Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Bioact Mater ; 5(1): 153-163, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32083229

RESUMO

Biodegradable magnesium (Mg)-based alloys have aroused great concern owing to their promising characteristics as temporary implants for orthopedic application. But their undesirably rapid corrosion rate under physiological conditions has limited the actual clinical application. This study reports the use of a novel biomimetic polyelectrolyte multilayer template, based on polyvinylpyrrolidone (PVP) and polyacrylic acid (PAA) via layer-by-layer (LbL) assembly, to improve the corrosion resistance of the alloy. Surface characterization techniques (field-emission scanning electron microscopy, Fourier transform infrared (FTIR) spectrophotometer and X-ray diffractometer) confirmed the formation of biomineralized Ca-P coating on AZ31 alloy. Both hydrogen evolution and electrochemical corrosion tests demonstrated that the corrosion protection of the polyelectrolyte-induced Ca-P coating on AZ31 alloy. The formation mechanism of biomineralized Ca-P coating was proposed.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA