Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 161
Filtrar
1.
Dentomaxillofac Radiol ; 51(6): 20220044, 2022 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-35522698

RESUMO

OBJECTIVE: To determine the capacity of ultrasonographic image-based measurements of gingival height and alveolar bone level for monitoring periodontal health and disease. METHODS: Sixteen subjects were recruited from patients scheduled to receive dental care and classified as periodontally healthy (n = 10) or diseased (n = 6) according to clinical guidelines. A 40-MHz ultrasound system was used to measure gingival recession, gingival height, alveolar bone level, and gingival thickness from 66 teeth for comparison to probing measurements of pocket depth and clinical attachment level. Interexaminer variability and comparison between ultrasound measurements and probing measurements was performed via Bland-Altman analysis. RESULTS: Gingival recession and its risk in non-recessed patients could be determined via measurement of the supra- and subgingival cementoenamel junction relative to the gingival margin. Interexaminer bias for ultrasound image analysis was negligible (<0.10 mm) for imaged gingival height (iGH) and 0.45 mm for imaged alveolar bone level (iABL). Diseased subjects had significantly higher imaging measurements (iGH, iABL) and clinical measurements (probing pocket depth, clinical attachment level) than healthy subjects (p < 0.05). Subtraction of the average biologic width from iGH resulted in 83% agreement (≤1 mm difference) between iGH and probing pocket depth measurements. CONCLUSIONS: Ultrasonography has an equivalent diagnostic capacity as gold-standard physical probing for periodontal metrics while offering more detailed anatomical information.


Assuntos
Retração Gengival , Periodontite , Biomarcadores , Gengiva/diagnóstico por imagem , Humanos , Perda da Inserção Periodontal/diagnóstico por imagem , Bolsa Periodontal/diagnóstico por imagem , Ultrassonografia
2.
Sensors (Basel) ; 21(23)2021 Dec 06.
Artigo em Inglês | MEDLINE | ID: mdl-34884144

RESUMO

A resonator coupler for subcutaneous implants has been developed with a new impedance matching pattern added to the conventional loop antenna. The tuning element of a concentric metal pad contributes distributed capacitance and inductance to the planar inductive loop and improves resonance significantly. It provides a better qualify factor for resonant coupling and a much lower reflection coefficient for the implant electronics. Practical constraints are taken into account for designs including the requirement of operation within a regulated frequency band and the limited thickness for a monolithic implant. In this work, two designs targeting to operate in the two industrial, scientific, and medical (ISM) bands at 903 MHz and 2.45 GHz are considered. The tuning metal pad improves their resonances significantly, compared to the conventional loop designs. Since it is difficult to tune the implant antenna after implantation, the effects of tissue depth variations due to the individual's surgery and the appropriate implant depths are investigated. Simulations conducted with the dielectric properties of human skin documented in the literature are compared to measurements done with hydrated ground pork as phantoms. Experiments and simulations are conducted to explain the discrepancies in frequency shifts due to the uses of pork phantoms. The design method is thus validated for uses on human skin. A noninvasive localization method to identify the implant under the skin has been examined and demonstrated by both simulations and measurements. It can efficiently locate the subcutaneous implant based on the high quality-factor resonance owing to the tuning elements in both implant and transmitter couplers. The planar resonant coupler for wireless power transfer shows good performance and promise in subcutaneous applications for implants.


Assuntos
Próteses e Implantes , Impedância Elétrica , Humanos , Imagens de Fantasmas
3.
Comput Biol Med ; 135: 104565, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34157469

RESUMO

Zebrafish is a powerful and widely-used model system for a host of biological investigations, including cardiovascular studies and genetic screening. Zebrafish are readily assessable during developmental stages; however, the current methods for quantifying and monitoring cardiac functions mainly involve tedious manual work and inconsistent estimations. In this paper, we developed and validated a Zebrafish Automatic Cardiovascular Assessment Framework (ZACAF) based on a U-net deep learning model for automated assessment of cardiovascular indices, such as ejection fraction (EF) and fractional shortening (FS) from microscopic videos of wildtype and cardiomyopathy mutant zebrafish embryos. Our approach yielded favorable performance with accuracy above 90% compared with manual processing. We used only black and white regular microscopic recordings with frame rates of 5-20 frames per second (fps); thus, the framework could be widely applicable with any laboratory resources and infrastructure. Most importantly, the automatic feature holds promise to enable efficient, consistent, and reliable processing and analysis capacity for large amounts of videos, which can be generated by diverse collaborating teams.


Assuntos
Cardiomiopatias , Sistema Cardiovascular , Aprendizado Profundo , Animais , Contração Miocárdica , Peixe-Zebra
4.
Transl Behav Med ; 11(7): 1339-1347, 2021 07 29.
Artigo em Inglês | MEDLINE | ID: mdl-34132810

RESUMO

The COVID-19 pandemic has rapidly altered ambulatory health care delivery and may have worsened disparities in health care access. To assess the telehealth implementation experiences of ambulatory personnel in different disciplines and their perspectives on potential telehealth disparities, and to make recommendations for more equitable telehealth delivery. We used a convergent parallel mixed-methods design. Clinic managers from geriatric medicine, internal medicine, and psychiatry e-mailed a survey to clinicians and staff regarding experiences with telehealth care delivery. Quantitative survey responses were analyzed with Fisher's Exact tests. Qualitative responses were coded thematically. Recommendations were categorized by type of implementation strategy. Quantitative and qualitative findings on telehealth disparities were merged in a joint data display. Respondents (n = 147, 57% response rate) were distributed across three specialties: 66% internal medicine, 19% psychiatry, and 14% geriatric medicine. Prior to 2020, 77% of clinicians had never delivered telehealth services. By Spring 2020, 78% reported conducting more than half of clinic visits by telehealth. Among clinicians, 52% agreed/strongly agreed that rapid telehealth implementation exacerbated access to care disparities to: older adult patients, those with limited internet access, and those needing interpretation services. Staff expressed similar difficulties with telehealth set-up especially for these patients. To improve telehealth equity, clinicians recommended to: (i) change infrastructure; (ii) train and educate stakeholders; and (iii) support clinicians. Clinicians and staff reported specific subpopulations had challenges in accessing telehealth visits. To avoid perpetuating telehealth access disparities, further co-discovery of equitable implementation strategies with patients and clinics are urgently needed.


Assuntos
COVID-19 , Telemedicina , Idoso , Acessibilidade aos Serviços de Saúde , Humanos , Pandemias , SARS-CoV-2
5.
Sci Rep ; 7(1): 3894, 2017 06 20.
Artigo em Inglês | MEDLINE | ID: mdl-28634321

RESUMO

Pain perception temporarily exaggerates abrupt thermal stimulus changes revealing a mechanism for nociceptive temporal contrast enhancement (TCE). Although the mechanism is unknown, a non-linear model with perceptual feedback accurately simulates the phenomenon. Here we test if a mechanism in the central nervous system underlies thermal TCE. Our model successfully predicted an optimal stimulus, incorporating a transient temperature offset (step-up/step-down), with maximal TCE, resulting in psychophysically verified large decrements in pain response ("offset-analgesia"; mean analgesia: 85%, n = 20 subjects). Next, this stimulus was delivered using two thermodes, one delivering the longer duration baseline temperature pulse and the other superimposing a short higher temperature pulse. The two stimuli were applied simultaneously either near or far on the same arm, or on opposite arms. Spatial separation across multiple peripheral receptive fields ensures the composite stimulus timecourse is first reconstituted in the central nervous system. Following ipsilateral stimulus cessation on the high temperature thermode, but before cessation of the low temperature stimulus properties of TCE were observed both for individual subjects and in group-mean responses. This demonstrates a central integration mechanism is sufficient to evoke painful thermal TCE, an essential step in transforming transient afferent nociceptive signals into a stable pain perception.


Assuntos
Percepção da Dor , Estimulação Física , Temperatura , Algoritmos , Humanos , Modelos Teóricos , Dor Nociceptiva , Medição da Dor , Limiar da Dor
6.
Oncotarget ; 7(18): 26567-79, 2016 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-27034170

RESUMO

Prostate cancer can transform from androgen-responsive to an androgen-independent phenotype. The mechanism responsible for the transformation remains unclear. We studied the effects of an epigenetic modulator, phenethyl isothiocyanate (PEITC), on the androgen-responsive LNCaP cells. After treatment with PEITC, floating spheres were formed with characteristics of prostate cancer stem cells (PCSC). These spheres were capable of self-renewal in media with and without androgen. They have been maintained in both types of media as long term cultures. Upon androgen deprivation, the adherent spheres differentiated to neuroendocrine cells (NEC) with decreased proliferation, expression of androgen receptor, and PSA. NEC reverse differentiated to spheres when androgen was replenished. The sphere cells expressed surface marker CD44 and had enhanced histone H3K4 acetylation, DNMT1 down-regulation and GSTP1 activation. We hypothesize that PEITC-mediated alteration in epigenomics of LNCaP cells may give rise to sphere cells, whereas reversible androgenomic alterations govern the shuttling between sphere PCSC and progeny NEC. Our findings identify unrecognized properties of prostate cancer sphere cells with multi-potential plasticity. This system will facilitate development of novel therapeutic agents and allow further exploration into epigenomics and androgenomics governing the transformation to hormone refractory prostate cancer.


Assuntos
Anticarcinógenos/farmacologia , Diferenciação Celular/efeitos dos fármacos , Isotiocianatos/farmacologia , Células Neuroendócrinas/patologia , Neoplasias de Próstata Resistentes à Castração/patologia , Neoplasias da Próstata/patologia , Linhagem Celular Tumoral , Humanos , Masculino , Células-Tronco Neoplásicas/efeitos dos fármacos , Células-Tronco Neoplásicas/patologia , Células Neuroendócrinas/efeitos dos fármacos
7.
J Hematol Oncol ; 9: 3, 2016 Jan 12.
Artigo em Inglês | MEDLINE | ID: mdl-26759222

RESUMO

BACKGROUND: Hypoacetylation on histone H3 of human prostate cancer cells has been described. Little is known about the modifications of other histones from prostate cancer cells. METHODS: Histones were isolated from the prostate cancer cell line DU-145 and the non-malignant prostatic cell line RC170N/h. Post-translational modifications of histone H2B were determined by liquid chromatography-mass spectrometry (LC-MS)/MS. RESULTS: The histone H2B of the prostate cancer cell line DU-145 was found to have hypoacetylation, hypomethylation, and dephosphorylation as compared to the non-malignant prostatic cell line RC170N/h. H2B regained acetylation on multiple lysine residues, phosphorylation on Thr19, and methylation on Lys23 and Lys43 in the DU-145 cells after sodium butyrate treatment. CONCLUSIONS: The histone H2B of DU-145 prostate cancer cells are hypoacetylated, hypomethylated, and dephosphorylated. Histone deacetylase inhibitor reversed this phenotype. Epigenetic agent may therefore be useful for prostate cancer therapy and worth further investigation.


Assuntos
Histona Desacetilases/metabolismo , Histonas/metabolismo , Neoplasias da Próstata/metabolismo , Processamento de Proteína Pós-Traducional , Acetilação/efeitos dos fármacos , Sequência de Aminoácidos , Ácido Butírico/farmacologia , Linhagem Celular , Linhagem Celular Tumoral , Cromatografia Líquida , Inibidores de Histona Desacetilases/farmacologia , Histonas/genética , Humanos , Lisina/genética , Lisina/metabolismo , Masculino , Metilação/efeitos dos fármacos , Dados de Sequência Molecular , Fosforilação/efeitos dos fármacos , Neoplasias da Próstata/patologia , Espectrometria de Massas em Tandem , Treonina/genética , Treonina/metabolismo
8.
Med Eng Phys ; 38(2): 87-96, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26678325

RESUMO

Intraoperative neurophysiological monitoring (IONM) is utilized to minimize neurological morbidity during spine surgery. Transcranial motor evoked potentials (TcMEPs) are principal IONM signals in which the motor cortex of the subject is stimulated with electrical pulses and the evoked potentials are recorded from the muscles of interest. Currently available monitoring systems require the connection of 40-60 lengthy lead wires to the patient. These wires contribute to a crowded and cluttered surgical environment, and limit the maneuverability of the surgical team. In this work, it was demonstrated that the cumbersome wired system is vulnerable to electromagnetic interference (EMI) produced by operating room (OR) equipment. It was hypothesized that eliminating the lengthy recording wires can remove the EMI induced in the IONM signals. Hence, a wireless system to acquire TcMEPs was developed and validated through bench-top and animal experiments. Side-by-side TcMEPs acquisition from the wired and wireless systems in animal experiments under controlled conditions (absence of EMI from OR equipment) showed comparable magnitudes and waveforms, thus demonstrating the fidelity in the signal acquisition of the wireless solution. The robustness of the wireless system to minimize EMI was compared with a wired-system under identical conditions. Unlike the wired-system, the wireless system was not influenced by the electromagnetic waves from the C-Arm X-ray machine and temperature management system in the OR.


Assuntos
Artefatos , Fenômenos Eletromagnéticos , Potencial Evocado Motor , Monitorização Intraoperatória/instrumentação , Tecnologia sem Fio , Animais , Feminino , Salas Cirúrgicas , Ratos , Processamento de Sinais Assistido por Computador , Razão Sinal-Ruído , Fatores de Tempo
9.
Biochem Pharmacol ; 99: 123-31, 2016 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-26612419

RESUMO

A small molecule, Natura-α, a clinical stage investigational new drug for certain inflammatory diseases, has been evaluated for drug interaction with STAT3 and inhibiting systemic lupus erythematosus (SLE). Studies have revealed that it selectively inhibits STAT3-Y705 phosphorylation and, suppresses pro-inflammatory cytokines, stimulates anti-inflammatory cytokine IL-10, thereby skewing T cell differentiation from the Th1/Th17 lineages toward the Treg lineage. The potential binding of the drug to STAT3 protein has been investigated with a computational modeling and docking simulation using X-ray crystal structure of the STAT3ß homodimer. Natura-α was shown to directly bind to SH2 domain of STAT3 and forms H-bonds with amino acids Glu594 and Arg609. The phosphorylation of Y705 was prevented and making the formation of STAT3 homodimer impossible, thereby blocking STAT3 activation. The in vivo efficacy of Natura-α in SLE was evaluated in a bioassay with NZB/W female mice. Mice at week 19 were given orally Natura-α at 25 or 75 mg/kg, once a day, 5 days per week for 29 weeks. Mice were monitored weekly until 52 weeks of age. Both dosages were effective to reduce proteinuria and significantly improved animal survival rate. The renal functions were preserved with glomerular lesions reversed, which paralleled with decreased C3 deposit. The numbers of kidney cells stained with phosphorylated STAT3-Y705 remarkably decreased, demonstrating blocking of Y-705 phosphorylation by the treatment. Since NZB/W mice develop nephritis which resembles SLE in men, the data strongly suggests that Natura-α may be a potential effective therapeutic agent for lupus.


Assuntos
Indóis/metabolismo , Nefrite Lúpica/metabolismo , Fator de Transcrição STAT3/metabolismo , Domínios de Homologia de src/fisiologia , Sequência de Aminoácidos , Animais , Feminino , Indóis/química , Indóis/farmacologia , Camundongos , Camundongos Endogâmicos NZB , Dados de Sequência Molecular , Fosforilação/efeitos dos fármacos , Fosforilação/fisiologia , Ligação Proteica/fisiologia , Estrutura Terciária de Proteína , Fator de Transcrição STAT3/química , Domínios de Homologia de src/efeitos dos fármacos
10.
Sensors (Basel) ; 15(9): 24553-72, 2015 Sep 23.
Artigo em Inglês | MEDLINE | ID: mdl-26404311

RESUMO

In this paper, we report a power management system for autonomous and real-time monitoring of the neurotransmitter L-glutamate (L-Glu). A low-power, low-noise, and high-gain recording module was designed to acquire signal from an implantable flexible L-Glu sensor fabricated by micro-electro-mechanical system (MEMS)-based processes. The wearable recording module was wirelessly powered through inductive coupling transmitter antennas. Lateral and angular misalignments of the receiver antennas were resolved by using a multi-transmitter antenna configuration. The effective coverage, over which the recording module functioned properly, was improved with the use of in-phase transmitter antennas. Experimental results showed that the recording system was capable of operating continuously at distances of 4 cm, 7 cm and 10 cm. The wireless power management system reduced the weight of the recording module, eliminated human intervention and enabled animal experimentation for extended durations.


Assuntos
Técnicas Biossensoriais/instrumentação , Neurotransmissores/análise , Tecnologia sem Fio/instrumentação , Animais , Simulação por Computador , Eletricidade , Eletrodos , Ácido Glutâmico/análise , Ratos
11.
J Vis ; 14(13): 14, 2014 Nov 18.
Artigo em Inglês | MEDLINE | ID: mdl-25406159

RESUMO

When distinguishing whether a face displays a certain emotion, some regions of the face may contain more useful information than others. Here we ask whether people differentially attend to distinct regions of a face when judging different emotions. Experiment 1 measured eye movements while participants discriminated between emotional (joy, anger, fear, sadness, shame, and disgust) and neutral facial expressions. Participant eye movements primarily fell in five distinct regions (eyes, upper nose, lower nose, upper lip, nasion). Distinct fixation patterns emerged for each emotion, such as a focus on the lips for joyful faces and a focus on the eyes for sad faces. These patterns were strongest for emotional faces but were still present when viewers sought evidence of emotion within neutral faces, indicating a goal-driven influence on eye-gaze patterns. Experiment 2 verified that these fixation patterns tended to reflect attention to the most diagnostic regions of the face for each emotion. Eye movements appear to follow both stimulus-driven and goal-driven perceptual strategies when decoding emotional information from a face.


Assuntos
Emoções/fisiologia , Movimentos Oculares/fisiologia , Expressão Facial , Reconhecimento Visual de Modelos/fisiologia , Adulto , Atenção/fisiologia , Feminino , Fixação Ocular/fisiologia , Humanos , Masculino , Adulto Jovem
12.
Compend Contin Educ Dent ; 35(4): e18-24, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24773224

RESUMO

The objective of this study was to determine interleukin (IL)-1α and IL-8 levels in the gingival crevicular fluid (GCF) of patients with different levels of crown margin placements. Samples of GCF were obtained from 12 study participants with definitive full-coverage restorations with supragingival or equigingival crown margin placements. The periodontal status of the volunteers ranged from healthy to generalized severe periodontitis. Pocket depth and bleeding on probing were assessed at the clinical examination, and interleukin concentrations were determined by enzyme-linked immunosorbent assay (ELISA). Analysis of variance (ANOVA) was used to statistically compare interleukin concentrations between the control, supragingival, and equigingival GCF samples. Compared to controls (60.4 ± 8.9 pg/mL), the average IL-1α concentration in the GCF samples surrounding the supragingival margins was 53.8 ± 9.7 pg/mL and was 110.5 ± 23.3 pg/mL in the equigingival margins. Compared to controls (59.0 ± 14.1 pg/mL), the average IL-8 concentration in the supragingival margins was 46.9 ± 9.7 pg/mL and was 131.4 ± 27.5 pg/mL in the equigingival margins. The trend of higher levels of interleukins in GCF corresponding to equigingival margins was consistent, as was the trend of lower concentrations in supragingival margins compared to the controls; however, statistical significance was not achieved because of the wide biological variation within and between patients. In conclusion, differences in GCF IL-1α and IL-8 concentrations were observed when comparing fixed crown restorations with equigingival and supragingival margins. Gingival inflammation may be dependent on the periodontal condition in addition to restoration or margin placement.


Assuntos
Restauração Dentária Permanente , Líquido do Sulco Gengival/metabolismo , Interleucinas/metabolismo , Adulto , Idoso , Estudos de Casos e Controles , Ensaio de Imunoadsorção Enzimática , Humanos , Pessoa de Meia-Idade
13.
Gastrointest Endosc ; 77(4): 649-53, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23290721

RESUMO

BACKGROUND: Chronic GERD affects approximately 15% of adults in the United States and is one of the most prevalent clinical conditions involving the GI tract. The commercial tools for monitoring GERD include multichannel intraluminal impedance (MII) probes and pH-sensing capsules. However, MII probes cause discomfort, which alters patients' regular activities, whereas the pH-sensing capsule lacks the ability to detect weak or nonacid episodes, misses reflux episodes with similar pH values, and has a limited sampling rate and battery life. OBJECTIVE: To develop and test an implantable batteryless dual-sensor capsule that can be used to diagnose and monitor GERD. DESIGN: The implanted capsule is wirelessly powered by an external device. Simulated reflux episodes were created in 3 live porcine models. Impedance and pH data were continuously measured and recorded. INTERVENTION: The implant capsule was placed in the esophagus along with a commercial pH-sensing capsule for comparison. MAIN OUTCOME MEASUREMENTS: Precise impedance and pH readouts were obtained and compared with those from a commercial pH-sensing capsule. RESULTS: The wireless energy supplied by the external unit was strong enough to power the implant. The pH sensor accurately measured pH levels and the impedance sensor precisely located the reflux episodes. LIMITATION: Simulated reflux events in a pig model. CONCLUSION: Our wireless sensors are reliable in operation and provide accurate assessment of simulated reflux episodes. The entire device can potentially be used to diagnose and monitor GERD.


Assuntos
Monitoramento do pH Esofágico/instrumentação , Refluxo Gastroesofágico/diagnóstico , Implantes Experimentais , Animais , Desenho de Equipamento , Feminino , Suínos
14.
IEEE Trans Biomed Eng ; 60(1): 225-9, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22968201

RESUMO

In this letter, we developed an integrated neural probe prototype for optogenetic stimulation by microscale light-emitting diode (µLED) and simultaneous recording of neural activities with microelectrodes on a single-polyimide platform. Optogenetics stimulates in vivo neural circuits with high-cellular specificity achieved by genetic targeting and precise temporal resolution by interaction of light-gated ion channels with optical beam. In our newly developed optrode probe, during optogenetic stimulation of neurons, continuous sensing of neuronal activities in vicinity of the activation site can provide feedback to stimulation or examine local responses in signal pathways. In the device, focusing the light from the µLED was achieved with an integrated photo-polymerized lens. The efficacy of the optrode for cortical stimulation and recording was tested on mice visual cortex neurons expressing channelrhodopsin-2. Stimulation intensity and frequency-dependent spiking activities of visual cortex were recorded. Our device has shown advantages over fiber-coupled laser-based optrode in terms of closed-loop integration, single-implant compactness and lower electrical power requirements, which would be clinically applicable for future prosthetic applications in personalized medicine.


Assuntos
Microeletrodos , Neurônios/fisiologia , Optogenética/métodos , Potenciais de Ação/fisiologia , Animais , Eletrofisiologia/instrumentação , Eletrofisiologia/métodos , Desenho de Equipamento , Camundongos , Camundongos Transgênicos , Córtex Visual/citologia
15.
J Neural Eng ; 9(5): 056010, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22955012

RESUMO

Neurostimulation of the spinal cord or brain has been used to inhibit nociceptive signals in pain management applications. Nevertheless, most of the current neurostimulation models are based on open-loop system designs. There is a lack of closed-loop systems for neurostimulation in research with small freely-moving animals and in future clinical applications. Based on our previously developed analog wireless system for closed-loop neurostimulation, a digital wireless system with real-time feedback between recorder and stimulator modules has been developed to achieve multi-channel communication. The wireless system includes a wearable recording module, a wearable stimulation module and a transceiver connected to a computer for real-time and off-line data processing, display and storage. To validate our system, wide dynamic range neurons in the spinal cord dorsal horn have been recorded from anesthetized rats in response to graded mechanical stimuli (brush, pressure and pinch) applied in the hind paw. The identified nociceptive signals were used to automatically trigger electrical stimulation at the periaqueductal gray in real time to inhibit their own activities by the closed-loop design. Our digital wireless closed-loop system has provided a simplified and efficient method for further study of pain processing in freely-moving animals and potential clinical application in patients.


Assuntos
Potenciais de Ação/fisiologia , Medição da Dor/instrumentação , Processamento de Sinais Assistido por Computador/instrumentação , Tecnologia sem Fio/instrumentação , Animais , Estimulação Elétrica/instrumentação , Estimulação Elétrica/métodos , Feminino , Masculino , Medição da Dor/métodos , Ratos , Ratos Sprague-Dawley , Telemetria/instrumentação , Telemetria/métodos
16.
IEEE Trans Biomed Eng ; 59(11): 3131-9, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22922690

RESUMO

In this study, a device for gastroesophageal reflux disease (GERD) monitoring has been prototyped. The system consists of an implantable, batteryless and wireless transponder with integrated impedance and pH sensors; and a wearable, external reader that wirelessly powers up the transponder and interprets the transponded radio-frequency signals. The transponder implant with the total size of 0.4 cm × 0.8 cm × 3.8 cm harvests radio frequency energy to operate dual-sensor and load-modulation circuitry. The external reader can store the data in a memory card and/or send it to a base station wirelessly, which is optional in the case of multiple-patient monitoring in a hospital or conducting large-scale freely behaving animal experiments. Tests were carried out to verify the signal transduction reliability in different situations for antenna locations and orientation. In vitro, experiments were conducted in a mannequin model by positioning the sensor capsule inside the wall of a tube mimicking the esophagus. Different liquids with known pH values were flushed through the tube creating reflux episodes and wireless signals were recorded. Live pigs under anesthesia were used for the animal models with the transponder implant attached on the esophageal wall. The reflux episodes were created while the sensor data were recorded wirelessly. The data were compared with those recorded independently by a clinically used wireless pH sensor capsule placed next to our implant transponder. The results showed that our transponder detected every episode in both acid and nonacid nature, while the commercial pH sensor missed events that had similar, repeated pH values, and failed to detect pH values higher than 10. Our batteryless transponder does not require a battery thus allowing longer diagnosis and prognosis periods to monitor drug efficacy, as well as providing accurate assessment of GERD symptoms.


Assuntos
Monitoramento do pH Esofágico/instrumentação , Refluxo Gastroesofágico/diagnóstico , Implantes Experimentais , Animais , Impedância Elétrica , Feminino , Refluxo Gastroesofágico/fisiopatologia , Suínos , Tecnologia sem Fio
17.
IEEE Trans Neural Syst Rehabil Eng ; 20(4): 478-87, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22692935

RESUMO

Clinical studies have shown that spinal or cerebral neurostimulation can significantly relieve pain. Current neurostimulators work in an open loop; hence, their efficacy depends on the patient's or physician's comprehension of pain. We have proposed and developed a real-time automatic recognition program with signal processing functions to detect action potentials. By using a wireless neurorecording module, spinal neuronal responses to mechanical stimuli (brush, pressure, and pinch) applied to rats' hind paws were recorded. Nociceptive spinal responses were detected and suppressed by our automated module through delivering electrical stimulation to the periaqueductal gray (PAG). The interspike intervals (ISIs) of the fired action potentials were used to distinguish among the three different mechanical stimuli. Our system was able to detect the neuronal activity intensities and deliver trigger signals to the neurostimulator according to a pre-set threshold in a closed-loop feedback configuration, thereby suppressing excessive activity in spinal cord dorsal horn neurons.


Assuntos
Biorretroalimentação Psicológica/instrumentação , Terapia por Estimulação Elétrica/instrumentação , Dor Nociceptiva/fisiopatologia , Próteses e Implantes , Medula Espinal/fisiologia , Terapia Assistida por Computador/métodos , Tato , Potenciais de Ação , Animais , Desenho de Equipamento , Análise de Falha de Equipamento , Masculino , Dor Nociceptiva/prevenção & controle , Ratos , Ratos Sprague-Dawley , Telemetria/instrumentação
18.
Gastrointest Endosc ; 76(1): 179-84, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22726478

