Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Opt Express ; 21(16): 18872-83, 2013 Aug 12.
Artigo em Inglês | MEDLINE | ID: mdl-23938800

RESUMO

This paper presents a common-path laser planar encoder (CLPE) for displacement measurements in the X- and Y- axes. The CLPE can effectively reduce the environmental disturbance to its lowest level. The experimental results of the CLPE match well with those of HP5529A for both short and long ranges. The CLPE can measure 2D displacement with high resolutions of 0.07 ± 0.021 nm and 0.07 ± 0.023 nm in the X- and Y- axes and also presents high system stabilities of -0.59 ± 0.43 nm/h and -0.63 ± 0.47 nm/h respectively in the X- and Y- axes. The CLPE has promising potential for nanometer resolution and large-range applications.

2.
Opt Express ; 21(11): 13322-32, 2013 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-23736584

RESUMO

This paper presents a heterodyne common-path grating interferometer with Littrow configuration (HCGIL). The HCGIL can effectively overcome environmental disturbance effect and the DC offset and the amplitude variation of the measurement signals. Experimental results match well with the HP5529A results for long-range measurements. Results also show that the estimated measurement resolution is 0.15 ± 0.027 nm. The stability of the HCGIL is -0.41 ± 0.23 nm. Therefore, the HCGIL has potential for subnanometer resolution and long-range applications.