Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-38760079

RESUMO

BACKGROUND AND PURPOSE: The first-generation photon-counting detector CT was recently introduced into clinical practice and represents a promising innovation in high-resolution CT imaging. The purpose of this study was to assess the image quality of ultra-high-resolution photon-counting detector CT compared with energy-integrating detector CT and to explore different reconstruction kernel sharpness levels for the evaluation of intracranial aneurysms. MATERIALS AND METHODS: Ten patients with intracranial saccular aneurysms who had previously undergone conventional energy-integrating detector CT were prospectively enrolled. CT angiograms were acquired on a clinical dual-source photon-counting detector CT in ultra-high-resolution mode and reconstructed with 4 vascular kernels (Bv36, Bv40, Bv44, Bv48). Quantitative and qualitative image-quality parameters of the intracranial arteries were evaluated. For the quantitative analysis (image noise, SNR, contrast-to-noise ratio), ROIs were manually placed at standard anatomic intracranial and extracranial locations by 1 author. In addition, vessel border sharpness was evaluated quantitatively. For the qualitative analysis, 3 blinded neuroradiologists rated photon-counting detector CT and energy-integrating detector CT image quality for the evaluation of the intracranial vessels (ie, the aneurysms and 9 standard vascular branching locations) on a 5-point Likert-type scale. Additionally, readers independently selected their preferred kernel among the 4 kernels evaluated on photon-counting detector CT. RESULTS: In terms of quantitative image quality, Bv48, the sharpest kernel, yielded increased image noise and decreased SNR and contrast-to-noise ratio parameters compared with Bv36, the smoothest kernel. Compared with energy-integrating detector CT, the Bv48 kernel offered better quantitative image quality for the evaluation of small intracranial vessels (P < .001). Image-quality ratings of the Bv48 were superior to those of the energy-integrating detector CT and not significantly different from ratings of the B44 reconstruction kernel. When comparing side by side all 4 photon-counting detector reconstruction kernels, readers selected the B48 kernel as the best to visualize the aneurysms in 80% of cases. CONCLUSIONS: Ultra-high-resolution photon-counting detector CT provides improved image quality for neurovascular imaging. Although the less sharp kernels provided superior SNR and contrast-to-noise ratio, the sharpest kernels delivered the best subjective image quality on photon-counting detector CT for the evaluation of intracranial aneurysms.

2.
Pediatr Radiol ; 53(12): 2478-2489, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37718373

RESUMO

BACKGROUND: Traditional spine magnetic resonance imaging (MRI) protocols require sedation in young children and uncooperative patients. There is an increased interest in non-sedated pediatric MRI protocols to reduce risks associated with anesthetic agents and improve MRI access. OBJECTIVE: To evaluate the image quality of pediatric non-sedated fast spine MRI. MATERIALS AND METHODS: We retrospectively reviewed 69 pediatric non-sedated fast spine MRI exams performed in 57 patients. Two blinded readers provided image quality ratings for the evaluation of bones, cranio-cervical junction, cerebrospinal fluid (CSF) spaces, spinal cord, soft tissues, ligaments, and overall diagnostic quality on a 1-5 scale, and determined whether there was evidence of syringomyelia, abnormal conus medullaris position, or filum terminale abnormality. RESULTS: Mean patient age was 7.2 years (age range ≤ 1-17). Indications included syringomyelia (n=25), spinal dysraphism (n=4), combination of both syringomyelia and spinal dysraphism (n=8), and other miscellaneous indications (n=32). The inter-observer agreement ranged between moderate and very good for each variable (Cohen's weighted kappa] range=0.45-0.69). The highest image quality ratings were given to CSF spaces (mean image quality=3.5/5 ± 0.8) and cranio-cervical junction evaluations (3.5/5 ± 0.9). Overall diagnostic quality was worst in the <5 years group (P=0.006). Readers independently identified a cervical spinal cord syrinx in 6 cases, and 1 mm spinal cord central canal dilation in one case. Readers agreed on the position of the conus medullaris in 92% of cases (23/25 cases). CONCLUSION: Non-sedated pediatric spine MRI can be an effective diagnostic test to evaluate for spine pathology, especially syringomyelia, Chiari malformation, and conus medullaris anatomy.


Assuntos
Disrafismo Espinal , Siringomielia , Humanos , Criança , Pré-Escolar , Siringomielia/diagnóstico por imagem , Siringomielia/complicações , Estudos Retrospectivos , Coluna Vertebral , Imageamento por Ressonância Magnética/métodos , Disrafismo Espinal/complicações , Medula Espinal/diagnóstico por imagem
3.
Children (Basel) ; 10(1)2023 Jan 14.
Artigo em Inglês | MEDLINE | ID: mdl-36670710

RESUMO

This study investigated whether delayed receipt of antibiotics in infants with necrotizing enterocolitis (NEC) is associated with disease severity. In this retrospective, single-center cohort study of infants diagnosed with NEC over 4 years, we compared the timing of antibiotic administration in infants (time order placed to time of receipt) in medical and surgical NEC. Cases were independently reviewed, then various clinical factors were compared. Of 46 suspected cases, 25 were confirmed by a panel of radiologists with good interrater reliability (ICC 0.657; p < 0.001). Delays in antibiotic receipt were 1.7× greater in surgical than medical NEC cases (p = 0.049). Every hour after order entry increased the adjusted odds of surgical NEC by 2.4 (1.08−5.23; p = 0.032). Delayed antibiotic receipt was more common in infants with surgical than medical NEC. Larger studies will be needed to investigate if optimizing antibiotic expediency could improve intestinal outcomes.

4.
Br J Radiol ; 91(1086): 20170690, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29388807

RESUMO

Neuromyelitis optica is a neurotropic autoimmune inflammatory disease of the central nervous system traditionally thought to exclusively involve the optic nerves and spinal cord. With the discovery of the disease-specific aquaporin-4 antibody and the increasing recognition of clinical and characteristic imaging patterns of brain involvement in what is now termed neuromyelitis optica spectrum disorder (NMOSD), MRI now plays a greater role in diagnosis of NMOSD based on the 2015 consensus criteria and in distinguishing it from other inflammatory disorders, particularly multiple sclerosis (MS). Several brain lesion patterns are highly suggestive of NMOSD, whereas others may serve as red flags. Specifically, long corticospinal lesions, hemispheric cerebral white matter lesions and periependymal lesions in the diencephalon, dorsal brainstem and white matter adjacent to lateral ventricles are typical of NMOSD. In contrast, juxtacortical, cortical, or lesions perpendicularly oriented to the surface of the lateral ventricle suggests MS as the diagnosis. Ultimately, a strong recognition of the spectrum of MRI brain findings in NMOSD is essential for accurate diagnosis, and particularly in differentiating from MS. This pictorial review highlights the spectrum of characteristic brain lesion patterns that may be seen in NMOSD and further delineates findings that may help distinguish it from MS.


Assuntos
Encéfalo/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Neuromielite Óptica/diagnóstico por imagem , Adulto , Idoso , Tronco Encefálico/diagnóstico por imagem , Aqueduto do Mesencéfalo/diagnóstico por imagem , Ventrículos Cerebrais/diagnóstico por imagem , Diencéfalo/diagnóstico por imagem , Feminino , Humanos , Ventrículos Laterais/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Tratos Piramidais/diagnóstico por imagem , Substância Branca/diagnóstico por imagem
5.
PeerJ ; 5: e3586, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28828238

RESUMO

OBJECTIVE: This study aims to compare the sensitivity of dual phase (non-contrast and arterial) versus single phase (arterial) CT for detection of hyper-functioning parathyroid glands in patients with primary hyperparathyroidism. METHODS: The CT scans of thirty-two patients who have biochemical evidence of primary hyperparathyroidism, pathologically proven parathyroid adenomas, and pre-operative multiphase parathyroid imaging were evaluated retrospectively in order to compare the adequacy of single phase vs. dual phase CT scans for the detection of parathyroid adenomas. RESULTS: The parathyroid adenomas were localized in 83% of cases on single arterial phase CT and 80% of cases on dual phase CT. The specificity for localization of parathyroid tumor was 96% for single phase CT and 97% for dual phase CT. The results were not significantly different (p = 0.695). These results are similar to those found in the literature for multiphase CT of 55-94%. CONCLUSIONS: Our study supports the use of a single arterial phase CT for the detection of hyperfunctioning parathyroid adenomas. Advances in knowledge: a single arterial phase CT has similar sensitivity for localizing parathyroid adenomas as dual phase CT and significantly reduces radiation dose to the patient.

6.
J Magn Reson Imaging ; 39(3): 590-7, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24532376

RESUMO

PURPOSE: To assess the correlation among MR elastography (MRE) measured liver stiffness (LS), liver fibrosis, and hepatic venous pressure gradient (HVPG) in a swine model of cirrhosis. MATERIALS AND METHODS: Three swine served as controls, and liver fibrosis was induced in eight swine by transarterial embolization. LS and HVPG were obtained at baseline and 4 weeks (prenecropsy) following induction of liver fibrosis. RESULTS: Four weeks following the induction of liver cirrhosis, experimental animals developed an increase in HVPG of 8.0±6.4 mmHg compared with 0.3±1.2 mmHg for controls (P=0.08). Over the same timeframe, mean MRE-measured LS increased 0.82±0.39 kPa for experimental swine and 0.1±0.05 kPa for controls (P=0.01). A positive correlation was observed between increases in HVPG and LS (ρ=0.682; P=0.02). Liver fibrosis was measured on explanted livers at 4 weeks and yielded mean fibrosis scores of 2.8 for experimental animals and 0 for controls (P=0.0016). A positive correlation was observed between higher LS and liver fibrosis (ρ=0.884; P=0.0003). CONCLUSION: MRE is a reliable noninvasive technique to measure LS in a swine model of cirrhosis. Significant positive correlations were observed between LS and HVPG as well as LS and fibrosis.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Cirrose Hepática/diagnóstico , Pressão na Veia Porta , Análise de Variância , Animais , Biópsia por Agulha , Modelos Animais de Doenças , Imuno-Histoquímica , Cirrose Hepática/patologia , Curva ROC , Distribuição Aleatória , Valores de Referência , Sus scrofa , Suínos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA