Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 163
Filtrar
1.
Artigo em Chinês | MEDLINE | ID: mdl-38677996

RESUMO

Food poisoning caused by Nassariidaes has occurred frequently in coastal areas of China, especially in summer and autumn. Nassariidaes poisoning can be manifested as lip and tongue paralysis, dizziness, headache, nausea and vomiting, arrhythmia and even respiratory failure. We admitted a case of respiratory failure caused by eating Nassariidaes. After timely respiratory support, hemoperfusion and other active treatment, the patient was recovered and was discharged. This paper summarized clinical characteristics and treatment of Nassariidaes poisoning, in order to provide reference for clinical diagnosis and treatment of similar cases.


Assuntos
Insuficiência Respiratória , Humanos , Insuficiência Respiratória/terapia , Insuficiência Respiratória/etiologia , Masculino , Animais , Doenças Transmitidas por Alimentos/terapia , Adulto , Pessoa de Meia-Idade
2.
Opt Express ; 32(7): 12982-12991, 2024 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-38571104

RESUMO

Quantum dense metrology (QDM) performs high-precision measurements by a two-mode entangled state created by an optical parametric amplifier (PA), where one mode is a meter beam and the other is a reference beam. In practical applications, the photon losses of meter beam are unavoidable, resulting in a degradation of the sensitivity. Here, we employ coherent feedback that feeds the reference beam back into the PA by a beam splitter to enhance the sensitivity in a lossy environment. The results show that the sensitivity is enhanced significantly by adjusting the splitting ratio of the beam splitter. This method may find its potential applications in QDM. Furthermore, such a strategy that two non-commuting observables are simultaneous measurements could provide a new way to individually control the noise-induced random drift in phase or amplitude of the light field, which would be significant for stabilizing the system and long-term precision measurement.

3.
Zhonghua Wei Chang Wai Ke Za Zhi ; 27(2): 127-131, 2024 Feb 25.
Artigo em Chinês | MEDLINE | ID: mdl-38413077

RESUMO

Due to the unique nature of its anatomical location, the adenocarcinoma of esophagogastric junction (AEG) has been a subject of controversy and disagreement including its definition, staging, and treatment strategies. Chinse expert Consensus on Surgical Treatment of Adenocarcinoma of Esophagogastric Junction in China (2018 Edition) had been released in September 2018 and had played a pioneering role in unifying thoracic and general surgeons in China on surgical treatment strategies for AEG. Over the past five years, the emergence of several clinical research results on AEG has provided new clinical evidence for the selection of key surgical treatment strategies. Therefore, to further standardize the surgical treatment of AEG in China, Chinese Expert Consensus on Surgical Treatment of Adenocarcinoma of Esophagogastric Junction in China (2024 Edition) was released in 2024 by Chinese expert panel including 25 gastrointestinal surgeons and 24 thoracic surgeons. Based on the highest-level clinical research evidence in recent 5 years, this consensus ultimately formulates 29 recommendations on hotspots and key points on surgical treatment of AEG and summary 5 issues that are still awaiting further exploration. This review will provide a summary and detailed interpretation of the recommendations outlined in this consensus.


Assuntos
Adenocarcinoma , Neoplasias Esofágicas , Neoplasias Gástricas , Humanos , Consenso , Neoplasias Gástricas/patologia , Adenocarcinoma/patologia , Neoplasias Esofágicas/patologia , Junção Esofagogástrica/cirurgia , Junção Esofagogástrica/patologia
4.
Ultrasound Obstet Gynecol ; 63(4): 522-528, 2024 04.
Artigo em Inglês | MEDLINE | ID: mdl-37767731

RESUMO

OBJECTIVE: Radiofrequency ablation (RFA) is the preferred approach for selective reduction in complex monochorionic (MC) multiple pregnancies owing to the ease of operation and minimal invasiveness. To optimize the RFA technique and reduce the risk of adverse pregnancy outcome resulting from the heat-sink effect of RFA therapy, we used an innovative RFA method, in which an electrode needle was expanded incrementally and stepwise. This study aimed to assess the efficacy and safety profile of this novel multistep incremental expansion RFA method for selective fetal reduction in MC twin and triplet pregnancies. METHODS: This was a single-center retrospective cohort study of all MC multiple pregnancies undergoing RFA between March 2016 and October 2022 at our center. The multistep RFA technique involved the use of an expandable needle, which was gradually expanded during the RFA procedure until cessation of umbilical cord blood flow was achieved. The needle used for the single-step RFA method was fully extended from the start of treatment. RESULTS: In total, 132 MC multiple pregnancies underwent selective reduction using RFA, including 50 cases undergoing multistep RFA and 82 cases undergoing single-step RFA. The overall survival rates were not significantly different between the multistep and single-step RFA groups (81.1% vs 72.3%; P = 0.234). Similarly, the rates of preterm prelabor rupture of the membranes within 2 weeks after RFA, procedure-related complications, spontaneous preterm delivery and pathological findings on cranial ultrasound, as well as gestational age at delivery and birth weight, did not differ between the two groups. However, there was a trend towards a prolonged procedure-to-delivery interval following multistep RFA compared with single-step RFA (median, 109 vs 99 days; P = 0.377). Moreover, the fetal loss rate within 2 weeks after RFA in the multistep RFA group was significantly lower than that in the single-step RFA group (10.0% vs 24.4%; P = 0.041). The median ablation time was shorter (5.3 vs 7.8 min; P < 0.001) and the median ablation energy was lower (10.2 vs 18.0 kJ; P < 0.001) in multistep compared with single-step RFA. There were no significant differences in neonatal outcomes following multistep vs single-step RFA. CONCLUSIONS: Overall survival rates were similar between the two RFA methods. However, the multistep RFA technique was associated with a lower risk of fetal loss within 2 weeks after RFA. The multistep RFA technique required significantly less ablation energy and a shorter ablation time compared with single-step RFA in selective fetal reduction of MC twin and triplet pregnancies. Additionally, there was a trend towards a prolonged procedure-to-delivery interval with the multistep RFA technique. © 2023 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.


Assuntos
Ablação por Cateter , Gravidez de Trigêmeos , Ablação por Radiofrequência , Recém-Nascido , Feminino , Gravidez , Humanos , Gravidez de Gêmeos , Estudos Retrospectivos , Redução de Gravidez Multifetal/métodos , Ablação por Cateter/métodos , Resultado da Gravidez , Ablação por Radiofrequência/métodos , Idade Gestacional
5.
Phys Rev Lett ; 131(15): 150804, 2023 Oct 13.
Artigo em Inglês | MEDLINE | ID: mdl-37897768

RESUMO

A quantum memory with the performances of low noise, high efficiency, and high bandwidth is of crucial importance for developing practical quantum information technologies. However, the excess noises generated during the highly efficient processing of quantum information inevitably destroy quantum state. Here, we present a quantum memory with built-in excess-noise eraser by integrating a photon-correlated quantum interferometry in quantum memory, where the memory efficiency can be enhanced and the excess noises can be suppressed to the vacuum level via destructive interference. This quantum memory is demonstrated in a rubidium vapor cell with a 10-ns-long photonics signal. We observe ∼80% noise suppression, the write-in efficiency enhancement from 87% to 96.2% without and with interferometry, and the corresponding memory efficiency excluding the noises from 70% to 77%. The fidelity is 93.7% at the single-photon level, significantly exceeding the no-cloning limit. Such interferometry-integrated quantum memory, the first expansion of quantum interference techniques to quantum information processing, simultaneously enables low noise, high bandwidth, high efficiency, and easy operation.

6.
Opt Express ; 31(21): 34779-34788, 2023 Oct 09.
Artigo em Inglês | MEDLINE | ID: mdl-37859226

RESUMO

We demonstrate an atomic magnetometry using amplitude-modulated pumping and hyperfine repumping techniques in a paraffin-coated cell. By exploiting the constructive interference between spins polarized by the pump beam and an additional repump beam, we observe a three-fold increase in the amplitude of magnetic resonance, along with a reduction in linewidth by approximately two times. The implementation of the repump beam effectively narrows the linewidth, demonstrating successful suppression of spin-exchange relaxation. This reduction in relaxation rate, combined with the enhanced signal, significantly improves the sensitivity of the magnetometer. Consequently, our technique offers a promising approach for achieving SERF-like magnetometry with sub-fT-level sensitivity in Earth-field range and room-temperature environment.

7.
Phys Rev Lett ; 130(7): 073601, 2023 Feb 17.
Artigo em Inglês | MEDLINE | ID: mdl-36867793

RESUMO

Interferometers are crucial for precision measurements, including gravitational waves, laser ranging, radar, and imaging. The phase sensitivity, the core parameter, can be quantum-enhanced to break the standard quantum limit (SQL) using quantum states. However, quantum states are highly fragile and quickly degrade with losses. We design and demonstrate a quantum interferometer utilizing a beam splitter with a variable splitting ratio to protect the quantum resource against environmental impacts. The optimal phase sensitivity can reach the quantum Cramér-Rao bound of the system. This quantum interferometer can greatly reduce the quantum source requirements in quantum measurements. In theory, with a 66.6% loss rate, the sensitivity can break the SQL using only a 6.0 dB squeezed quantum resource with the current interferometer rather than a 24 dB squeezed quantum resource with a conventional squeezing-vacuum-injected Mach-Zehnder interferometer. In experiments, when using a 2.0 dB squeezed vacuum state, the sensitivity enhancement remains at ∼1.6 dB via optimizing the first splitting ratio when the loss rate changes from 0% to 90%, indicating that the quantum resource is excellently protected with the existence of losses in practical applications. This strategy could open a way to retain quantum advantages for quantum information processing and quantum precision measurement in lossy environments.

8.
Zhonghua Er Bi Yan Hou Tou Jing Wai Ke Za Zhi ; 57(9): 1087-1094, 2022 Sep 07.
Artigo em Chinês | MEDLINE | ID: mdl-36177563

RESUMO

Objective: To standardize the 12-item reflux symptom scale in Chinese and evaluate its reliability, validity, and effect on diagnoses. Methods: A systematic translation version of the RSS-12 scale was performed using the Brislin model. The scale with 12 items included three dimensions of symptoms in ear, nose and throat, gastrointestinal tract and respiratory tract. The effect was assessed by three aspects containing symptom frequency, severity, and the quality of life. The Chinese version of RSS-12 was used to test 432 patients who attended the outpatient ENT department of Fujian Provincial Hospital between March 2021 and December 2021, and 413 patient questionnaires were classified as valid, aged 17-78(40.8±13.3) years, 203 were female and 210 were male. SPSS 26.0 and AMOS 24.0 statistical software were used to evaluate the performance of the scale. Results: The scale was highly discriminatory among items and correlated well among dimensions. The I-CVI ranged from 0.67 to 1.00, and the S-CVI was 0.81. The exploratory factor analysis showed that the cumulative variance contribution was 63.583%. The validation factor analysis showed that the model adaptation was good, and the correlation coefficient with the RSI was 0.796. Cronbach's α coefficient was 0.814, the retest reliability was 0.939, and the Spearman-Brown half reliability was 0.892, all of which showed a high level of reliability. Using 24h MII-pH as the diagnostic criterion for LPRD, the RSS-12 scale had a diagnostic compliance rate of 79.4%, with a sensitivity of 0.768 and specificity of 0.857. Conclusion: The Chinese version of the RSS-12 scale has good reliability, validity, and diagnostic ability, which can be used as a screening tool to diagnose pharyngeal reflux diseases.


Assuntos
Refluxo Gastroesofágico , Qualidade de Vida , China , Feminino , Refluxo Gastroesofágico/diagnóstico , Humanos , Masculino , Reprodutibilidade dos Testes , Inquéritos e Questionários , Traduções
9.
Eur Rev Med Pharmacol Sci ; 26(8): 3001-3009, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35503600

RESUMO

OBJECTIVE: Myocardial ischemia-reperfusion (I/R) injury (MIRI) is an important cause of irreversible injury to the myocardium in patients with acute myocardial infarction. The purpose of this study was to investigate the effects of minocycline (MC) on inflammation, oxidative stress and apoptosis of myocardial tissues. MATERIALS AND METHODS: We used rats to establish MIRI model by ligating coronary arteries. The structure and function of rat myocardium were determined by 2, 3, 5-triphenyl tetrazolium chloride (TTC) staining, hematoxylin-eosin (HE) staining and echocardiography. In addition, we detected the expression of inflammatory factors, antioxidant enzymes and apoptosis-related molecules in rats by enzyme-linked immunosorbent assay (ELISA), immunohistochemical (IHC) staining and reverse transcription-polymerase chain reaction (RT-PCR) to determine the effect of MC on inflammation, oxidative stress and apoptosis in I/R rats. Finally, we studied the effect of MC stimulation on the viability of rat cardiomyocytes (H9c2 cells) in vitro. RESULTS: After I/R, the heart function of rats decreased, and the structure of myocardium was destroyed. The levels of inflammation and oxidative stress in I/R rats also increased significantly, manifested by increased inflammatory factors and decreased antioxidant enzymes in serum and myocardial tissue. After treatment of I/R rats with MC, the structure and function of rat myocardium improved significantly, and MC reduced inflammation and oxidative stress levels in rats, thus inhibiting the apoptosis of cardiomyocytes. MC also improved the viability of H9c2 cells in vitro. CONCLUSIONS: MC reduced inflammation and oxidative stress levels in MIRI rat model or H9c2 cells, thus inhibiting cardiomyocyte apoptosis. Therefore, MC has potential application prospects for the treatment of MIRI.


Assuntos
Traumatismo por Reperfusão Miocárdica , Animais , Antioxidantes/farmacologia , Apoptose , Humanos , Inflamação/metabolismo , Minociclina/farmacologia , Traumatismo por Reperfusão Miocárdica/metabolismo , Miócitos Cardíacos/metabolismo , Estresse Oxidativo , Ratos , Ratos Sprague-Dawley , Transdução de Sinais
10.
Zhonghua Wei Chang Wai Ke Za Zhi ; 25(2): 109-113, 2022 Feb 25.
Artigo em Chinês | MEDLINE | ID: mdl-35176820

RESUMO

A greater controversy remains in clinical diagnosis and treatment of Siewert type II adenocarcinoma of esophagogastric junction (AEG), compared with Siewert type I and III AEG. In 2018, the first edition of Chinese Expert Consensus on the Surgical Treatment for Adenocarcinoma of Esophagogastric Junction was published in the Chinese Journal of Gastrointestinal Surgery. In the past few years, the advance in minimally invasive thoracoscopic surgery has been proven to reduce thoracic trauma in Siewert type II AEG. Meanwhile, distal thoracic esophagectomy can achieve more complete resection, and upper abdomen-right thoracic approach can ensure the mediastinal lymph node dissection and improve long-term survival. The concept and practice of endoscopic surgery and the comprehensive treatment also give new supplements to the treatment regimen of Siewert type II AEG. More clinical researches should be conducted to address the surgical residual safety and lymph node dissection issues.


Assuntos
Adenocarcinoma , Neoplasias Esofágicas , Neoplasias Gástricas , Cirurgia Torácica , Adenocarcinoma/patologia , Neoplasias Esofágicas/patologia , Neoplasias Esofágicas/cirurgia , Junção Esofagogástrica/patologia , Junção Esofagogástrica/cirurgia , Gastrectomia , Humanos , Excisão de Linfonodo , Estudos Retrospectivos , Neoplasias Gástricas/cirurgia
11.
Opt Express ; 29(21): 32865-32874, 2021 Oct 11.
Artigo em Inglês | MEDLINE | ID: mdl-34809109

RESUMO

The measurement of intense E-field is a fundamental need in various research areas. An electro-optic (EO) sensor based on common path interferometer (CPI) is widely used due to its better temperature stability and controllability of optical bias. However, the small EO coefficient leads to poor sensitivity. In this paper, a quantum enhanced EO sensor is proposed by replacing the vacuum state in classical one with a squeezed-vacuum state. Theoretical analysis shows that the performance of the quantum enhanced EO sensor, including signal to noise ratio (SNR) and sensitivity, can always beat the classical one due to the noise suppression caused by the squeezed-vacuum state. Experimental results demonstrate that, there is still a 1.12dB quantum enhancement compared with the classical one when the degree of the squeezed-vacuum is 1.60dB. More importantly, except the increase of the EO coefficient or the optical power, the performance of the EO sensor can also be enhanced via quantum light source. Such a quantum enhanced EO sensor could be practically applied for the measurement of intense E-field.

12.
Nat Commun ; 12(1): 6784, 2021 Nov 22.
Artigo em Inglês | MEDLINE | ID: mdl-34811372

RESUMO

The control of the in-plane domain evolution in ferroelectric thin films is not only critical to understanding ferroelectric phenomena but also to enabling functional device fabrication. However, in-plane polarized ferroelectric thin films typically exhibit complicated multi-domain states, not desirable for optoelectronic device performance. Here we report a strategy combining interfacial symmetry engineering and anisotropic strain to design single-domain, in-plane polarized ferroelectric BaTiO3 thin films. Theoretical calculations predict the key role of the BaTiO3/PrScO3 [Formula: see text] substrate interfacial environment, where anisotropic strain, monoclinic distortions, and interfacial electrostatic potential stabilize a single-variant spontaneous polarization. A combination of scanning transmission electron microscopy, piezoresponse force microscopy, ferroelectric hysteresis loop measurements, and second harmonic generation measurements directly reveals the stabilization of the in-plane quasi-single-domain polarization state. This work offers design principles for engineering in-plane domains of ferroelectric oxide thin films, which is a prerequisite for high performance optoelectronic devices.

13.
Zhonghua Yi Xue Za Zhi ; 101(37): 2993-2998, 2021 Oct 12.
Artigo em Chinês | MEDLINE | ID: mdl-34638190

RESUMO

Objective: To determinate the block range of lumbar erector spinal plane (ESPB), and investigate the efficacy of ESPB in lumbar spine surgery. Methods: Forty patients who underwent posterior lumbar fusion in the Second Affiliated Hospital of Wenzhou Medical University from November 2019 to August 2020 were randomly divided into two groups (with n=20 in each group) using the random number table: the experimental group (group E) and control group (group C). All the patients received ultrasound-guided bilateral ESPB with 20 ml of 0.375% ropivacaine (group E) or equal volume of normal saline (group C) on each side before induction of general anesthesia. The range of weakened temperature sense in each patient was measured at 10 min, 20 min and 30 min after ESPB, respectively. Dosage of analgesic drug, visual analog scale (VAS), and incidence of adverse events were recorded and compared between the two groups. Results: In group E, the dermatomal distribution and area of weakened temperature sense at 10 min, 20 min, 30 min after ESPB were T9-S1 (222±16) cm2, T8-S2 (352±22) cm2, T8-S3 (481±24) cm2, respectively. The intraoperative dosage of remifentanil in group E was (0.76±0.02) mg, which was significantly lower than that of group C (0.97±0.06) mg (P<0.05). Oxycodone consumption in group E at 0-12 h and 12-24 h after surgery was (4.9±0.4) mg and (8.4±1.2) mg, respectively, which were lower than those in group C [(14.5±2.4) mg and (19.3±2.4) mg, respectively] (both P<0.05). The VAS during rest and movement within 24 h after operation in group E were significantly lower than those in group C (both P<0.05). The passive exercise in bed in group E started at (3.3±0.3) h postoperatively, which was earlier than that in group C (4.6±0.3) h (P<0.05). Conclusion: The blocking effects of T12-S1 segment after ultrasound-guided lumbar ESPB is definite, which can effectively decrease the amounts of analgesics during and after the lumbar fusion surgery, reduce postoperative rest and exercise VAS score, and contribute to a rapid recovery of the patients.


Assuntos
Bloqueio Nervoso , Humanos , Região Lombossacral , Dor Pós-Operatória , Ultrassonografia , Ultrassonografia de Intervenção
14.
Zhonghua Fu Chan Ke Za Zhi ; 56(9): 598-608, 2021 Sep 25.
Artigo em Chinês | MEDLINE | ID: mdl-34547860

RESUMO

Objective: To investigate the clinical characteristics and perinatal outcomes of pregnancy with placental cystic lesions. Methods: A retrospective study was carried out on 48 pregnant women diagnosed as pregnancy complicated with placental cystic lesions from January 2000 to January 2020 at the Women's Hospital, Zhejiang University School of Medicine. The clinical features, pathological diagnosis and perinatal outcome were analyzed. Results: The age of 48 cases was (30±5) years, and the diagnostic gestational week of ultrasound was (24±8) weeks. Twenty-five cases in which showed a cystic mass at the fetal surface were diagnosed as placental cyst. The live birth rate was 100% (25/25) and the premature birth rate was 20% (5/25). Twenty-three cases showed "honeycomb like" cystic echo. Cystic lesions of 10 cases were located in the uterine cavity connected with the margin of the normal placenta, and finally diagnosed as hydatidiform mole and coexisting fetus (HMCF). Six cases of HMCF terminated pregnancy, and the live birth rate was 4/10, the premature delivery rate was 2/4. Cystic lesions of 13 cases were located in the placenta substance, and finally diagnosed as 4 cases of placental mesenchymal dysplasia (PMD) and 9 cases of focal chorionic edema; the live birth rate was 6/13 and the premature delivery rate was 4/6. The median hCG was lower in focal chorionic edema group [80 kU/L (60-110 kU/L)] than in the groups of HMCF [240 kU/L (180-430 kU/L)] and PMD [360 kU/L (210-700 kU/L)], and the differences were statistically significant (all P<0.01). Conclusions: For pregnancy complicated with placental cystic lesions, prenatal ultrasound should be performed to evaluate the shape, location and blood flow of the lesions. Maternal serological examination and invasive prenatal diagnosis are helpful for prenatal diagnosis and treatment. Due to the difference of perinatal outcomes, maternal and fetal complications, individualized pregnancy management should be carried out.


Assuntos
Mola Hidatiforme , Doenças Placentárias , Neoplasias Uterinas , Adulto , Feminino , Humanos , Placenta/diagnóstico por imagem , Doenças Placentárias/diagnóstico por imagem , Doenças Placentárias/epidemiologia , Gravidez , Resultado da Gravidez , Estudos Retrospectivos
16.
Zhonghua Wai Ke Za Zhi ; 59(8): 651-654, 2021 Aug 01.
Artigo em Chinês | MEDLINE | ID: mdl-34192856

RESUMO

Associated with improvement in survival, the neoadjuvant therapy had become the mainstay of therapy for patients with locally advanced esophageal cancer. Despite a significantly better survival, the recurrence risk after neoadjuvant therapy remains considerably high, with recurrence rate of>40%. Thus, it's important to gain a thorough understanding of the recurrence patterns for developing effective tertiary prevention and follow-up strategies. The aim of this review was to compare the patterns of recurrence in patients with esophageal cancer who received preoperative therapy followed by surgery or surgery alone. It is found that the most frequent recurrence pattern was distant metastasis in esophageal cancer regardless receipt of neoadjuvant therapy or not, and the major effect of neoadjuvant therapy appears to be an improvement in local regional disease control without a reduction in systemic. This frustrating fact may explain the poor survival of esophageal cancer patients receiving neoadjuvant therapy.

17.
Zhonghua Wai Ke Za Zhi ; 59(8): 660-666, 2021 Aug 01.
Artigo em Chinês | MEDLINE | ID: mdl-34192858

RESUMO

Objective: To examine the correlation between neutrophil-lymphocyte ratio (NLR), lymphocyte-monocyte ratio (LMR) and neutrophil-monocyte ratio (NMR) for postoperative pneumonia or long-term overall survival in patients with esophageal cancer after neoadjuvant therapy. Methods: The clinical data of 137 patients, including 111 males and 26 females, with the age of (M(QR))61(10) years (range: 45 to 75 years), undergoing radical resection of esophageal cancer after neoadjuvant therapy admitted at Department of Thoracic Surgery, West China Hospital from January 2016 to May 2019 were analyzed retrospectively. The blood routine one or two days before surgery and the occurrence of pneumonia after surgery were collected via hospital information system. The absolute count of neutrophils, lymphocytes and monocytes was recorded, to calculate NLR, LMR and NMR. The survival of patients was recorded systematically via follow-up. In the first part, the influencing factors of postoperative inflammation were analyzed, to group the patients into two groups according to the occurrence of postoperative pneumonia. χ2 test, t-test or rank-sum test were conducted for inter-group comparison. In the second part, cutoff values of inflammatory biomarkers were obtained with the receiver operating characteristic (ROC) curve and grouped, with postoperative pneumonia as endpoint criteria. Independent factors correlated with postoperative pneumonia were determined through univariate and multivariate Logistic regression analysis. In the third part, the analysis on prognosis factors was carried on, with the survival as endpoint criteria. Cutoff values of inflammatory biomarkers were obtained with X-Tile software and grouped. The survival analysis was carried on with univariate and multivariate Cox proportional hazards regression model, and the Kaplan-Meier curve was drawn finally. The results of survival analysis were verified by Log-rank test. Results: Median follow-up time was 614 (299) days (range: 382 to 1 612 days). Cutoff values of NLR, LMR, and NMR obtained via the ROC curve were 3.0, 3.9, and 6.2, respectively. According to the multivariate Logistic regression analysis, NLR>3.0 (OR=2.740, 95% CI: 1.221 to 6.152, P=0.015) and LMR>3.9 (OR=0.140, 95% CI: 0.022 to 0.890, P=0.037) were independent prognosis factors for postoperative pneumonia in patients with esophageal cancer after neoadjuvant therapy. Cutoff values of NLR, LMR, and NMR obtained with X-Tile software were 3.3, 4.2, and 7.2, respectively. Through multivariate Cox proportional risk regression analysis, late tumor ypTNM staging (8th AJCC) (HR=2.087, 95% CI:1.079 to 4.038, P=0.029), poor pathologic response (HR=2.251, 95% CI: 1.117 to 4.538, P=0.023), and LMR>4.2 (HR=0.347, 95% CI: 0.127 to 0.946, P=0.039) could be independent prognosis factors for overall survival. Kaplan-Meier survival analysis indicated that the overall survival of patients with LMR ≤4.2 was worse (P=0.002), with the 1-year overall survival rate of 82.9%, and the 1-year overall survival rate of patients with LMR>4.2 was 94.6%. Conclusion: Preoperative LMR ≤3.9 and NLR>3.0 can be considered as independent prognosis factors for postoperative pneumonia, while LMR≤4.2 as one of independent prognosis factors for overall survival.

18.
Rev Sci Instrum ; 92(4): 045103, 2021 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-34243417

RESUMO

A coil system to generate a uniform field is urgently needed in quantum experiments. However, general coil configurations based on the analytical method have not considered practical restrictions, such as the region for coil placement due to holes in the center of the magnetic shield, which could not be directly applied in most of the quantum experiments. In this paper, we develop a coil design method for quantum experiments using hybrid machine learning. The algorithm part consists of a machine learner based on an artificial neural network and a differential evolution (DE) learner. The cooperation of both learners demonstrates its higher efficiency than a single DE learner and robustness in the coil optimization problem compared with analytical proposals. With the help of a DE learner, in numerical simulation, a machine learner can successfully design coaxial coil systems that generate fields whose relative inhomogeneity in a 25 mm-long central region is ∼10-6 under constraints. In addition, for experiments, a coil system with 0.069% inhomogeneity of the field, designed by a machine learner, is constructed, which is mainly limited by machining the precision of the circuit board. Benefitting from machine learning's high-dimension optimization capabilities, our coil design method is convenient and has potential for various quantum experiments.

