Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 69
Filtrar
2.
J Alzheimers Dis ; 98(2): 563-577, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38427493

RESUMO

Background: Transcranial direct current stimulation (tDCS) is considered a potential therapeutic instrument for Alzheimer's disease (AD) because it affects long-term synaptic plasticity through the processes of long-term potentiation and long-term depression, thereby improving cognitive ability. Nevertheless, the efficacy of tDCS in treating AD is still debated. Dorsal lateral prefrontal cortex is the main role in executive functions. Objective: We investigate the cognitive effects of tDCS on AD patients. Methods: Thirty mild AD patients aged 66-86 years (mean = 75.6) were included in a double-blind, randomized, sham-controlled crossover study. They were randomly assigned to receive 10 consecutive daily sessions of active tDCS (2 mA for 30 min) or a sham intervention and switched conditions 3 months later. The anodal and cathodal electrodes were placed on the left dorsal lateral prefrontal cortex and the right supraorbital area, respectively. Subjects underwent various neuropsychological assessments before and after the interventions. Results: The results showed that tDCS significantly improved Cognitive Abilities Screening Instrument scores, especially on the items of "concentration and calculation", "orientation", "language ability", and "categorical verbal fluency". Mini-Mental State Examination and Wisconsin Card Sorting Test scores in all domains of "concept formation", "abstract thinking", "cognitive flexibility", and "accuracy" also improved significantly after tDCS. For the sham condition, no difference was found between the baseline scores and the after-intervention scores on any of the neuropsychological tests. Conclusion: >: Using tDCS improves the cognition of AD patients. Further large size clinical trials are necessary to validate the data.


Assuntos
Doença de Alzheimer , Estimulação Transcraniana por Corrente Contínua , Humanos , Estimulação Transcraniana por Corrente Contínua/métodos , Córtex Pré-Frontal Dorsolateral , Doença de Alzheimer/terapia , Estudos Cross-Over , Cognição , Método Duplo-Cego , Córtex Pré-Frontal/fisiologia
3.
PLoS One ; 18(12): e0295959, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38134043

RESUMO

Progestin-only injectable contraceptives, mainly depo-medroxyprogesterone acetate intramuscular (DMPA-IM), are the most widely used contraceptive methods in sub-Saharan Africa. Insufficient robust data on their relative side-effects and serum concentrations limit understanding of reported outcomes in contraception trials. The WHICH clinical trial randomized HIV-negative women to DMPA-IM (n = 262) or norethisterone enanthate (NET-EN) (n = 259) at two South African sites between 2018-2019. We measured serum concentrations of study and non-study progestins at initiation (D0) and peak serum levels, one week after the 24-week injection [25 weeks (25W)], (n = 435) and investigated associations between study progestin levels, and BMI and weight of participants. Peak median serum concentrations were 6.59 (IQR 4.80; 8.70) nM for medroxyprogesterone (MPA) (n = 161) and 13.6 (IQR 9.01; 19.0) nM for norethisterone (NET) (n = 155). MPA was the most commonly quantifiable non-study progestin at D0 in both arms (54%) and at 25W in the NET-EN arm (27%), followed by NET at D0 in both arms (29%) and at 25W in the DMPA-IM arm (19%). Levonorgestrel was quantifiable in both arms [D0 (6.9%); 25W (3.4%)], while other progestins were quantifiable in ≤ 14 participants. Significant negative time-varying associations were detected between MPA and NET concentrations and weight and BMI in both contraceptive arms and a significant increase was detected for peak serum progestin concentrations for normal weight versus obese women. Contraceptive-related reported outcomes are likely confounded by MPA, more so than NET, with reported DMPA-IM effects likely underestimated, at sites where DMPA-IM is widely used, due to misreporting of contraceptive use before and during trials, and 'tail' effects of DMPA-IM use more than six months before trial enrolment. Peak serum levels of MPA and NET are negatively associated with BMI and weight, suggesting another source of variability between trial outcomes and a potential increase in side-effects for normal weight versus overweight and obese women. Trail registration: The clinical trial was registered with the Pan African Clinical Trials Registry (PACTR 202009758229976).


Assuntos
Acetato de Medroxiprogesterona , Progestinas , Feminino , Humanos , Acetato de Medroxiprogesterona/efeitos adversos , Anticoncepcionais , Índice de Massa Corporal , Noretindrona/farmacologia , Obesidade
4.
PLoS One ; 18(11): e0294285, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37948399

RESUMO

BACKGROUND: South Africa is among the countries with the highest prevalence of sexually transmitted infections (STIs), including Chlamydia trachomatis (CT) and Neisseria gonorrhoeae (NG). In 2017, there were an estimated 6 million new CT, 4.5 million NG and 71 000 Treponema pallidum infections among South African men and women of reproductive age. METHODS: We evaluated STI prevalence and incidence and associated risk factors in 162 women aged 18-33 years old, residing in eThekwini and Tshwane, South Africa who were part of the Evidence for Contraceptive Options and HIV Outcomes (ECHO) trial. Women were randomised to use depot medroxyprogesterone acetate (n = 53), copper intrauterine device (n = 51), or levonorgestrel (n = 58) implant. Lateral vaginal wall swab samples were collected prior to contraceptive initiation and at months one and three following contraceptive initiation for STI testing. RESULTS: There were no significant differences in STI incidence and prevalence across contraceptive groups. At baseline, 40% had active STIs (CT, NG, Trichomonas vaginalis (TV), Mycoplasma genitalium (MG) or herpes simplex virus-2 shedding across all age groups- 18-21 years (46%), 22-25 years (42%) and 26-33 years (29%). The incidence of STIs during follow-up was exceptionally high (107.9/100 women-years [wy]), with younger women (18-21 years) more likely to acquire CT (75.9/100 wy) compared to 26-33 year olds (17.4/100 wy; p = 0.049). TV incidence was higher in the 26-33 year old group (82.7/100 wy) compared to the 18-21 year olds (8.4/100 wy; p = 0.01). CONCLUSIONS: Although the study participants received extensive counselling on the importance of condom use, this study highlights the high prevalence and incidence of STIs in South African women, especially amongst young women, emphasising the need for better STI screening and management strategies.


