1.
Chronobiol Int ; 33(9): 1305-1310, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27385051

RESUMO

Working during the night can disrupt the normal circadian rhythm by altering the melatonin level. A low level of melatonin is associated with an increased risk of cancer, possibly by decreasing the expression of tumor-suppressor genes, such as p53. To determine whether nighttime work is associated with melatonin level in serum as well as the expression of related genetic markers, we enrolled 100 female nighttime medical technologists employed at a hospital in South Korea. Melatonin concentration and melatonin receptor 1 (MT1) expression were significantly lower in nighttime than in daytime workers (1.84 pg/mL versus 4.04 pg/mL; 1.16 versus 1.61, respectively). However, p53 expression showed no difference between the groups. In summary, nighttime work could be an important risk factor for circadian disruption, but not a direct risk factor for cancer in medical technologists in South Korea.


Assuntos
Ritmo Circadiano/fisiologia , Pessoal de Laboratório Médico , Melatonina/sangue , Jornada de Trabalho em Turnos , Adulto , Feminino , Regulação da Expressão Gênica/fisiologia , Humanos , Leucócitos/metabolismo , Metaloproteinase 14 da Matriz/genética , Metaloproteinase 14 da Matriz/metabolismo , Melatonina/metabolismo , Pessoa de Meia-Idade , República da Coreia , Proteína Supressora de Tumor p53/genética , Proteína Supressora de Tumor p53/metabolismo , Adulto Jovem
3.
Clin Chem Lab Med ; 51(11): 2201-8, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23898021

RESUMO

BACKGROUND: A novel enzymatic HbA1c assay was introduced for use in an automated chemistry analyzer. With this unique method, HbA1c and plasma glucose can be measured from the same EDTA tube. We evaluated the analytical performance of this enzymatic HbA1c assay in a JCA-BM6010/C analyzer and compared the HbA1c values with the results from other widely used methodological instruments. METHODS: The imprecision, linearity, carry-over and concordance rate of the enzymatic HbA1c test (BM Test HbA1c) using the JCA-BM6010/C analyzer were evaluated. Three hundred and seventy-seven specimens with HbA1c concentrations from 16 to 133 mmol/mol were used for a comparison study with two high performance liquid chromatography methods: Variant II Turbo and Tosoh HLC 723 G8 and the AutoLab Hemoglobin A1c immunoturbidimetry reagent using a Hitachi 7600-110. Forty specimens were used for the glucose method comparison. RESULTS: The HbA1c coefficients of variation of the within-run imprecision for low and high levels were 0.6% and 0.4%, respectively. The linearity of the BM Test HbA1c using the JCA-BM6010/C analyzer was excellent in the range between 31 mmol/mol and 143 mmol/mol. The carry-over rate was 0.2%. The relationships between the BM test and the other three methods were 0.916×Tosoh G8+3.644, r=0.986; 0.887×Bio-Rad Variant II+1.896, r=0.972; and 0.941×AutoLab+4.532, r=0.977. The concordance rates using a cut-off of 48 mmol/mol were 91.5% with Tosoh G8, 82.8% with Bio-Rad Variant II, and 91.0% with AutoLab. The simultaneously assayed plasma glucose with HbA1c was 1.002×Routine plasma glucose+0.625, r=1.000 CONCLUSIONS: The enzymatic BM Test HbA1c in the JCA-BM6010/C analyzer showed excellent precision and linearity, and a minimal carry-over rate. The simultaneously assayed plasma glucose analysis showed good performance.


Assuntos
Análise Química do Sangue/métodos , Glicemia/análise , Hemoglobinas Glicadas/análise , Nefelometria e Turbidimetria/métodos , Humanos , Modelos Lineares , Reprodutibilidade dos Testes