RESUMO

BACKGROUND: Gastric stimulation via high-frequency, low-energy pulses can provide an effective treatment for gastric dysmotility; however, the current commercially available device requires surgical implantation for long-term stimulation and is powered by a nonrechargeable battery. OBJECTIVE: To test and describe endoscopic implantation techniques and testing of stimulation of a novel, wireless, batteryless, gastric electrical stimulation (GES) device. DESIGN: Endoscopic gastric implantation techniques were implemented, and in vivo gastric signals were recorded and measured in a non-survival swine model (n = 2; 50-kg animals). INTERVENTION: Five novel endoscopic gastric implantation techniques and stimulation of a novel, wireless, batteryless, GES device were tested on a non-survival swine model. MAIN OUTCOME MEASUREMENTS: Feasibility of 5 new endoscopic gastric implantation techniques of the novel, miniature, batteryless, wireless GES device while recording and measurement of in vivo gastric signals. RESULTS: All 5 of the novel endoscopic techniques permitted insertion and securing of the miniaturized gastrostimulator. By the help of these methods and miniaturization of the gastrostimulator, successful GES could be provided without any surgery. The metallic clip attachment was restricted to the mucosal surface, whereas the prototype tacks, prototype spring coils, percutaneous endoscopic gastrostomy wires/T-tag fasteners, and submucosal pocket endoscopic implantation methods attach the stimulator near transmurally or transmurally to the stomach. They allow more secure device attachment with optimal stimulation depth. LIMITATIONS: Non-survival pig studies. CONCLUSION: These 5 techniques have the potential to augment the utility of GES as a treatment alternative, to provide an important prototype for other dysmotility treatment paradigms, and to yield insights for new technological interfaces between non-invasiveness and surgery.


Assuntos
Endoscopia Gastrointestinal/métodos , Neuroestimuladores Implantáveis , Implantação de Prótese/métodos , Tecnologia sem Fio , Animais , Terapia por Estimulação Elétrica/instrumentação , Gastroparesia/terapia , Masculino , Estômago/fisiologia , Suínos
19.
Physiol Meas ; 33(6): N29-37, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22635054

RESUMO

Stomach contractions are initiated and coordinated by an underlying electrical activity (slow waves), and electrical dysrhythmias accompany motility diseases. Electrical recordings taken directly from the stomach provide the most valuable data, but face technical constraints. Serosal or mucosal electrodes have cables that traverse the abdominal wall, or a natural orifice, causing discomfort and possible infection, and restricting mobility. These problems motivated the development of a wireless system. The bidirectional telemetric system constitutes a front-end transponder, a back-end receiver and a graphical userinter face. The front-end module conditions the analogue signals, then digitizes and loads the data into a radio for transmission. Data receipt at the backend is acknowledged via a transceiver function. The system was validated in a bench-top study, then validated in vivo using serosal electrodes connected simultaneously to a commercial wired system. The front-end module was 35 × 35 × 27 mm3 and weighed 20 g. Bench-top tests demonstrated reliable communication within a distance range of 30 m, power consumption of 13.5 mW, and 124 h operation when utilizing a 560 mAh, 3 V battery. In vivo,slow wave frequencies were recorded identically with the wireless and wired reference systems (2.4 cycles min−1), automated activation time detection was modestly better for the wireless system (5% versus 14% FP rate), and signal amplitudes were modestly higher via the wireless system (462 versus 3 86µV; p<0.001). This telemetric system for slow wave acquisition is reliable,power efficient, readily portable and potentially implantable. The device will enable chronic monitoring and evaluation of slow wave patterns in animals and patients.0967-3334/


Assuntos
Fenômenos Eletrofisiológicos , Motilidade Gastrointestinal/fisiologia , Miniaturização/métodos , Estômago/fisiologia , Telemetria/métodos , Animais , Cães , Análise de Fourier , Masculino , Tecnologia sem Fio
20.
Artigo em Inglês | MEDLINE | ID: mdl-23366441

RESUMO

In an effort to detect pain in an objective way, Electrocorticography (ECoG) signals were acquired from male Sprague-Dawley rats in response to thermally induced pain. A wearable, wireless multichannel system was utilized to acquire signals from freely-behaving animals during the experiments. ECoG signals were recorded before (baseline) and during the heat exposure for which animals withdrew their paws in response to the painful feeling. Analysis of the signals revealed a clear, high-amplitude peak at the moment of the paw withdrawal across all four recording channels in each test. Analysis in the frequency domain found the peaks coincided with an abrupt increase of delta rhythms (under 4 Hz). In the baseline, heating, and post-withdrawal segments, these rhythms were relatively low, indicating that the sharp increase in delta activity might be associated with pain. Theta, alpha, beta, and gamma rhythms were also measured, but no significant differences were found between each phase of the signals. These preliminary results are promising; however, more animal models will need to be tested to provide statistically significant results with high confidence.


Assuntos
Eletroencefalografia/instrumentação , Dor/diagnóstico , Tecnologia sem Fio/instrumentação , Animais , Masculino , Ratos , Ratos Sprague-Dawley
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...