Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
1.
Phys Med ; 120: 103332, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38518627

RESUMO

As part of translational research projects, mice may be irradiated on radiobiology platforms such as the one at the ARRONAX cyclotron. Generally, these platforms do not feature an integrated imaging system. Moreover, in the context of ultra-high dose-rate radiotherapy (FLASH-RT), treatment planning should consider potential changes in the beam characteristics and internal movements in the animal. A patient-like set-up and methodology has been implemented to ensure target coverage during conformal irradiations of the brain, lungs and intestines. In addition, respiratory cycle amplitudes were quantified by fluoroscopic acquisitions on a mouse, to ensure organ coverage and to assess the impact of respiration during FLASH-RT using the 4D digital phantom MOBY. Furthermore, beam incidence direction was studied from mice µCBCT and Monte Carlo simulations. Finally,in vivodosimetry with dose-rate independent radiochromic films (OC-1) and their LET dependency were investigated. The immobilization system ensures that the animal is held in a safe and suitable position. The geometrical evaluation of organ coverage, after the addition of the margins around the organs, was satisfactory. Moreover, no measured differences were found between CONV and FLASH beams enabling a single model of the beamline for all planning studies. Finally, the LET-dependency of the OC-1 film was determined and experimentally verified with phantoms, as well as the feasibility of using these filmsin vivoto validate the targeting. The methodology developed ensures accurate and reproducible preclinical irradiations in CONV and FLASH-RT without in-room image guidance in terms of positioning, dose calculation andin vivodosimetry.


Assuntos
Terapia com Prótons , Radioterapia Conformacional , Humanos , Camundongos , Animais , Prótons , Terapia com Prótons/métodos , Pulmão , Imagens de Fantasmas , Método de Monte Carlo , Carmustina , Etoposídeo , Dosagem Radioterapêutica
2.
Radiother Oncol ; 187: 109820, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37516363

RESUMO

The ability to reduce toxicity of ultra-high dose rate (UHDR) helium ion irradiation has not been reported in vivo. Here, we tested UHDR helium ion irradiation in an embryonic zebrafish model. Our results show that UHDR helium ions spare body development and reduce spine curvature, compared to conventional dose rate.


Assuntos
Hélio , Peixe-Zebra , Animais , Hélio/uso terapêutico , Planejamento da Radioterapia Assistida por Computador/métodos , Íons/uso terapêutico , Dosagem Radioterapêutica
3.
Phys Med ; 109: 102568, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37015168

RESUMO

Anatomical variations occur during head and neck (H&N) radiotherapy (RT) treatment. These variations may result in underdosage to the target volume or overdosage to the organ at risk. Replanning during the treatment course can be triggered to overcome this issue. Due to technological, methodological and clinical evolutions, tools for adaptive RT (ART) are becoming increasingly sophisticated. The aim of this paper is to give an overview of the key steps of an H&N ART workflow and tools from the point of view of a group of French-speaking medical physicists and physicians (from GORTEC). Focuses are made on image registration, segmentation, estimation of the delivered dose of the day, workflow and quality assurance for an implementation of H&N offline and online ART. Practical recommendations are given to assist physicians and medical physicists in a clinical workflow.


Assuntos
Neoplasias de Cabeça e Pescoço , Radioterapia Guiada por Imagem , Humanos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Pescoço , Cabeça , Radioterapia Guiada por Imagem/métodos , Neoplasias de Cabeça e Pescoço/radioterapia
4.
Phys Med ; 107: 102548, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36842260