Assuntos
Infecções por Chlamydia , Infecções por HIV , Infecções Sexualmente Transmissíveis , Trichomonas vaginalis , Masculino , Humanos , Feminino , Adolescente , Adulto Jovem , Adulto , África do Sul/epidemiologia , Anticoncepcionais , Prevalência , Incidência , Infecções Sexualmente Transmissíveis/prevenção & controle , Chlamydia trachomatis , Neisseria gonorrhoeae , Infecções por HIV/epidemiologia , Infecções por HIV/prevenção & controle , Infecções por Chlamydia/epidemiologia , Infecções por Chlamydia/diagnóstico
5.
Sleep Health ; 9(4): 430-440, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37380590

RESUMO

GOAL AND AIMS: Our objective was to evaluate the performance of Belun Ring with second-generation deep learning algorithms in obstructive sleep apnea (OSA) detection, OSA severity categorization, and sleep stage classification. FOCUS TECHNOLOGY: Belun Ring with second-generation deep learning algorithms REFERENCE TECHNOLOGY: In-lab polysomnography (PSG) SAMPLE: Eighty-four subjects (M: F = 1:1) referred for an overnight sleep study were eligible. Of these, 26% had PSG-AHI<5; 24% had PSG-AHI 5-15; 23% had PSG-AHI 15-30; 27% had PSG-AHI ≥ 30. DESIGN: Rigorous performance evaluation by comparing Belun Ring to concurrent in-lab PSG using the 4% rule. CORE ANALYTICS: Pearson's correlation coefficient, Student's paired t-test, diagnostic accuracy, sensitivity, specificity, positive predictive value, negative predictive value, positive likelihood ratio, negative likelihood ratio, Cohen's kappa coefficient (kappa), Bland-Altman plots with bias and limits of agreement, receiver operating characteristics curves with area under the curve, and confusion matrix. CORE OUTCOMES: The accuracy, sensitivity, specificity, and kappa in categorizing AHI ≥ 5 were 0.85, 0.92, 0.64, and 0.58, respectively. The accuracy, sensitivity, specificity, and Kappa in categorizing AHI ≥ 15 were 0.89, 0.91, 0.88, and 0.79, respectively. The accuracy, sensitivity, specificity, and Kappa in categorizing AHI ≥ 30 were 0.91, 0.83, 0.93, and 0.76, respectively. BSP2 also achieved an accuracy of 0.88 in detecting wake, 0.82 in detecting NREM, and 0.90 in detecting REM sleep. CORE CONCLUSION: Belun Ring with second-generation algorithms detected OSA with good accuracy and demonstrated a moderate-to-substantial agreement in categorizing OSA severity and classifying sleep stages.


Assuntos
Aprendizado Profundo , Apneia Obstrutiva do Sono , Dispositivos Eletrônicos Vestíveis , Humanos , Sono , Apneia Obstrutiva do Sono/diagnóstico , Fases do Sono
6.
Sex Transm Infect ; 99(5): 311-316, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-36104248

RESUMO

OBJECTIVES: To examine innate immunity predictors of HIV-1 acquisition as biomarkers of HSV-2 risk and biological basis for epidemiologically established HIV-1 predisposition in HSV-2 infected women. METHODS: We analysed longitudinal samples from HIV-1 negative visits of 1019 women before and after HSV-2 acquisition. We measured cervical and serum biomarkers of inflammation and immune activation previously linked to HIV-1 risk. Protein levels were Box-Cox transformed and ORs for HSV-2 acquisition were calculated based on top quartile or below/above median levels for all HSV-2 negative visits. Bivariate analysis determined the likelihood of HSV-2 acquisition by biomarker levels preceding infection. Linear mixed-effects models evaluated if biomarkers differed by HSV-2 status defined as negative, incident or established infections with an established infection cut-off starting at 6 months. RESULTS: In the cervical compartment, two biomarkers of HIV-1 risk (low SLPI and high BD-2) also predicted HSV-2 acquisition. In addition, HSV-2 acquisition was associated with IL-1ß, IL-6, IL-8, MIP-3α, ICAM-1 and VEGF when below median levels. Systemic immunity predictors of HSV-2 acquisition were high sCD14 and IL-6, with highest odds when concomitantly increased (OR=2.23, 1.49-3.35). Concomitant systemic and mucosal predictors of HSV-2 acquisition risk included (1) serum top quartile sCD14 with cervical low SLPI, VEGF and ICAM-1, or high BD-2; (2) serum high IL-6 with cervical low VEGF and ICAM-1, SLPI, IL-1ß and IL-6; and (3) serum low C reactive protein with cervical high BD-2 (the only combination also predictive of HIV-1 acquisition). Most cervical biomarkers were decreased after HSV-2 acquisition compared with the HSV-2 negative visits, with incident infections associated with a larger number of suppressed cervical biomarkers and lower serum IL-6 levels compared with established infections. CONCLUSIONS: A combination of systemic immunoinflammatory and cervical immunosuppressed states predicts HSV-2 acquisition. A persistently suppressed innate immunity during incident HSV-2 infection may add to the increased HIV-1 susceptibility.


