Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Surg Innov ; 29(2): 215-224, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33980081

RESUMO

Purpose. The emergence of robotic-assisted surgical techniques has gained significant indications in terms of reduced trauma, shortened recovery, and higher patients' satisfaction. However, limitations by present surgical robotic systems used in natural orifice transluminal endoscopic surgery (NOTES) gynecology still exists, such as arm collisions, countertraction, instrument dexterity, and, in particular, space confinement due to the narrow pelvic anatomy. The current study evaluated the use of a miniaturized single-site surgical robotic system and its feasibility in performing robotic NOTES gynecological procedures using a live porcine animal model. Methods. Using a transrectal approach, the fully internalized robotic arms were deployed in a reverse configuration to access the lower pelvic cavity of the animals to perform NOTES gynecological procedures. Results. Robotic-assisted transrectal gynecological procedures were successfully performed using the new robotic system. A hemi-hysterectomy with unilateral salpingo-oophorectomy was completed in the first animal and a total hysterectomy with bilateral salpingo-oophorectomy in the second animal with an average docking time of 22.5 minutes and console time of 63 minutes and 58 minutes, respectively. The overall blood loss for each procedure was estimated to be <20 mL per animal with no intraoperative complications. Conclusions. The reverse configuration of the miniaturized surgical robotic system has demonstrated its capability to provide a potential solution to maintain clear visualization of the surgical field, optimal triangulation, and dexterity robotic NOTES gynecological procedures within the deep confined space of the pelvic cavity.


Assuntos
Laparoscopia , Cirurgia Endoscópica por Orifício Natural , Procedimentos Cirúrgicos Robóticos , Animais , Feminino , Humanos , Histerectomia , Laparoscopia/métodos , Cirurgia Endoscópica por Orifício Natural/métodos , Procedimentos Cirúrgicos Robóticos/métodos , Salpingo-Ooforectomia , Suínos
2.
Endosc Int Open ; 9(4): E537-E542, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33816774

RESUMO

Background and study aims Despite its widespread adoption, colonoscope still has its limitations. Advancement is often limited by the looping of colon. The isolation of SARS-CoV-2 in stool raises concern for the risk of disease transmission. A single-use robotic colonoscope, the NISInspire-C System, that features a balloon-suction anchorage mechanism was developed to address these. Methods The NISInspire-C balloons are designed to provide anchorage for straightening of the colon during advancement. Angulation at the bending section is tendon-wire driven by servo mechanisms integrated into a robotic control console. This was a pilot, prospective trial to evaluate the safety and feasibility of this system. Healthy volunteers underwent examination with the NISInspire-C, followed by the conventional colonoscope. The procedure time, cecal intubation rates (CIR), complications, and level of pain were measured. Results A total of 19 subjects underwent the examination. The cecal intubation rate was 89.5 % (17/19) and the overall time-to-cecum was 26.3 minutes (SD: 17.9 mins). There were no procedure-related complications. Polyps were detected in seven of 19 (36.8 %) subjects during the NISInspire-C procedure. Three more subjects were found to have adenomatous polyps with the conventional colonoscope. There was minimal variation in level of pain during the procedures with the two colonoscopes. Conclusion The single-use robotic colonoscope NISInspire-C is a safe and feasible alternative to the conventional colonoscope. Further technical refinement is needed to improve the CIR. This study was limited by its small sample size.

3.
Surg Innov ; 26(4): 436-441, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-30755092

RESUMO

Background. With increasing experience and technological advancement in surgical instruments, surgeons have explored the feasibility of single-incision laparoscopic surgery and natural orifice transluminal endoscopic surgery (NOTES). These techniques aim to further reduce surgical trauma, but are not popular due to their inherent pitfalls including clashing of instruments, lack of counter traction, lengthy operating time, and so on. A novel surgical robotic system was designed to overcome the limitations of the existing technologies. Animal trials were conducted to demonstrate its feasibility in performing robotic-assisted transrectal cholecystectomy in a porcine model. Method. The Novel surgical robotic system is a high dexterity, single access port surgical robotic system that enables surgeons to carry out single-port surgical procedure or NOTES. The proposed system's main features include the ability to perform intraabdominal and pelvic surgeries via natural orifices like the vagina or rectum. The system is equipped with multiple miniaturized (16 mm diameter) internally motorized robotic arms, each with a minimum of 7 degrees of freedom, a dual in vivo camera system, a cannula, and an external swivel system. Results. Robotic-assisted transrectal cholecystectomy was successfully performed in 3 adult male pigs. The estimated blood loss was <10 mL in all 3 cases. There were no intraoperative complications. The system provided good dexterity and clear vision. Conclusions. The trial demonstrated that the system can provide the surgeon a stable platform with adequate spacing for the transrectal insertion of robotic arms, 3-dimensional vision, and enhanced dexterity in performing NOTES cholecystectomy.