RESUMO

INTRODUCTION: Many complexity metrics characterize modulated plans. First, this study aimed at identify the optimal complexity metrics to reduce workload associated to patient-specific quality assurance (PSQA) for our equipment and processes. Second, it intended to optimize our MLC modelling to improve measurement and calculation agreement with expectation of further reducing PSQA workload. METHODS: Correlation and sensitivity at specificity equals to 1 were evaluated for PSQA results and different complexity metrics. Thresholds to stop PSQA were determined. After validation of the optimal complexity metric and threshold for our equipment and process, the MLC modelling was reviewed with a recently published methodology. This method is based on measurements with a Farmer-type ionization chamber of synchronous and asynchronous sweeping gap plans. Effect on the PSQA results and the identified threshold was investigated. RESULTS: In our center, the most appropriate complexity metric for reducing our PSQA workload was the Modulation Complexity Score for VMAT (MCSv). The optimization of the MLC modelling significantly reduced the number of controlled plans, specifically for one of our two Varian Clinac. Any plan with a MCSv >= 0.34 is treated without PSQA. CONCLUSION: This study rationalized and reduced our PSQA workload by approximately 30%. It is a continuing work with new TPS, machine or PSQA equipment. It encourages centers to re-evaluate their MLC modelling as well as assess the benefit of complexity metrics to streamline their PSQA workflow. An easier access, at least for reporting, at best for optimizing plans, into the TPS would be beneficial for the community.


Assuntos
Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada , Humanos , Planejamento da Radioterapia Assistida por Computador/métodos , Carga de Trabalho , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/métodos , Benchmarking
5.
Adv Radiat Oncol ; 8(2): 101124, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36578276

RESUMO

Purpose: Recently, ultrahigh-dose-rate radiation therapy (UHDR-RT) has emerged as a promising strategy to increase the benefit/risk ratio of external RT. Extensive work is on the way to characterize the physical and biological parameters that control the so-called "Flash" effect. However, this healthy/tumor differential effect is observable in in vivo models, which thereby drastically limits the amount of work that is achievable in a timely manner. Methods and Materials: In this study, zebrafish embryos were used to compare the effect of UHDR irradiation (8-9 kGy/s) to conventional RT dose rate (0.2 Gy/s) with a 68 MeV proton beam. Viability, body length, spine curvature, and pericardial edema were measured 4 days postirradiation. Results: We show that body length is significantly greater after UHDR-RT compared with conventional RT by 180 µm at 30 Gy and 90 µm at 40 Gy, while pericardial edema is only reduced at 30 Gy. No differences were obtained in terms of survival or spine curvature. Conclusions: Zebrafish embryo length appears as a robust endpoint, and we anticipate that this model will substantially fasten the study of UHDR proton-beam parameters necessary for "Flash."

6.
Radiat Res ; 198(3): 318-324, 2022 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-35675499

RESUMO

During ultra-high dose rate (UHDR) external radiation therapy, healthy tissues appear to be spared while tumor control remains the same compared to conventional dose rate. However, the understanding of radiochemical and biological mechanisms involved are still to be discussed. This study shows how the hydrogen peroxide (H2O2) production, one of the reactive oxygen species (ROS), could be controlled by early heterogenous radiolysis processes in water during UHDR proton-beam irradiations. Pure water was irradiated in the plateau region (track-segment) with 68 MeV protons under conventional (0.2 Gy/s) and several UHDR conditions (40 Gy/s to 60 kGy/s) at the ARRONAX cyclotron. Production of H2O2 was then monitored using the Ghormley triiodide method. New values of GTS(H2O2) were added in conventional dose rate. A substantial decrease in H2O2 production was observed from 0.2 to 1.5 kGy/s with a more dramatic decrease below 100 Gy/ s. At higher dose rate, up to 60 kGy/s, the H2O2 production stayed stable with a mean decrease of 38% ± 4%. This finding, associated to the decrease in the production of hydroxyl radical (•OH) already observed in other studies in similar conditions can be explained by the well-known spur theory in radiation chemistry. Thus, a two-step FLASH-RT mechanism can be envisioned: an early step at the microsecond scale mainly controlled by heterogenous radiolysis, and a second, slower, dominated by O2 depletion and biochemical processes. To validate this hypothesis, more measurements of radiolytic species will soon be performed, including radicals and associated lifetimes.


Assuntos
Peróxido de Hidrogênio , Prótons , Radical Hidroxila , Radioquímica , Água
7.
Phys Imaging Radiat Oncol ; 21: 108-114, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35243041

RESUMO

BACKGROUND AND PURPOSE: Image-guided radiotherapy (IGRT) involves frequent in-room imaging sessions contributing to additional patient irradiation. The present work provided patient-specific dosimetric data related to different imaging protocols and anatomical sites. MATERIAL AND METHODS: We developed a Monte Carlo based software able to calculate 3D personalized dose distributions for five imaging devices delivering kV-CBCT (Elekta and Varian linacs), MV-CT (Tomotherapy machines) and 2D-kV stereoscopic images from BrainLab and Accuray. Our study reported the dose distributions calculated for pelvis, head and neck and breast cases based on dose volume histograms for several organs at risk. RESULTS: 2D-kV imaging provided the minimum dose with less than 1 mGy per image pair. For a single kV-CBCT and MV-CT, median dose to organs were respectively around 30 mGy and 15 mGy for the pelvis, around 7 mGy and 10 mGy for the head and neck and around 5 mGy and 15 mGy for the breast. While MV-CT dose varied sparsely with tissues, dose from kV imaging was around 1.7 times higher in bones than in soft tissue. Daily kV-CBCT along 40 sessions of prostate radiotherapy delivered up to 3.5 Gy to the femoral heads. The dose level for head and neck and breast appeared to be lower than 0.4 Gy for every organ in case of a daily imaging session. CONCLUSIONS: This study showed the dosimetric impact of IGRT procedures. Acquisition parameters should therefore be chosen wisely depending on the clinical purposes and tailored to morphology. Indeed, imaging dose could be reduced up to a factor 10 with optimized protocols.

8.
Med Phys ; 49(4): 2732-2745, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35179234

RESUMO

PURPOSE: The ARRONAX cyclotron facility offers the possibility to deliver proton beams from low to ultra-high dose rates (UHDR). As a good control of the dosimetry is a prerequisite of UHDR experimentations, we evaluated in different conditions the usability and the dose rate dependency of several radiochromic films commonly used for dosimetry in radiotherapy. METHODS: We compared the dose rate dependency of three types of radiochromic films: GAFchromic™ EBT3 and GAFchromic™ EBT-XD (Ashland Inc., Wayne, NJ, USA), and OrthoChromic OC-1 (OrthoChrome Inc., Hillsborough, NJ, USA), after proton irradiations at various mean dose rates (0.25, 40, 1500, and 7500 Gy/s) and for 10 doses (2-130 Gy). We also evaluated the dose rate dependency of each film considering beam structures, from single pulse to multiple pulses with various frequencies. RESULTS: EBT3 and EBT-XD films showed differences of response between conventional (0.25 Gy/s) and UHDR (7500 Gy/s) conditions, above 10 Gy. On the contrary, OC-1 films did not present overall difference of response for doses except below 3 Gy. We observed an increase of the netOD with the mean dose rate for EBT3 and EBT-XD films. OC-1 films did not show any impact of the mean dose rate up to 7500 Gy/s, above 3 Gy. No difference was found based on the beam structure, for all three types of films. CONCLUSIONS: EBT3 and EBT-XD radiochromic films should be used with caution for the dosimetry of UHDR proton beams over 10 Gy. Their overresponse, which increases with mean dose rate and dose, could lead to non-negligible overestimations of the absolute dose. OC-1 films are dose rate independent up to 7500 Gy/s in proton beams. Films response is not impacted by the beam structure. A broader investigation of the usability of OC-1 films in UHDR conditions should be conducted at intermediate and higher mean dose rates and other beam energies.


Assuntos
Dosimetria Fotográfica , Terapia com Prótons , Calibragem , Prótons , Radiometria
9.
Cancers (Basel) ; 13(21)2021 Oct 28.
Artigo em Inglês | MEDLINE | ID: mdl-34771565

RESUMO

Physical activity is increasingly recognized as a strategy able to improve cancer patient outcome, and its potential to enhance treatment response is promising, despite being unclear. In our study we used a preclinical model of prostate cancer to investigate whether voluntary wheel running (VWR) could improve tumor perfusion and enhance radiotherapy (RT) efficiency. Nude athymic mice were injected with PC-3 cancer cells and either remained inactive or were housed with running wheels. Apparent microbubble transport was enhanced with VWR, which we hypothesized could improve the RT response. When repeating the experiments and adding RT, however, we observed that VWR did not influence RT efficiency. These findings contrasted with previous results and prompted us to evaluate if the lack of effects observed on tumor growth could be attributable to the physical activity modality used. Using PC-3 and PPC-1 xenografts, we randomized mice to either inactive controls, VWR, or treadmill running (TR). In both models, TR (but not VWR) slowed down tumor growth, suggesting that the anti-cancer effects of physical activity are dependent on its modalities. Providing a better understanding of which activity type should be recommended to cancer patients thus appears essential to improve treatment outcomes.

10.
Cancers (Basel) ; 13(8)2021 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-33920758

RESUMO

Proton therapy (PRT) is an irradiation technique that aims at limiting normal tissue damage while maintaining the tumor response. To study its specificities, the ARRONAX cyclotron is currently developing a preclinical structure compatible with biological experiments. A prerequisite is to identify and control uncertainties on the ARRONAX beamline, which can lead to significant biases in the observed biological results and dose-response relationships, as for any facility. This paper summarizes and quantifies the impact of uncertainty on proton range, absorbed dose, and dose homogeneity in a preclinical context of cell or small animal irradiation on the Bragg curve, using Monte Carlo simulations. All possible sources of uncertainty were investigated and discussed independently. Those with a significant impact were identified, and protocols were established to reduce their consequences. Overall, the uncertainties evaluated were similar to those from clinical practice and are considered compatible with the performance of radiobiological experiments, as well as the study of dose-response relationships on this proton beam. Another conclusion of this study is that Monte Carlo simulations can be used to help build preclinical lines in other setups.

11.
Clin Nucl Med ; 45(9): e403-e405, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32657871

RESUMO

Radiation pneumonitis (RP) can be an adverse complication of radiotherapy and usually occurs as an acute reaction from 6 to 12 weeks after radiotherapy. FDG PET is described as an early and adequate barometer for RP diagnosis. Only 1 case of fluoroestradiol uptake contemporary of metabolic FDG changes attributed to RP is reported. We report a case of a breast cancer patient with asymptomatic RP, who at 1 year later, at sequelar stage on CT, showed long-term memory of RP by F-fluoroestradiol PET imaging with nonmetabolic FDG PET.


Assuntos
Estradiol/análogos & derivados , Radioisótopos de Flúor , Tomografia por Emissão de Pósitrons , Pneumonite por Radiação/diagnóstico por imagem , Doenças Assintomáticas , Neoplasias da Mama/radioterapia , Feminino , Humanos
12.
Cancer Res ; 80(12): 2651-2662, 2020 06 15.
Artigo em Inglês | MEDLINE | ID: mdl-32291318

RESUMO

Ceramide-induced endothelial cell apoptosis boosts intestinal stem cell radiosensitivity. However, the molecular connection between these two cellular compartments has not been clearly elucidated. Here we report that ceramide and its related enzyme acid sphingomyelinase (ASM) are secreted by irradiated endothelial cells and act as bystander factors to enhance the radiotoxicity of intestinal epithelium. Ceramide and the two isoforms of ASM were acutely secreted in the blood serum of wild-type mice after 15 Gy radiation dose, inducing a gastrointestinal syndrome. Interestingly, serum ceramide was not enhanced in irradiated ASMKO mice, which are unable to develop intestinal failure injury. Because ASM/ceramide were secreted by primary endothelial cells, their contribution was studied in intestinal epithelium dysfunction using coculture of primary endothelial cells and intestinal T84 cells. Adding exogenous ASM or ceramide enhanced epithelial cell growth arrest and death. Conversely, blocking their secretion by endothelial cells using genetic, pharmacologic, or immunologic approaches abolished intestinal T84 cell radiosensitivity. Use of enteroid models revealed ASM and ceramide-mediated deleterious mode-of-action: when ceramide reduced the number of intestinal crypt-forming enteroids without affecting their structure, ASM induced a significant decrease of enteroid growth without affecting their number. Identification of specific and different roles for ceramide and ASM secreted by irradiated endothelial cells opens new perspectives in the understanding of intestinal epithelial dysfunction after radiation and defines a new class of potential therapeutic radiomitigators. SIGNIFICANCE: This study identifies secreted ASM and ceramide as paracrine factors enhancing intestinal epithelial dysfunction, revealing a previously unknown class of mediators of radiosensitivity.


Assuntos
Ceramidas/metabolismo , Células Endoteliais/metabolismo , Mucosa Intestinal/patologia , Lesões por Radiação/patologia , Esfingomielina Fosfodiesterase/metabolismo , Animais , Efeito Espectador/efeitos da radiação , Células Cultivadas , Ceramidas/sangue , Técnicas de Cocultura , Desipramina/farmacologia , Modelos Animais de Doenças , Células Endoteliais/efeitos dos fármacos , Células Endoteliais/efeitos da radiação , Células Epiteliais/efeitos dos fármacos , Células Epiteliais/patologia , Células Epiteliais/efeitos da radiação , Humanos , Mucosa Intestinal/citologia , Mucosa Intestinal/efeitos dos fármacos , Mucosa Intestinal/efeitos da radiação , Masculino , Camundongos , Camundongos Knockout , Comunicação Parácrina/genética , Comunicação Parácrina/efeitos da radiação , Cultura Primária de Células , RNA Interferente Pequeno/metabolismo , Lesões por Radiação/sangue , Lesões por Radiação/etiologia , Lesões por Radiação/prevenção & controle , Tolerância a Radiação/efeitos dos fármacos , Tolerância a Radiação/genética , Esfingomielina Fosfodiesterase/antagonistas & inibidores , Esfingomielina Fosfodiesterase/sangue , Esfingomielina Fosfodiesterase/genética
13.
FASEB J ; 34(4): 4984-4996, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-32043634

RESUMO

Engaging in exercise while undergoing radiotherapy (RT) has been reported to be safe and achievable. The impact of exercise training (ET) on RT efficiency is however largely unknown. Our study aims to investigate the interactions between ET and RT on prostate cancer growth. Athymic mice received a subcutaneous injection of PPC-1 cells and were randomly assigned to either cancer control, cancer ET, cancer RT, or cancer RT combined with ET (CaRT-ET). Mice were sacrificed 24 days post-injection. All three intervention groups had reduced tumor size, the most important decrease being observed in CaRT-ET mice. Apoptotic marker cleaved caspase-3 was not modified by ET, but enhanced with RT. Importantly, this increase was the highest when the two strategies were combined. Furthermore, NK1.1 staining and gene expression of natural killer (NK) cell receptors Klrk1 and Il2rß were not affected by ET alone but were increased with RT, this effect being potentiated when combined with ET. Overall, our study shows that (a) ET enhances RT efficiency by potentiating NK cell infiltration, and (b) while ET alone and ET combined with RT both reduce tumor growth, the mechanisms mediating these effects are different.


Assuntos
Condicionamento Físico Animal/métodos , Neoplasias da Próstata/radioterapia , Radioterapia/métodos , Animais , Antígenos Ly/genética , Antígenos Ly/metabolismo , Apoptose , Caspase 3/genética , Caspase 3/metabolismo , Linhagem Celular Tumoral , Terapia Combinada , Humanos , Subunidade beta de Receptor de Interleucina-2/genética , Subunidade beta de Receptor de Interleucina-2/metabolismo , Masculino , Camundongos , Subfamília B de Receptores Semelhantes a Lectina de Células NK/genética , Subfamília B de Receptores Semelhantes a Lectina de Células NK/metabolismo , Subfamília K de Receptores Semelhantes a Lectina de Células NK/genética , Subfamília K de Receptores Semelhantes a Lectina de Células NK/metabolismo , Neoplasias da Próstata/metabolismo , Neoplasias da Próstata/terapia
14.
Cancers (Basel) ; 12(1)2020 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-31906502