19.
Nat Commun ; 12(1): 2757, 2021 May 12.
Artigo em Inglês | MEDLINE | ID: mdl-33980848

RESUMO

Magnetostrictive materials transduce magnetic and mechanical energies and when combined with piezoelectric elements, evoke magnetoelectric transduction for high-sensitivity magnetic field sensors and energy-efficient beyond-CMOS technologies. The dearth of ductile, rare-earth-free materials with high magnetostrictive coefficients motivates the discovery of superior materials. Fe1-xGax alloys are amongst the highest performing rare-earth-free magnetostrictive materials; however, magnetostriction becomes sharply suppressed beyond x = 19% due to the formation of a parasitic ordered intermetallic phase. Here, we harness epitaxy to extend the stability of the BCC Fe1-xGax alloy to gallium compositions as high as x = 30% and in so doing dramatically boost the magnetostriction by as much as 10x relative to the bulk and 2x larger than canonical rare-earth based magnetostrictors. A Fe1-xGax - [Pb(Mg1/3Nb2/3)O3]0.7-[PbTiO3]0.3 (PMN-PT) composite magnetoelectric shows robust 90° electrical switching of magnetic anisotropy and a converse magnetoelectric coefficient of 2.0 × 10-5 s m-1. When optimally scaled, this high coefficient implies stable switching at ~80 aJ per bit.

20.
Fa Yi Xue Za Zhi ; 37(1): 26-32, 2021 Feb.
Artigo em Inglês, Chinês | MEDLINE | ID: mdl-33780181

RESUMO

ABSTRACT: Objective To establish a method using supramolecular solvent and gas chromatography-tandem mass spectrometry (GC-MS/MS) to analyze 9 benzodiazepines in urines. Methods Urine samples containing 9 benzodiazepines reference substance were subjected to liquid-liquid extractions with supramolecular solvent, which consisted of tetrahydrofuran and 1-hexanol. The solvent layer was evaporated to dryness by stream of nitrogen. The residue was reconstituted with methanol, and GC-MS/MS analysis was performed on it. The way of data collection was multiple reaction monitoring (MRM) mode; internal standard method was employed for quantification. Results In urine samples, when the range of mass concentration was 1-100 ng/mL for diazepam, midazolam, flunitrazepam and clozapine, 5-100 ng/mL for lorazepam and alprazolam, 2-100 ng/mL for nitrazepam and clonazepam, and 0.2-100 ng/mL for estazolam, respectively, good linearities were obtained, correlation coefficients were 0.999 1-0.999 9, the lower limits of the quantifications ranged from 0.2 to 5 ng/mL, the extraction recovery rates were 81.12%-99.52%. The intra-day precision [relative standard deviation (RSD)] and accuracy (bias) were lower than 9.86% and 9.51%, respectively; the inter-day precision (RSD) and accuracy (bias) were lower than 8.74% and 9.98%, respectively. Nine drugs in urine samples showed good stability at ambient temperature and -20 ℃ within 15 days. The mass concentrations of alprazolam in urine samples obtained from 8 volunteers who took alprazolam tablets orally within 8-72 h after ingestions ranged from 6.54 to 88.28 ng/mL. Conclusion The supramolecular solvent extraction GC-MS/MS method for analysis of 9 benzodiazepines in urines provided by this study is simple, fast, accurate and sensitive, which can provide technical support for monitoring of poisoning by benzodiazepines for clinical treatment and judicial identification.


Assuntos
Benzodiazepinas , Espectrometria de Massas em Tandem , Cromatografia Líquida , Cromatografia Gasosa-Espectrometria de Massas , Humanos , Solventes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...