Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Cardiol ; 81(5): 434-440, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36372323

RESUMO

BACKGROUND: The neuromodulation effect after ventricular arrhythmia (VA) ablation is unclear. The study aimed to investigate skin sympathetic nerve activity (SKNA) changes in patients receiving catheter ablations for idiopathic VA. METHODS: Of 43 patients with drug-refractory symptomatic VA receiving ablation, SKNA was continuously recorded for 10 min during resting from electrocardiogram lead I configuration and bipolar electrodes on the right arm 1 day before and 1 day after ablation. RESULTS: Twenty-two patients with acute procedure success and no recurrence during follow-ups were classified as sustained success group (group 1). Other 21 patients were classified as failed ablation group (group 2). Baseline SKNA showed no significant difference between the two groups. Post-ablation SKNA in group 2 was significantly higher than in group 1. In patients with ablation involved right ventricular outflow tract (RVOT), the post-ablation SKNA was also significantly higher in group 2. In contrast, there was no difference in post-ablation SKNA between groups in patients receiving non-RVOT ablation. CONCLUSION: The neuromodulation response after RVOT ablation may correspond to the sympathetic nerve distribution at RVOT. Augmentation of sympathetic activity after VA ablation indicates an unsuccessful VA suppression, especially in patients receiving ablation of RVOT VA.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Humanos , Arritmias Cardíacas , Ventrículos do Coração , Ablação por Cateter/métodos , Sistema Nervoso Simpático/cirurgia , Pele , Eletrocardiografia , Taquicardia Ventricular/cirurgia , Resultado do Tratamento
2.
Circ J ; 87(1): 84-91, 2022 12 23.
Artigo em Inglês | MEDLINE | ID: mdl-36130901

RESUMO

BACKGROUND: Radiofrequency catheter ablation (RFCA) is commonly performed in patients with non-paroxysmal atrial fibrillation (AF), but because very long-term follow-up results of RFCA are limited, we investigated the 10-year RFCA outcomes of non-paroxysmal AF.Methods and Results: We retrospectively enrolled 100 patients (89 men, mean age 53.5±8.4years) with drug-refractory symptomatic non-paroxysmal AF who underwent 3D electroanatomic-guided RFCA. Procedural characteristics at index procedures and clinical outcomes were investigated. In the index procedures, all patients had pulmonary vein isolation, 56 (56.0%), 48 (48.0%), and 32 (32.0%) underwent additional linear, complex fractionated atrial electrogram (CFAE) and non-pulmonary vein (NPV) foci ablations, respectively. After 124.1±31.7 months, 16 (16%) patients remained in sinus rhythm after just 1 procedure (3 with antiarrhythmic drugs [AAD]) and after multiple (2.1±1.3) procedures in 53 (53.0%) patients (22 with AAD). Left atrial (LA) diameter (hazard ratio HR 1.061; 95% confidence interval (CI) 1.020 to 1.103; P=0.003), presence of NPV triggers (HR 1.634; 95% CI 1.019 to 2.623; P=0.042) and undergoing CFAE ablation (HR 2.003; 95% CI 1.262 to 3.180; P=0.003) in the index procedure were independent predictors for recurrent atrial tachyarrhythmia. CONCLUSIONS: The 10-year outcomes of single RFCA in non-paroxysmal AF were unsatisfactory. Enlarged LA, presence of NPV triggers, and undergoing CFAE ablation in the index procedure independently predicted single-procedure recurrence. Multiple procedures are required to achieve adequate rhythm control.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Masculino , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos , Átrios do Coração , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Antiarrítmicos/uso terapêutico , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
3.
J Cardiol ; 80(1): 34-40, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35337707

RESUMO

BACKGROUND: The identification of post pulmonary vein isolation (PVI) gaps by activation and voltage maps is time-consuming. This study aimed to investigate the characteristics, efficiency and accuracy of LiveView dynamic display module (EnSite™ Dynamic Display; Abbott, Abbott Park, IL, USA) in unmasking post PVI gaps and conduction block line. METHOD: Twenty four patients with paroxysmal atrial fibrillation (PAF) who failed to achieve first-pass PVI or with recurrent PAF were enrolled. Ninety-six pulmonary veins (PVs) were evaluated, and gaps were identified in 25 (26.0%) PVs. The gap location was confirmed by activation and propagation maps; 110 frames on gaps and 118 frames on block lines were analyzed by using LiveView module. We defined isochronal crowding in the local activation time (LAT) mode as three colors between two adjacent electrodes. Each frame was classified as with or without isochronal crowding in LAT mode and one/continuous color or isochronal discontinuity in reentrant mode. The gray color inside the PVs was considered to represent conduction block. RESULT: The isochronal crowding could be found on both gap and block line in LAT mode, whereas isochronal discontinuity only presented on the block line in reentrant mode. The sensitivity and specificity of isochronal discontinuity or gray color in reentrant mode to identify block line were 61.0% and 100%, respectively. The sensitivity and specificity of isochronal crowding or gray color in LAT mode to identify block line were 71.2% and 71.8%, respectively. CONCLUSION: Reentrant mode in LiveView module is very specific in identifying block lines. We proposed an efficient, practical algorithm to differentiate the block line from PV gaps.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/cirurgia , Humanos , Veias Pulmonares/cirurgia , Tecnologia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...