Assuntos
Infecções por HIV , Soropositividade para HIV , Herpes Genital , Feminino , Humanos , Herpes Genital/epidemiologia , Herpes Genital/complicações , Herpesvirus Humano 2 , Infecções por HIV/complicações , Molécula 1 de Adesão Intercelular/metabolismo , Interleucina-6 , Soroconversão , Fator A de Crescimento do Endotélio Vascular/metabolismo , Receptores de Lipopolissacarídeos , Soropositividade para HIV/complicações , Imunidade Inata , Biomarcadores
7.
AIDS Behav ; 27(3): 978-983, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36357806

RESUMO

The Evidence for Contraceptive Options and HIV Outcomes (ECHO) trial found no substantial difference in HIV acquisition risk between women randomised to injectable intramuscular depot medroxyprogesterone acetate (DMPA-IM), copper intrauterine device (Cu-IUD) or the levonorgestrel (LNG) implant. We evaluated post-randomization sexual behavior using an objective marker of condomless vaginal sex in a subset of participants. We conducted a sub-study among 458 ECHO participants at three sites (Cape Town, Johannesburg, Kisumu) to evaluate the frequency of condomless vaginal sex, measured by prostate specific antigen (PSA) detection in vaginal swabs, collected at the month 6 and final visit and the concordance of self-reported condomless vaginal sex with PSA detection, by randomized arm. We compared PSA detection frequency and concordance of PSA and self-reported condomless vaginal sex, by randomized group using Cochran-Mantel-Haenszel tests and adjusted generalized logistic growth curve models. PSA was detected less frequently in the DMPA-IM (16%), compared to the Cu-IUD (21%) and LNG implant (24%) groups, although results were not statistically significant in the unadjusted model when accounting for pre-specified multiple-testing criteria. There were significant differences in PSA detection between the DMPA-IM and LNG-implant groups (odds ratio 0.61 (95% CI 0.40, 0.94) in the adjusted model. There was moderate discordance between self-reported condomless vaginal sex and detection of PSA that was similar across randomized groups. These data suggest that women randomized to Cu-IUD and LNG implant may have had condomless sex more frequently than women randomized to DMPA-IM. The discordance between detectable PSA and self-reported sexual behaviour has important implications for design of future HIV prevention studies.


Assuntos
Anticoncepcionais Femininos , Infecções por HIV , Dispositivos Intrauterinos de Cobre , Masculino , Feminino , Humanos , Levanogestrel , Acetato de Medroxiprogesterona , Sexo sem Proteção , Antígeno Prostático Específico , Distribuição Aleatória , Infecções por HIV/diagnóstico , África do Sul
8.
JMIR AI ; 2: e44432, 2023 May 12.
Artigo em Inglês | MEDLINE | ID: mdl-38875546

RESUMO

BACKGROUND: Antiretroviral therapy (ART) has transformed HIV from a fatal illness to a chronic disease. Given the high rate of treatment interruptions, HIV programs use a range of approaches to support individuals in adhering to ART and in re-engaging those who interrupt treatment. These interventions can often be time-consuming and costly, and thus providing for all may not be sustainable. OBJECTIVE: This study aims to describe our experiences developing a machine learning (ML) model to predict interruption in treatment (IIT) at 30 days among people living with HIV newly enrolled on ART in Nigeria and our integration of the model into the routine information system. In addition, we collected health workers' perceptions and use of the model's outputs for case management. METHODS: Routine program data collected from January 2005 through February 2021 was used to train and test an ML model (boosting tree and Extreme Gradient Boosting) to predict future IIT. Data were randomly sampled using an 80/20 split into training and test data sets, respectively. Model performance was estimated using sensitivity, specificity, and positive and negative predictive values. Variables considered to be highly associated with treatment interruption were preselected by a group of HIV prevention researchers, program experts, and biostatisticians for inclusion in the model. Individuals were defined as having IIT if they were provided a 30-day supply of antiretrovirals but did not return for a refill within 28 days of their scheduled follow-up visit date. Outputs from the ML model were shared weekly with health care workers at selected facilities. RESULTS: After data cleaning, complete data for 136,747 clients were used for the analysis. The percentage of IIT cases decreased from 58.6% (36,663/61,864) before 2017 to 14.2% (3690/28,046) from October 2019 through February 2021. Overall IIT was higher among clients who were sicker at enrollment. Other factors that were significantly associated with IIT included pregnancy and breastfeeding status and facility characteristics (location, service level, and service type). Several models were initially developed; the selected model had a sensitivity of 81%, specificity of 88%, positive predictive value of 83%, and negative predictive value of 87%, and was successfully integrated into the national electronic medical records database. During field-testing, the majority of users reported that an IIT prediction tool could lead to proactive steps for preventing IIT and improving patient outcomes. CONCLUSIONS: High-performing ML models to identify patients with HIV at risk of IIT can be developed using routinely collected service delivery data and integrated into routine health management information systems. Machine learning can improve the targeting of interventions through differentiated models of care before patients interrupt treatment, resulting in increased cost-effectiveness and improved patient outcomes.

9.
Clin Psychopharmacol Neurosci ; 20(4): 701-714, 2022 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-36263645

RESUMO

Objective: Moderate and severe behavioral and psychological symptoms of dementia (BPSD) often need medical treatment to improve symptoms. Agomelatine is a selective melatonergic (MT1/MT2) agonist that has normalizing effects on disturbed circadian rhythms and disrupted sleep-wake cycles. Its activity of 5HT-2C receptor antagonism is associated with lessening depression and anxiety and increasing slow-wave sleep. Based on past clinical records and current findings it suggests that agomelatine can improve BPSD for patients. This retrospective cohort study was designed to compare the BPSD before and after using agomelatine. Methods: Records of dementia cases who had ever received agomelatine treatment for BPSD in a general hospital setting during the past 2.5 years were identified and reviewed. Scores from before and after 3 months of treatment with agomelatine were collected for Neuropsychiatric Inventory (NPI), Brief Psychiatric Rating Scale (BPRS), and Clinical Global Impression (CGI) to compare and analyze the difference of psychological and behavioral symptoms pre- and post-agomelatine used. Results: Records of 144 cases of dementia with BPSD who had ever used agomelatine from January 2015 to June 2017 were collected. All of the 112 cases had BPRS and CGI scores, of which 75 cases had additional NPI scores. Among these 112 cases, the BPRS and CGI scores were significantly improved in all types of dementia. NPI scores indicated that the use of agomelatine alleviated obvious symptoms and decreased overall distress, especially in the depression/poor mood, anxiety, and sleep/night behavior. Conclusion: It is consistent with an effective result of agomelatine in improving BPSD.

10.
Hum Reprod ; 37(10): 2320-2333, 2022 09 30.
Artigo em Inglês | MEDLINE | ID: mdl-35960174

RESUMO

STUDY QUESTION: Is a mechanical hand-held device for removing a single-rod subdermal contraceptive implant safe for implant users? SUMMARY ANSWER: In terms of safety, the device is non-inferior to the standard technique for implant removal. WHAT IS KNOWN ALREADY: An easy-to-use device for removing a subdermal contraceptive implant may be helpful in settings where skilled providers are in short supply. Prior to this study, the only report on the world's first hand-held, mechanical device with build-in incisor was a Swedish study using earlier versions of the product. STUDY DESIGN, SIZE, DURATION: From December 2019 to November 2020, we conducted a three-arm, open-label non-inferiority randomized trial involving 225 Ugandan women to assess safety (primary outcome) and measure implant removal efficacy (secondary outcomes) of a newly developed, hand-held device, compared to the standard removal technique. PARTICIPANTS/MATERIALS, SETTING, METHODS: We randomized participants desiring removal of their one-rod contraceptive implant in a 1:1:1 ratio: standard technique/lidocaine injection, new device/lidocaine patch or new device/lidocaine injection. For primary safety endpoints, we examined removal complications and grouped them according to severity. For secondary endpoints on efficacy, we defined three device outcomes: intact implant removed without additional tools (primary), implant removed allowing implant breakage, but without tools (secondary) and implant removed allowing implant breakage and non-scalpel tools (tertiary). We assessed provider feedback on the device and used chi-square tests for all comparisons. MAIN RESULTS AND THE ROLE OF CHANCE: We recruited 225 participants and randomly assigned (n = 75) to each group. For safety, no primary complications occurred in any treatment group, while only one secondary complication occurred in each treatment group (1%). Primary efficacy was 100% (standard technique), 85% (new device/lidocaine patch) and 73% (new device/lidocaine injection) (P < 0.0001). Secondary efficacy was 100% (standard technique), 92% (new device/lidocaine patch) and 79% (new device/lidocaine injection) (P < 0.0001). Tertiary efficacy was 100% (standard technique), 96% (new device/lidocaine patch) and 91% (new device/lidocaine injection) (P = 0.017). Unsuccessful removals with the new device did not hinder subsequent implant extractions with standard back-up tools. In over 90% of the 150 device procedures, providers agreed or strongly agreed that the product is an acceptable alternative to standard removal technique. LIMITATIONS, REASONS FOR CAUTION: We tested a new removal device in the hands of Ugandan nurses who were adept at standard removal techniques; our estimates of removal efficacy may not apply to lower-level providers who arguably may be the prime beneficiaries of this technology. WIDER IMPLICATIONS OF THE FINDINGS: The study was conducted in a region of the world where the new device could be used to expand access to implant removal services. Intended beneficiaries of the new product are implant users who cannot easily find skilled providers for traditional scalpel-dependent removals and/or users who are intimidated by scalpel procedures, and lower-level providers who can be trained to help deliver services to meet a growing demand. The new device is a safe, acceptable alternative; efficacy was high, but not on par with standard technique. STUDY FUNDING/COMPETING INTEREST(S): Funding for this study was provided by the RemovAid AS of Norway with grants from Research Council of Norway (GLOBVAC number 228319), Bill & Melinda Gates Foundation (grant INV-007571) and SkatteFUNN. M.B. is founder and former CEO of RemovAid AS, Norway. M.B. holds contraceptive rod remover patents (2012 1307156.8 and 2015), pre-removal test (filed) and shares in RemovAid AS. All of the remaining authors' institutions received payments in the form of contracts to help conduct the study; the funds for these contracts emanated from RemovAid AS. TRIAL REGISTRATION NUMBER: NCT04120337. TRIAL REGISTRATION DATE: 9 October 2019. DATE OF FIRST PATIENT'S ENROLMENT: 23 December 2019.


Assuntos
Anticoncepcionais Femininos , Levanogestrel , Feminino , Humanos , Lidocaína , Noruega
11.
EClinicalMedicine ; 51: 101554, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35865736

RESUMO

Background: The most widely used copper intrauterine device (IUD) in the world (the TCu380A), and the only product available in many countries, causes side effects and early removals for many users. These problems are exacerbated in nulliparous women, who have smaller uterine cavities compared to parous women. We compared first-year continuation rates and reasons/probabilities for early removal of the TCu380A versus a smaller Belgian copper IUD among nulliparous users. Methods: This 12-month interim report is derived from a pre-planned interim analysis of a sub population and focused on key secondary comparative endpoints. In this participant-blinded trial at 16 centres in the USA, we randomised participants aged 17-40 in a 4:1 ratio to the NT380-Mini or the TCu380A. In the first year, participants had follow-up visits at 6-weeks and 3, 6, and 12-months, and a phone contact at 9 months; we documented continued use, expulsions, and reasons for removal. Among participants with successful IUD placement, we compared probabilities of IUD continuation and specific reasons for discontinuation using log-rank tests. This trial is registered with ClinicalTrials.gov number NCT03124160 and is closed to recruitment. Findings: Between June 1, 2017, and February 25, 2019, we assigned 927 nulliparous women to either the NT380-Mini (n = 744) or the TCu380A (n = 183); the analysis population was 732 (NT380-Mini) and 176 (TCu380A). Participants using the NT380-Mini, compared to the TCu380A, had higher 12-month continuation rates (78·7% [95% CI: 72·9-84·5%] vs. 70·2% [95% CI: 59·7-80·7], p = 0·014), lower rates of removal for bleeding and/or pain (8·1% vs. 16·2%, p = 0·003) and lower IUD expulsion rates (4·8% vs. 8·9%, p = 0·023), respectively. Interpretation: The NT380-Mini offers important benefits for a nulliparous population compared to the TCu380A in the first twelve months, when pivotal experiences typically occur. Higher continuation rates with the NT380-Mini may avert disruptions in contraceptive use and help users avoid unintended pregnancy. Funding: Bill & Melinda Gates Foundation, Eunice Kennedy Shriver National Institute of Child Health and Human Development, and Mona Lisa, N.V. (Belgium).

