Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Clin Endocrinol Metab ; 97(12): E2297-306, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23087323

RESUMO

OBJECTIVE: Our objective was to verify the analytical performance of the Afirma gene expression classifier (GEC) in the classification of cytologically indeterminate thyroid nodule fine-needle aspirates (FNAs). DESIGN: Analytical performance studies were designed to characterize the stability of RNA in FNAs during collection and shipment, analytical sensitivity as applied to input RNA concentration and malignant/benign FNA mixtures, analytical specificity (i.e. potentially interfering substances) as tested on blood and genomic DNA, and assay performance studies including intra-nodule, intraassay, inter-assay, and inter-laboratory reproducibility. RESULTS: RNA content within FNAs preserved in FNAProtect is stable for up to 6 d at room temperature with no changes in RNA yield (P = 0.58) or quality (P = 0.56). FNA storage and shipping temperatures were found to have no significant effect on GEC scores (P = 0.55) or calls (100% concordance). Analytical sensitivity studies demonstrated tolerance to variation in RNA input (5-25 ng) and to the dilution of malignant FNA material down to 20%. Analytical specificity studies using malignant samples mixed with blood (up to 83%) and genomic DNA (up to 30%) demonstrated negligible assay interference with respect to false-negative calls, although benign FNA samples mixed with relatively high proportions of blood demonstrated a potential for false-positive calls. The test is reproducible from extraction through GEC result, including variation across operators, runs, reagent lots, and laboratories (sd of 0.158 for scores on a >6 unit scale). CONCLUSIONS: Analytical sensitivity, analytical specificity, robustness, and quality control of the GEC were successfully verified, indicating its suitability for clinical use.


Assuntos
Técnicas de Diagnóstico Endócrino , Técnicas de Diagnóstico Molecular/métodos , Nódulo da Glândula Tireoide/diagnóstico , Nódulo da Glândula Tireoide/patologia , Biópsia por Agulha Fina , Estudos de Casos e Controles , Diagnóstico Diferencial , Eficiência , Humanos , Modelos Biológicos , Técnicas de Diagnóstico Molecular/normas , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Manejo de Espécimes/métodos , Nódulo da Glândula Tireoide/sangue , Nódulo da Glândula Tireoide/genética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...