There was a reduction in AF burden in the recurrence group when compared with their pre-ablation burden (65 vs. 15%, P < 0.0001). Utah Stage 4 fibrosis and diabetes predicted less improvement in AF burden. The symptom severity score at 12 months post-ablation was significantly reduced compared with the pre-ablation score in the recurrence group, and there was a significant correlation between the reduction in symptom severity score and the reduction in AF burden (R = 0.39, P = 0.001). CONCLUSION: Catheter ablation reduces AF burden, irrespective of arrhythmia recurrence post-procedure. There is a strong correlation between AF burden reduction and symptom improvement post-ablation. Notably, elevated LA fibrosis impedes AF burden decrease following catheter ablation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Recidiva , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Ablação por Cateter/métodos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Resultado do Tratamento , Eletrocardiografia , Índice de Gravidade de Doença , Fatores de Tempo , Fatores de Risco
3.
J Electrocardiol ; 84: 15-16, 2024 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-38457909

RESUMO

An 82-year-old man with ischemic cardiomyopathy, heart failure with reduced ejection fraction and Medtronic biventricular ICD presented with shortness of breath. His ECG is presented with shortness of breath. ECG shows atrial sensed, electronic ventricular pacing. At the end of each QRS complex there is another pacemaker stimulus. This represents typical case of cardiac contractility modulation therapy and not pacemaker malfunction.

5.
Heart Rhythm ; 2024 Feb 19.
Artigo em Inglês | MEDLINE | ID: mdl-38382688

RESUMO

BACKGROUND: The impact of socioeconomic status on the clinical outcomes of patients admitted to the hospital for atrial fibrillation (AF) is not well described. OBJECTIVE: The purpose of this study was to determine the association between median neighborhood household income (mNHI) and clinical outcomes among patients admitted to the hospital for AF. METHODS: We retrospectively analyzed primary AF hospitalizations from the United States National Inpatient Sample between 2016 and 2020. The analyzed sample was divided into quartiles based on the mNHI in the zip code of the patient's residence. The lowest quartile was used as the reference category. Study outcomes included inpatient procedure utilization (ablation, cardioversion, percutaneous left atrial appendage closure), length of stay, cost, mortality, and disposition. Weighted multivariable logistic and linear regression, adjusting for multiple patient and hospital-level characteristics, was performed. RESULTS: Patients in the highest mNHI quartile had lower comorbidity burden, lower in-hospital mortality (odds ratio [OR] 0.78; 95% confidence interval [CI] 0.7-0.87; P <.001), lower discharges to care facility (OR 0.86; 95% CI 0.83-0.9; P <.001), shorter length of stay (adjusted mean difference -0.26; 95% CI -0.30 to -0.22; P <.001), higher procedure utilization, and higher health care costs ($12,124 vs $10,018) compared to the lowest mNHI quartile patients. CONCLUSION: We identified significantly higher in-hospital mortality and lower procedural/resource utilization in patients living in lower-income neighborhoods compared to higher-income neighborhoods. Further research is needed to better understand the drivers of these disparities and the strategies to improve health care disparities between socioeconomic groups.

6.
Circulation ; 149(5): 379-390, 2024 01 30.
Artigo em Inglês | MEDLINE | ID: mdl-37950738

RESUMO

BACKGROUND: Left bundle branch area pacing (LBBAP) may be associated with greater improvement in left ventricular ejection fraction and reduction in death or heart failure hospitalization compared with biventricular pacing (BVP) in patients requiring cardiac resynchronization therapy. We sought to compare the occurrence of sustained ventricular tachycardia (VT) or ventricular fibrillation (VF) and new-onset atrial fibrillation (AF) in patients undergoing BVP and LBBAP. METHODS: The I-CLAS study (International Collaborative LBBAP Study) included patients with left ventricular ejection fraction ≤35% who underwent BVP or LBBAP for cardiac resynchronization therapy between January 2018 and June 2022 at 15 centers. We performed propensity score-matched analysis of LBBAP and BVP in a 1:1 ratio. We assessed the incidence of VT/VF and new-onset AF among patients with no history of AF. Time to sustained VT/VF and time to new-onset AF was analyzed using the Cox proportional hazards survival model. RESULTS: Among 1778 patients undergoing cardiac resynchronization therapy (BVP, 981; LBBAP, 797), there were 1414 propensity score-matched patients (propensity score-matched BVP, 707; propensity score-matched LBBAP, 707). The occurrence of VT/VF was significantly lower with LBBAP compared with BVP (4.2% versus 9.3%; hazard ratio, 0.46 [95% CI, 0.29-0.74]; P<0.001). The incidence of VT storm (>3 episodes in 24 hours) was also significantly lower with LBBAP compared with BVP (0.8% versus 2.5%; P=0.013). Among 299 patients with cardiac resynchronization therapy pacemakers (BVP, 111; LBBAP, 188), VT/VF occurred in 8 patients in the BVP group versus none in the LBBAP group (7.2% versus 0%; P<0.001). In 1194 patients with no history of VT/VF or antiarrhythmic therapy (BVP, 591; LBBAP, 603), the occurrence of VT/VF was significantly lower with LBBAP than with BVP (3.2% versus 7.3%; hazard ratio, 0.46 [95% CI, 0.26-0.81]; P=0.007). Among patients with no history of AF (n=890), the occurrence of new-onset AF >30 s was significantly lower with LBBAP than with BVP (2.8% versus 6.6%; hazard ratio, 0.34 [95% CI, 0.16-0.73]; P=0.008). The incidence of AF lasting >24 hours was also significantly lower with LBBAP than with BVP (0.7% versus 2.9%; P=0.015). CONCLUSIONS: LBBAP was associated with a lower incidence of sustained VT/VF and new-onset AF compared with BVP. This difference remained significant after adjustment for differences in baseline characteristics between patients with BVP and LBBAP. Physiological resynchronization by LBBAP may be associated with lower risk of arrhythmias compared with BVP.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Taquicardia Ventricular , Humanos , Terapia de Ressincronização Cardíaca/efeitos adversos , Volume Sistólico , Função Ventricular Esquerda , Resultado do Tratamento , Taquicardia Ventricular/epidemiologia , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/terapia , Fibrilação Ventricular/epidemiologia , Fibrilação Ventricular/etiologia , Fibrilação Ventricular/terapia , Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/terapia , Eletrocardiografia
7.
JACC Clin Electrophysiol ; 10(1): 96-105, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37737782

RESUMO

BACKGROUND: Cardiac resynchronization therapy (CRT) using biventricular pacing (BVP) has been associated with greater clinical improvement in women than men. Recently, left bundle branch area pacing (LBBAP) has been shown to be an alternative form of CRT. OBJECTIVES: The purpose of this study was to investigate sex-specific outcomes for death and heart failure events in a large, international, multicenter, cohort of patients undergoing CRT with BVP or LBBAP. METHODS: In this international study of 1,778 patients (575 female and 1203 male), sex-specific survival analysis was performed to compare the effect of LBBAP-CRT relative to BVP-CRT on the combined endpoint of death or heart failure hospitalization (HFH), and secondary endpoints of HFH only, and death alone. RESULTS: Female patients were more likely to have nonischemic cardiomyopathy and left bundle branch block (LBBB) and less likely to have hypertension, diabetes, or coronary artery disease than were male patients. Overall, female patients had a better result with LBBAP compared with BVP than did male patients, with a significant 36% reduction in death or HFH (HR: 0.64; 95% CI: 0.43 to 0.97; P = 0.03) and a significant 60% reduction in HFH alone (HR: 0.4; 95% CI: 0.24 to 0.69, P < 0.01). Women had a greater reduction in death or HFH among those with nonischemic cardiomyopathy (HR: 0.45 95% CI: 0.26 to 0.79; P < 0.01) and LBBB (HR: 0.49; 95% CI: 0.27 to 0.87; P < 0.01). Sex-specific echocardiographic outcomes were better in women than in men. CONCLUSIONS: Women obtained significantly greater reductions in the combined endpoint of death or HFH (primarily driven by reduction in HFH) with LBBAP compared with BVP among patients requiring CRT than did men.


Assuntos
Terapia de Ressincronização Cardíaca , Cardiomiopatias , Insuficiência Cardíaca , Humanos , Masculino , Feminino , Terapia de Ressincronização Cardíaca/métodos , Resultado do Tratamento , Bloqueio de Ramo , Cardiomiopatias/terapia
9.
JACC Clin Electrophysiol ; 9(10): 2085-2095, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37737774

RESUMO

BACKGROUND: Atrial fibrillation (AF) recurrence during the blanking period is under investigated. With the rise of smartphone-based electrocardiogram (ECG) monitoring, there's potential for better prediction and understanding of AF recurrence trends. OBJECTIVES: In this study the authors hypothesize that AF burden derived from a single-lead Smartphone ECG during the blanking period predicts recurrence of atrial arrhythmias after ablation. METHODS: 630 patients with persistent AF undergoing ablation were included from the DECAAF II (Effect of MRI-Guided Fibrosis Ablation vs Conventional Catheter Ablation on Atrial Arrhythmia Recurrence in Patients With Persistent Atrial Fibrillation) trial. Patients recorded daily ECG strips using a smartphone device. AF burden was defined as the ratio of ECG strips with AF to the total number of strips submitted. The primary outcome was the recurrence of atrial arrhythmia. RESULTS: Recurrence occurred in 301 patients during the 18-month follow-up period. In patients who developed recurrent arrhythmia after 90 days of follow-up, AF burden during the blanking period was significantly higher when compared with patients who remained in sinus rhythm (31.3% vs 7.5%; P < 0.001). AF burden during the blanking period was an independent predictor of arrhythmia recurrence (HR: 1.41; 95% CI: 1.36-1.47; P < 0.001). Through grid searching, an AF burden of 18% best discriminates between recurrence and no-recurrence groups, yielding a C-index of 0.748. After a follow-up period of 18 months, recurrence occurred in 33.7% of patients (147 of 436) with an AF burden <18% and in 79.4% of patients (154 of 194) with an AF burden >18% (HR: 4.57; 95% CI: 3.63-5.75; P < 0.001). CONCLUSIONS: A high AF burden derived from a smartphone ECG during the blanking period is a strong predictor of atrial arrhythmia recurrences after ablation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Fibrilação Atrial/cirurgia , Resultado do Tratamento , Smartphone , Eletrocardiografia , Ablação por Cateter/efeitos adversos
12.
J Cardiovasc Electrophysiol ; 34(8): 1718-1729, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37343033

RESUMO

INTRODUCTION: Conduction system pacing (CSP) is observed to produce greater improvements in echocardiographic and hemodynamic parameters as compared to conventional biventricular pacing (BiVP). However, whether these surrogate endpoints directly translate to improvements in hard clinical outcomes such as death and heart failure hospitalization (HFH) with CSP remains uncertain as studies reporting these outcomes are scarce. The aim of this meta-analysis was to analyze the existing data to compare the clinical outcomes of CSP versus BiVP. METHODS: A systematic search of the Embase and PubMed database was performed for studies comparing CSP and BiVP for patients indicated to receive a CRT device. The coprimary endpoints were all-cause mortality and HFH. Other secondary outcomes included change in left ventricular ejection fraction (LVEF), change in NYHA class, and increase in NYHA class ≥1. A random-effects model was chosen a priori to analyze the composite effects given the anticipated heterogeneity of included trials. RESULTS: Twenty-one studies (4 randomized and 17 observational) were identified reporting either primary outcome and were included in the meta-analysis. In total 1960 patients were assigned to CSP and 2367 to BiVP. Median follow-up time was 10.1 months (ranging 2-33 months). CSP was associated with a significant reduction in all-cause mortality (odds ratio [OR] 0.68, 95% confidence interval [CI]: 0.56-0.83) and HFH (OR 0.52, 95% CI: 0.44-0.63). Mean improvement in LVEF was also greater with CSP (mean difference 4.26, 95% CI: 3.19-5.33). Reduction in NYHA class was significantly greater with CSP (mean difference -0.36, 95% CI: -0.49 to -0.22) and the number of patients with an increase in NYHA class ≥1 was significantly greater with CSP (OR 2.02, 95% CI: 1.70-2.40). CONCLUSIONS: CSP was associated with a significant reduction in all-cause mortality and HFH when compared to conventional BiVP for CRT. Further large-scale randomized trials are needed to verify these observations.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Humanos , Terapia de Ressincronização Cardíaca/efeitos adversos , Volume Sistólico , Função Ventricular Esquerda , Resultado do Tratamento , Doença do Sistema de Condução Cardíaco/terapia , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia
13.
J Am Coll Cardiol ; 82(3): 228-241, 2023 07 18.
Artigo em Inglês | MEDLINE | ID: mdl-37220862

RESUMO

BACKGROUND: Cardiac resynchronization therapy (CRT) with biventricular pacing (BVP) is a well established therapy in patients with reduced left ventricular ejection fraction (LVEF), heart failure, and wide QRS or expected frequent ventricular pacing. Left bundle branch area pacing (LBBAP) has recently been shown to be a safe alternative to BVP. OBJECTIVES: The aim of this study was to compare the clinical outcomes between BVP and LBBAP among patients undergoing CRT. METHODS: This observational study included patients with LVEF ≤35% who underwent BVP or LBBAP for the first time for Class I or II indications for CRT from January 2018 to June 2022 at 15 international centers. The primary outcome was the composite endpoint of time to death or heart failure hospitalization (HFH). Secondary outcomes included endpoints of death, HFH, and echocardiographic changes. RESULTS: A total of 1,778 patients met inclusion criteria: 981 BVP, 797 LBBAP. The mean age was 69 ± 12 years, 32% were female, 48% had coronary artery disease, and mean LVEF was 27% ± 6%. Paced QRS duration in LBBAP was significantly narrower than baseline (128 ± 19 ms vs 161 ± 28 ms; P < 0.001) and significantly narrower compared to BVP (144 ± 23 ms; P < 0.001). Following CRT, LVEF improved from 27% ± 6% to 41% ± 13% (P < 0.001) with LBBAP compared with an increase from 27% ± 7% to 37% ± 12% (P < 0.001) with BVP, with significantly greater change from baseline with LBBAP (13% ± 12% vs 10% ± 12%; P < 0.001). On multivariable regression analysis, the primary outcome was significantly reduced with LBBAP compared with BVP (20.8% vs 28%; HR: 1.495; 95% CI: 1.213-1.842; P < 0.001). CONCLUSIONS: LBBAP improved clinical outcomes compared with BVP in patients with CRT indications and may be a reasonable alternative to BVP.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Masculino , Volume Sistólico , Eletrocardiografia , Função Ventricular Esquerda , Resultado do Tratamento , Insuficiência Cardíaca/terapia
15.
Am J Physiol Heart Circ Physiol ; 324(3): H259-H278, 2023 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-36563014

RESUMO

The sinoatrial node (SAN) is the primary pacemaker of the heart. Normal SAN function is crucial in maintaining proper cardiac rhythm and contraction. Sinus node dysfunction (SND) is due to abnormalities within the SAN, which can affect the heartbeat frequency, regularity, and the propagation of electrical pulses through the cardiac conduction system. As a result, SND often increases the risk of cardiac arrhythmias. SND is most commonly seen as a disease of the elderly given the role of degenerative fibrosis as well as other age-dependent changes in its pathogenesis. Despite the prevalence of SND, current treatment is limited to pacemaker implantation, which is associated with substantial medical costs and complications. Emerging evidence has identified various genetic abnormalities that can cause SND, shedding light on the molecular underpinnings of SND. Identification of these molecular mechanisms and pathways implicated in the pathogenesis of SND is hoped to identify novel therapeutic targets for the development of more effective therapies for this disease. In this review article, we examine the anatomy of the SAN and the pathophysiology and epidemiology of SND. We then discuss in detail the most common genetic mutations correlated with SND and provide our perspectives on future research and therapeutic opportunities in this field.


Assuntos
Síndrome do Nó Sinusal , Nó Sinoatrial , Humanos , Idoso , Síndrome do Nó Sinusal/genética , Nó Sinoatrial/metabolismo , Sistema de Condução Cardíaco , Arritmias Cardíacas/metabolismo , Frequência Cardíaca/fisiologia
16.
J Interv Card Electrophysiol ; 66(6): 1499-1518, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35879516

RESUMO

Catheter ablation of ventricular arrhythmias (VAs) has evolved significantly over the past decade and is currently a well-established therapeutic option. Technological advances and improved understanding of VA mechanisms have led to tremendous innovations in VA ablation. The purpose of this review article is to provide an overview of current innovations in VA ablation. Mapping techniques, such as ultra-high density mapping, isochronal late activation mapping, and ripple mapping, have provided improved arrhythmogenic substrate delineation and potential procedural success while limiting duration of ablation procedure and potential hemodynamic compromise. Besides, more advanced mapping and ablation techniques such as epicardial and intramyocardial ablation approaches have allowed operators to more precisely target arrhythmogenic substrate. Moreover, advances in alternate energy sources, such as electroporation, as well as stereotactic radiation therapy have been proposed to be effective and safe. New catheters, such as the lattice and the saline-enhanced radiofrequency catheters, have been designed to provide deeper and more durable tissue ablation lesions compared to conventional catheters. Contact force optimization and baseline impedance modulation are important tools to optimize VT radiofrequency ablation and improve procedural success. Furthermore, advances in cardiac imaging, specifically cardiac MRI, have great potential in identifying arrhythmogenic substrate and evaluating ablation success. Overall, VA ablation has undergone significant advances over the past years. Innovations in VA mapping techniques, alternate energy source, new catheters, and utilization of cardiac imaging have great potential to improve overall procedural safety, hemodynamic stability, and procedural success.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Humanos , Taquicardia Ventricular/terapia , Arritmias Cardíacas/cirurgia , Ablação por Cateter/métodos , Resultado do Tratamento
17.
J Interv Card Electrophysiol ; 66(3): 737-756, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35411440

RESUMO

BACKGROUND: Catheter-based ablation to perform pulmonary vein isolation (PVI) has established itself as a mainstay in the rhythm control strategy of atrial fibrillation. This review article aims to provide an overview of recent advances in atrial fibrillation ablation technology. METHODS: We reviewed the available literature and clinical trials of innovations in atrial fibrillation ablation technologies including ablation catheter designs, alternative energy sources, esophageal protection methods, electroanatomical mapping, and novel ablation targets. RESULTS: Innovative radiofrequency (RF) catheter designs maximize energy delivery while avoiding overheating associated with conventional catheters. Single-shot balloon catheters in the form of cryoballoons, radiofrequency, and laser balloons have proven effective at producing pulmonary vein isolation and improving procedural efficiency and reproducibility. Pulsed field ablation (PFA) is a highly anticipated novel nonthermal energy source under development, which demonstrates selective ablation of the myocardium, producing durable lesions while also minimizing collateral damage. Innovative devices for esophageal protection including esophageal deviation and cooling devices have been developed to reduce esophageal complications. Improved electroanatomical mapping systems are being developed to help identify additional non-pulmonary triggers, which may benefit from ablation, especially with persistent atrial fibrillation. Lastly, the vein of Marshall alcohol ablation has been recently studied as an adjunct therapy for improving outcomes with catheter ablation for persistent atrial fibrillation. CONCLUSIONS: Numerous advances have been made in the field of atrial fibrillation ablation in the past decade. While further long-term data is still needed for these novel technologies, they show potential to improve procedural efficacy and safety.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/cirurgia , Reprodutibilidade dos Testes , Resultado do Tratamento , Catéteres , Veias Pulmonares/cirurgia , Ablação por Cateter/métodos
18.
J Interv Card Electrophysiol ; 66(3): 585-595, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36089635

RESUMO

BACKGROUND: There is limited data comparing radiofrequency (RF) and cryoballoon (CB) ablation for persistent atrial fibrillation (AF), which tends to have higher recurrence rates following ablation compared to paroxysmal AF. METHODS: A systematic search of the Embase, PubMed, and Cochrane database was performed for studies comparing RF vs CB ablation for persistent AF. An inverse-variance random-effects model was used to calculate the composite effects. RESULTS: One randomized and 9 observational studies were identified, with 1650 patients receiving CB and 1706 patients receiving RF ablation. Mean follow-up time ranged from 12 to 48 months. Freedom from recurrent atrial tachyarrhythmia was similar with the two modalities (HR 0.93, 95% CI 0.80 to 1.08, I2 0%). Total complications were similar in both groups (RR 1.05, 95% CI 0.73 to 1.53, I2 0%) although rates of phrenic nerve palsy (PNP) were greater with CB (RR 4.13, 95% CI 1.49 to 11.46, I2 0%). Shorter procedure times were observed with CB (mean reduction 43.77 min, 95% CI 66.45 to 21.09 min, I2 96%) with no difference in fluoroscopy time (mean difference 0.82 min, 95% CI - 11.92 to 13.55 min, I2 100%). CONCLUSIONS: In persistent AF patients, CB ablation has similar efficacy and overall safety as compared to RF ablation. While CB is associated with significantly shorter procedure times, the improved procedural efficiency with CB is offset by increased rates of PNP and the potential need for touch-up RF ablation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Ablação por Radiofrequência , Humanos , Fibrilação Atrial/cirurgia , Resultado do Tratamento , Ablação por Cateter/métodos , Criocirurgia/métodos , Veias Pulmonares/cirurgia , Recidiva
19.
Heart Rhythm ; 19(8): 1289-1296, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35490710

RESUMO

BACKGROUND: Leadless pacemakers have emerged as a viable alternative for traditional transvenous pacemakers to reduce the risk of device-related complications. OBJECTIVE: The purpose of this study was to examine the real-world clinical outcomes and complications associated with the implantation of leadless pacemaker devices. METHODS: Using the National Readmission Database (NRD), we examined patient demographics, and in-hospital and 30-day procedural outcomes after leadless pacemaker implantation from 2016-2018. Our cohort comprised adults (≥18 years) with an ICD-10 procedural code for leadless pacemaker implantation. RESULTS: Our cohort included a total of 7821 patients who underwent leadless pacemaker implantation. Overall immediate procedure-related complications, as defined broadly in this study, occurred in 7.5% of patients. Pericardial effusion without the need for pericardiocentesis occurred in 1.9% of patients, with pericardiocentesis performed in 1.0%. Vascular complications occurred in 2.3% of patients; 0.33% required repair, and device dislodgment occurred in 0.51%. The most significant predictor for procedural complications was end-stage renal disease (odds ratio [OR] 1.65; 95% confidence interval [CI] 1.17-2.32; P = .004), congestive heart failure (OR 1.28; 95% CI 1.01-1.62; P = .04), and coagulopathy (OR 1.77; 95% CI 1.34-2.34; P <.001). All-cause readmission occurred in 17.9% of patients within 30 days from device implant, with 1.36% of readmissions being procedure related. At 30 days postimplant and after discharge, 0.25% of patients needed a new pacemaker, and 0.18% had pericardial complications. CONCLUSION: In our large real-life cohort, we found the rate of serious complications after leadless pacemaker implantation to be relatively low and comparable to prior studies in a high-risk population with multiple comorbid conditions.


Assuntos
Falência Renal Crônica , Marca-Passo Artificial , Derrame Pericárdico , Adulto , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/terapia , Desenho de Equipamento , Humanos , Marca-Passo Artificial/efeitos adversos , Derrame Pericárdico/etiologia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...