Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Chinese Medical Journal ; (24): 172-180, 2024.
Artigo em Inglês | WPRIM (Pacífico Ocidental) | ID: wpr-1007740

RESUMO

BACKGROUND@#Oral anti-coagulants (OAC) are the intervention for the prevention of stroke, which consistently improve clinical outcomes and survival among patients with atrial fibrillation (AF). The main purpose of this study is to identify problems in OAC utilization among hospitalized patients with AF in China.@*METHODS@#Using data from the Improving Care for Cardiovascular Disease in China-Atrial Fibrillation (CCC-AF) registry, guideline-recommended OAC use in eligible patients was assessed.@*RESULTS@#A total of 52,530 patients with non-valvular AF were enrolled from February 2015 to December 2019, of whom 38,203 were at a high risk of stroke, 9717 were at a moderate risk, and 4610 were at a low risk. On admission, only 20.0% (6075/30,420) of patients with a diagnosed AF and a high risk of stroke were taking OAC. The use of pre-hospital OAC on admission was associated with a lower risk of new-onset ischemic stroke/transient ischemic attack among the diagnosed AF population (adjusted odds ratio: 0.54, 95% confidence interval: 0.43-0.68; P  <0.001). At discharge, the prescription rate of OAC was 45.2% (16,757/37,087) in eligible patients with high stroke risk and 60.7% (2778/4578) in eligible patients with low stroke risk. OAC utilization in patients with high stroke risk on admission or at discharge both increased largely over time (all P  <0.001). Multivariate analysis showed that OAC utilization at discharge was positively associated with in-hospital rhythm control strategies, including catheter ablation (adjusted odds ratio [OR] 11.63, 95% confidence interval [CI] 10.04-13.47; P <0.001), electronic cardioversion (adjusted OR 2.41, 95% CI 1.65-3.51; P <0.001), and anti-arrhythmic drug use (adjusted OR 1.45, 95% CI 1.38-1.53; P <0.001).@*CONCLUSIONS@#In hospitals participated in the CCC-AF project, >70% of AF patients were at a high risk of stroke. Although poor performance on guideline-recommended OAC use was found in this study, over time the CCC-AF project has made progress in stroke prevention in the Chinese AF population.Registration:ClinicalTrials.gov, NCT02309398.


Assuntos
Humanos , Administração Oral , Anticoagulantes/uso terapêutico , Fibrilação Atrial/complicações , Alta do Paciente , Pacientes , Sistema de Registros , Fatores de Risco , Acidente Vascular Cerebral/tratamento farmacológico
2.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-911441

RESUMO

Objective:To investigate the long-term safety of digoxin in patients with coronary artery disease (CAD) and atrial fibrillation (AF).Methods:This was a prospective study, in which 25 512 AF patients were enrolled from China Atrial Fibrillation Registry Study. After exclusion of patients receiving ablation therapy at the enrollment, 1 810 CAD patients [age: (71.5±9.3)years] with AF were included. The subjects were grouped into the digoxin group and non-digoxin group, and were followed up for a period of 80 months. Long-term outcomes were compared between the groups and an adjusted Cox regression analysis was applied to evaluate the risk of digoxin on the long-term outcomes. The primary endpoint was all-cause mortality.Results:The patients were followed up for a median period of 3.05 years. After multivariable adjustment, the Cox regression analysis showed that digoxin significantly increased the risk of all-cause mortality ( HR=1.28, 95% CI 1.01-1.61, P=0.038), cardiovascular mortality ( HR=1.48,95% CI 1.10-2.00, P=0.010), cardiovascular hospitalization ( HR=1.67,95% CI 1.35-2.07, P=0.008) and the composite endpoints ( HR=2.02,95% CI 1.71-2.38, P<0.001). In the subgroup of patients with heart failure (HF), digoxin was not associated with the risk of all-cause mortality, but was still associated with the increased risk of cardiovascular mortality ( HR=1.44,95% CI 1.05-1.98, P=0.025), cardiovascular hospitalization ( HR=1.44,95% CI 1.09-1.90, P=0.010) and the composite endpoints ( HR=1.37, 95% CI 1.01-1.70, P=0.004). However, in the subgroup of patients without HF, digoxin was only associated with all-cause mortality ( HR=2.56,95% CI 1.44-4.54, P=0.001). Conclusion:Digoxin significantly increased the risk of all-cause mortality in CAD patients with AF, especially in patients without HF.

3.
Chinese Journal of Cardiology ; (12): 595-601, 2019.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-805705

RESUMO

Objectives@#This study explored the relationship between weight control and atrial fibrillation (AF) recurrence after catheter ablation in overweight and obese patients.@*Methods@#We prospectively enrolled consecutive 333 overweight and obese patients aged 28 to 87 years old, who underwent catheter ablation for AF in Beijing Anzhen Hospital between October 2015 and February 2016. Data of patients′ characteristics, laboratory examination and treatment were collected at baseline. Each patient was followed up at 3, 6 and 12 months after ablation to collect information on weight, AF recurrence, stroke, major bleeding, hospitalization for cardiovascular reasons and death, etc. Patients were divided into weight controlled group (ΔBMI<-1 kg/m2) and weight uncontrolled group (ΔBMI≥-1 kg/m2), according to the changes in the most recent exposure BMI before AF recurrence in patients with recurrence or the BMI at 12 months′ follow-up in patients without recurrence and the BMI at baseline. Multivariate logistic regression was performed to adjust other known risk factors of AF recurrence and to explore the association between weight control and AF recurrence after catheter ablation.@*Results@#There were 54 patients in weight controlled group and 279 patients in weight uncontrolled group. There were no significant differences in age, gender, education level, left atrial size and history of hypertension between the two groups (all P>0.05). The proportion of patients using angiotensin-converting enzyme inhibitors/angiotensin receptor blockers was higher in the weight controlled group (50.0%(27/54) vs. 34.8%(97/279), P=0.034). However, there was no significant difference in the proportion of patients with obesity (33.3% (18/54) vs. 29.7% (83/279)), paroxysmal AF (59.3% (32/54) vs. 56.6% (158/279)) and AF duration less than 5 years (76.9% (40/52) vs. 65.4% (178/272)) between the weight controlled group and the uncontrolled group. During 1-year follow-up after ablation, the recurrence rate of AF was significantly lower in the weight controlled group than that in the weight uncontrolled group (14.8% (8/54) vs. 32.6%(91/279), P=0.009). Multivariable logistic regression analysis shows that weight control is independently associated with a lower postoperative AF recurrence rate (OR=0.40, 95%CI 0.18-0.90, P=0.026).@*Conclusion@#Weight control is strongly associated with a lower AF recurrence rate after catheter ablation in overweight and obese patients.

4.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-615628

RESUMO

Objective The recurrence of perimitral atrial tachycardia is common after initial ablation of persistent atrial fibrillation (AF). The aim of the study is to explore a preferable ablation approach for perimitral atrial tachycardia in the redo ablation of persistent AF. Methods Seventy-four patients with perimitral atrial tachycardia after initial ablation for persistent AF were included in our study. Patients were distinguished into either the group of having ablation during tachycardia (Group A) or the group having ablation after cardioversion to sinus rhythm (Group B) according to the different ablation strategies. The procedural endpoints were pulmonary vein isolation and bidirectional conduction block of all the ablated lines. The primary endpoint of the study was freedom from atrial tachyarrhythmia recurrence during the follow-up period. Results There were statistical differences in baseline clinical data between the 2 groups. During the redo procedure, conduction recovery rate across the mitral isthmus (MI),cavotricuspid isthmus and left atial roofline were 100%, 40.5% and 48.6% respectively. The procedural time, fluoroscopy time, mapping time were longer in the patients of group A. During a mean follow-up of (16.9±6.3) months, 31 (72.1%) patients in group A and 21(67.7%) patients in group B maintained in sinus rhythm in the absence of antiarrhythmic durgs (P =0.771) . Conclusion In patients with perimitral atrial tachycardia after initial ablation for persistent AF,ablation in sinus rhythm is a more simplified method and as effective as ablation during tachycardia.

5.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-611393

RESUMO

Objective To investigate ablation characteristics of PVC/VT originating from left ventricle anterior papillary muscles.Methods This study included 10 patients of PVC/VT originating from left ventricle anterior papillary muscles from January 2015 to June 2016 in Beijing Anzhen Hospital.Electrophysiological mapping and radiofrequency ablation were completed using three-dimensional anatomical mapping system combined with three-dimensional intracardiac ultrasound technology.ECG and abaltion target diagram characteristics as well as the special anatomy were explored.Results All the 10 patients were successfully ablated and followed up for 12 months.One patient had recurrence within 12 months and no complications were recorded.The target sites localized at the tip (n =1),middle portion(n =4)or the base (n =5) of the LV-APM.Among 7 patients,the target sites were located at the anterior septal papillary muscle and in 3 patients were located in the free papillary muscle.9 patients were successfully ablated via anterograde trans-septal catheterization after the failure of retrograde approach.Premature QRS wave time were 152.80 ± 11.72 ms and 6 patients presented sharp potential at the targets during PVC/VT.Conclusions PVC/VT originating from left ventricle anterior papillary muscles have similar ECG and diagram characteristics that is different from which originating from left anterior fascicle.It is recommended to get the target via transseptalpuncure approach.Ablation target could be clearly positioned by three-dimensional intracardiac ultrasound technology.

6.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-611370

RESUMO

Objective Cryoballoon ablation of pulmonary vein (PV) ostia often induces a vagal response.This prospective study was designed to assess the effectiveness of prophylactic intravenous administration of atropine on hemodynamic impairment induced by cryoballoon ablation in patients with atrial fibrillation.Methods Twenty-five patients with paroxysmal atrial fibrillation undergoing cryoballoon ablation were prospectively enrolled and assigned to either the trial group on the control group.First twelve patients (the trial group) were administered 1 mg of atropine before deflation of the cryoballoon,while the following 13 patients (the control group) were given atropine only after the onset of the hemodynamic variation (decrease in heart rate and/or blood pressure).Treatment was considered effective when the hemodynamic variations were restored.Results In the trial group,three patients with transient hypotension did not require further supportive care throughout the procedures and one patient with hypotension required supportive management.In the control group,hypotension,bradycardia and mixed bradycardia with hypotension requiring supportive care occurred in six,three,and three patients,respectively.Overall,the rate of marked vagal responses was significantly lower when prophylactic atropine was administrated (4/12 vs.12/13 patients,P < 0.01).Conclusions Atropine is effective in the prevention of all types of vasovagal responses induced by cryoballoon ablation in patients with atrial fibrillation.

7.
Zhonghua Xin Xue Guan Bing Za Zhi ; 43(8): 695-9, 2015 Aug.
Artigo em Chinês | MEDLINE | ID: mdl-26955726

RESUMO

OBJECTIVE: To explore if CHA2DS2 VASc score can predict substrate for persistent atrial fibrillation ( AF) and outcome post catheter ablation of AF. METHODS: From January 2011 to December 2012,116 patients underwent catheter ablation of persistent AF in our department and were enrolled in this study. CHA2DS2VASc score was calculated as follows: two points were assigned for a history of stroke or transient ischemic attack and age ≥ 75 and 1 point each was assigned for age ≥ 65, a history of hypertension, diabetes,recent cardiac failure, vessel disease, female. Left atrial geometry ( LA) was reconstructed with a 3.5 mm tip ablation catheter with fill-in threshold 10 in CARTO system. The mapping catheter was stabled at each endocardial location for at least 3 seconds for recording. The electrogram recordings at each endocardial location were analyzed with a custom software embedded in the CARTO mapping system. Interval confidence level (ICL) was used to characterize complex fractionated atrial electrograms (CFAEs) . As the default setting of the software, ICL more than or equal to 7 was considered sites with a highly repetitive CFAEs complex. CFAEs index was defined as the fraction of area of ICL more than or equal to 7 to the left atrial surface. The CFAEs index and outcome of catheter ablation among different CHA2DS2VASc groups were compared. RESULTS: Of the 116 patients, CHA2DS2VASc was 0 in 33 patients, 1 in 31 patients and ≥ 2 in 52 patients. Left atrial surface ((121.2 ± 18.9) cm2, (133.6 ± 23.8) cm2, (133.9 ± 16.1) cm2, P = 0.008), left atrial volume ((103.6 ± 24.8) ml, (118.3 ± 27.8) ml, (120.9 ± 20.9) ml, P = 0.005) and CFAEs index (44.6% ± 22.4%, 54.2% ± 22.2%, 58.7% ± 23.1%, P = 0.023) increased in proportion with increasing CHA2DS2VASc. ICLmax, ICLmin and CFAEs spatial distribution were similar among the three groups. During the mean follow-up of (13 ± 8) months, the recurrence rate were 36.4%, 35.5%, 55.8% among the three groups (P = 0.025). CONCLUSION: A high CHA2DS2VASc score is associated with extensive AF substrate and higher recurrence rate post catheter ablation of persistent AF.


Assuntos
Fibrilação Atrial , Idoso , Ablação por Cateter , Técnicas Eletrofisiológicas Cardíacas , Feminino , Átrios do Coração , Insuficiência Cardíaca , Humanos , Hipertensão , Recidiva , Acidente Vascular Cerebral , Resultado do Tratamento
8.
Chinese Journal of Cardiology ; (12): 589-594, 2015.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-317711

RESUMO

<p><b>OBJECTIVE</b>To evaluate the efficacy of catheter ablation in Chinese hypertrophic cardiomyopathy (HCM) patients with atrial fibrillation (AF), and to determine the risk factors of AF recurrence.</p><p><b>METHODS</b>This study enrolled 40 HCM patients with AF who underwent primary AF ablation at Beijing Anzhen Hospital from June 2005 to June 2013. Ablation strategy included bilateral pulmonary vein isolation (PVI) for paroxysmal AF (n = 27) and PVI plus left atrial roof, mitral isthmus and tricuspid isthmus linear ablations for persistent AF (n = 13). AF recurrence was followed-up by means of electrocardiography or Holter monitoring. Risk factors associated with AF recurrence were determined by a Cox regression model and the predictive power was evaluated by receiver operating characteristic (ROC) curve.</p><p><b>RESULTS</b>After (34 ± 18) months follow-up, 30% (12/40) cases remained in sinus rhythm off antiarrhythmic drug, most AF recurrence (18/28, 64.3%) occurred within 1 year post ablation. Multivariate Cox regression demonstrated that left atrial dimension (LAD, HR = 1.124, 95% CI 1.051-1.202, P = 0.001) and female gender (HR = 3.304, 95% CI 1.397-7.817, P = 0.007) were independent risk factors of AF recurrence. The cut-off value of LAD at 43.5 mm predicted AF recurrence with sensitivity of 93.5% and specificity of 60.0%. Every 1 mm enlargement in LAD was associated with an increased risk of arrhythmia recurrence (HR = 1.095, 95% CI 1.031-1.163, P = 0.003).</p><p><b>CONCLUSIONS</b>AF ablation in Chinese HCM patients is safe and feasible. However, sinus rhythm maintenance rate is low at long-time follow-up. Most of the recurrent AF occurs within 1 year post AF ablation procedure. Left atrial diameter and female gender are independent risk factors of AF recurrence.</p>


Assuntos
Feminino , Humanos , Masculino , Antiarrítmicos , Fibrilação Atrial , Patologia , Terapêutica , Pequim , Cardiomiopatia Hipertrófica , Ablação por Cateter , Eletrocardiografia , Eletrocardiografia Ambulatorial , Átrios do Coração , Veias Pulmonares , Curva ROC , Recidiva , Fatores de Risco , Sensibilidade e Especificidade , Resultado do Tratamento
9.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-451327

RESUMO

Objective To identify the electrophysiological charateristics and cause of ridge gap related reentry after MI ablation in atrial ifbrillation patients. Methods Activation and entrainment mapping was performed in 82 redo cases for OAT recurrence in whom MI was ablated during the index produre. Once ridge gap related reentry was conifrmed, detailed mapping was performed in MI and ridge region. In addition, in 36 cases undergoing MI ablation and fulfilling criterion for bidirectional block, differential pacing was repeated at the ridge to identify a ridge gap. Results Out of 82 redo cases for OAT recurrence in whom MI was ablated during the index produre, 7 (8.5%) was found to be ridge gap related reentry. TCL was (247.9±19.2) ms, and the left atrial endocardial activation time was (145.4±17.7) ms, accounting for (58.5±3.2)%of TCL. However, wide double potential was recorded along the previous ablated MI line where PPI was (34.3±6.6) ms longer than TCL, while PPI was signiifcantly shorter at the ridge[PPI-TCL (11.4±3.9) ms, P<0.001]. Tachycardia was terminated at the ridge in 6 cases and at the corresponding site in coronary sinus in 1 case. No recurrence was found during follow-up for (11.1±4.5) months. In addition, in 36 patients undergoing MI ablation in whom criterion of bi-directional block was fuliflled, conduction gap located at the ridge was found in 5 (13.9%) cases. Conclusions MI ridge gap related reentry is a distinctive OAT, in which the ridge was used as the critical isthmus, whereas the previous ablated MI line is not part of the reentry. MI pseudo-block due to the ridge gap may lead to this type of recurrent tachycardia.

10.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-448122

RESUMO

Objective Identify the mechanism of induced atrial arrhythmias after pulmonary vein isolation (PVI) in patients with paroxysmal atrial ifbrillation(PAF), and investigate its long-term prognosis. Methods All patients with PAF undergoing PVI and induction test afterwards between Feburary 2010 and October 2010 were included. The induction protocol was rapid pacing initiated at cycle length of 250 ms with progressive shortening in a decrement of 10 ms down to 180 ms or refractoriness. Isoproterenol of 2-4μg/min was administrated as well. Inducibility was deifned as induction of atrial arrhythmia lasting >1 min. The mechanism of induced tachycardia was identiifed by activation mapping and entrainment mapping under the guidance of CARTO system. All patients were followed up by 36 months. Results Forty-nine atrial tachycardia were induced in 39 (19.7%) patients, including 35 organized atrial tachycardia (OAT) and 14 atrial ifbrillation (AF). The LA diameter was signiifcantly larger in inducible group than non-inducible group (39.5±6.6 mm vs. 36.7±5.2 mm, P=0.004). Macroreentry was the most common mechanism in induced OATs (28, 80.0%), and mitral isthmus was the most common critical site (20, 40.8%), followed by cavo-tricuspid isthmus (12, 24.5%), PV (6, 12.2%), LA septum (4, 8.2%), superior vena cava (3, 6.1%) and LA roof (1, 2.0%). Conclusions The most common mechanism of induced tachycardia by IV isoproterenol and rapid pacing is MI and CTI dependent after PVI in PAF patients, which can be succssefully eliminated by liner ablation, not increasing long-term recurrence rate.

11.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-448121

RESUMO

Objective To observe the management and outcome of the cardiac tamponade patients during the ablation procedure using two different anticoagulation strategies. Methods All the patients developed tamponade during the ablation procedure were enrolled from January 2007 to December 2013 in our center. In group 1, warfarin was discontinued 3 to 5 days before the procedure and low molecular weight heparin (LMWH) was administered subcutaneously until ablation procedure day. In group 2, warfarin was not discontinued and the international normalized ratio INR was to maintained between 2 and 3. Results There were 27 patients (0.6%) developed cardiac tamponade out of a total 4487 patients received ablation in our center. The baseline clinical characteristics including age, left atrium, the heparin dose and ACT during the procedure had no signiifcant difference between the groups, except that the INR was higher in the group 2 (0.9±0.1 vs. 2.3±0.5, P0.999). The median hospital day was similar in the 2 groups [(9.6±3.3) d vs. (12.1±4.5) d, P=0.167]. There were no other serious complications and no hospital death. Conclusions Non-discontinuation of warfarin during peri-procedural catheter ablation of AF is not signiifcantly different to bridging with LMWH in the management and outcome of acute cardiac tamponade.

12.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-342643

RESUMO

A temporary demand pacemaker with electrocardiosignal display is introduced in this paper. Double way low-noise electrocardiosignal preamplifier, amplitude limiter, high and low pass filter, 50 Hz notch filter, TTL level generator and stimulating pulse formation circuit are components of the hardware electrocircuit. The demand pacing and the electrocardiosignal display are separately controlled by the software in which the double microcontrollers communications technique is used. In this study, liquid crystal display is firstly used in body surface electrocardiosignal display or intracardial electrophysiologic signal display when the temporary demand pacemaker is installed and put into use. The machine has proven clinically useful and can be of wide appliation.


Assuntos
Humanos , Eletrocardiografia , Marca-Passo Artificial
13.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-342604

RESUMO

Polygraph has become a necessary instrument in interventional cardiology and fundamental research of medicine up to the present. In this study, a LabView development system (DS) (developed by NI in U.S.) used as software platform, a DAQ data acquisition module and universal computer used as hardware platform, were creatively coupled with our self-made low noise multi-channels preamplifier to develop Multi-channels electrocardiograph. The device possessed the functions such as real time display of physiological process, digit highpass and lowpass, 50Hz filtered and gain adjustment, instant storing, random playback and printing, and process control stimulation. Besides, it was small-sized, economically practical and easy to operate. It could advance the spread of cardiac intervention treatment in hospitals.


Assuntos
Eletrocardiografia , Monitorização Intraoperatória , Monitorização Fisiológica , Processamento de Sinais Assistido por Computador , Software
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...