Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Psychopharmacology (Berl) ; 241(5): 1093-1099, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38286858

RESUMO

OBJECTIVE: The objective of this study was to observe the changes in the levels of indoleamine 2, 3-dioxygenase (IDO) and tryptophan-2, 3-dioxygenase (TDO) in patients with major depressive disorder (MDD) and investigate their potential role as novel biomarkers for diagnosing MDD. METHODS: A total of 55 MDD patients and 55 healthy controls (HC) were enrolled in the study. The severity of MDD was assessed using the 24-item Hamilton Depression Rating Scale (HAMD-24) before and after treatment. The serum concentrations of IDO and TDO were measured at baseline and after treatment. The correlations between the serum levels of IDO and TDO and HAMD-24 scores were evaluated using Pearson's correlation test. Receiver operating characteristic (ROC) curve analysis was used to evaluate the area under the curve (AUC) of serum levels of IDO and TDO for discriminating MDD patients from HC. RESULTS: The serum IDO and TDO concentrations were significantly higher in patients with MDD at baseline than in healthy controls, and decreased significantly after 2 weeks or 1 month of treatment. The levels of IDO and TDO were significantly positively correlated with HAMD-24 scores. Furthermore, the AUC values for IDO and TDO were 0.999 and 0.966, respectively. CONCLUSION: The study suggests that serum IDO and TDO may serve as novel biomarkers for diagnosing MDD. These findings may lead to a better understanding of the pathogenesis of MDD and the development of new therapeutic targets.


Assuntos
Transtorno Depressivo Maior , Triptofano , Humanos , Transtorno Depressivo Maior/diagnóstico , Triptofano Oxigenase , Indolamina-Pirrol 2,3,-Dioxigenase , Biomarcadores
2.
Biomed Chromatogr ; 35(3): e4991, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33119931

RESUMO

A simple, rapid, and selective ultra-performance liquid chromatography-tandem mass spectrometry method for determination of l-carnitine (LC) and acetyl-l-carnitine (ALC) in human serum was developed. Acetyl-l-carnitine-d3 (ALC-d3 ) was selected as internal standard (IS). After protein precipitation with acetonitrile-water (1 mL, 2:1, v/v), the analytes and IS were separated on a 2.5-µm XSelect HSS T3 C18 column by gradient elution with methanol-water (containing 0.01% ammonia water) as the mobile phase at a flow rate of 0.2 mL/min. Analytes were detected with multiple reaction monitoring using a positive scan mode with electrospray ionization. Good linearity (R2 > 0.999) was observed in the concentration range for LC and ALC. The inter- and intra-day values of relative error were -10.4% to 10.0% with CVs less than 9.84%. The average recoveries of the two analytes were 91.29%-98.23%. Blood samples containing LC and ALC were stable under various storage conditions. Normal, haemolytic, and hyperlipidaemic serum had no significant effect on the quantification of LC and ALC. This method was successfully applied to study the concentrations of endogenous LC and ALC in the serum of patients with first-episode depression.


Assuntos
Carnitina/sangue , Cromatografia Líquida de Alta Pressão/métodos , Depressão/sangue , Espectrometria de Massas em Tandem/métodos , Acetilcarnitina/sangue , Humanos , Modelos Lineares , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA