Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
2.
J Thromb Haemost ; 2(2): 234-41, 2004 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-14995984

RESUMO

BACKGROUND: Direct factor (F)Xa inhibition is an attractive method to limit thrombotic complications during percutaneous coronary intervention (PCI). OBJECTIVES: To investigate drug levels achieved, effect on coagulation markers, and preliminary efficacy and safety of several doses of DX-9065a, an intravenous, small molecule, direct, reversible FXa inhibitor during PCI. PATIENTS AND METHODS: Patients undergoing elective, native-vessel PCI (n = 175) were randomized 4 : 1 to open-label DX-9065a or heparin in one of four sequential stages. DX-9065a regimens in stages I-III were designed to achieve concentrations of > 100 ng mL-1, > 75 ng mL-1, and > 150 ng mL-1. Stage IV used the stage III regimen but included patients recently given heparin. RESULTS: At 15 min median (minimum) DX-9065a plasma levels were 192 (176), 122 (117), 334 (221), and 429 (231) ng mL-1 in stages I-IV, respectively. Median whole-blood international normalized ratios (INRs) were 2.6 (interquartile range 2.5, 2.7), 1.9 (1.8, 2.0), 3.2 (3.0, 4.1), and 3.8 (3.4, 4.6), and anti-FXa levels were 0.36 (0.32, 0.38), 0.33 (0.26, 0.39), 0.45 (0.41, 0.51), and 0.62 (0.52, 0.65) U mL-1, respectively. Stage II enrollment was stopped (n = 7) after one serious thrombotic event. Ischemic and bleeding events were rare and, in this small population, showed no clear relation to DX-9065a dose. CONCLUSIONS: Elective PCI is feasible using a direct FXa inhibitor for anticoagulation. Predictable plasma drug levels can be rapidly obtained with double-bolus and infusion DX-9065a dosing. Monitoring of DX-9065a may be possible using whole-blood INR. Direct FXa inhibition is a novel and potentially promising approach to anticoagulation during PCI that deserves further study.


Assuntos
Anticoagulantes/administração & dosagem , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Inibidores do Fator Xa , Naftalenos/administração & dosagem , Propionatos/administração & dosagem , Trombose/prevenção & controle , Idoso , Anticoagulantes/sangue , Anticoagulantes/farmacocinética , Testes de Coagulação Sanguínea , Relação Dose-Resposta a Droga , Monitoramento de Medicamentos/métodos , Estudos de Viabilidade , Feminino , Heparina/administração & dosagem , Humanos , Coeficiente Internacional Normatizado , Cuidados Intraoperatórios , Masculino , Pessoa de Meia-Idade , Naftalenos/sangue , Naftalenos/farmacocinética , Projetos Piloto , Complicações Pós-Operatórias/prevenção & controle , Propionatos/sangue , Propionatos/farmacocinética , Trombose/etiologia
3.
Catheter Cardiovasc Interv ; 52(4): 530-4, 2001 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-11285613

RESUMO

Blade and balloon atrial septostomy has been used to reduce cardiopulmonary symptoms and as a bridge to lung or heart lung transplant in primary pulmonary hypertension. Due to severe right atrial dilatation and resultant loss of anatomical landmarks, the procedure is technically difficult, and the reported postprocedure mortality rate varies between 5% and 50%. Among others, marked systemic desaturation and systemic hypotension presumably secondary to an excessively large atrial septal defect have been reported as causes of postprocedure death. We report a case where a novel intracardiac catheter-based phased-array 5.5--10 MHz transducer with spectral and color-flow Doppler capabilities was used to assist a balloon atrial septostomy and to obtain hemodynamic data in a patient with end-stage pulmonary hypertension.


Assuntos
Ecocardiografia , Septos Cardíacos/cirurgia , Hipertensão Pulmonar/diagnóstico por imagem , Hipertensão Pulmonar/terapia , Cateterismo , Feminino , Átrios do Coração , Humanos , Pessoa de Meia-Idade , Transdutores
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA