Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Zhongguo Zhen Jiu ; 43(11): 1239-1245, 2023 Sep 01.
Artigo em Inglês, Chinês | MEDLINE | ID: mdl-37986247

RESUMO

OBJECTIVES: To compare the effects of electroacupuncture (EA) with different time intervals on corticospinal excitability of the primary motor cortex (M1) and the upper limb motor function in healthy subjects and observe the after-effect rule of acupuncture. METHODS: Self-comparison before and after intervention design was adopted. Fifteen healthy subjects were included and all of them received three stages of trial observation, namely EA0 group (received one session of EA), EA6h group (received two sessions of EA within 1 day, with an interval of 6 h) and EA48h group (received two sessions of EA within 3 days, with an interval of 48 h). The washout period among stages was 1 week. In each group, the needles were inserted perpendicularly at Hegu (LI 4) on the left side, 23 mm in depth and at a non-acupoint, 0.5 cm nearby to the left side of Hegu (LI 4), separately. Han's acupoint nerve stimulator (HANS-200A) was attached to these two needles, with continuous wave and the frequency of 2 Hz. The stimulation intensity was exerted higher than the exercise threshold (local muscle twitching was visible, and pain was tolerable by healthy subjects, 1-2 mA ). The needles were retained for 30 min. Using the single pulse mode of transcranial magnetic stimulation (TMS) technique, before the first session of EA (T0) and at the moment (T1), in 2 h (T2) and 24 h (T3) after the end of the last session of EA, on the left first dorsal interosseous muscle, the amplitude, latency (LAT), resting motor threshold (rMT) of motor evoked potentials (MEPs) and the completion time of grooved pegboard test (GPT) were detected. Besides, in the EA6h group, TMS was adopted to detect the excitability of M1 (amplitude, LAT and rMT of MEPs) before the last session of EA (T0*). RESULTS: The amplitude of MEPs at T1 and T2 in the EA0 group, at T0* in the EA6h group and at T1, T2 and T3 in the EA48h group was higher when compared with the value at T0 in each group separately (P<0.001). At T1, the amplitude of MEPs in the EA0 group and the EA48h group was higher than that in the EA6h group (P<0.001, P<0.01); at T2, it was higher in the EA0 group when compared with that in the EA6h group (P<0.01); at T3, the amplitude in the EA0 group and the EA6h group was lower than that of the EA48h group (P<0.001). The LAT at T1 was shorter than that at T0 in the three groups (P<0.05), and the changes were not obvious at the rest time points compared with that at T0 (P > 0.05). The GPT completion time of healthy subjects in the EA0 group and the EA48h group at T1, T2 and T3 was reduced in comparison with that at T0 (P<0.001). The completion time at T3 was shorter than that at T0 in the EA6h group (P<0.05); at T2, it was reduced in the EA48h group when compared with that of the EA6h group (P<0.05). There were no significant differences in rMT among the three groups and within each group (P>0.05). CONCLUSIONS: Under physiological conditions, EA has obvious after-effect on corticospinal excitability and upper limb motor function. The short-term interval protocol (6 h) blocks the after-effect of EA to a certain extent, while the long-term interval protocol (48 h) prolongs the after-effect of EA.


Assuntos
Eletroacupuntura , Córtex Motor , Humanos , Córtex Motor/fisiologia , Estimulação Magnética Transcraniana/métodos , Extremidade Superior , Exercício Físico , Músculo Esquelético/fisiologia
2.
Sensors (Basel) ; 22(23)2022 Nov 29.
Artigo em Inglês | MEDLINE | ID: mdl-36502004

RESUMO

A wireless sensor network (WSN) consists of a very large number of sensors which are deployed in the specific area of interest. A sensor is an electronic device equipped with a small processor and has a small-capacity memory. The WSN has the functions of low cost, easy deployment, and random reconfiguration. In this paper, an energy-efficient load balancing tree-based data aggregation scheme (LB-TBDAS) for grid-based WSNs is proposed. In this scheme, the sensing area is partitioned into many cells of a grid and then the sensor node with the maximum residual energy is elected to be the cell head in each cell. Then, the tree-like path is established by using the minimum spanning tree algorithm. In the tree construction, it must meet the three constraints, which are the minimum energy consumption spanning tree, the network depth, and the maximum number of child nodes. In the data transmission process, the cell head is responsible for collecting the sensing data in each cell, and the collected data are transmitted along the tree-like path to the base station (BS). Simulation results show that the total energy consumption of LB-TBDAS is significantly less than that of GB-PEDAP and PEDAP. Compared to GB-PEDAP and PEDAP, the proposed LB-TBDAS extends the network lifetime by more than 100%. The proposed LB-TBDAS can avoid excessive energy consumption of sensor nodes during multi-hop data transmission and can also avoid the hotspot problem of WSNs.


Assuntos
Conservação de Recursos Energéticos , Agregação de Dados , Criança , Humanos , Sistemas Computacionais , Coleta de Dados , Eletrônica
3.
Small ; 16(39): e2002808, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32851802

RESUMO

As stated in the classic Kirchhoff's circuit laws, the total conductance of two parallel channels in an electronic circuit is the sum of the individual conductance. However, in molecular circuits, the quantum interference (QI) between the individual channels may lead to apparent invalidity of Kirchhoff's laws. Such an effect can be very significant in single-molecule circuits consisting of partially overlapped multiple transport channels. Herein, an investigation on how the molecular circuit conductance correlates to the individual channels is conducted in the presence of QI. It is found that the conductance of multi-channel circuit consisting of both constructive and destructive QI is significantly smaller than the addition of individual ones due to the interference between channels. In contrast, the circuit consisting of destructive QI channels exhibits an additive transport. These investigations provide a new cognition of transport mechanism and manipulation of transport in multi-channel molecular circuits.

4.
Nanoscale Horiz ; 5(10): 1420-1429, 2020 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-32856666

RESUMO

Sb nanosheets, also known as antimonene, have received ever-growing consideration as a promising new type of two-dimensional (2D) material due to their many attractive properties. However, how their nonlinear optical (NLO) properties are affected by their nanosheet structure and measurement conditions remains unclear. Herein, we report a successful size-selective production method for Sb nanosheets, which is based on a combination of lithium ion intercalation, solvent exfoliation and size selection centrifugation. This high-yield and size-selective preparation method enables fundamental investigation on the relation of the intrinsic optical properties of Sb nanosheets. Nanosecond Z-scan measurements revealed a unique size-dependent broadband NLO response. When the average size is reduced from 3 micrometers to 50 nanometers, the Sb nanosheets exhibit a clear transition from saturable absorption to reversed saturable absorption. Ultrafast transient absorption spectroscopic investigation indicated that exciton cooling is significantly faster in a small nanosheet than in large ones, revealing that the different exciton relaxation dynamic plays key roles in the distinct size-tunable nonlinear optical response. This work paves new ways towards the mass production and practical application of antimonene.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...