Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
1.
Radiology ; 307(2): e221810, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36692396

RESUMO

Background Preclinical studies have suggested that solid-state MRI markers of cortical bone porosity, morphologic structure, mineralization, and osteoid density are useful measures of bone health. Purpose To explore whether MRI markers of cortical bone porosity, morphologic structure, mineralization, and osteoid density are affected in postmenopausal osteoporosis (OP) and to examine associations between MRI markers and bone mineral density (BMD) in postmenopausal women. Materials and Methods In this single-center study, postmenopausal women were prospectively recruited from January 2019 to October 2020 into two groups: participants with OP who had not undergone treatment, defined as having any dual-energy x-ray absorptiometry (DXA) T-score of -2.5 or less, and age-matched control participants without OP (hereafter, non-OP). Participants underwent MRI in the midtibia, along with DXA in the hip and spine, and peripheral quantitative CT in the midtibia. Specifically, MRI measures of cortical bone porosity (pore water and total water), osteoid density (bound water [BW]), morphologic structure (cortical bone thickness), and mineralization (phosphorous [P] density [31P] and 31P-to-BW concentration ratio) were quantified at 3.0 T. MRI measures were compared between OP and non-OP groups and correlations with BMD were assessed. Results Fifteen participants with OP (mean age, 63 years ± 5 [SD]) and 19 participants without OP (mean age, 65 years ± 6) were evaluated. The OP group had elevated pore water (11.6 mol/L vs 9.5 mol/L; P = .007) and total water densities (21.2 mol/L vs 19.7 mol/L; P = .03), and had lower cortical bone thickness (4.8 mm vs 5.6 mm; P < .001) and 31P density (6.4 mol/L vs 7.5 mol/L; P = .01) than the non-OP group, respectively, although there was no evidence of a difference in BW or 31P-to-BW concentration ratio. Pore and total water densities were inversely associated with DXA and peripheral quantitative CT BMD (P < .001), whereas cortical bone thickness and 31P density were positively associated with DXA and peripheral quantitative CT BMD (P = .01). BW, 31P density, and 31P-to-BW concentration ratio were positively associated with DXA (P < .05), but not with peripheral quantitative CT. Conclusion Solid-state MRI of cortical bone was able to help detect potential impairments in parameters reflecting porosity, morphologic structure, and mineralization in postmenopausal osteoporosis. © RSNA, 2023 Supplemental material is available for this article. See also the editorial by Bae in this issue.


Assuntos
Osteoporose Pós-Menopausa , Feminino , Humanos , Pessoa de Meia-Idade , Idoso , Osteoporose Pós-Menopausa/diagnóstico por imagem , Porosidade , Densidade Óssea , Absorciometria de Fóton , Osso Cortical/diagnóstico por imagem , Água , Imageamento por Ressonância Magnética
2.
Magn Reson Med ; 88(5): 2208-2216, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35877783

RESUMO

PURPOSE: Although many methods have been proposed to quantitatively map the main MRI parameters (e.g., T1 , T2 , C × M0 ), these methods often involve special sequences not readily available on clinical scanners and/or may require long scan times. In contrast, the proposed method can readily run on most scanners, offer flexible tradeoffs between scan time and image quality, and map MRI parameters jointly to ensure spatial alignment. METHODS: The approach is based on the multi-shot spin-echo (SE) EPI sequence. The corresponding signal equation was derived and strategies for solving it were developed. As usual with multi-shot EPI, scan time can readily be traded-off against image quality by adjusting the echo train length. Validation was performed against reference relaxometry methods, in gel phantoms with varying concentrations of gadobutrol and gadoterate meglumine contrast agents. In vivo examples are further presented, from 3 neuroradiology patients. RESULTS: Bland-Altman analysis was performed: for T2 , as compared to 2D SE, bias was 0.29 ms and the 95% limits of agreement ranged from -1.15 to +1.73 ms. For T1 , compared to inversion-recovery SE (and MOLLI), bias was -20.2 ms (and -14.5 ms) and the limits of agreement ranged from -62.4 to +22.0 ms (and -53.8 to +24.9 ms). The mean relative T1 error between the proposed method and each of the 2 reference methods was similar to that of the reference methods among themselves. CONCLUSION: In the constellation of existing relaxometry methods, the proposed method is meant to stand out in terms of its practicality and availability.


Assuntos
Imageamento por Ressonância Magnética , Humanos , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Reprodutibilidade dos Testes
3.
Magn Reson Med ; 88(3): 1229-1243, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35699155

RESUMO

PURPOSE: Cerebral metabolic rate of oxygen (CMRO2 ) is an important biomarker of brain function. Key physiological parameters required to quantify CMRO2 include blood flow rate in the feeding arteries and venous oxygen saturation (SvO2 ) in the draining vein. Here, a pulse sequence, metabolism of oxygen via T2 and interleaved velocity encoding (MOTIVE), was developed to measure both parameters simultaneously and enable CMRO2 quantification in a single pass. METHODS: The MOTIVE sequence interleaves a phase-contrast module between a nonselective saturation and a background-suppressed T2 -prepared EPI readout (BGS-EPI) to measure T2 of blood water protons and cerebral blood flow in 20 s or less. The MOTIVE and standalone BGS-EPI sequences were compared against TRUST ("T2 relaxation under spin tagging") in the brain in healthy subjects (N = 24). Variants of MOTIVE to enhance resolution or shorten scan time were explored. Intrasession and intersession reproducibility studies were performed. RESULTS: MOTIVE experiments yielded an average SvO2 of 61 ± 6% in the superior sagittal sinus of the brain and an average cerebral blood flow of 56 ± 10 ml/min/100 g. The bias in SvO2 of MOTIVE and BGS-EPI to TRUST was +2 ± 4% and +1 ± 3%, respectively. The bias in cerebral blood flow of MOTIVE to Cartesian phase-contrast reference was +1 ± 6 ml/min/100 g. CONCLUSIONS: The MOTIVE sequence is an advance over existing T2 -based oximetric methods. It does not require a control image and simultaneously measures SvO2 and flow velocity. The measurements agree well with TRUST and reference phase-contrast sequences. This noninvasive technique enables CMRO2 quantification in under 20 s and is reproducible for in vivo applications.


Assuntos
Imageamento por Ressonância Magnética , Oxigênio , Encéfalo/diagnóstico por imagem , Encéfalo/metabolismo , Circulação Cerebrovascular , Humanos , Imageamento por Ressonância Magnética/métodos , Oximetria/métodos , Consumo de Oxigênio/fisiologia , Reprodutibilidade dos Testes
4.
Phys Med Biol ; 67(2)2022 01 19.
Artigo em Inglês | MEDLINE | ID: mdl-34891142

RESUMO

Breathing motion can displace internal organs by up to several cm; as such, it is a primary factor limiting image quality in medical imaging. Motion can also complicate matters when trying to fuse images from different modalities, acquired at different locations and/or on different days. Currently available devices for monitoring breathing motion often do so indirectly, by detecting changes in the outline of the torso rather than the internal motion itself, and these devices are often fixed to floors, ceilings or walls, and thus cannot accompany patients from one location to another. We have developed small ultrasound-based sensors, referred to as 'organ configuration motion' (OCM) sensors, that attach to the skin and provide rich motion-sensitive information. In the present work we tested the ability of OCM sensors to enable respiratory gating duringin vivoPET imaging. A motion phantom involving an FDG solution was assembled, and two cancer patients scheduled for a clinical PET/CT exam were recruited for this study. OCM signals were used to help reconstruct phantom andin vivodata into time series of motion-resolved images. As expected, the motion-resolved images captured the underlying motion. In Patient #1, a single large lesion proved to be mostly stationary through the breathing cycle. However, in Patient #2, several small lesions were mobile during breathing, and our proposed new approach captured their breathing-related displacements. In summary, a relatively inexpensive hardware solution was developed here for respiration monitoring. Because the proposed sensors attach to the skin, as opposed to walls or ceilings, they can accompany patients from one procedure to the next, potentially allowing data gathered in different places and at different times to be combined and compared in ways that account for breathing motion.


Assuntos
Imagem Multimodal , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Humanos , Movimento (Física) , Imagens de Fantasmas , Tomografia por Emissão de Pósitrons/métodos
5.
Med Phys ; 48(7): 3614-3622, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33999423

RESUMO

PURPOSE: Medical procedures can be difficult to perform on anatomy that is constantly moving. Respiration displaces internal organs by up to several centimeters with respect to the surface of the body, and patients often have limited ability to hold their breath. Strategies to compensate for motion during diagnostic and therapeutic procedures require reliable information to be available. However, current devices often monitor respiration indirectly, through changes on the outline of the body, and they may be fixed to floors or ceilings, and thus unable to follow a given patient through different locations. Here we show that small ultrasound-based sensors referred to as "organ configuration motion" (OCM) sensors can be fixed to the abdomen and/or chest and provide information-rich, breathing-related signals. METHODS: By design, the proposed sensors are relatively inexpensive. Breathing waveforms were obtained from tissues at varying depths and/or using different sensor placements. Validation was performed against breathing waveforms derived from magnetic resonance imaging (MRI) and optical tracking signals in five and eight volunteers, respectively. RESULTS: Breathing waveforms from different modalities were scaled so they could be directly compared. Differences between waveforms were expressed in the form of a percentage, as compared to the amplitude of a typical breath. Expressed in this manner, for shallow tissues, OCM-derived waveforms on average differed from MRI and optical tracking results by 13.1% and 15.5%, respectively. CONCLUSION: The present results suggest that the proposed sensors provide measurements that properly characterize breathing states. While OCM-based waveforms from shallow tissues proved similar in terms of information content to those derived from MRI or optical tracking, OCM further captured depth-dependent and position-dependent (i.e., chest and abdomen) information. In time, the richer information content of OCM-based waveforms may enable better respiratory gating to be performed, to allow diagnostic and therapeutic equipment to perform at their best.


Assuntos
Movimento , Respiração , Humanos , Imageamento por Ressonância Magnética , Movimento (Física) , Ultrassonografia
6.
Magn Reson Med ; 84(4): 2034-2047, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32307749

RESUMO

PURPOSE: The impact of gradient imperfections on UTE images and UTE image-derived bone water quantification was investigated at 3 T field strength. METHODS: The effects of simple gradient time delays and eddy currents on UTE images, as well as the effects of gradient error corrections, were studied with simulation and phantom experiments. The k-space trajectory was mapped with a 2D sequence with phase encoding on both spatial axes by measuring the phase of the signal in small time increments during ramp-up of the read gradient. In vivo 3D UTE images were reconstructed with and without gradient error compensation to determine the bias in bone water quantification. Finally, imaging was performed on 2 equally configured Siemens TIM Trio systems (Siemens Medical Solutions, Erlangen, Germany) to investigate the impact of such gradient imperfections on inter-scanner measurement bias. RESULTS: Compared to values derived from UTE images with full gradient error compensation, total bone water was found to deviate substantially with no (up to 17%) or partial (delay-only) compensation (up to 10.8%). Bound water, obtained with inversion recovery-prepared UTE, was somewhat less susceptible to gradient errors (up to 2.2% for both correction strategies). Inter-scanner comparison indicated a statistically significant bias between measurements from the 2 MR systems for both total and bound water, which either vanished or was substantially reduced following gradient error correction. CONCLUSION: Gradient imperfections impose spatially dependent artifacts on UTE images, which compromise not only bone water quantification accuracy but also inter-scanner measurement agreement if left uncompensated.


Assuntos
Imageamento por Ressonância Magnética , Água , Alemanha , Imageamento Tridimensional , Imagens de Fantasmas
7.
Magn Reson Med ; 83(6): 2310-2321, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-31755588

RESUMO

PURPOSE: Clinical exams typically involve acquiring many different image contrasts to help discriminate healthy from diseased states. Ideally, 3D quantitative maps of all of the main MR parameters would be obtained for improved tissue characterization. Using data from a 7-min whole-brain multi-pathway multi-echo (MPME) scan, we aimed to synthesize several 3D quantitative maps (T1 and T2 ) and qualitative contrasts (MPRAGE, FLAIR, T1 -weighted, T2 -weighted, and proton density [PD]-weighted). The ability of MPME acquisitions to capture large amounts of information in a relatively short amount of time suggests it may help reduce the duration of neuro MR exams. METHODS: Eight healthy volunteers were imaged at 3.0T using a 3D isotropic (1.2 mm) MPME sequence. Spin-echo, MPRAGE, and FLAIR scans were performed for training and validation. MPME signals were interpreted through neural networks for predictions of different quantitative and qualitative contrasts. Predictions were compared to reference values at voxel and region-of-interest levels. RESULTS: Mean absolute errors (MAEs) for T1 and T2 maps were 216 ms and 11 ms, respectively. In ROIs containing white matter (WM) and thalamus tissues, the mean T1 /T2 predicted values were 899/62 ms and 1139/58 ms, consistent with reference values of 850/66 ms and 1126/58 ms, respectively. For qualitative contrasts, signals were normalized to those of WM, and MAEs for MPRAGE, FLAIR, T1 -weighted, T2 -weighted, and PD-weighted contrasts were 0.14, 0.15, 0.13, 0.16, and 0.05, respectively. CONCLUSIONS: Using an MPME sequence and neural-network contrast translation, whole-brain results were obtained with a variety of quantitative and qualitative contrast in ~6.8 min.


Assuntos
Imageamento por Ressonância Magnética , Substância Branca , Encéfalo/diagnóstico por imagem , Voluntários Saudáveis , Humanos
8.
Magn Reson Med ; 81(3): 1699-1713, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30320945

RESUMO

PURPOSE: Quantitative parameter maps, as opposed to qualitative grayscale images, may represent the future of diagnostic MRI. A new quantitative MRI method is introduced here that requires a single 3D acquisition, allowing good spatial coverage to be achieved in relatively short scan times. METHODS: A multipathway multi-echo sequence was developed, and at least 3 pathways with 2 TEs were needed to generate T1 , T2 , T2* , B1+ , and B0 maps. The method required the central k-space region to be sampled twice, with the same sequence but with 2 very different nominal flip angle settings. Consequently, scan time was only slightly longer than that of a single scan. The multipathway multi-echo data were reconstructed into parameter maps, for phantom as well as brain acquisitions, in 5 healthy volunteers at 3 T. Spatial resolution, matrix size, and FOV were 1.2 × 1.0 × 1.2 mm3 , 160 × 192 × 160, and 19.2 × 19.2 × 19.2 cm3 (whole brain), acquired in 11.5 minutes with minimal acceleration. Validation was performed against T1 , T2 , and T2* maps calculated from gradient-echo and spin-echo data. RESULTS: In Bland-Altman plots, bias and limits of agreement for T1 and T2 results in vivo and in phantom were -2.9/±125.5 ms (T1 in vivo), -4.8/±20.8 ms (T2 in vivo), -1.5/±18.1 ms (T1 in phantom), and -5.3/±7.4 ms (T2 in phantom), for regions of interest including given brain structures or phantom compartments. Due to relatively high noise levels, the current implementation of the approach may prove more useful for region of interest-based as opposed to pixel-based interpretation. CONCLUSIONS: We proposed a novel approach to quantitatively map MR parameters based on a multipathway multi-echo acquisition.


Assuntos
Encéfalo/diagnóstico por imagem , Imagem Ecoplanar , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética , Adulto , Algoritmos , Mapeamento Encefálico , Simulação por Computador , Feminino , Voluntários Saudáveis , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Modelos Estatísticos , Imagens de Fantasmas , Adulto Jovem
9.
Int J Comput Assist Radiol Surg ; 13(12): 1871-1880, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30097956

RESUMO

PURPOSE: Matching points that are derived from features or landmarks in image data is a key step in some medical imaging applications. Since most robust point matching algorithms claim to be able to deal with outliers, users may place high confidence in the matching result and use it without further examination. However, for tasks such as feature-based registration in image-guided neurosurgery, even a few mismatches, in the form of invalid displacement vectors, could cause serious consequences. As a result, having an effective tool by which operators can manually screen all matches for outliers could substantially benefit the outcome of those applications. METHODS: We introduce a novel variogram-based outlier screening method for vectors. The variogram is a powerful geostatistical tool for characterizing the spatial dependence of stochastic processes. Since the spatial correlation of invalid displacement vectors, which are considered as vector outliers, tends to behave differently than normal displacement vectors, they can be efficiently identified on the variogram. RESULTS: We validate the proposed method on 9 sets of clinically acquired ultrasound data. In the experiment, potential outliers are flagged on the variogram by one operator and further evaluated by 8 experienced medical imaging researchers. The matching quality of those potential outliers is approximately 1.5 lower, on a scale from 1 (bad) to 5 (good), than valid displacement vectors. CONCLUSION: The variogram is a simple yet informative tool. While being used extensively in geostatistical analysis, it has not received enough attention in the medical imaging field. We believe there is a good deal of potential for clinically applying the proposed outlier screening method. By way of this paper, we also expect researchers to find variogram useful in other medical applications that involve motion vectors analyses.


Assuntos
Algoritmos , Interpretação de Imagem Assistida por Computador , Procedimentos Neurocirúrgicos/métodos , Cirurgia Assistida por Computador/métodos , Humanos
10.
Magn Reson Med ; 77(3): 1193-1200, 2017 03.
Artigo em Inglês | MEDLINE | ID: mdl-26968318

RESUMO

PURPOSE: Dual-pathway sequences have been proposed to help improve the temperature-to-noise ratio (TNR) in MR thermometry. The present work establishes how much of an improvement these so-called "PSIF-FISP" sequences may bring in various organs and tissues. METHODS: Simulations and TNR calculations were validated against analytical equations, phantom, abdomen, and brain scans. Relative TNRs for PSIF-FISP, as compared to a dual-FISP reference standard, were calculated for flip angle (FA) = 1 to 85 º and repetition time (TR) = 6 to 60 ms, for gray matter, white matter, cervix, endometrium, myometrium, prostate, kidney medulla and cortex, bone marrow, pancreas, spleen, muscle, and liver tissues. RESULTS: PSIF-FISP was TNR superior in the kidney, pelvis, spleen, or gray matter at most tested TR and FA settings, and benefits increased at shorter TRs. PSIF-FISP was TNR superior in other tissues, e.g., liver, muscle, pancreas, for only short TR settings (20 ms or less). The TNR benefits of PSIF-FISP increased slightly with FA, and strongly with decreasing TR. Up to two- to three-fold reductions in TR with 20% TNR gains were achievable. In any given tissue, TNR performance is expected to further improve with heating, due to changes in relaxation rates. CONCLUSION: Dual-pathway PSIF-FISP can improve TNR and acquisition speed over standard gradient-recalled echo sequences, but optimal acquisition parameters are tissue dependent. Magn Reson Med 77:1193-1200, 2017. © 2016 International Society for Magnetic Resonance in Medicine.


Assuntos
Algoritmos , Temperatura Corporal/fisiologia , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Processamento de Sinais Assistido por Computador , Termografia/métodos , Humanos , Aumento da Imagem/métodos , Imagens de Fantasmas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Temperatura
11.
Magn Reson Med ; 78(3): 897-908, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-27739101

RESUMO

PURPOSE: To combine MRI, ultrasound, and computer science methodologies toward generating MRI contrast at the high frame rates of ultrasound, inside and even outside the MRI bore. METHODS: A small transducer, held onto the abdomen with an adhesive bandage, collected ultrasound signals during MRI. Based on these ultrasound signals and their correlations with MRI, a machine-learning algorithm created synthetic MR images at frame rates up to 100 per second. In one particular implementation, volunteers were taken out of the MRI bore with the ultrasound sensor still in place, and MR images were generated on the basis of ultrasound signal and learned correlations alone in a "scannerless" manner. RESULTS: Hybrid ultrasound-MRI data were acquired in eight separate imaging sessions. Locations of liver features, in synthetic images, were compared with those from acquired images: The mean error was 1.0 pixel (2.1 mm), with best case 0.4 and worst case 4.1 pixels (in the presence of heavy coughing). For results from outside the bore, qualitative validation involved optically tracked ultrasound imaging with/without coughing. CONCLUSION: The proposed setup can generate an accurate stream of high-speed MR images, up to 100 frames per second, inside or even outside the MR bore. Magn Reson Med 78:897-908, 2017. © 2016 International Society for Magnetic Resonance in Medicine.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Ultrassonografia/métodos , Algoritmos , Desenho de Equipamento , Humanos , Processamento de Imagem Assistida por Computador/instrumentação , Fígado/diagnóstico por imagem , Aprendizado de Máquina , Movimento/fisiologia , Transdutores
12.
Med Phys ; 43(4): 1873, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27036583

RESUMO

PURPOSE: To verify whether quantification of parotid perfusion is affected by fat signals on non-fat-saturated (NFS) dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) and whether the influence of fat is reduced with fat saturation (FS). METHODS: This study consisted of three parts. First, a retrospective study analyzed DCE-MRI data previously acquired on different patients using NFS (n = 18) or FS (n = 18) scans. Second, a phantom study simulated the signal enhancements in the presence of gadolinium contrast agent at six concentrations and three fat contents. Finally, a prospective study recruited nine healthy volunteers to investigate the influence of fat suppression on perfusion quantification on the same subjects. Parotid perfusion parameters were derived from NFS and FS DCE-MRI data using both pharmacokinetic model analysis and semiquantitative parametric analysis. T tests and linear regression analysis were used for statistical analysis with correction for multiple comparisons. RESULTS: NFS scans showed lower amplitude-related parameters, including parameter A, peak enhancement (PE), and slope than FS scans in the patients (all with P < 0.0167). The relative signal enhancement in the phantoms was proportional to the dose of contrast agent and was lower in NFS scans than in FS scans. The volunteer study showed lower parameter A (6.75 ± 2.38 a.u.), PE (42.12% ± 14.87%), and slope (1.43% ± 0.54% s(-1)) in NFS scans as compared to 17.63 ± 8.56 a.u., 104.22% ± 25.15%, and 9.68% ± 1.67% s(-1), respectively, in FS scans (all with P < 0.005). These amplitude-related parameters were negatively associated with the fat content in NFS scans only (all with P < 0.05). CONCLUSIONS: On NFS DCE-MRI, quantification of parotid perfusion is adversely affected by the presence of fat signals for all amplitude-related parameters. The influence could be reduced on FS scans.


Assuntos
Imageamento por Ressonância Magnética/métodos , Glândula Parótida/irrigação sanguínea , Glândula Parótida/diagnóstico por imagem , Fluxo Sanguíneo Regional , Adulto , Idoso , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Adulto Jovem
13.
J Magn Reson ; 265: 177-87, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26923150

RESUMO

PURPOSE: To present a dual-pathway multi-echo steady state sequence and reconstruction algorithm to capture T2, T2(∗) and field map information. METHODS: Typically, pulse sequences based on spin echoes are needed for T2 mapping while gradient echoes are needed for field mapping, making it difficult to jointly acquire both types of information. A dual-pathway multi-echo pulse sequence is employed here to generate T2 and field maps from the same acquired data. The approach might be used, for example, to obtain both thermometry and tissue damage information during thermal therapies, or susceptibility and T2 information from a same head scan, or to generate bonus T2 maps during a knee scan. RESULTS: Quantitative T2, T2(∗) and field maps were generated in gel phantoms, ex vivo bovine muscle, and twelve volunteers. T2 results were validated against a spin-echo reference standard: A linear regression based on ROI analysis in phantoms provided close agreement (slope/R(2)=0.99/0.998). A pixel-wise in vivo Bland-Altman analysis of R2=1/T2 showed a bias of 0.034 Hz (about 0.3%), as averaged over four volunteers. Ex vivo results, with and without motion, suggested that tissue damage detection based on T2 rather than temperature-dose measurements might prove more robust to motion. CONCLUSION: T2, T2(∗) and field maps were obtained simultaneously, from the same datasets, in thermometry, susceptibility-weighted imaging and knee-imaging contexts.


Assuntos
Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Algoritmos , Animais , Temperatura Corporal , Osso e Ossos/anatomia & histologia , Cartilagem Articular/anatomia & histologia , Bovinos , Cabeça , Voluntários Saudáveis , Humanos , Joelho/anatomia & histologia , Joelho/patologia , Músculo Esquelético/anatomia & histologia , Osteoartrite/diagnóstico , Osteoartrite/patologia , Imagens de Fantasmas
14.
PLoS One ; 10(8): e0137073, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26323091

RESUMO

PURPOSE: To concurrently quantify the radiation-induced changes and temporal evolutions of parotid volume and parotid apparent diffusion coefficient (ADC) in nasopharyngeal carcinoma (NPC) patients treated by intensity-modulated radiotherapy by using magnetic resonance imaging (MRI). MATERIALS AND METHODS: A total of 11 NPC patients (9 men and 2 women; 48.7 ± 11.7 years, 22 parotid glands) were enrolled. Radiation dose, parotid sparing volume, severity of xerostomia, and radiation-to-MR interval (RMI) was recorded. MRI studies were acquired four times, including one before and three after radiotherapy. The parotid volume and the parotid ADC were measured. Statistical analysis was performed using SPSS and MedCalc. Bonferroni correction was applied for multiple comparisons. A P value less than 0.05 was considered as statistically significant. RESULTS: The parotid volume was 26.2 ± 8.0 cm(3) before radiotherapy. The parotid ADC was 0.8 ± 0.15 × 10(-3) mm(2)/sec before radiotherapy. The parotid glands received a radiation dose of 28.7 ± 4.1 Gy and a PSV of 44.1 ± 12.6%. The parotid volume was significantly smaller at MR stage 1 and stage 2 as compared to pre-RT stage (P < .005). The volume reduction ratio was 31.2 ± 13.0%, 26.1 ± 13.5%, and 17.1 ± 16.6% at stage 1, 2, and 3, respectively. The parotid ADC was significantly higher at all post-RT stages as compared to pre-RT stage reciprocally (P < .005 at stage 1 and 2, P < .05 at stage 3). The ADC increase ratio was 35.7 ± 17.4%, 27.0 ± 12.8%, and 20.2 ± 16.6% at stage 1, 2, and 3, respectively. The parotid ADC was negatively correlated to the parotid volume (R = -0.509; P < .001). The parotid ADC was positively associated with the radiation dose significantly (R(2) = 0.212; P = .0001) and was negatively associated with RMI significantly (R(2) = 0.203; P = .00096) significantly. Multiple regression analysis further showed that the post-RT parotid ADC was related to the radiation dose and RMI significantly (R(2) = 0.3580; P < .0001). At MR stage 3, the parotid volume was negatively associated with the dry mouth grade significantly (R(2) = 0.473; P < .0001), while the parotid ADC was positively associated with the dry mouth grade significantly (R(2) = 0.288; P = .015). CONCLUSION: Our pilot study successfully demonstrates the concurrent changes and temporal evolution of parotid volume and parotid ADC quantitatively in NPC patients treated by IMRT. Our results suggest that the reduction of parotid volume and increase of parotid ADC are dominated by the effect of acinar loss rather than edema at early to intermediate phases and the following recovery of parotid volume and ADC toward the baseline values might reflect the acinar regeneration of parotid glands.


Assuntos
Neoplasias Nasofaríngeas/patologia , Neoplasias Nasofaríngeas/radioterapia , Glândula Parótida/patologia , Glândula Parótida/efeitos da radiação , Carcinoma , Relação Dose-Resposta à Radiação , Feminino , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Carcinoma Nasofaríngeo , Projetos Piloto , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/métodos , Xerostomia/patologia , Xerostomia/radioterapia
15.
Eur Radiol ; 24(9): 2069-76, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24972952

RESUMO

OBJECTIVES: To establish standard apparent diffusion coefficient (ADC) and the fat content as a function of age, gender and body mass index (BMI) in healthy parotid glands, and to address the influences of fat suppression on ADC measurements. METHODS: A total of 100 healthy adults (gender and age evenly distributed) were prospectively recruited, with parotid fat content measured from gradient-echo images with fat-water separated using iterative decomposition with echo asymmetry and least squares (IDEAL). The ADCs were estimated using both fat-saturated and non-fat-saturated diffusion-weighted imaging via a periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) technique. RESULTS: Parotid fat content was larger in men than in women by about 10 percentage points (P < 0.005), and positively associated with BMI and age for both genders (mostly with P < 0.001). ADCs estimated with non-fat-saturated PROPELLER were significantly lower in men than in women (P < 0.005), but showed no gender difference if measured using fat-saturated PROPELLER (P = 0.840). The negative association between parotid ADC and age/BMI/fat (P < 0.001) showed greater regression slopes in non-fat-saturated PROPELLER than in fat-saturated data. CONCLUSIONS: Parotid fat content in healthy adults correlates positively with both age and BMI; the correlation with age is gender-dependent. Parotid ADC measurements are strongly influenced by fat saturation. KEY POINTS: Parotid fat content in healthy adults correlates positively with age and BMI. The rate of aging-related increase in fat contents is gender-dependent. Parotid ADC measurements are strongly influenced by fat saturation.


Assuntos
Tecido Adiposo/anatomia & histologia , Índice de Massa Corporal , Imagem de Difusão por Ressonância Magnética/métodos , Imageamento Tridimensional/métodos , Glândula Parótida/anatomia & histologia , Adulto , Fatores Etários , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Valores de Referência , Fatores Sexuais
16.
Magn Reson Imaging ; 32(1): 102-6, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24211187

RESUMO

The dual echo steady-state (DESS) sequence has been shown successful in achieving fast T2 mapping with good precision. Under-estimation of T2, however, becomes increasingly prominent as the flip angle decreases. In 3D DESS imaging, therefore, the derived T2 values would become a function of the slice location in the presence of non-ideal slice profile of the excitation RF pulse. Furthermore, the pattern of slice-dependent variation in T2 estimates is dependent on the RF pulse waveform. Multi-slice 2D DESS imaging provides better inter-slice consistency, but the signal intensity is subject to integrated effects of within-slice distribution of the actual flip angle. Consequently, T2 measured using 2D DESS is prone to inaccuracy even at the designated flip angle of 90°. In this study, both phantom and human experiments demonstrate the above phenomena in good agreement with model prediction.


Assuntos
Imageamento por Ressonância Magnética/métodos , Encéfalo/patologia , Simulação por Computador , Humanos , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional/métodos , Imagens de Fantasmas , Reprodutibilidade dos Testes
17.
Magn Reson Imaging ; 31(8): 1278-84, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23664679

RESUMO

PURPOSE: To investigate parotid perfusion in early-to-intermediate stage after parotid-sparing radiation dose using fat-saturated DCE-MRI, and to verify whether the perfusion alteration was related to radiation dose and the PSV. METHODS AND MATERIALS: Thirty-two parotid glands from 16 consecutive patients with pathologically proven nasopharyngeal carcinoma treated by IMRT were examined. The parotid glands received a radiation dose of 28.9±3.9Gy with a PSV of 43.1%±13.9%. Perfusion parameters were calculated using time-shifted Brix model from fat-saturated DCE-MRI data before (pre-RT) and in early-to-intermediate stage after (post-RT) IMRT. Paired t-test was used to evaluate perfusion changes, while Pearson's correlation test was used to examine perfusion dependency on radiation dose and PSV. For multiple comparisons Bonferroni correction was applied. RESULTS: Successful fat saturation was achieved in 29 of 32 parotid glands. Compared with pre-RT, the post-RT parotid glands showed significantly higher A, peak enhancement, and wash-in slope, plus a lower Kel, suggesting a mixed effect of increased vascular permeability and acinar loss. Linear regression showed that peak enhancement was positively associated with radiation dose in post-RT parotid glands. Kel and slope were negatively associated with PSV, while time-to-peak was positively associated with PSV significantly. CONCLUSIONS: Our results suggest that time-shifted Brix model is feasible for quantifying parotid perfusion using DCE-MRI. The perfusion alterations in early-to-intermediate stage after IMRT might be related to a mixed effect of increased vascular permeability and acinar loss with dose and PSV dependencies.


Assuntos
Tecido Adiposo/patologia , Angiografia por Ressonância Magnética/métodos , Neoplasias Nasofaríngeas/patologia , Neoplasias Nasofaríngeas/radioterapia , Tratamentos com Preservação do Órgão/métodos , Glândula Parótida/patologia , Radioterapia Conformacional/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Carcinoma , Meios de Contraste , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Carcinoma Nasofaríngeo , Estadiamento de Neoplasias , Glândula Parótida/efeitos da radiação , Prognóstico , Dosagem Radioterapêutica , Estudos Retrospectivos , Resultado do Tratamento
18.
Radiology ; 267(3): 918-23, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23329654

RESUMO

PURPOSE: To evaluate the effectiveness of three fat measurement methods for parotid glands in healthy subjects, with or without metallic dental implants. MATERIALS AND METHODS: The institutional review board approved this study, with informed consent obtained from 114 volunteers undergoing magnetic resonance (MR) imaging at 1.5 T. Fat-saturated (FS) and non-fat-saturated (NFS) fast spin-echo T1-weighted imaging (T1 method), FS and NFS T2-weighted periodically rotated overlapping parallel lines with enhanced reconstruction fast spin-echo imaging (T2 method), and gradient-echo imaging with fat-water separation using iterative decomposition with echo asymmetry and least squares (IDEAL) method were used to derive parotid fat contents. Two raters examined the homogeneity of fat saturation to determine whether parotid fat quantification was successful, with the success rate in the 114 subjects recorded for each protocol. In subjects whose fat quantification was successful with all three imaging methods, linear regression was used to analyze the correlation between any pair of the three parotid fat content measurement methods. RESULTS: Success rates in parotid fat measurements by using T1, T2, and IDEAL methods were 87.7% (100 of 114), 87.7% (100 of 114), and 100% (114 of 114), respectively. The means of measured parotid fat contents revealed significant differences (P < .001) between any pair of the three measurement methods. The parotid fat contents measured with the three methods were significantly correlated with each other between any pair of combinations. CONCLUSION: The IDEAL method provided a high success rate for parotid fat measurements, even in subjects with metallic dental implants.


Assuntos
Tecido Adiposo/anatomia & histologia , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Glândula Parótida/anatomia & histologia , Implantes Dentários , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Análise dos Mínimos Quadrados , Modelos Lineares , Masculino , Metais , Pessoa de Meia-Idade , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...