RESUMO
ABSTRACT Purpose: Ureteroplasty using buccal or lingual mucosa graft Is feasible for complex proximal ureteral stricture (1, 2). Ileal ureter replacement is considered as the last resort for ureteral reconstruction. Totally intracorporeal robot-assisted ileal ureter replacement can be performed safely and effectively (3). In China, the KangDuo Surgical Robot 2000 Plus (KD-SR-2000 Plus) has been developed featuring two surgeon consoles and five robotic arms. This study aims to share our experience with totally intracorporeal robot-assisted bilateral ileal ureter replacement using KD-SR-2000 Plus. Materials and Methods: A 59-year-old female patient underwent a complete intracorporeal robot-assisted bilateral ileal ureter replacement for the treatment of ureteral strictures using KD-SR-2000 Plus. The surgical procedure involved dissecting the proximal ends of the bilateral ureteral strictures, harvesting the ileal ureter, restoring intestinal continuity, and performing an anastomosis between the ileum and the ureteral end as well as the bladder. The data were prospectively collected and analyzed. Results: The surgery was successfully completed with single docking without open conversion. The length of the harvested ileal ureter was 25 cm. The docking time, operation time and console time were 3.4 min., 271 min and 231 min respectively. The estimated blood loss was 50 mL. The postoperative hospitalization was 6 days. No perioperative complications occurred. Conclusions: It is technically feasible to perform totally intracorporeal robot-assisted bilateral ileal ureter replacement for the treatment of ureteral strictures using KD-SR-2000 Plus. A longer follow-up and a larger sample size are required to evaluate its safety and effectiveness.
RESUMO
ABSTRACT Introduction: We aim to compare the safety and effectiveness of the KangDuo (KD)-Surgical Robot-01 (KD-SR-01) system and the da Vinci (DV) system for robot-assisted radical nephroureterectomy (RARNU). Materials and Methods: This multicenter prospective randomized controlled trial was conducted between March 2022 and September 2023. Group 1 included 29 patients undergoing KD-RARNU. Group 2 included 29 patients undergoing DV-RARNU. Patient demographic and clinical characteristics, perioperative data, and follow-up outcomes were collected prospectively and compared between the two groups. Results: There were no significant differences in patient baseline demographic and preoperative characteristics between the two groups. The success rates in both groups were 100% without conversion to open or laparoscopic surgery or positive surgical margins. No significant difference was observed in docking time [242 (120-951) s vs 253 (62-498) s, P = 0.780], console time [137 (55-290) min vs 105 (62-220) min, P = 0.114], operative time [207 (121-460) min vs 185 (96-305) min, P = 0.091], EBL [50 (10-600) mL vs 50 (10-700) mL, P = 0.507], National Aeronautics and Space Administration Task Load Index scores, and postoperative serum creatinine levels between the two groups. None of the patients showed evidence of distant metastasis, local recurrence, or equipment-related adverse events during the four-week follow-up. One (3.4%) patient in Group 2 experienced postoperative enterovaginal and enterovesical fistulas (Clavien-Dindo grade III). Conclusions: The KD-SR-01 system is safe and effective for RARNU compared to the DV Si or Xi system. Further randomized controlled studies with larger sample sizes and longer durations are required.
RESUMO
PURPOSE: Ureteroplasty using buccal or lingual mucosa graft Is feasible for complex proximal ureteral stricture (1, 2). Ileal ureter replacement is considered as the last resort for ureteral reconstruction. Totally intracorporeal robot-assisted ileal ureter replacement can be performed safely and effectively (3). In China, the KangDuo Surgical Robot 2000 Plus (KD-SR-2000 Plus) has been developed featuring two surgeon consoles and five robotic arms. This study aims to share our experience with totally intracorporeal robot-assisted bilateral ileal ureter replacement using KD-SR-2000 Plus. MATERIALS AND METHODS: A 59-year-old female patient underwent a complete intracorporeal robot-assisted bilateral ileal ureter replacement for the treatment of ureteral strictures using KD-SR-2000 Plus. The surgical procedure involved dissecting the proximal ends of the bilateral ureteral strictures, harvesting the ileal ureter, restoring intestinal continuity, and performing an anastomosis between the ileum and the ureteral end as well as the bladder. The data were prospectively collected and analyzed. RESULTS: The surgery was successfully completed with single docking without open conversion. The length of the harvested ileal ureter was 25 cm. The docking time, operation time and console time were 3.4 min., 271 min and 231 min respectively. The estimated blood loss was 50 mL. The postoperative hospitalization was 6 days. No perioperative complications occurred. CONCLUSIONS: It is technically feasible to perform totally intracorporeal robot-assisted bilateral ileal ureter replacement for the treatment of ureteral strictures using KD-SR-2000 Plus. A longer follow-up and a larger sample size are required to evaluate its safety and effectiveness.
Assuntos
Íleo , Procedimentos Cirúrgicos Robóticos , Ureter , Obstrução Ureteral , Humanos , Feminino , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Robóticos/métodos , Ureter/cirurgia , Íleo/cirurgia , Resultado do Tratamento , Obstrução Ureteral/cirurgia , Constrição Patológica/cirurgia , Duração da Cirurgia , Anastomose Cirúrgica/métodos , Procedimentos Cirúrgicos Urológicos/métodosRESUMO
INTRODUCTION: We aim to compare the safety and effectiveness of the KangDuo (KD)-Surgical Robot-01 (KD-SR-01) system and the da Vinci (DV) system for robot-assisted radical nephroureterectomy (RARNU). MATERIALS AND METHODS: This multicenter prospective randomized controlled trial was conducted between March 2022 and September 2023. Group 1 included 29 patients undergoing KD-RARNU. Group 2 included 29 patients undergoing DV-RARNU. Patient demographic and clinical characteristics, perioperative data, and follow-up outcomes were collected prospectively and compared between the two groups. RESULTS: There were no significant differences in patient baseline demographic and preoperative characteristics between the two groups. The success rates in both groups were 100% without conversion to open or laparoscopic surgery or positive surgical margins. No significant difference was observed in docking time [242 (120-951) s vs 253 (62-498) s, P = 0.780], console time [137 (55-290) min vs 105 (62-220) min, P = 0.114], operative time [207 (121-460) min vs 185 (96-305) min, P = 0.091], EBL [50 (10-600) mL vs 50 (10-700) mL, P = 0.507], National Aeronautics and Space Administration Task Load Index scores, and postoperative serum creatinine levels between the two groups. None of the patients showed evidence of distant metastasis, local recurrence, or equipment-related adverse events during the four-week follow-up. One (3.4%) patient in Group 2 experienced postoperative enterovaginal and enterovesical fistulas (Clavien-Dindo grade III). CONCLUSIONS: The KD-SR-01 system is safe and effective for RARNU compared to the DV Si or Xi system. Further randomized controlled studies with larger sample sizes and longer durations are required.
Assuntos
Nefroureterectomia , Duração da Cirurgia , Procedimentos Cirúrgicos Robóticos , Humanos , Procedimentos Cirúrgicos Robóticos/métodos , Procedimentos Cirúrgicos Robóticos/instrumentação , Feminino , Masculino , Estudos Prospectivos , Pessoa de Meia-Idade , Nefroureterectomia/métodos , Idoso , Resultado do Tratamento , Neoplasias Renais/cirurgia , Tempo de Internação , Laparoscopia/métodos , Laparoscopia/instrumentação , Reprodutibilidade dos Testes , Complicações Pós-OperatóriasRESUMO
ABSTRACT Purpose Horseshoe kidney (HSK) is the most common renal fusion anomaly, occurring in 0.25% of the population (1). It presents technical obstacles to pyeloplasty for ureteropelvic junction obstruction (UPJO) despite robotic assistance (2, 3). KangDuo-Surgical-Robot-01 (KD-SR-01), an emerging robotic platform in China, has yielded satisfactory outcomes in pyeloplasty (4, 5). We first describe our modified technique of robotic bilateral pyeloplasty for UPJO in HSK using KD-SR-01 system in the Lithotomy Trendelenburg position. Materials and Methods A 36-year-old man with HSK and bilateral UPJO suffered right flank pain due to renal calculi (Figure-1). Repeated double-J stent insertion and ureteroscopy lithotripsy did not relieve his symptoms. A robot-assisted modified bilateral dismembered V-shaped flap pyeloplasty was performed using KD-SR-01 system in the Lithotomy Trendelenburg position. Results Total operative time was 298 minutes with 50 ml estimated blood loss. There was no conversion to laparoscopic or open surgery. A follow-up of 14 months showed relieving symptoms and stable renal function. Cine magnetic resonance urography and computed tomography urography revealed improved hydronephrosis and good drainage. No intraoperative or postoperative complications occurred. Conclusions It is technically feasible to perform a KD-SR-01-assisted modified bilateral dismembered V-shaped flap pyeloplasty in the Lithotomy Trendelenburg position for HSK. This procedure achieves managing UPJO on both sides without redocking the system and provides a wider operative field. In addition, it may be associated with better ergonomics, better cosmetic outcomes, and less possibility of postoperative bowel adhesion. However, further investigation is still warranted to confirm its safety, efficacy, and advantages over traditional procedures.
RESUMO
PURPOSE: Horseshoe kidney (HSK) is the most common renal fusion anomaly, occurring in 0.25% of the population (1). It presents technical obstacles to pyeloplasty for ureteropelvic junction obstruction (UPJO) despite robotic assistance (2, 3). KangDuo-Surgical-Robot-01 (KD-SR-01), an emerging robotic platform in China, has yielded satisfactory outcomes in pyeloplasty (4, 5). We first describe our modified technique of robotic bilateral pyeloplasty for UPJO in HSK using KD-SR-01 system in the Lithotomy Trendelenburg position. MATERIALS AND METHODS: A 36-year-old man with HSK and bilateral UPJO suffered right flank pain due to renal calculi (Figure-1). Repeated double-J stent insertion and ureteroscopy lithotripsy did not relieve his symptoms. A robot-assisted modified bilateral dismembered V-shaped flap pyeloplasty was performed using KD-SR-01 system in the Lithotomy Trendelenburg position. RESULTS: Total operative time was 298 minutes with 50 ml estimated blood loss. There was no conversion to laparoscopic or open surgery. A follow-up of 14 months showed relieving symptoms and stable renal function. Cine magnetic resonance urography and computed tomography urography revealed improved hydronephrosis and good drainage. No intraoperative or postoperative complications occurred. CONCLUSIONS: It is technically feasible to perform a KD-SR-01-assisted modified bilateral dismembered V-shaped flap pyeloplasty in the Lithotomy Trendelenburg position for HSK. This procedure achieves managing UPJO on both sides without redocking the system and provides a wider operative field. In addition, it may be associated with better ergonomics, better cosmetic outcomes, and less possibility of postoperative bowel adhesion. However, further investigation is still warranted to confirm its safety, efficacy, and advantages over traditional procedures.