1.
Eur J Radiol ; 102: 55-60, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29685545

RESUMO

OBJECTIVE: Quantitative diffusion tensor imaging (DTI) of skeletal muscles is challenging due to the bias in DTI metrics, such as fractional anisotropy (FA) and mean diffusivity (MD), related to insufficient signal-to-noise ratio (SNR). This study compares the bias of DTI metrics in skeletal muscles via pixel-based and region-of-interest (ROI)-based analysis. METHODS: DTI of the thigh muscles was conducted on a 3.0-T system in N = 11 volunteers using a fat-suppressed single-shot spin-echo echo planar imaging (SS SE-EPI) sequence with eight repetitions (number of signal averages (NSA) = 4 or 8 for each repeat). The SNR was calculated for different NSAs and estimated for the composite images combining all data (effective NSA = 48) as standard reference. The bias of MD and FA derived by pixel-based and ROI-based quantification were compared at different NSAs. An "intra-ROI diffusion direction dispersion angle (IRDDDA)" was calculated to assess the uniformity of diffusion within the ROI. RESULTS: Using our standard reference image with NSA = 48, the ROI-based and pixel-based measurements agreed for FA and MD. Larger disagreements were observed for the pixel-based quantification at NSA = 4. MD was less sensitive than FA to the noise level. The IRDDDA decreased with higher NSA. At NSA = 4, ROI-based FA showed a lower average bias (0.9% vs. 37.4%) and narrower 95% limits of agreement compared to the pixel-based method. CONCLUSION: The ROI-based estimation of FA is less prone to bias than the pixel-based estimations when SNR is low. The IRDDDA can be applied as a quantitative quality measure to assess reliability of ROI-based DTI metrics.


Assuntos
Músculo Esquelético/anatomia & histologia , Adulto , Anisotropia , Imagem de Tensor de Difusão/métodos , Imagem Ecoplanar/métodos , Feminino , Humanos , Masculino , Estudos Prospectivos , Reprodutibilidade dos Testes , Razão Sinal-Ruído , Coxa da Perna
2.
Magn Reson Med ; 79(3): 1579-1585, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-28643355

RESUMO

PURPOSE: 1.5T gradient echo-based R2∗ estimates are standard-of-care for assessing liver iron concentration (LIC). Despite growing popularity of 3T, echo time (TE) limitations prevent 3T liver iron quantitation in the upper half of the clinical range (LIC ⪆20 mg/g). In this work, a 3D radial pulse sequence was assessed to double the dynamic range of 3T LIC estimates. THEORY AND METHODS: The minimum TE limits the dynamic range of pulse sequences to estimate R2∗. 23 chronically-transfused human volunteers were imaged with 1.5T Cartesian gradient echo (1.5T-GRE), 3T Cartesian gradient echo (3T-GRE), and 3T ultrashort TE radial (3T-UTE) pulse sequences; minimum TEs were 0.96, 0.76, and 0.19 ms, respectively. R2∗ was estimated with an exponential signal model, normalized to 1.5T equivalents, and converted to LIC. Bland-Altman analysis compared 3T-based estimates to 1.5T-GRE. RESULTS: LIC by 3T-GRE was unbiased versus 1.5T-GRE for LIC ≤ 25 mg/g (sd = 9.6%); 3T-GRE failed to quantify LIC > 25 mg/g. At high iron loads, 3T-UTE was unbiased (sd = 14.5%) compared to 1.5T-GRE. Further, 3T-UTE estimated LIC up to 50 mg/g, exceeding 1.5T-GRE limits. CONCLUSION: 3T-UTE imaging can reliably estimate high liver iron burdens. In conjunction with 3T-GRE, 3T-UTE allows clinical LIC estimation across a wide range of liver iron loads. Magn Reson Med 79:1579-1585, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


Assuntos
Interpretação de Imagem Assistida por Computador/métodos , Sobrecarga de Ferro/diagnóstico por imagem , Ferro/análise , Fígado/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Adolescente , Adulto , Algoritmos , Criança , Feminino , Humanos , Fígado/química , Masculino , Imagens de Fantasmas , Adulto Jovem
3.
Acta Radiol ; 58(11): 1386-1394, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28165290

RESUMO

Background Robust fat suppression remains essential in clinical MRI to improve tissue signal contrast, minimize fat-related artifacts, and enhance image quality. Purpose To compare fat suppression between mDIXON turbo spin echo (TSE) and conventional frequency-selective and inversion-recovery methods in pediatric spine MRI. Material and Methods Images from T1-weighted (T1W) and T2-weighted (T2W) TSE sequences coupled with conventional methods and the mDIXON technique were compared in 36 patients (5.8 ± 5.4 years) at 3.0 T. Images from 42 pairs of T1W (n = 16) and T2W (n = 26) scans were acquired. Two radiologists reviewed the data and rated images using a three-point scale in two categories, including the uniformity of fat suppression and overall diagnostic image quality. The Wilcoxon rank-sum test was used to compare the scores. Results The Cohen's kappa coefficient for inter-rater agreement was 0.69 (95% confidence interval [CI], 0.56-0.83). Images from mDIXON TSE were considered superior in fat suppression ( P < 0.01) in 22 (rater 1) and 25 (rater 2) cases, respectively. In 13 (rater 1) and 11 (rater 2) cases, mDIXON TSE demonstrated improved diagnostic image quality ( P < 0.01). In three cases, fat suppression was superior using inversion-recovery and likewise in one case mDIXON had poorer image diagnostic quality. Lastly, mDIXON and conventional fat-suppression methods performed similarly in 17 (rater 1) and 14 (rater 2) cases, and yielded equal diagnostic image quality in 28 (rater 1) and 30 (rater 2) cases. Conclusion Robust fat suppression can be achieved with mDixon TSE pediatric spine imaging at 3.0 T and should be considered as a permanent replacement of traditional methods, in particular frequency-selective techniques.


Assuntos
Artefatos , Interpretação de Imagem Assistida por Computador/métodos , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Coluna Vertebral/diagnóstico por imagem , Tecido Adiposo , Adolescente , Adulto , Criança , Pré-Escolar , Feminino , Gadolínio , Humanos , Aumento da Imagem/métodos , Lactente , Recém-Nascido , Masculino , Estudos Prospectivos , Adulto Jovem
4.
Magn Reson Imaging ; 35: 132-140, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27580517

RESUMO

PURPOSE: To demonstrate the clinical feasibility of a new non-Cartesian cylindrically-distributed spiral 3D pseudo-continuous arterial spin labeling (pCASL) magnetic resonance imaging (MRI) pulse sequence in pediatric patients in quantifying cerebral blood flow (CBF) response to an acetazolamide (ACZ) vasodilator challenge. MATERIALS AND METHODS: MRI exams were performed on two 3 Tesla Philips Ingenia systems using 32 channel head coil arrays. After local institutional review board approval, the 3D spiral-based pCASL technique was added to a standard brain MRI exam and evaluated in 13 pediatric patients (average age: 11.7±6.4years, range: 1.4-22.2years). All patients were administered ACZ for clinically indicated reasons. Quantitative whole-brain CBF measurements were computed pre- and post-ACZ to assess cerebrovascular reserve. RESULTS: 3D spiral pCASL data were successfully reconstructed in all 13 cases. In 11 patients, CBF increased 2.8% to 93.2% after administration of ACZ. In the two remaining patients, CBF decreased by 2.4 to 6.0% after ACZ. The group average change in CBF due to ACZ was approximately 25.0% and individual changes were statistically significant (p<0.01) in all patients using a paired t-test analysis. CBF perfusion data were diagnostically useful in supporting conventional MR angiography and clinical findings. CONCLUSION: 3D cylindrically-distributed spiral pCASL MRI provides a robust approach to assess cerebral blood flow and reserve in pediatric patients.


Assuntos
Acetazolamida/administração & dosagem , Encéfalo/irrigação sanguínea , Encéfalo/diagnóstico por imagem , Circulação Cerebrovascular/fisiologia , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Adolescente , Adulto , Inibidores da Anidrase Carbônica/administração & dosagem , Criança , Pré-Escolar , Estudos de Viabilidade , Feminino , Humanos , Lactente , Masculino , Estudos Prospectivos , Marcadores de Spin , Adulto Jovem
5.
MAGMA ; 30(2): 107-112, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27624474

RESUMO

OBJECTIVE: We demonstrate the potential clinical utility of a 4D non-gadolinium dynamic angiography technique based on arterial spin-labeling called contrast inherent inflow enhanced multi-phase angiography (CINEMA) in pediatric patients. MATERIALS AND METHODS: CINEMA was qualitatively compared to conventional time-of-flight (TOF) angiography in a cohort of 31 pediatric patients at 3 Tesla. RESULTS: CINEMA data were successfully acquired and reconstructed in all patients with no image artifacts. There were no cases where CINEMA was rated inferior to TOF in depicting intracranial vessel conspicuity. In 19 cases, CINEMA was rated equivalent to TOF and in the 12 remaining cases CINEMA was rated superior to TOF. CONCLUSION: There is a steadily rising concern in adults and children over the potential effects of intracranial deposition of gadolinium. CINEMA is therefore a viable alternative in dynamic neurovascular imaging.


Assuntos
Angiografia/métodos , Artérias/fisiologia , Gadolínio/química , Angiografia por Ressonância Magnética , Neurônios/fisiologia , Circulação Cerebrovascular , Criança , Pré-Escolar , Meios de Contraste , Feminino , Humanos , Aumento da Imagem , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Lactente , Recém-Nascido , Masculino , Estudos Prospectivos , Marcadores de Spin
6.
Med Phys ; 41(9): 092302, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25186407

RESUMO

PURPOSE: To describe a quantitative method for determination of SNR that extracts the local noise level using a single diffusion data set. METHODS: Brain data sets came from a multicenter study (eight sites; three MR vendors). Data acquisition protocol required b=0, 700 s/mm2, fov=256×256 mm2, acquisition matrix size 128×128, reconstruction matrix size 256×256; 30 gradient encoding directions and voxel size 2×2×2 mm3. Regions-of-interest (ROI) were placed manually on the b=0 image volume on transverse slices, and signal was recorded as the mean value of the ROI. The noise level from the ROI was evaluated using Fourier Transform based Butterworth high-pass filtering. Patients were divided into two groups, one for filter parameter optimization (N=17) and one for validation (N=10). Six white matter areas (the genu and splenium of corpus callosum, right and left centrum semiovale, right and left anterior corona radiata) were analyzed. The Bland-Altman method was used to compare the resulting SNR with that from the difference image method. The filter parameters were optimized for each brain area, and a set of "global" parameters was also obtained, which represent an average of all regions. RESULTS: The Bland-Altman analysis on the validation group using "global" filter parameters revealed that the 95% limits of agreement of percent bias between the SNR obtained with the new and the reference methods were -15.5% (median of the lower limit, range [-24.1%, -8.9%]) and 14.5% (median of the higher limits, range [12.7%, 18.0%]) for the 6 brain areas. CONCLUSIONS: An FT-based high-pass filtering method can be used for local area SNR assessment using only one DTI data set. This method could be used to evaluate SNR for patient studies in a multicenter setting.


Assuntos
Imagem de Tensor de Difusão/métodos , Processamento de Imagem Assistida por Computador/métodos , Razão Sinal-Ruído , Adolescente , Artefatos , Encéfalo/patologia , Criança , Pré-Escolar , Conjuntos de Dados como Assunto , Feminino , Análise de Fourier , Humanos , Masculino , Estudos Multicêntricos como Assunto , Leucemia-Linfoma Linfoblástico de Células Precursoras/tratamento farmacológico , Leucemia-Linfoma Linfoblástico de Células Precursoras/patologia , Adulto Jovem
7.
Res Dev Disabil ; 35(1): 215-22, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24169376

RESUMO

Children with spina bifida have well recognized functional deficits of muscle, but little is known about the associated changes in muscle anatomy and composition. This study used water-fat magnetic resonance imaging (MRI) to measure fat infiltration in the lower extremity muscles of 11 children with myelomeningocele, the most severe form of spina bifida. MRI measurements of muscle fat fraction (FF) were compared against manual muscle test (MMT) scores for muscle strength. The FF measurements were objective and reliable with mean inter-rater differences of <2% and intraclass correlation coefficients>0.98. There was a significant inverse relationship between muscle FF and MMT scores (P ≤ 0.001). Surprisingly, however, muscles with negligible strength (MMT 0-1) exhibited a bimodal distribution of FF with one group having FF>70% and another group having FF<20%. The MRI also revealed striking heterogeneity amongst individual muscles in the same muscle group (e.g., 4% fat in one participant's lateral gastrocnemius vs. 88% in her medial gastrocnemius), as well as significant asymmetry in FF in one participant with asymmetric strength and sensation. These results suggest that quantitative water-fat MRI may serve as a biomarker for muscle degeneration which may reveal subclinical changes useful for predicting functional potential and prognosis.


Assuntos
Tecido Adiposo/patologia , Imageamento por Ressonância Magnética/métodos , Meningomielocele/patologia , Músculo Esquelético/patologia , Disrafismo Espinal/patologia , Tecido Adiposo/fisiologia , Adolescente , Água Corporal/fisiologia , Criança , Feminino , Humanos , Imageamento por Ressonância Magnética/normas , Masculino , Meningomielocele/fisiopatologia , Força Muscular/fisiologia , Músculo Esquelético/fisiologia , Prognóstico , Reprodutibilidade dos Testes , Disrafismo Espinal/fisiopatologia
8.
Magn Reson Imaging ; 32(2): 107-17, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24239336

RESUMO

PURPOSE: To report the observation of brown adipose tissue (BAT) with low fat content in neonates with hypoxic-ischemic encephalopathy (HIE) after they have undergone hypothermia therapy. MATERIALS AND METHODS: The local ethics committee approved the imaging study. Ten HIE neonates (3 males, 7 females, age range: 2-3days) were studied on a 3-T MRI system using a low-flip-angle (3°) six-echo proton-density-weighted chemical-shift-encoded water-fat pulse sequence. Fat-signal fraction (FF) measurements of supraclavicular and interscapular (nape) BAT and adjacent subcutaneous white adipose tissues (WAT) were compared to those from five non-HIE neonates, two recruited for the present investigation and three from a previous study. RESULTS: In HIE neonates, the FF range for the supraclavicular, interscapular, and subcutaneous regions was 10.3%-29.9%, 28.0%-57.9%, and 62.6%-88.0%, respectively. In non-HIE neonates, the values were 23.7%-42.2% (p=0.01), 45.4%-59.5% (p=0.06), and 67.8%-86.3% (p=0.38), respectively. On an individual basis, supraclavicular BAT FF was consistently the lowest, interscapular BAT values were higher, and subcutaneous WAT values were the highest (p<0.01). CONCLUSION: We speculate that hypothermia therapy in HIE neonates likely promotes BAT-mediated non-shivering thermogenesis, which subsequently leads to a depletion of the tissue's intracellular fat stores. We believe that this is consequently reflected in lower FF values, particularly in the supraclavicular BAT depot, in contrast to non-HIE neonates.


Assuntos
Tecido Adiposo Marrom/patologia , Hipotermia Induzida , Hipotermia/patologia , Hipóxia-Isquemia Encefálica/terapia , Imageamento por Ressonância Magnética , Feminino , Humanos , Recém-Nascido , Modelos Lineares , Masculino , Reprodutibilidade dos Testes , Água/química
9.
J Magn Reson Imaging ; 38(4): 885-96, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23440739

RESUMO

PURPOSE: To compare fat-signal fractions (FFs) and T2* values between brown (BAT) and white (WAT) adipose tissue located within the supraclavicular fossa and subcutaneous depots, respectively. MATERIALS AND METHODS: Twelve infants and 39 children were studied. Children were divided into lean and overweight/obese subgroups. Chemical-shift-encoded water-fat magnetic resonance imaging (MRI) was used to quantify FFs and T2* metrics in the supraclavicular and adjacent subcutaneous adipose tissue depots. Linear regression and t-tests were performed. RESULTS: Infants had lower supraclavicular FFs than children (P < 0.01) but T2* values were similar (P = 0.5). Lean children exhibited lower supraclavicular FFs and T2* values than overweight children (P < 0.01). In each individual infant and child, supraclavicular FFs were consistently lower than adjacent subcutaneous FFs. Supraclavicular T2* values were consistently lower than subcutaneous T2* values in children, but not in infants. FFs in both depots were positively correlated with age and weight in infants (P < 0.01). In children, they were correlated with weight and body mass index (BMI) (P < 0.01), but not age. Correlations between T2* and anthropometric variables existed in children (P < 0.01), but were absent in infants. CONCLUSION: Cross-sectional comparisons suggest variations in FF and T2* values in the supraclavicular and subcutaneous depots of infants and children, which are potentially indicative of physiological differences in adipose tissue fat content, amount, and metabolic activity.


Assuntos
Tecido Adiposo Marrom/anatomia & histologia , Tecido Adiposo Branco/anatomia & histologia , Imageamento por Ressonância Magnética , Adolescente , Antropometria , Composição Corporal , Índice de Massa Corporal , Criança , Pré-Escolar , Estudos Transversais , Feminino , Humanos , Lactente , Recém-Nascido , Modelos Lineares , Masculino , Obesidade , Sobrepeso , Gordura Subcutânea/anatomia & histologia , Água/química , Adulto Jovem
10.
AJR Am J Roentgenol ; 200(1): 177-83, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23255760

RESUMO

OBJECTIVE: The purpose of this study was to characterize human brown adipose tissue (BAT) with chemical-shift water-fat MRI and to determine whether trends and differences in fat-signal fractions and T2(*) relaxation times between BAT and white adipose tissue (WAT) are consistently observed postmortem and in vivo in infants, adolescents, and adults. MATERIALS AND METHODS: A postmortem body and eight patients were studied. A six-echo spoiled gradient-echo chemical-shift water-fat MRI sequence was performed at 3 T to jointly quantify fat-signal fraction and T2(*) in interscapular-supraclavicular BAT and subcutaneous WAT. To confirm BAT identity, biopsy and histology served as the reference in the postmortem study and PET/CT was used in five of the eight patients who required examination for medical care. RESULTS: Fat-signal fractions and T2(*) times were lower in BAT than in WAT in the postmortem example and in seven of eight patients. With the exception of one case, nominal comparisons between brown and white adipose tissues were statistically significant (p < 0.05). Between subjects, a large range of fat-signal fraction values was observed in BAT but not in WAT. CONCLUSION: We have shown that fat-signal fractions and T2(*) values jointly derived from chemical-shift water-fat MRI are lower in BAT than in WAT likely because of differences in cellular structures, triglyceride content, and vascularization. The two metrics can serve as complementary biomarkers in the detection of BAT.


Assuntos
Tecido Adiposo Marrom/patologia , Imageamento por Ressonância Magnética , Tecido Adiposo Marrom/diagnóstico por imagem , Tecido Adiposo Marrom/fisiologia , Tecido Adiposo Branco/diagnóstico por imagem , Tecido Adiposo Branco/patologia , Adolescente , Adulto , Biópsia , Cadáver , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Masculino , Pessoa de Meia-Idade , Imagem Multimodal , Tomografia por Emissão de Pósitrons , Tomografia Computadorizada por Raios X
11.
Med Phys ; 38(7): 4415-21, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21859042

RESUMO

PURPOSE: To propose a quality assurance procedure for routine clinical diffusion tensor imaging (DTI) using the widely available American College of Radiology (ACR) head phantom. METHODS: Analysis was performed on the data acquired at 1.5 and 3.0 T on whole body clinical MRI scanners using the ACR phantom and included the following: (1) the signal-to-noise ratio (SNR) at the center and periphery of the phantom, (2) image distortion by EPI readout relative to spin echo imaging, (3) distortion of high-b images relative to the b= 0 image caused by diffusion encoding, and (4) determination of fractional anisotropy (FA) and mean diffusivity (MD) measured with region-of-interest (ROI) and pixel-based approaches. Reproducibility of the measurements was assessed by five repetitions of data acquisition on each scanner. RESULTS: The SNR at the phantom center was approximately half of that near the periphery at both 1.5 and 3 T. The image distortion by the EPI readout was up to 7 mm at 1.5 T and 10 mm at 3 T. The typical distortion caused by eddy currents from diffusion encoding was on the order of 0.5 mm. The difference between ROI-based and pixel-based MD quantification was 1.4% at 1.5 T and 0.3% at 3 T. The ROI-based MD values were in close agreement (within 2%) with the reference values. The ROI-based FA values were approximately a factor of 10 smaller than pixel-based values and less than 0.01. The measurement reproducibility was sufficient for quality assurance (QA) purposes. CONCLUSIONS: This QA approach is simple to perform and evaluates key aspects of the scanner performance for DTI data acquisition using a widely available phantom.


Assuntos
Imagem de Difusão por Ressonância Magnética/instrumentação , Imagem de Difusão por Ressonância Magnética/normas , Cabeça/anatomia & histologia , Imagens de Fantasmas/normas , Garantia da Qualidade dos Cuidados de Saúde/métodos , Garantia da Qualidade dos Cuidados de Saúde/normas , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Estados Unidos
12.
J Magn Reson Imaging ; 26(3): 738-46, 2007 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-17729369

RESUMO

PURPOSE: To introduce and evaluate the performance of an automated fat quantification method for water-saturated magnetic resonance images. MATERIALS AND METHODS: A fat distribution model is proposed for fat quantification on water saturated magnetic resonance images. Fat from both full- and partial-volume voxels are accounted for in this model based on image intensity histogram analysis. An automated threshold method is therefore proposed to accurately quantify total fat. This method is compared to a traditional full-volume-fat-only method in phantom and human studies. In the phantom study, fat quantification was performed on MR images obtained from a human abdomen oil phantom and was compared with the true oil volumes. In the human study, results of the two fat quantification methods of six subjects were compared on abdominal images with different spatial resolutions. RESULTS: In the phantom study, the proposed method provided significantly more accurate estimations of true oil volumes compared to the reference method (P < 0.0001). In human studies, fat quantification using the proposed method gave much more consistent results on images with different spatial resolutions, and on regions with different degrees of partial volume averaging. CONCLUSION: The proposed automated method is simple, rapid, and accurate for fat quantification on water-saturated MR images.


Assuntos
Gordura Abdominal/patologia , Imageamento por Ressonância Magnética/métodos , Tecido Adiposo/metabolismo , Tecido Adiposo/patologia , Automação , Água Corporal , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional , Masculino , Imagens de Fantasmas , Reprodutibilidade dos Testes , Água/química
13.
J Magn Reson Imaging ; 21(3): 263-71, 2005 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-15723372

RESUMO

PURPOSE: To compare the performance of a novel water-saturated b-SSFP sequence with that of a conventional T1-weighted turbo spin echo (T1W TSE) sequence for abdominal fat quantification. MATERIALS AND METHODS: A water-saturated, segmented, three-dimensional balanced steady-state free precession (b-SSFP) sequence and a traditional T1W TSE sequence were both employed on phantom and human studies. For phantom studies, a dual-layered phantom with known internal/external oil volumes was imaged using the two sequences. Images obtained by the two sequences were both processed using a computer-aided semiautomatic program for oil volume quantification. For human studies, six volunteers were scanned axially, centered at L2-L3 levels. Signal-to-noise ratio (SNR)(fat), contrast-to-noise ratio (CNR)(fat-muscle), CNR(fat-large bowel), and CNR(fat-small bowel) were calculated on hand-drawn regions of interest (ROIs), and averaged over all six slices for each subject. Statistical analyses were then performed to determine the SNR and CNR differences between images obtained by the two techniques. RESULTS: The phantom studies show that water-saturated b-SSFP offers a significantly closer estimation of true oil volumes compared with that of T1W TSE (P < 0.0001), as well as a more accurate internal/external volume ratio (P = 0.0001). In human studies, three-dimensional water-saturated b-SSFP images demonstrated higher CNR than that of T1W TSE (P < 0.0005), and very close SNR(fat) (P = 0.045). CONCLUSION: The proposed three-dimensional water-saturated b-SSFP sequence can generate high quality fat-only abdominal images with high CNR and SNR in shorter scan duration than the conventional T1W TSE approach. As images generated by this sequence suffer from no flow artifacts, and are less sensitive to bulk, respiratory, and bowel motion, three-dimensional water-saturated b-SSFP is a faster and more robust method for improving abdominal fat quantification using MRI.


Assuntos
Abdome/anatomia & histologia , Tecido Adiposo/anatomia & histologia , Água Corporal , Imageamento Tridimensional/métodos , Adulto , Artefatos , Índice de Massa Corporal , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Valores de Referência