Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 59
Filtrar
1.
Inhal Toxicol ; 32(1): 24-38, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-32028803

RESUMO

Objective: In this study, we compared in vitro and in vivo bioactivity of nitrogen-doped multi-walled carbon nanotubes (NDMWCNT) to MWCNT to test the hypothesis that nitrogen doping would alter bioactivity.Materials and Methods: High-resolution transmission electron microscopy (TEM) confirmed the multilayer structure of MWCNT with an average layer distance of 0.36 nm, which was not altered by nitrogen doping: the nanomaterials had similar widths and lengths. In vitro studies with THP-1 cells and alveolar macrophages from C57BL/6 mice demonstrated that NDMWCNT were less cytotoxic and stimulated less IL-1ß release compared to MWCNT. For in vivo studies, male C57BL/6J mice received a single dose of dispersion medium (DM), 2.5, 10 or 40 µg/mouse of NDMWCNT, or 40 µg/mouse of MWCNT by oropharyngeal aspiration. Animals were euthanized between 1 and 7 days post-exposure for whole lung lavage (WLL) studies.Results and Discussion: NDMWCNT caused time- and dose-dependent pulmonary inflammation. However, it was less than that caused by MWCNT. Activation of the NLRP3 inflammasome was assessed in particle-exposed mice by determining cytokine production in WLL fluid at 1 day post-exposure. Compared to DM-exposed mice, IL-1ß and IL-18 were significantly increased in MWCNT- and NDMWCNT-exposed mice, but the increase caused by NDMWCNT was less than MWCNT. At 56 days post-exposure, histopathology determined lung fibrosis in MWCNT-exposed mice was greater than NDMWCNT-exposed mice.Conclusions: These data indicate nitrogen doping of MWCNT decreases their bioactivity, as reflected with lower in vitro and in vivo toxicity inflammation and lung disease. The lower activation of the NLRP3 inflammasome may be responsible. Abbreviations: NDMWCNT: nitrogen-doped multi-walled carbon nanotubes; MWCNT: multi-walled carbon nanotubes; TEM: transmission electron microscopy; HRTEM: high resolution transmission electron microscopy; IL-1ß: interleukin-1ß; DM: dispersion medium; WLL: whole lung lavage; IL-18: interleukin-18; GSD: geometric standard deviation; XPS: X-ray photoelectron spectroscopy; SEM: standard error of the mean; PMA: phorbol 12-myristate 13-acetate; LPS: lipopolysacharride; LDH: lactate dehydrogenase; AM: alveolar macrophage; PMN: polymorphonuclear leukocyte.


Assuntos
Exposição por Inalação/efeitos adversos , Pulmão/efeitos dos fármacos , Macrófagos Alveolares/efeitos dos fármacos , Nanotubos de Carbono/toxicidade , Nitrogênio/toxicidade , Pneumonia/induzido quimicamente , Animais , Líquido da Lavagem Broncoalveolar/química , Citocinas/análise , Relação Dose-Resposta a Droga , Humanos , Inflamassomos/imunologia , Inflamassomos/metabolismo , Pulmão/imunologia , Pulmão/patologia , Macrófagos Alveolares/imunologia , Macrófagos Alveolares/patologia , Masculino , Camundongos Endogâmicos C57BL , Nanotubos de Carbono/química , Nitrogênio/química , Tamanho da Partícula , Pneumonia/imunologia , Pneumonia/patologia , Propriedades de Superfície , Células THP-1 , Fatores de Tempo
2.
Nanotoxicology ; 11(8): 1040-1058, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29094619

RESUMO

Boron nitride nanotubes (BNNTs) are an emerging engineered nanomaterial attracting significant attention due to superior electrical, chemical and thermal properties. Currently, the toxicity profile of this material is largely unknown. Commercial grade BNNTs are composed of a mixture (BNNT-M) of ∼50-60% BNNTs, and ∼40-50% impurities of boron and hexagonal boron nitride. We performed acute in vitro and in vivo studies with commercial grade BNNT-M, dispersed by sonication in vehicle, in comparison to the extensively studied multiwalled carbon nanotube-7 (MWCNT-7). THP-1 wild-type and NLRP3-deficient human monocytic cells were exposed to 0-100 µg/ml and C57BL/6 J male mice were treated with 40 µg of BNNT-M for in vitro and in vivo studies, respectively. In vitro, BNNT-M induced a dose-dependent increase in cytotoxicity and oxidative stress. This was confirmed in vivo following acute exposure increase in bronchoalveolar lavage levels of lactate dehydrogenase, pulmonary polymorphonuclear cell influx, loss in mitochondrial membrane potential and augmented levels of 4-hydroxynonenal. Uptake of this material caused lysosomal destabilization, pyroptosis and inflammasome activation, corroborated by an increase in cathepsin B, caspase 1, increased protein levels of IL-1ß and IL-18 both in vitro and in vivo. Attenuation of these effects in NLRP3-deficient THP-1 cells confirmed NLRP3-dependent inflammasome activation by BNNT-M. BNNT-M induced a similar profile of inflammatory pulmonary protein production when compared to MWCNT-7. Functionally, pretreatment with BNNT-M caused suppression in bacterial uptake by THP-1 cells, an effect that was mirrored in challenged alveolar macrophages collected from exposed mice and attenuated with NLRP3 deficiency. Analysis of cytokines secreted by LPS-challenged alveolar macrophages collected after in vivo exposure to dispersions of BNNT-M showed a differential macrophage response. The observed results demonstrated acute inflammation and toxicity in vitro and in vivo following exposure to sonicated BNNT-M was in part due to NLRP3 inflammasome activation.


Assuntos
Compostos de Boro/toxicidade , Pulmão/efeitos dos fármacos , Nanotubos/toxicidade , Estresse Oxidativo/efeitos dos fármacos , Animais , Líquido da Lavagem Broncoalveolar/citologia , Líquido da Lavagem Broncoalveolar/imunologia , Linhagem Celular , Sobrevivência Celular/efeitos dos fármacos , Relação Dose-Resposta a Droga , Humanos , Inflamação , Pulmão/metabolismo , Pulmão/patologia , Macrófagos Alveolares/efeitos dos fármacos , Macrófagos Alveolares/imunologia , Masculino , Potencial da Membrana Mitocondrial/efeitos dos fármacos , Camundongos , Camundongos Endogâmicos C57BL , Proteína 3 que Contém Domínio de Pirina da Família NLR/genética , Proteína 3 que Contém Domínio de Pirina da Família NLR/metabolismo , Tamanho da Partícula , Piroptose/efeitos dos fármacos
3.
Inhal Toxicol ; 29(7): 322-339, 2017 06.
Artigo em Inglês | MEDLINE | ID: mdl-28967277

RESUMO

The effects of acute pulmonary coexposures to silica and diesel particulate matter (DPM), which may occur in various mining operations, were investigated in vivo. Rats were exposed by intratracheal instillation (IT) to silica (50 or 233 µg), DPM (7.89 or 50 µg) or silica and DPM combined in phosphate-buffered saline (PBS) or to PBS alone (control). At one day, one week, one month, two months and three months postexposure bronchoalveolar lavage and histopathology were performed to assess lung injury, inflammation and immune response. While higher doses of silica caused inflammation and injury at all time points, DPM exposure alone did not. DPM (50 µg) combined with silica (233 µg) increased inflammation at one week and one-month postexposure and caused an increase in the incidence of fibrosis at one month compared with exposure to silica alone. To assess susceptibility to lung infection following coexposure, rats were exposed by IT to 233 µg silica, 50 µg DPM, a combination of the two or PBS control one week before intratracheal inoculation with 5 × 105 Listeria monocytogenes. At 1, 3, 5, 7 and 14 days following infection, pulmonary immune response and bacterial clearance from the lung were evaluated. Coexposure to DPM and silica did not alter bacterial clearance from the lung compared to control. Although DPM and silica coexposure did not alter pulmonary susceptibility to infection in this model, the study showed that noninflammatory doses of DPM had the capacity to increase silica-induced lung injury, inflammation and onset/incidence of fibrosis.


Assuntos
Poluentes Ocupacionais do Ar/toxicidade , Pulmão/efeitos dos fármacos , Material Particulado/toxicidade , Quartzo/toxicidade , Emissões de Veículos/toxicidade , Lesão Pulmonar Aguda/induzido quimicamente , Animais , Líquido da Lavagem Broncoalveolar/citologia , Líquido da Lavagem Broncoalveolar/imunologia , Contagem de Células , Citocinas/imunologia , L-Lactato Desidrogenase/metabolismo , Listeria monocytogenes/patogenicidade , Listeriose , Pulmão/imunologia , Pulmão/microbiologia , Pulmão/patologia , Masculino , Ratos Sprague-Dawley , Testes de Toxicidade Aguda
4.
Toxicol Rep ; 4: 123-133, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28959633

RESUMO

Resistance spot welding is a common process to join metals in the automotive industry. Adhesives are often used as sealers to seams of metals that are joined. Anti-spatter compounds sometimes are sprayed onto metals to be welded to improve the weldability. Spot welding produces complex aerosols composed of metal and volatile compounds (VOCs) which can cause lung disease in workers. Male Sprague-Dawley rats (n = 12/treatment group) were exposed by inhalation to 25 mg/m3 of aerosol for 4 h/day × 8 days during spot welding of galvanized zinc (Zn)-coated steel in the presence or absence of a glue or anti-spatter spray. Controls were exposed to filtered air. Particle size distribution and chemical composition of the generated aerosol were determined. At 1 and 7 days after exposure, bronchoalveolar lavage (BAL) was performed to assess lung toxicity. The generated particles mostly were in the submicron size range with a significant number of nanometer-sized particles formed. The primary metals present in the fumes were Fe (72.5%) and Zn (26.3%). The addition of the anti-spatter spray and glue did affect particle size distribution when spot welding galvanized steel, whereas they had no effect on metal composition. Multiple VOCs (e.g., methyl methacrylate, acetaldehyde, ethanol, acetone, benzene, xylene) were identified when spot welding using either the glue or the anti-spatter spray that were not present when welding alone. Markers of lung injury (BAL lactate dehydrogenase) and inflammation (total BAL cells/neutrophils and cytokines/chemokines) were significantly elevated compared to controls 1 day after exposure to the spot welding fumes. The elevated pulmonary response was transient as lung toxicity mostly returned to control values by 7 days. The VOCs or the concentrations that they were generated during the animal exposures had no measurable effect on the pulmonary responses. Inhalation of galvanized spot welding fumes caused acute lung toxicity most likely due to the short-term exposure of particles that contain Zn.

5.
J Occup Environ Hyg ; 14(7): 540-550, 2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-28440728

RESUMO

Printing devices are known to emit chemicals into the indoor atmosphere. Understanding factors that influence release of chemical contaminants from printers is necessary to develop effective exposure assessment and control strategies. In this study, a desktop fused deposition modeling (FDM) 3-dimensional (3-D) printer using acrylonitrile butadiene styrene (ABS) or polylactic acid (PLA) filaments and two monochrome laser printers were evaluated in a 0.5 m3 chamber. During printing, chamber air was monitored for vapors using a real-time photoionization detector (results expressed as isobutylene equivalents) to measure total volatile organic compound (TVOC) concentrations, evacuated canisters to identify specific VOCs by off-line gas chromatography-mass spectrometry (GC-MS) analysis, and liquid bubblers to identify carbonyl compounds by GC-MS. Airborne particles were collected on filters for off-line analysis using scanning electron microscopy with an energy dispersive x-ray detector to identify elemental constituents. For 3-D printing, TVOC emission rates were influenced by a printer malfunction, filament type, and to a lesser extent, by filament color; however, rates were not influenced by the number of printer nozzles used or the manufacturer's provided cover. TVOC emission rates were significantly lower for the 3-D printer (49-3552 µg h-1) compared to the laser printers (5782-7735 µg h-1). A total of 14 VOCs were identified during 3-D printing that were not present during laser printing. 3-D printed objects continued to off-gas styrene, indicating potential for continued exposure after the print job is completed. Carbonyl reaction products were likely formed from emissions of the 3-D printer, including 4-oxopentanal. Ultrafine particles generated by the 3-D printer using ABS and a laser printer contained chromium. Consideration of the factors that influenced the release of chemical contaminants (including known and suspected asthmagens such as styrene and 4-oxopentanal) from a FDM 3-D printer should be made when designing exposure assessment and control strategies.


Assuntos
Poluição do Ar em Ambientes Fechados/análise , Material Particulado/análise , Impressão Tridimensional , Compostos Orgânicos Voláteis/análise , Acrilonitrila/análise , Aldeídos/análise , Butadienos , Cromo/análise , Monitoramento Ambiental/métodos , Cetonas/análise , Poliésteres , Estireno/análise
6.
Inhal Toxicol ; 29(2): 53-64, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-28317464

RESUMO

An understanding of the mechanisms underlying diseases is critical for their prevention. Excessive exposure to crystalline silica is a risk factor for silicosis, a potentially fatal pulmonary disease. Male Fischer 344 rats were exposed by inhalation to crystalline silica (15 mg/m3, six hours/day, five days) and pulmonary response was determined at 44 weeks following termination of silica exposure. Additionally, global gene expression profiling in lungs and BAL cells and bioinformatic analysis of the gene expression data were done to understand the molecular mechanisms underlying the progression of pulmonary response to silica. A significant increase in lactate dehydrogenase activity and albumin content in BAL fluid (BALF) suggested silica-induced pulmonary toxicity in the rats. A significant increase in the number of alveolar macrophages and infiltrating neutrophils in the lungs and elevation in monocyte chemoattractant protein-1 (MCP-1) in BALF suggested the induction of pulmonary inflammation in the silica exposed rats. Histological changes in the lungs included granuloma formation, type II pneumocyte hyperplasia, thickening of alveolar septa and positive response to Masson's trichrome stain. Microarray analysis of global gene expression detected 94 and 225 significantly differentially expressed genes in the lungs and BAL cells, respectively. Bioinformatic analysis of the gene expression data identified significant enrichment of several disease and biological function categories and canonical pathways related to pulmonary toxicity, especially inflammation. Taken together, these data suggested the involvement of chronic inflammation as a mechanism underlying the progression of pulmonary response to exposure of rats to crystalline silica at 44 weeks following termination of exposure.


Assuntos
Pulmão/efeitos dos fármacos , Dióxido de Silício/toxicidade , Animais , Líquido da Lavagem Broncoalveolar/química , Líquido da Lavagem Broncoalveolar/citologia , Líquido da Lavagem Broncoalveolar/imunologia , Contagem de Células , Perfilação da Expressão Gênica , Pulmão/imunologia , Pulmão/metabolismo , Pulmão/patologia , Macrófagos/imunologia , Masculino , Ratos , Ratos Endogâmicos F344
7.
Inhal Toxicol ; 29(2): 75-81, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-28330428

RESUMO

Moisture-damaged indoor environments are thought to increase the toxicity of indoor air particulate matter (PM), indicating that a toxicological assay could be used as a method for recognizing buildings with indoor air problems. We aimed to test if our approach of analyzing the toxicity of actively collected indoor air PM in vitro differentiates moisture-damaged from non-damaged school buildings. We collected active air samples with NIOSH Bioaerosol Cyclone Samplers from moisture-damaged (index) and non-damaged (reference) school buildings (4 + 4). The teachers and pupils of the schools were administered a symptom questionnaire. Five samples of two size fractions [Stage 1 (>1.9 µm) and Stage 2 (1-1.9 µm)] were collected from each school. Mouse RAW264.7 macrophages were exposed to the collected PM for 24 h and subsequently analyzed for changes in cell metabolic activity, production of nitric oxide (NO), tumor necrosis factor (TNF)-α and interleukin (IL)-6. The teachers working in the moisture-damaged schools reported respiratory symptoms such as cough (p = 0.01) and shortness of breath (p = 0.01) more often than teachers from reference schools. Toxicity of the PM sample as such did not differentiate index from reference building,s but the toxicity adjusted for the amount of the particles tended to be higher in moisture-damaged schools. Further development of the method will require identification of other confounding factors in addition to the necessity to adjust for differences in particle counts between samples.


Assuntos
Poluição do Ar em Ambientes Fechados/efeitos adversos , Poeira , Umidade , Material Particulado/efeitos adversos , Instituições Acadêmicas , Poluição do Ar em Ambientes Fechados/análise , Animais , Monitoramento Ambiental , Feminino , Nível de Saúde , Humanos , Interleucina-6/metabolismo , Masculino , Camundongos , Óxido Nítrico/metabolismo , Material Particulado/análise , Células RAW 264.7 , Professores Escolares , Estudantes , Fator de Necrose Tumoral alfa/metabolismo
8.
Inhal Toxicol ; 28(11): 500-7, 2016 09.
Artigo em Inglês | MEDLINE | ID: mdl-27569522

RESUMO

There is a need for toxicity tests capable of recognizing indoor environments with compromised air quality, especially in the context of moisture damage. One of the key issues is sampling, which should both provide meaningful material for analyses and fulfill requirements imposed by practitioners using toxicity tests for health risk assessment. We aimed to evaluate different existing methods of sampling indoor particulate matter (PM) to develop a suitable sampling strategy for a toxicological assay. During three sampling campaigns in moisture-damaged and non-damaged school buildings, we evaluated one passive and three active sampling methods: the Settled Dust Box (SDB), the Button Aerosol Sampler, the Harvard Impactor and the National Institute for Occupational Safety and Health (NIOSH) Bioaerosol Cyclone Sampler. Mouse RAW264.7 macrophages were exposed to particle suspensions and cell metabolic activity (CMA), production of nitric oxide (NO) and tumor necrosis factor (TNFα) were determined after 24 h of exposure. The repeatability of the toxicological analyses was very good for all tested sampler types. Variability within the schools was found to be high especially between different classrooms in the moisture-damaged school. Passively collected settled dust and PM collected actively with the NIOSH Sampler (Stage 1) caused a clear response in exposed cells. The results suggested the higher relative immunotoxicological activity of dust from the moisture-damaged school. The NIOSH Sampler is a promising candidate for the collection of size-fractionated PM to be used in toxicity testing. The applicability of such sampling strategy in grading moisture damage severity in buildings needs to be developed further in a larger cohort of buildings.


Assuntos
Poluição do Ar em Ambientes Fechados/análise , Monitoramento Ambiental/métodos , Material Particulado/análise , Poluição do Ar em Ambientes Fechados/efeitos adversos , Animais , Monitoramento Ambiental/instrumentação , Camundongos , Óxido Nítrico/metabolismo , Material Particulado/toxicidade , Células RAW 264.7 , Instituições Acadêmicas , Testes de Toxicidade/métodos , Fator de Necrose Tumoral alfa/metabolismo
9.
J Aerosol Sci ; 99: 157-162, 2016 09.
Artigo em Inglês | MEDLINE | ID: mdl-27546900

RESUMO

The early incorporation of exposure assessment can be invaluable to help design, prioritize, and interpret toxicological studies or outcomes. The sum total of the exposure assessment findings combined with preliminary toxicology results allows for exposure-informed toxicological study design and the findings can then be integrated, together with available epidemiologic data, to provide health effect relevance. With regard to engineered nanomaterial inhalation toxicology in particular, a single type of material (e.g. carbon nanotube, graphene) can have a vast array of physicochemical characteristics resulting in the potential for varying toxicities. To compound the matter, the methodologies necessary to establish a material adequate for in vivo exposure testing raises questions on the applicability of the outcomes. From insights gained from evaluating carbon nanotubes, we recommend the following integrated approach involving exposure-informed hazard assessment and hazard-informed exposure assessment especially for materials as diverse as engineered nanomaterials: 1) market-informed identification of potential hazards and potentially exposed populations, 2) initial toxicity screening to drive prioritized assessments of exposure, 3) development of exposure assessment-informed chronic and sub-chronic in vivo studies, and 4) conduct of exposure- and hazard-informed epidemiological studies.

10.
Part Fibre Toxicol ; 13(1): 42, 2016 08 15.
Artigo em Inglês | MEDLINE | ID: mdl-27527840

RESUMO

BACKGROUND: Although classified as metal oxides, cobalt monoxide (CoO) and lanthanum oxide (La2O3) nanoparticles, as representative transition and rare earth oxides, exhibit distinct material properties that may result in different hazardous potential in the lung. The current study was undertaken to compare the pulmonary effects of aerosolized whole body inhalation of these nanoparticles in mice. RESULTS: Mice were exposed to filtered air (control) and 10 or 30 mg/m(3) of each particle type for 4 days and then examined at 1 h, 1, 7 and 56 days post-exposure. The whole lung burden 1 h after the 4 day inhalation of CoO nanoparticles was 25 % of that for La2O3 nanoparticles. At 56 days post exposure, < 1 % of CoO nanoparticles remained in the lungs; however, 22-50 % of the La2O3 nanoparticles lung burden 1 h post exposure was retained at 56 days post exposure for low and high exposures. Significant accumulation of La2O3 nanoparticles in the tracheobronchial lymph nodes was noted at 56 days post exposure. When exposed to phagolysosomal simulated fluid, La nanoparticles formed urchin-shaped LaPO4 structures, suggesting that retention of this rare earth oxide nanoparticle may be due to complexation of cellular phosphates within lysosomes. CoO nanoparticles caused greater lactate dehydrogenase release in the bronchoalveolar fluid (BALF) compared to La2O3 nanoparticles at 1 day post exposure, while BAL cell differentials indicate that La2O3 nanoparticles generated more inflammatory cell infiltration at all doses and exposure points. Histopathological analysis showed acute inflammatory changes at 1 day after inhalation of either CoO or La2O3 nanoparticles. Only the 30 mg/m(3) La2O3 nanoparticles exposure caused chronic inflammatory changes and minimal fibrosis at day 56 post exposure. This is in agreement with activation of the NRLP3 inflammasome after in vitro exposure of differentiated THP-1 macrophages to La2O3 but not after CoO nanoparticles exposure. CONCLUSION: Taken together, the inhalation studies confirmed the trend of our previous sub-acute aspiration study, which reported that CoO nanoparticles induced more acute pulmonary toxicity, while La2O3 nanoparticles caused chronic inflammatory changes and minimal fibrosis.


Assuntos
Cobalto/toxicidade , Lantânio/toxicidade , Pulmão/efeitos dos fármacos , Nanopartículas Metálicas/toxicidade , Óxidos/toxicidade , Aerossóis , Animais , Líquido da Lavagem Broncoalveolar , Cobalto/farmacocinética , Citocinas/metabolismo , Exposição por Inalação , Lantânio/farmacocinética , Pulmão/metabolismo , Pulmão/patologia , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Óxidos/farmacocinética
11.
J Toxicol Environ Health A ; 79(11): 453-65, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27196745

RESUMO

Desktop three-dimensional (3D) printers are becoming commonplace in business offices, public libraries, university labs and classrooms, and even private homes; however, these settings are generally not designed for exposure control. Prior experience with a variety of office equipment devices such as laser printers that emit ultrafine particles (UFP) suggests the need to characterize 3D printer emissions to enable reliable risk assessment. The aim of this study was to examine factors that influence particulate emissions from 3D printers and characterize their physical properties to inform risk assessment. Emissions were evaluated in a 0.5-m(3) chamber and in a small room (32.7 m(3)) using real-time instrumentation to measure particle number, size distribution, mass, and surface area. Factors evaluated included filament composition and color, as well as the manufacturer-provided printer emissions control technologies while printing an object. Filament type significantly influenced emissions, with acrylonitrile butadiene styrene (ABS) emitting larger particles than polylactic acid (PLA), which may have been the result of agglomeration. Geometric mean particle sizes and total particle (TP) number and mass emissions differed significantly among colors of a given filament type. Use of a cover on the printer reduced TP emissions by a factor of 2. Lung deposition calculations indicated a threefold higher PLA particle deposition in alveoli compared to ABS. Desktop 3D printers emit high levels of UFP, which are released into indoor environments where adequate ventilation may not be present to control emissions. Emissions in nonindustrial settings need to be reduced through the use of a hierarchy of controls, beginning with device design, followed by engineering controls (ventilation) and administrative controls such as choice of filament composition and color.


Assuntos
Poluentes Atmosféricos/análise , Poluição do Ar em Ambientes Fechados/análise , Monitoramento Ambiental , Material Particulado/análise , Impressão Tridimensional , Tamanho da Partícula , Ventilação
12.
J Occup Environ Hyg ; 13(7): 501-18, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-26873639

RESUMO

Direct-reading instruments have been widely used for characterizing airborne nanoparticles in inhalation toxicology and industrial hygiene studies for exposure/risk assessments. Instruments using electrical mobility sizing followed by optical counting, e.g., scanning or sequential mobility particle spectrometers (SMPS), have been considered as the "gold standard" for characterizing nanoparticles. An SMPS has the advantage of rapid response and has been widely used, but there is little information on its performance in assessing the full spectrum of nanoparticles encountered in the workplace. In this study, an SMPS was evaluated for its effectiveness in producing "monodisperse" aerosol and its adequacy in characterizing overall particle size distribution using three test aerosols, each mimicking a unique class of real-life nanoparticles: singlets of nearly spherical titanium dioxide (TiO2), agglomerates of fiber-like multi-walled carbon nanotube (MWCNT), and aggregates that constitutes welding fume (WF). These aerosols were analyzed by SMPS, cascade impactor, and by counting and sizing of discrete particles by scanning and transmission electron microscopy. The effectiveness of the SMPS to produce classified particles (fixed voltage mode) was assessed by examination of the resulting geometric standard deviation (GSD) from the impactor measurement. Results indicated that SMPS performed reasonably well for TiO2 (GSD = 1.3), but not for MWCNT and WF as evidenced by the large GSD values of 1.8 and 1.5, respectively. For overall characterization, results from SMPS (scanning voltage mode) exhibited particle-dependent discrepancies in the size distribution and total number concentration compared to those from microscopic analysis. Further investigation showed that use of a single-stage impactor at the SMPS inlet could distort the size distribution and underestimate the concentration as shown by the SMPS, whereas the presence of vapor molecules or atom clusters in some test aerosols might cause artifacts by counting "phantom particles." Overall, the information obtained from this study will help understand the limitations of the SMPS in measuring nanoparticles so that one can adequately interpret the results for risk assessments and exposure prevention in an occupational or ambient environment.


Assuntos
Poluentes Ocupacionais do Ar/análise , Nanotubos de Carbono/análise , Tamanho da Partícula , Titânio/análise , Soldagem , Aerossóis , Microscopia Eletrônica de Varredura , Microscopia Eletrônica de Transmissão
13.
J Occup Environ Hyg ; 13(1): 1-8, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26267301

RESUMO

Nine gas metal arc welding (GMAW) processes for stainless steel were assessed for fume generation rates, fume generation rates per g of electrode consumed, and emission rates for hexavalent chromium (Cr(6+)). Elemental manganese, nickel, chromium, iron emissions per unit length of weld, and labor plus consumables costs were similarly measured. Flux-cored arc welding and shielded metal arc (SMAW) processes were also studied. The objective was to identify the best welding processes for reducing workplace exposures, and estimate costs for all processes. Using a conical chamber, fumes were collected, weighed, recovered, and analyzed by inductively coupled atomic emission spectroscopy for metals, and by ion chromatography for Cr(6+). GMAW processes used were Surface Tension Transfer, Regulated Metal Deposition, Cold Metal Transfer, short-circuit, axial spray, and pulsed spray modes. Flux-cored welding used gas shielding; SMAW used E308 rods. Costs were estimated as dollars per m length of a » in (6.3 mm) thick horizontal butt weld; equipment costs were estimated as ratios of new equipment costs to a 250 ampere capacity SMAW welding machine. Results indicate a broad range of fume emission factors for the processes studied. Fume emission rates per g of electrode were lowest for GMAW processes such as pulsed-spray mode (0.2 mg/g), and highest for SMAW (8 mg fume/g electrode). Emission rates of Cr(6+) ranged from 50-7800 µg/min, and Cr(6+) generation rates per g electrode ranged from 1-270 µg/g. Elemental Cr generation rates spanned 13-330 µg/g. Manganese emission rates ranged from 50-300 µg/g. Nickel emission rates ranged from 4-140 µg/g. Labor and consumables costs ranged from $3.15 (GMAW pulsed spray) to $7.40 (SMAW) per meter of finished weld, and were measured or estimated for all 11 processes tested. Equipment costs for some processes may be as much as five times the cost of a typical SMAW welding machine. The results show that all of the GMAW processes in this study can substantially reduce fume, Cr(6+), manganese and costs relative to SMAW, the most commonly used welding process, and several have exceptional capabilities for reducing emissions.


Assuntos
Poluentes Ocupacionais do Ar/análise , Cromo/análise , Exposição Ocupacional/análise , Aço Inoxidável , Soldagem/métodos , Local de Trabalho , Poluentes Ocupacionais do Ar/economia , Gases/análise , Metais/análise , Exposição Ocupacional/prevenção & controle , Soldagem/economia
14.
J Appl Toxicol ; 36(1): 161-74, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25926378

RESUMO

Inhalation exposure to multi-walled carbon nanotubes (MWCNT) in mice results in inflammation, fibrosis and the promotion of lung adenocarcinoma; however, the molecular basis behind these pathologies is unknown. This study determined global mRNA and miRNA profiles in whole blood from mice exposed by inhalation to MWCNT that correlated with the presence of lung hyperplasia, fibrosis, and bronchiolo-alveolar adenoma and adenocarcinoma. Six-week-old, male, B6C3F1 mice received a single intraperitoneal injection of either the DNA-damaging agent methylcholanthrene (MCA, 10 µg g(-1) body weight) or vehicle (corn oil). One week after injections, mice were exposed by inhalation to MWCNT (5 mg m(-3), 5 hours per day, 5 days per week) or filtered air (control) for a total of 15 days. At 17 months post-exposure, mice were euthanized and examined for the development of pathological changes in the lung, and whole blood was collected and analyzed using microarray analysis for global mRNA and miRNA expression. Numerous mRNAs and miRNAs in the blood were significantly up- or down-regulated in animals developing pathological changes in the lung after MCA/corn oil administration followed by MWCNT/air inhalation, including fcrl5 and miR-122-5p in the presence of hyperplasia, mthfd2 and miR-206-3p in the presence of fibrosis, fam178a and miR-130a-3p in the presence of bronchiolo-alveolar adenoma, and il7r and miR-210-3p in the presence of bronchiolo-alveolar adenocarcinoma, among others. The changes in miRNA and mRNA expression, and their respective regulatory networks, identified in this study may potentially serve as blood biomarkers for MWCNT-induced lung pathological changes.


Assuntos
Adenocarcinoma/genética , Adenoma/genética , Neoplasias Pulmonares/genética , Pulmão/patologia , MicroRNAs/sangue , Nanotubos de Carbono/toxicidade , Fibrose Pulmonar/genética , RNA Mensageiro/sangue , Adenocarcinoma/etiologia , Adenocarcinoma de Pulmão , Animais , Redes Reguladoras de Genes , Hiperplasia , Exposição por Inalação , Neoplasias Pulmonares/etiologia , Masculino , Camundongos
15.
PLoS One ; 10(3): e0120308, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25799419

RESUMO

Ambient bioaerosols are ubiquitous in the daily environment and can affect health in various ways. However, few studies have been conducted to comprehensively evaluate personal bioaerosol exposure in occupational and indoor environments because of the complex composition of bioaerosols and the lack of standardized sampling/analysis methods. We conducted a study to determine the most efficient collection/analysis method for the personal exposure assessment of multiple bioaerosols. The sampling efficiencies of three filters and four samplers were compared. According to our results, polycarbonate (PC) filters had the highest relative efficiency, particularly for bacteria. Side-by-side sampling was conducted to evaluate the three filter samplers (with PC filters) and the NIOSH Personal Bioaerosol Cyclone Sampler. According to the results, the Button Aerosol Sampler and the IOM Inhalable Dust Sampler had the highest relative efficiencies for fungi and bacteria, followed by the NIOSH sampler. Personal sampling was performed in a pig farm to assess occupational bioaerosol exposure and to evaluate the sampling/analysis methods. The Button and IOM samplers yielded a similar performance for personal bioaerosol sampling at the pig farm. However, the Button sampler is more likely to be clogged at high airborne dust concentrations because of its higher flow rate (4 L/min). Therefore, the IOM sampler is a more appropriate choice for performing personal sampling in environments with high dust levels. In summary, the Button and IOM samplers with PC filters are efficient sampling/analysis methods for the personal exposure assessment of multiple bioaerosols.


Assuntos
Aerossóis/análise , Exposição Ocupacional , Agricultura , Poluentes Ocupacionais do Ar/análise , Animais , Filtração , Humanos , Suínos
16.
Toxicology ; 328: 168-78, 2015 Feb 03.
Artigo em Inglês | MEDLINE | ID: mdl-25549921

RESUMO

Welding fumes (WF) are a complex mixture of toxic metals and gases, inhalation of which can lead to adverse health effects among welders. The presence of manganese (Mn) in welding electrodes is cause for concern about the potential development of Parkinson's disease (PD)-like neurological disorder. Consequently, from an occupational safety perspective, there is a critical need to prevent adverse exposures to WF. As the fume generation rate and physicochemical characteristics of welding aerosols are influenced by welding process parameters like voltage, current or shielding gas, we sought to determine if changing such parameters can alter the fume profile and consequently its neurotoxic potential. Specifically, we evaluated the influence of voltage on fume composition and neurotoxic outcome. Rats were exposed by whole-body inhalation (40 mg/m(3); 3h/day × 5 d/week × 2 weeks) to fumes generated by gas-metal arc welding using stainless steel electrodes (GMA-SS) at standard/regular voltage (25 V; RVSS) or high voltage (30 V; HVSS). Fumes generated under these conditions exhibited similar particulate morphology, appearing as chain-like aggregates; however, HVSS fumes comprised of a larger fraction of ultrafine particulates that are generally considered to be more toxic than their fine counterparts. Paradoxically, exposure to HVSS fumes did not elicit dopaminergic neurotoxicity, as monitored by the expression of dopaminergic and PD-related markers. We show that the lack of neurotoxicity is due to reduced solubility of Mn in HVSS fumes. Our findings show promise for process control procedures in developing prevention strategies for Mn-related neurotoxicity during welding; however, it warrants additional investigations to determine if such modifications can be suitably adapted at the workplace to avert or reduce adverse neurological risks.


Assuntos
Poluentes Ocupacionais do Ar/toxicidade , Encéfalo/efeitos dos fármacos , Exposição por Inalação/prevenção & controle , Intoxicação por Manganês/prevenção & controle , Manganês/toxicidade , Doença de Parkinson Secundária/prevenção & controle , Soldagem/métodos , Aerossóis , Poluentes Ocupacionais do Ar/química , Animais , Carga Corporal (Radioterapia) , Encéfalo/metabolismo , Neurônios Dopaminérgicos/efeitos dos fármacos , Neurônios Dopaminérgicos/metabolismo , Desenho de Equipamento , Regulação da Expressão Gênica/efeitos dos fármacos , Humanos , Exposição por Inalação/efeitos adversos , Masculino , Manganês/química , Intoxicação por Manganês/etiologia , Intoxicação por Manganês/genética , Intoxicação por Manganês/metabolismo , Doença de Parkinson Secundária/etiologia , Doença de Parkinson Secundária/genética , Doença de Parkinson Secundária/metabolismo , Tamanho da Partícula , Ratos Sprague-Dawley , Medição de Risco , Solubilidade , Fatores de Tempo , Soldagem/instrumentação
17.
Inhal Toxicol ; 26(12): 708-19, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25140455

RESUMO

Limited information exists regarding the health risks associated with inhaling aerosols that are generated during resistance spot welding of metals treated with adhesives. Toxicology studies evaluating spot welding aerosols are non-existent. A resistance spot welding aerosol generator and inhalation exposure system was developed. The system was designed by directing strips of sheet metal that were treated with an adhesive to two electrodes of a spot welder. Spot welds were made at a specified distance from each other by a computer-controlled welding gun in a fume collection chamber. Different target aerosol concentrations were maintained within the exposure chamber during a 4-h exposure period. In addition, the exposure system was run in two modes, spark and no spark, which resulted in different chemical profiles and particle size distributions. Complex aerosols were produced that contained both metal particulates and volatile organic compounds (VOCs). Size distribution of the particles was multi-modal. The majority of particles were chain-like agglomerates of ultrafine primary particles. The submicron mode of agglomerated particles accounted for the largest portion of particles in terms of particle number. Metal expulsion during spot welding caused the formation of larger, more spherical particles (spatter). These spatter particles appeared in the micron size mode and accounted for the greatest amount of particles in terms of mass. With this system, it is possible to examine potential mechanisms by which spot welding aerosols can affect health, as well as assess which component of the aerosol may be responsible for adverse health outcomes.


Assuntos
Adesivos/química , Poluentes Ocupacionais do Ar/toxicidade , Exposição por Inalação/efeitos adversos , Metais/química , Testes de Toxicidade/instrumentação , Soldagem , Aerossóis , Poluentes Ocupacionais do Ar/química , Animais , Animais de Laboratório , Câmaras de Exposição Atmosférica , Automação Laboratorial , Incêndios , Microscopia Eletrônica de Varredura , National Institute for Occupational Safety and Health, U.S. , Tamanho da Partícula , Material Particulado/química , Material Particulado/toxicidade , Aço/química , Estados Unidos , Compostos Orgânicos Voláteis/análise , Compostos Orgânicos Voláteis/química , Compostos Orgânicos Voláteis/toxicidade , Soldagem/métodos
18.
Environ Res ; 131: 71-6, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24657943

RESUMO

OBJECTIVES: Much scientific evidence indicates a positive association between moldy environments and respiratory illnesses and/or symptoms (e.g., asthma). Recently, submicron fungal fragments (<1.0 µm) have been suggested as a potential contributor to adverse health effects due to their biological composition (e.g., antigens, mycotoxins, and (1,3)-ß-D-glucan) as well as their small size. However, the contribution of exposure to fine fungal particles on adverse health outcomes has been poorly characterized, particularly in homes with asthmatic children. We characterized the airborne level of smaller-sized fungal particles between homes with and without asthmatic children. METHODS: We visited 29 homes with (n=15) and without (n=14) an asthmatic child and sampled submicron fungal fragments in a living room and child׳s bedroom, along with outdoor sampling, using the NIOSH two-stage sampler. (1,3)-ß-D-glucan of fungal fragments analyzed by Limulus Amebocyte lysate assay (LAL) was used for quantifying their exposure. RESULTS: Overall, the geometric mean (GM) concentration of (1,3)-ß-D-glucan in submicron fungal fragments in indoor air was two-fold higher in homes with asthmatic children (50.9 pg/m(3)) compared to homes with non-asthmatic children (26.7 pg/m(3)) (P<0.001). The GM concentration of these particles in child׳s bedroom in homes with an asthmatic child (66.1 pg/m(3)) was about three times higher than that in homes with non-asthmatic children (23.0 pg/m(3)) (P<0.001). The relative humidity had a negative correlation with the concentration of (1,3)-ß-D-glucan in submicron fungal fragments (Pearson coefficient=-0.257, P=0.046). CONCLUSIONS: Our findings indicate that homes with asthmatic children have a higher concentration of submicron fungal fragments compared to homes with non-asthmatic children. A greater exposure to smaller-sized fungal particles may occur in homes with an asthmatic child as relative humidity decreases. The very careful control of relative humidity in indoor air is necessary for reducing exposure to fine fungal particles and inhibiting the growth of microorganisms in homes with allergic diseases.


Assuntos
Asma/etiologia , Fungos , Material Particulado/efeitos adversos , Asma/microbiologia , Criança , Feminino , Habitação/estatística & dados numéricos , Humanos , Umidade , Masculino , Material Particulado/análise , Proteoglicanas , beta-Glucanas/análise
19.
Ann Occup Hyg ; 58(4): 403-12, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24515891

RESUMO

To provide quantitative information to choose the best welding processes for minimizing workplace emissions, nine gas metal arc welding (GMAW) processes for mild steel were assessed for fume generation rates, normalized fume generation rates (milligram fume per gram of electrode consumed), and normalized generation rates for elemental manganese, nickel, and iron. Shielded metal arc welding (SMAW) and flux-cored arc-welding (FCAW) processes were also profiled. The fumes were collected quantitatively in an American Welding Society-type fume chamber and weighed, recovered, homogenized, and analyzed by inductively coupled atomic emission spectroscopy for total metals. The processes included GMAW with short circuit, globular transfer, axial spray, pulsed spray, Surface Tension Transfer™, Regulated Metal Deposition™, and Cold Metal Transfer™ (CMT) modes. Flux-cored welding was gas shielded, and SMAW was a single rod type. Results indicate a wide range of fume emission factors for the process variations studied. Fume emission rates per gram of electrode consumed were highest for SMAW (~13 mg fume g(-1) electrode) and lowest for GMAW processes such as pulsed spray (~1.5mg g(-1)) and CMT (~1mg g(-1)). Manganese emission rates per gram of electrode consumed ranged from 0.45 mg g(-1) (SMAW) to 0.08 mg g(-1) (CMT). Nickel emission rates were generally low and ranged from ~0.09 (GMAW short circuit) to 0.004 mg g(-1) (CMT). Iron emission rates ranged from 3.7 (spray-mode GMAW) to 0.49 mg g(-1) (CMT). The processes studied have significantly different costs, and cost factors are presented based on a case study to allow comparisons between processes in specific cost categories. Costs per linear meter of weld were $31.07 (SMAW), $12.37 (GMAW short circuit), and $10.89 (FCAW). Although no single process is the best for minimizing fume emissions and costs while satisfying the weld requirements, there are several processes that can minimize emissions. This study provides information to aid in those choices. Suggestions for overcoming barriers to utilizing new and less hazardous welding processes are also discussed.


Assuntos
Poluentes Ocupacionais do Ar/análise , Poluentes Ocupacionais do Ar/economia , Exposição Ocupacional/análise , Soldagem/economia , Local de Trabalho , Monitoramento Ambiental/estatística & dados numéricos , Gases/química , Humanos , Metais/análise , Tamanho da Partícula , Aço/análise , Soldagem/métodos
20.
J Occup Environ Hyg ; 11(9): 591-603, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24568319

RESUMO

Respiratory problems are common among wildland firefighters. However, there are few studies directly linking occupational exposures to respiratory effects in this population. Our objective was to characterize wildland fire fighting occupational exposures and assess their associations with cross-shift changes in lung function. We studied 17 members of the Alpine Interagency Hotshot Crew with environmental sampling and pulmonary function testing during a large wildfire. We characterized particles by examining size distribution and mass concentration, and conducting elemental and morphological analyses. We examined associations between cross-shift lung function change and various analytes, including levoglucosan, an indicator of wood smoke from burning biomass. The levoglucosan component of the wildfire aerosol showed a predominantly bimodal size distribution: a coarse particle mode with a mass median aerodynamic diameter about 12 µm and a fine particle mode with a mass median aerodynamic diameter < 0.5 µm. Levoglucosan was found mainly in the respirable fraction and its concentration was higher for fire line construction operations than for mop-up operations. Larger cross-shift declines in forced expiratory volume in one second were associated with exposure to higher concentrations of respirable levoglucosan (p < 0.05). Paired analyses of real-time personal air sampling measurements indicated that higher carbon monoxide (CO) concentrations were correlated with higher particulate concentrations when examined by mean values, but not by individual data points. However, low CO concentrations did not provide reliable assurance of concomitantly low particulate concentrations. We conclude that inhalation of fine smoke particles is associated with acute lung function decline in some wildland firefighters. Based on short-term findings, it appears important to address possible long-term respiratory health issues for wildland firefighters. [Supplementary materials are available for this article. Go to the publisher's online edition of Journal of Occupational and Environmental Hygiene for the following free supplemental resources: a file containing additional information on historical studies of wildland fire exposures, a file containing the daily-exposure-severity questionnaire completed by wildland firefighter participants at the end of each day, and a file containing additional details of the investigation of correlations between carbon monoxide concentrations and other measured exposure factors in the current study.].


Assuntos
Poluentes Ocupacionais do Ar/efeitos adversos , Bombeiros , Exposição por Inalação/efeitos adversos , Pulmão/fisiopatologia , Exposição Ocupacional/efeitos adversos , Fumaça/efeitos adversos , Adulto , Aerossóis/efeitos adversos , Aerossóis/análise , Aerossóis/química , Poluentes Ocupacionais do Ar/análise , Poluentes Ocupacionais do Ar/química , Biomarcadores/análise , Testes Respiratórios , Carbono/efeitos adversos , Carbono/análise , Monóxido de Carbono/efeitos adversos , Monóxido de Carbono/análise , Feminino , Volume Expiratório Forçado , Glucose/efeitos adversos , Glucose/análogos & derivados , Glucose/análise , Glucose/química , Humanos , Exposição por Inalação/análise , Masculino , Exposição Ocupacional/análise , Tamanho da Partícula , Dióxido de Silício/efeitos adversos , Dióxido de Silício/análise , Fumaça/análise , Espirometria , Inquéritos e Questionários
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...