Assuntos
Colecistectomia/métodos , Cirurgia Endoscópica por Orifício Natural/métodos , Procedimentos Cirúrgicos Robóticos/métodos , Animais , Colecistectomia/instrumentação , Desenho de Equipamento , Masculino , Modelos Animais , Cirurgia Endoscópica por Orifício Natural/instrumentação , Reto , Procedimentos Cirúrgicos Robóticos/instrumentação , Suínos
4.
Artigo em Inglês | MEDLINE | ID: mdl-24517915

RESUMO

Real-time polymerase chain reaction is widely used in gene expression studies but this requires an appropriate referent gene for data normalization. So far, no gold standard is available and the selection has to be empirically validated. The aim of this study was to identify the most stable referent gene in exfoliated cervical cells with different degrees of cervical pathology. Seventy-five samples were used, 18 were from normal cervices, 18 from cervical intraepithelial neoplasia (CIN) 1, 17 from CIN 2, 17 from CIN 3, and 5 from squamous cell carcinoma. Using NormFinder, glyceraldehyde-3-phosphate dehydrogenase (GAPDH) was found to be the most stably expressed referent gene with a stability value of 0.37 across all lesion grades. Followed by RPL4 (stability value of 0.77) and ß-actin (0.77), large ribosomal protein P0 (1.01), and PKG1 (1.02). The results of expression stability by geNorm showed that normal cervices were more varied, with stability values ranging from 2.85 to 3.46, with ß-actin performing slightly better than GAPDH (M: 2.85 vs. 2.98). For the CIN 1 to 3, GAPDH was determined to be the most stably expressed gene (M: 0.94 to 1.37). The next most stable gene expressed was PKG1 (M: 1.02 to 1.44). However, the sample size for squamous cell carcinoma was too small for justification. In conclusion, overall GAPDH is the most stable referent gene expressed across all cervical lesion grades and is most suitable for normalization in gene expression studies.


Assuntos
Carcinoma de Células Escamosas/diagnóstico , Colo do Útero/fisiologia , Gliceraldeído-3-Fosfato Desidrogenase (Fosforiladora)/metabolismo , Displasia do Colo do Útero/diagnóstico , Neoplasias do Colo do Útero/diagnóstico , Feminino , Perfilação da Expressão Gênica , Gliceraldeído-3-Fosfato Desidrogenase (Fosforiladora)/genética , Humanos , Reação em Cadeia da Polimerase em Tempo Real , Padrões de Referência
5.
J Pediatr Hematol Oncol ; 34(6): 472-4, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22430584

RESUMO

We described a patient of refractory cytomegalovirus (CMV) limbic encephalitis who received matched unrelated bone marrow transplantation. Pyrosequencing study on serial cerebrospinal fluid samples revealed the emergence of resistant strains associated with exposure of antiviral agents. Combinations of antiviral agents had a role in partial suppression of CMV viral load but the clearance of virus mainly relied on the recovery of host's immunity and resulted in intact survival of host. Donor's CMV-seronegative status may contribute to the delay in controlling this serious infection. Prompt identification of drug-resistant mutant helps in selection of antiviral agents.


Assuntos
Anemia Aplástica/terapia , Infecções por Citomegalovirus/tratamento farmacológico , Farmacorresistência Viral , Ganciclovir/uso terapêutico , Transplante de Células-Tronco Hematopoéticas/efeitos adversos , Encefalite Límbica/etiologia , Encefalite Límbica/mortalidade , Anemia Aplástica/complicações , Antivirais/uso terapêutico , Criança , Citomegalovirus/patogenicidade , Infecções por Citomegalovirus/complicações , Infecções por Citomegalovirus/virologia , Feminino , Doença Enxerto-Hospedeiro/diagnóstico , Doença Enxerto-Hospedeiro/etiologia , Doença Enxerto-Hospedeiro/mortalidade , Humanos , Encefalite Límbica/diagnóstico , Prognóstico , Retinite/diagnóstico , Retinite/etiologia , Retinite/mortalidade , Taxa de Sobrevida
6.
J Infect Dis ; 190(2): 379-86, 2004 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-15216476

RESUMO

The recent outbreak of severe acute respiratory syndrome (SARS) provided an opportunity to study the antibody response of infected individuals to the causative virus, SARS coronavirus. We examined serum samples obtained from 46 patients with SARS, 40 patients with non-SARS pneumonia, and 38 healthy individuals, by use of Western blotting (WB), enzyme-linked immunoassay (ELISA), and immunofluorescence assay, using both native and bacterially produced antigens of the virus. We found a highly restricted, immunoglobulin G-dominated antibody response in patients with SARS, directed most frequently (89% by ELISA) and predominantly at the nucleocapsid. Almost all of the subjects without SARS had no antinucleocapsid antibodies. The spike protein was the next most frequently targeted, but only 63% of the patients (by ELISA) responded. Other targets of the response identified by use of WB included antigens of 80 and 60 kDa. Several nonstructural proteins cloned were not antigenic, and the culture-derived nucleocapsid appeared to be specifically degraded.


Assuntos
Anticorpos Antivirais/sangue , Nucleocapsídeo/imunologia , Síndrome Respiratória Aguda Grave/imunologia , Coronavírus Relacionado à Síndrome Respiratória Aguda Grave/imunologia , Adolescente , Adulto , Idoso , Antígenos Virais/imunologia , Western Blotting , Criança , Ensaio de Imunoadsorção Enzimática , Feminino , Técnica Indireta de Fluorescência para Anticorpo , Humanos , Imunoglobulina G/sangue , Masculino , Glicoproteínas de Membrana/imunologia , Pessoa de Meia-Idade , Peso Molecular , Síndrome Respiratória Aguda Grave/virologia , Glicoproteína da Espícula de Coronavírus , Proteínas do Envelope Viral/imunologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA