Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Rev Sci Instrum ; 89(10): 10I118, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30399758

RESUMO

In time-resolved measurement for triton burnup in Korea Superconducting Tokamak Advanced Research (KSTAR) deuterium plasmas, an NE213 liquid scintillation detector was installed and operated during the 2017 KSTAR campaign. The detector is composed of an NE213 scintillator (50 mm in diameter and 10 mm in thickness) and a photomultiplier tube (PMT). The PMT anode signal was processed under a data acquisition system which contains a field programmable gate array circuit and pulse processing software that is capable of discriminating gamma-ray and neutron pulse signals. In order to determine an appropriate threshold level for the 14 MeV neutron signal resulting from triton burnup, the NE213 scintillation detector was calibrated by using d-d and d-t neutron generators at the National Fusion Research Institute and Intense 14 MeV Neutron Source Facility, OKTAVIAN, Osaka University, Japan. The detector was installed on KSTAR with a 10 mm thick soft-iron stray magnetic field shield and a radiation shield which consists of 100 mm thick lead blocks and 200 mm thick borated polyethylene blocks. A discrimination range for d-t neutron was determined based on test results from neutron generators and KSTAR. Data points selected from the discrimination range were consistent with the classical triton confinement characteristics. In conclusion, under condition of an input counting rate of 1.9 × 105 counts per second (CPS), the detector is able to measure triton burnup signals up to 500 CPS for various plasma parameters.

2.
Rev Sci Instrum ; 89(10): 10I101, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30399972

RESUMO

The behavior of the 1 MeV triton has been studied in order to understand the alpha particle confinement property in the deuterium operation of toroidal fusion devices. To obtain time evolution of the deuterium-tritium (D-T) neutron emission rate where the secondary DT neutron emission rate is approximately 1012 n/s, we designed two high detection efficiency scintillating fiber (Sci-Fi) detectors: a 1 mm-diameter scintillation fiber-based detector Sci-Fi1 and a 2 mm-diameter scintillation fiber-based detector Sci-Fi2. The test in an accelerator-based neutron generator was performed. The result shows that the directionality of each detector is 15° and 25°, respectively. It is found that detection efficiency for DT neutrons is around 0.23 counts/n cm2 for the Sci-Fi1 detector and is around 1.0 counts/n cm2 for the Sci-Fi2 detector.

3.
Rev Sci Instrum ; 88(9): 093503, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28964183

RESUMO

Feasibility of using conventional photo-multiplier tubes (PMTs) without a scintillator as an ex-vessel radiation detector in a tokamak environment is studied. Basic irradiation tests using standard gamma ray sources and a d-d neutron generator showed that the PMT is responding both to gamma photons and neutrons, possibly due to the direct generation of secondary electrons inside the PMT by the impingement of high energy photons. Because of the selective sensitivity of the PMT to hard x-ray and neutrons in ohmic and neutral beam injected plasmas, respectively, it is shown that the PMT with certain configuration can be utilized either to monitor the fluctuation in the fusion neutron generation rate or to study the behavior of runaway electrons in tokamaks.

4.
Rev Sci Instrum ; 87(11): 11D828, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910448

RESUMO

Measurements of the time-integrated triton burnup for deuterium plasma in Korea Superconducting Tokamak Advanced Research (KSTAR) have been performed following the simultaneous detection of the d-d and d-t neutrons. The d-d neutrons were measured using a 3He proportional counter, fission chamber, and activated indium sample, whereas the d-t neutrons were detected using activated silicon and copper samples. The triton burnup ratio from KSTAR discharges is found to be in the range 0.01%-0.50% depending on the plasma conditions. The measured burnup ratio is compared with the prompt loss fraction of tritons calculated with the Lorentz orbit code and the classical slowing-down time. The burnup ratio is found to increase as plasma current and classical slowing-down time increase.

5.
Rev Sci Instrum ; 86(8): 083509, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26329194

RESUMO

A Cherenkov-type neutron detector was newly developed and neutron measurement experiments were performed at Korea Superconducting Tokamak Advanced Research. It was shown that the Cherenkov neutron detector can monitor the time-resolved neutron flux from deuterium-fueled fusion plasmas. Owing to the high temporal resolution of the detector, fast behaviors of runaway electrons, such as the neutron spikes, could be observed clearly. It is expected that the Cherenkov neutron detector could be utilized to provide useful information on runaway electrons as well as fusion reaction rate in fusion plasmas.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...