12.
Sleep Med ; 96: 87-92, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35613539

RESUMO

OBJECTIVE/BACKGROUND: Expiratory positive airway pressure (EPAP) has been a treatment option for patients with obstructive sleep apnea (OSA). ULTepap is a new FDA-cleared EPAP device that seals the nares with a nasal pillow interface. Comparisons of expiratory pressures generated by ULTepap and other EPAP devices like Provent, Bongo Rx, and Theravent are not available. We aimed to compare the backpressures created by these devices in an in vitro laboratory bench setting. METHODS: A test rig was designed and fabricated to test the expiratory pressures generated by ULTepap, Provent, Bongo Rx, and Theravent. Airflow was generated by a linear actuator-driven piston in a syringe, and a range of flow rates was provided by varying the voltage input to the actuator. The resulting expiratory and inspiratory pressures were measured and resistances were calculated. RESULTS: The backpressures generated by ULTepap and Provent were comparable at all flow rates. For flow rates at 99/142/212 ml/s, the expiratory pressures were 3.5/7.5/13.8 cmH2O for ULTepap and 4.5/8.5/14.5 cmH2O for Provent. Bongo Rx and Theravent devices produced substantially lower backpressures compared to ULTepap devices (0.8/1.8/3.5 cmH2O for Bongo Rx and 0.9/2.2/5.3 cmH2O for Theravent at flow rates of 99/142/212 ml/s). All four devices presented very low inspiratory flow resistance, with all generating 0.5 cmH2O or less at all flow rates. CONCLUSION: Not all FDA-cleared EPAP devices produce similar expiratory pressure profiles. ULTepap generated backpressures closest to that of Provent. Clinical trials comparing the efficacy, tolerance, and adherence of these EPAP devices in patients with OSA are warranted.


Assuntos
Apneia Obstrutiva do Sono , Humanos , Cavidade Nasal , Respiração com Pressão Positiva , Apneia Obstrutiva do Sono/terapia
13.
Am J Reprod Immunol ; 88(2): e13542, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35394678

RESUMO

PROBLEM: Data on the effects of contraceptives on female genital tract (FGT) immune mediators are inconsistent, possibly in part due to pre-existing conditions that influence immune mediator changes in response to contraceptive initiation. METHODS: This study included 161 South African women randomised to injectable depot medroxyprogesterone acetate (DMPA-IM), copper intrauterine device (IUD), or levonorgestrel (LNG) implant in the Evidence for Contraceptive Options and HIV Outcomes (ECHO) trial. We measured thirteen cytokines and antimicrobial peptides previously associated with HIV acquisition in vaginal swabs using Luminex and ELISA, before, and at 1 and 3 months after contraceptive initiation. Women were grouped according to an overall baseline inflammatory profile. We evaluated modification of the relationships between contraceptives and immune mediators by baseline inflammation, demographic, and clinical factors. RESULTS: Overall, LNG implant and copper IUD initiation were associated with increases in inflammatory cytokines, while no changes were observed following DMPA-IM initiation. However, when stratifying by baseline inflammatory profile, women with low baseline inflammation in all groups experienced significant increases in inflammatory cytokines, while those with a high baseline inflammatory profile experienced no change or decreases in inflammatory cytokines. CONCLUSION: We conclude that pre-contraceptive initiation immune profile modifies the effect of contraceptives on the FGT innate immune response.


Assuntos
Anticoncepcionais Femininos , Infecções por HIV , Anticoncepcionais Femininos/efeitos adversos , Anticoncepcionais Femininos/farmacologia , Citocinas , Feminino , Genitália , Infecções por HIV/epidemiologia , Humanos , Imunidade Inata , Inflamação , Dispositivos Intrauterinos de Cobre/efeitos adversos , Levanogestrel/efeitos adversos , Levanogestrel/farmacologia , Acetato de Medroxiprogesterona/efeitos adversos , Acetato de Medroxiprogesterona/farmacologia
14.
J Alzheimers Dis ; 86(2): 877-890, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35147533

RESUMO

BACKGROUND: The earlier detection of dementia is needed as cases increase yearly in the aging populations of Taiwan and the world. In recent years, the global internet usage rate has gradually increased among older people. To expand dementia screening and provide timely medical intervention, a simple self-administrated assessment tool to assist in easily screening for dementia is needed. OBJECTIVE: The two-part goal of this pilot study was, first, to develop a Game-Based Cognitive Assessment (GBCA) tool, and then, to evaluate its validity at early screening for patients with cognitive impairment. METHOD: The researchers recruited 67 patients with neurocognitive disorders (NCDs) and 57 healthy controls (HCs). Each participant underwent the GBCA and other clinical cognitive assessments (CDR, CASI, and MMSE), and filled out a questionnaire evaluating their experience of using the GBCA. Statistical analyses were used to measure the validity of the GBCA at screening for degenerative dementia. RESULTS: The average GBCA scores of the HC and NCD groups were 87 (SD = 7.9) and 52 (SD = 21.7), respectively. The GBCA correlated well with the CASI (r2 = 0.90, p < 0.001) and with the MMSE (r2 = 0.92, p < 0.001), indicating concurrent validity. The GBCA cut-off of 75/76 corresponded to measurements of sensitivity, specificity, and area under curve of 85.1%, 91.5%, and 0.978, respectively. The positive predictive value was 91.9%, and the negative predictive value was 84.4%. The results of the user-experience questionnaire for the HC and NCD groups were good and acceptable, respectively. CONCLUSION: The GBCA is an effective and acceptable tool for screening for degenerative dementia.


Assuntos
Disfunção Cognitiva , Demência , Idoso , Cognição , Disfunção Cognitiva/diagnóstico , Demência/diagnóstico , Humanos , Programas de Rastreamento/métodos , Testes Neuropsicológicos , Projetos Piloto , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
15.
PLoS One ; 16(10): e0258040, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34634070

RESUMO

Many wearables allow physiological data acquisition in sleep and enable clinicians to assess sleep outside of sleep labs. Belun Sleep Platform (BSP) is a novel neural network-based home sleep apnea testing system utilizing a wearable ring device to detect obstructive sleep apnea (OSA). The objective of the study is to assess the performance of BSP for the evaluation of OSA. Subjects who take heart rate-affecting medications and those with non-arrhythmic comorbidities were included in this cohort. Polysomnography (PSG) studies were performed simultaneously with the Belun Ring in individuals who were referred to the sleep lab for an overnight sleep study. The sleep studies were manually scored using the American Academy of Sleep Medicine Scoring Manual (version 2.4) with 4% desaturation hypopnea criteria. A total of 78 subjects were recruited. Of these, 45% had AHI < 5; 18% had AHI 5-15; 19% had AHI 15-30; 18% had AHI ≥ 30. The Belun apnea-hypopnea index (bAHI) correlated well with the PSG-AHI (r = 0.888, P < 0.001). The Belun total sleep time (bTST) and PSG-TST had a high correlation coefficient (r = 0.967, P < 0.001). The accuracy, sensitivity, specificity in categorizing AHI ≥ 15 were 0.808 [95% CI, 0.703-0.888], 0.931 [95% CI, 0.772-0.992], and 0.735 [95% CI, 0.589-0.850], respectively. The use of beta-blocker/calcium-receptor antagonist and the presence of comorbidities did not negatively affect the sensitivity and specificity of BSP in predicting OSA. A diagnostic algorithm combining STOP-Bang cutoff of 5 and bAHI cutoff of 15 events/h demonstrated an accuracy, sensitivity, specificity of 0.938 [95% CI, 0.828-0.987], 0.944 [95% CI, 0.727-0.999], and 0.933 [95% CI, 0.779-0.992], respectively, for the diagnosis of moderate to severe OSA. BSP is a promising testing tool for OSA assessment and can potentially be incorporated into clinical practices for the identification of OSA. Trial registration: ClinicalTrial.org NCT03997916 https://clinicaltrials.gov/ct2/show/NCT03997916?term=belun+ring&draw=2&rank=1.


Assuntos
Apneia Obstrutiva do Sono/diagnóstico , Dispositivos Eletrônicos Vestíveis , Adulto , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Distribuição Aleatória , Sensibilidade e Especificidade , Inquéritos e Questionários
16.
J Infect Dis ; 224(1): 137-140, 2021 07 02.
Artigo em Inglês | MEDLINE | ID: mdl-33179029

RESUMO

We conducted a prospective study of 13 heterosexual couples to understand the impact of recent condomless vaginal sex on vaginal immune marker measurement and potential exposure misclassification due to the presence of semen. All immune markers were detectable in semen and concentrations of vaginal immune markers varied by sex recency.


Assuntos
Infecções Sexualmente Transmissíveis/imunologia , Biomarcadores , Feminino , Humanos , Imunidade Inata , Masculino , Estudos Prospectivos , Sêmen/imunologia , Infecções Sexualmente Transmissíveis/etiologia , Vagina/imunologia
17.
PLoS Med ; 17(5): e1003110, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32442189

RESUMO

BACKGROUND: Women living with HIV (WLHIV) have lower rates of contraceptive use than noninfected peers, yet concerns regarding contraceptive efficacy and interaction with antiretroviral therapy (ART) complicate counseling. Hormonal contraceptives may increase genital tract HIV viral load (gVL) and sexual transmission risk to male partners. We compared gVL, plasma VL (pVL), and intrauterine contraceptive (IUC) continuation between the levonorgestrel intrauterine system (LNG-IUS) and copper intrauterine device (C-IUD) in Cape Town, South Africa. METHODS AND FINDINGS: In this double-masked, randomized controlled noninferiority trial, eligible WLHIV were ages 18-40, not pregnant or desiring pregnancy within 30 months, screened and treated (as indicated) for reproductive tract infections (RTIs) within 1 month of enrollment, and virologically suppressed using ART or above treatment threshold at enrollment (non-ART). Between October 2013, and December 2016, we randomized consenting women within ART groups, using 1:1 permuted block randomization stratified by ART use, age (18-23, 24-31, 32-40), and recent injectable progestin contraceptive (IPC) exposure, and provided the allocated IUC. At all visits, participants provided specimens for gVL (primary outcome), pVL, RTI, and pregnancy testing. We assessed gVL and pVL across 6 and 24 months controlling for enrollment measures, ART group, age, and RTI using generalized estimating equation and generalized linear models (non-ART group pVL and hemoglobin) in as-treated analyses. We measured IUC discontinuation rates with Kaplan-Meier estimates and Cox proportional hazards models. We enrolled 71 non-ART (36 LNG-IUS, 31 C-IUD; 2 declined and 2 were ineligible) and 134 ART-using (65 LNG-IUS, 67 C-IUD; 1 declined and 1 could not complete IUC insertion) women. Participant median age was 31 years, and 95% had 1 or more prior pregnancies. Proportions of women with detectable gVL were not significantly different comparing LNG-IUS to C-IUD across 6 (adjusted odds ratio [AOR]: 0.78, 95% confidence interval [CI] 0.44-1.38, p = 0.39) and 24 months (AOR: 1.03, 95% CI: 0.68-1.57, p = 0.88). Among ART users, proportions with detectable pVL were not significantly different at 6 (AOR = 0.83, 95% CI 0.37-1.86, p = 0.65) and 24 months (AOR = 0.94, 95% CI 0.49-1.81, p = 0.85), whereas among non-ART women, mean pVL was not significantly different at 6 months (-0.10 log10 copies/mL, 95% CI -0.29 to 0.10, p = 0.50) between LNG-IUS and C-IUD users. IUC continuation was 78% overall; C-IUD users experienced significantly higher expulsion (8% versus 1%, p = 0.02) and elective discontinuation (adjusted hazard ratio: 8.75, 95% CI 3.08-24.8, p < 0.001) rates. Sensitivity analysis adjusted for differential IUC discontinuation found similar gVL results. There were 39 serious adverse events (SAEs); SAEs believed to be directly related to IUC use (n = 7) comprised 3 pelvic inflammatory disease (PID) cases and 4 pregnancies with IUC in place with no discernible trend by IUC arm. Mean hemoglobin change was significantly higher among LNG-IUS users across 6 (0.57 g/dL, 95% CI 0.24-0.90; p < 0.001) and 24 months (0.71 g/dL, 95% CI 0.47-0.95; p < 0.001). Limitations included not achieving non-ART group sample size following change in ART treatment guidelines and truncated 24 months' outcome data, as 17 women were not yet eligible for their 24-month visit at study closure. Also, a change in VL assay during the study may have caused some discrepancy in VL values because of different limits of detection. CONCLUSIONS: In this study, we found that the LNG-IUS did not increase gVL or pVL and had low levels of contraceptive failure and associated PID compared with the C-IUD among WLHIV. LNG-IUS users were significantly more likely to continue IUC use and had higher hemoglobin levels over time. The LNG-IUS appears to be a safe contraceptive with regard to HIV disease and may be a highly acceptable option for WLHIV. TRIAL REGISTRATION: ClinicalTrials.gov NCT01721798.


Assuntos
Anticoncepcionais Femininos/efeitos adversos , Infecções por HIV , Dispositivos Intrauterinos de Cobre/efeitos adversos , Levanogestrel/efeitos adversos , Adolescente , Adulto , Anticoncepcionais Femininos/uso terapêutico , Feminino , Infecções por HIV/tratamento farmacológico , Infecções por HIV/etiologia , Humanos , Levanogestrel/uso terapêutico , Masculino , África do Sul , Resultado do Tratamento , Adulto Jovem
18.
J Acquir Immune Defic Syndr ; 84(1): 85-91, 2020 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-31985699

RESUMO

BACKGROUND: We previously reported association of increased cervical RANTES and decreased secretory leukocyte protease inhibitor (SLPI) with higher risk of HIV acquisition in reproductive-age women. We now examine the interaction of concomitantly altered systemic and cervical immunity on such risk. METHODS: We measured immune biomarkers in 4390 cervical and 2390 paired serum specimens at quarterly visits in 218 HIV seroconverters and 784 seronegative women. We assessed proinflammatory (IL-1ß, IL-6, IL-8, MIP-3α, and RANTES), anti-inflammatory (IL-1RA and SLPI), vascular activation (vascular endothelial growth factor and Intercellular Adhesion Molecule-1) and defensin (BD2) cervical biomarkers and systemic (peripheral blood) C reactive protein (CRP), IL-6, IL-7, and sCD14 as indicators of immune dysregulation. Biomarker levels were Box-Cox transformed and odds ratios for HIV acquisition calculated based on top quartile or higher/lower than median levels for all HIV-negative visits. RESULTS: Subsequent HIV acquisition was associated with 5 of 14 individual biomarkers: low systemic CRP [odds ratio (OR) = 1.49, 1.21-1.83] and IL-6 (OR = 1.23, 1.00-1.51), high cervical BD-2 (OR = 1.33, 1.11-1.58) and RANTES (OR = 1.20, 1.01-1.43), and low cervical IL-1RA (OR = 0.65, 0.48-0.86). Low systemic CRP concomitant with altered cervical immunity, especially high BD2, conveyed highest HIV risk (1.63, 1.29-2.05). Additional markers of increased risk emerged when low systemic CRP coincided with: low systemic IL-6 and IL-7 (OR = 1.53, 1.18-1.97); high cervical IL-8 and MIP-3α (OR = 1.40, 1.07-1.83); high cervical IL-1ß and IL-6 (OR = 1.43, 1.09-1.86); or low cervical SLPI (OR = 1.36, 1.08-1.71). CONCLUSIONS: Changes in both peripheral and mucosal immunity may precede and predispose women to HIV infection. Suppressed systemic immunity (ie, low CRP) alone or in combination with imbalanced cervical innate immunity (high proinflammatory and low anti-inflammatory mediators) indicated increased vulnerability to infection. Understanding these combined effects on HIV susceptibility is essential to preventing new infections.


Assuntos
Infecções por HIV/imunologia , Imunidade Inata , Imunidade nas Mucosas , Adolescente , Adulto , Biomarcadores/sangue , Biomarcadores/metabolismo , Colo do Útero/imunologia , Colo do Útero/metabolismo , Feminino , Humanos , Estudos Prospectivos , Fatores de Risco , Uganda , Adulto Jovem , Zimbábue
19.
PLoS One ; 15(1): e0224359, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31914129

RESUMO

Sexually transmitted infections (STIs) and vaginal dysbiosis (disturbed resident microbiota presenting with abnormal Nugent score or candidiasis) have been associated with mucosal inflammation and risk of HIV-1 infection, cancer and poor reproductive outcomes. To date, the temporal relationships between aberrant cervical innate immunity and the clinical onset of microbial disturbance have not been studied in a large population of reproductive age women. We examined data from a longitudinal cohort of 934 Ugandan and Zimbabwean women contributing 3,274 HIV-negative visits who had complete laboratory, clinical and demographic data. Among those, 207 women later acquired HIV, and 584 women were intermittently diagnosed with C. trachomatis (CT), N. gonorrhoeae (NG), genital herpes (HSV-2), T. vaginalis (TV), candidiasis, and abnormal intermediate (4-6) or high (7-10) Nugent score, i.e. bacterial vaginosis (BV). Immune biomarker concentrations in cervical swabs were analyzed by generalized linear and mixed effect models adjusting for site, age, hormonal contraceptive use (HC), pregnancy, breastfeeding, genital practices, unprotected sex and overlapping infections. High likelihood ratios (1.5-4.9) denoted the values of cervical immune biomarkers to predict onset of abnormal Nugent score and candidiasis at the next visits. When controlling for covariates, higher levels of ß-defensin-2 were antecedent to BV, CT and HSV-2, lower anti-inflammatory ratio IL-1RA:IL-1ß-to intermediate Nugent scores and candida, lower levels of the serine protease inhibitor SLPI-to candida, lower levels of the adhesion molecule ICAM-1 -to TV, and lower levels of the oxidative stress mitigator and endothelial activation marker VEGF-to NG. Changes in innate immunity following onset of dysbiosis and infections were dependent on HC use when controlling for all other covariates. In conclusion, imminent female genital tract dysbiosis or infection can be predicted by distinct patterns of innate immunity. Future research should characterize biotic and abiotic determinants of this pre-existing innate immunity state.


Assuntos
Disbiose/imunologia , Imunidade Inata/genética , Infecções Sexualmente Transmissíveis/imunologia , Vaginose Bacteriana/imunologia , Adolescente , Adulto , Biomarcadores/metabolismo , Colo do Útero/imunologia , Colo do Útero/microbiologia , Colo do Útero/patologia , Disbiose/epidemiologia , Disbiose/microbiologia , Feminino , Infecções por HIV/epidemiologia , Infecções por HIV/imunologia , Infecções por HIV/virologia , Humanos , Molécula 1 de Adesão Intercelular/imunologia , Molécula 1 de Adesão Intercelular/metabolismo , Proteína Antagonista do Receptor de Interleucina 1/imunologia , Proteína Antagonista do Receptor de Interleucina 1/metabolismo , Interleucina-1beta/imunologia , Interleucina-1beta/metabolismo , Estresse Oxidativo/imunologia , Gravidez , Infecções do Sistema Genital/epidemiologia , Infecções do Sistema Genital/imunologia , Inibidor Secretado de Peptidases Leucocitárias/imunologia , Inibidor Secretado de Peptidases Leucocitárias/metabolismo , Infecções Sexualmente Transmissíveis/epidemiologia , Infecções Sexualmente Transmissíveis/microbiologia , Uganda/epidemiologia , Vagina/imunologia , Vagina/microbiologia , Vaginose Bacteriana/epidemiologia , Vaginose Bacteriana/microbiologia , Fator A de Crescimento do Endotélio Vascular/imunologia , Fator A de Crescimento do Endotélio Vascular/metabolismo , Zimbábue/epidemiologia
20.
AIDS Res Hum Retroviruses ; 34(10): 889-899, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-30047279

RESUMO

Hormonal contraception (HC), particularly injectable depot-medroxyprogesterone acetate (DMPA), has been associated with increased HIV acquisition and higher levels of cervical regulated upon activation, normal T-cell expressed, and secreted (RANTES), also associated with HIV seroconversion. Longitudinal changes in cervical immunity associated with DMPA and combined oral contraceptives (COCs) have not been studied. Cervical samples from 216 HIV seroconverters in Uganda and Zimbabwe with matched samples from 727 HIV-uninfected controls were collected at two quarterly visits before (t - 2, t - 1), at (t0), and two visits following (t + 1, t + 2) HIV seroconversion and corresponding visits for HIV-negative controls. We measured 10 biomarkers of inflammation and immunity and used generalized linear models to estimate and compare biomarker levels across HIV status, contraceptive, and pregnancy groups. Biomarkers remained relatively stable across visits for controls, while in HIV-infected women cervical immunity started to change before seroconversion with RANTES and BD-2 increased and secretory leukocyte protease inhibitor (SLPI) decreased at t - 1 and continued to change at t0 with ICAM-1 up and IL-8 down and with more biomarkers after seroconversion (IL-1ß, IL-6, MIP-3α, VEGF, and IL-1RA down and IL-1RA:IL-1ß ratio up). In multivariable analyses, seroconverters had higher BD-2 at t - 1, higher RANTES and lower SLPI from t - 1 through t + 2, and lower IL-8 and IL-1RA at and/or after seroconversion compared to nonseroconverters. Compared to non-HC users, DMPA users had higher RANTES at all visits and lower BD-2 at t - 2 through t0, while COC users and pregnant women had higher IL-8 and SLPI at all visits; COC users also had lower BD-2 preseroconversion; pregnant women had lower RANTES at t0 - t + 2. Longitudinal patterns of cervical immunity differ between HIV seroconverters and HIV-negative women; seroconverters demonstrate increased RANTES and decreased SLPI starting before and continuing postseroconversion. Furthermore, these patterns are differentially regulated by DMPA, COC, and pregnancy.


Assuntos
Colo do Útero/imunologia , Anticoncepcionais Orais Hormonais/imunologia , Infecções por HIV/imunologia , Mediadores da Inflamação/metabolismo , Adolescente , Adulto , Biomarcadores/metabolismo , Colo do Útero/metabolismo , Anticoncepcionais Orais Combinados/imunologia , Anticoncepcionais Orais Hormonais/administração & dosagem , Feminino , Infecções por HIV/epidemiologia , Infecções por HIV/metabolismo , Humanos , Estudos Longitudinais , Acetato de Medroxiprogesterona/imunologia , Gravidez , Soroconversão , Uganda/epidemiologia , Esfregaço Vaginal , Adulto Jovem , Zimbábue/epidemiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...