RESUMO

Background. The tumor vasculature acts as an interface for the primary tumor. It regulates oxygenation, nutrient delivery, and treatment efficacy including radiotherapy. The response of the tumor vasculature to different radiation doses has been disparately reported. Whereas high single doses can induce endothelial cell death, improved vascular functionality has also been described in a various dose range, and few attempts have been made to reconcile these findings. Therefore, we aimed at comparing the effects of different radiation fractionation regimens on the tumor vascular microenvironment. METHODS: Lewis lung and prostate PC3 carcinoma-derived tumors were irradiated with regimens of 10 × 2 Gy, 6 × 4 Gy, 3 × 8 Gy or 2 × 12 Gy fractions. The tumor vasculature phenotype and function was evaluated by immunohistochemistry for endothelial cells (CD31), pericytes (desmin, α-SMA), hypoxia (pimonidazole) and perfusion (Hoechst 33342). RESULTS: Radiotherapy increased vascular coverage similarly in all fractionation regimens in both models. Vessel density appeared unaffected. In PC3 tumors, hypoxia was decreased and perfusion was enhanced in proportion with the dose per fraction. In LLC tumors, no functional changes were observed at t = 15 days, but increased perfusion was noticed earlier (t = 9-11 days). CONCLUSION: The vascular microenvironment response of prostate and lung cancers to radiotherapy consists of both tumor/dose-independent vascular maturation and tumor-dependent functional parameters.

15.
Br J Radiol ; 92(1102): 20190270, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31295002

RESUMO

Modulated radiotherapy with multileaf collimators is widely used to improve target conformity and normal tissue sparing. This introduced an additional degree of complexity, studied by multiple teams through different properties. Three categories of complexity metrics were considered in this review: fluence, deliverability and accuracy metrics. The first part of this review is dedicated to the inventory of these complexity metrics. Different applications of these metrics emerged. Influencing the optimizer by integrating complexity metrics into the cost function has been little explored and requires more investigations. In modern treatment planning system, it remains confined to MUs or treatment time limitation. A large majority of studies calculated metrics only for analysis, without plan modification. The main application was to streamline the patient specific quality assurance workload, investigating the capability of complexity metrics to predict patient specific quality assurance results. Additionally complexity metrics were used to analyze behaviour of TPS optimizer, compare TPS, operators and plan properties, and perform multicentre audit. Their potential was also explored in the context of adaptive radiotherapy and automation planning. The second part of the review gives an overview of these studies based on the complexity metrics.


Assuntos
Garantia da Qualidade dos Cuidados de Saúde , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Humanos , Planejamento da Radioterapia Assistida por Computador/normas , Radioterapia de Intensidade Modulada/normas
16.
Cancer Lett ; 457: 1-9, 2019 08 10.
Artigo em Inglês | MEDLINE | ID: mdl-31078733

RESUMO

The tumor microenvironment regulates cancer initiation, progression and response to treatment. In particular, the immature tumor vasculature may impede drugs from reaching tumor cells at a lethal concentration. We and others have shown that radiation therapy (RT) induces pericyte recruitment, resembling vascular normalization. Here, we asked whether radiation-induced vascular remodeling translates into improved tissue distribution and efficacy of chemotherapy. First, RT induced vascular remodeling, accompanied by decreased hypoxia and/or increased Hoechst perfusion in prostate PC3 and LNCaP and Lewis lung carcinoma. These results were independent of the RT regimen, respectively 10 × 2 Gy and 2 × 12 Gy, suggesting a common effect. Next, using doxorubicin as a fluorescent reporter, we observed that RT improves intra-tumoral chemotherapy distribution. These effects were not hindered by anti-angiogenic sunitinib. Moreover, sub-optimal doses of doxorubicin had almost no effect alone, but significantly delayed tumor growth after RT. These data demonstrate that RT favors the efficacy of chemotherapy by improving tissue distribution, and could be an alternative chemosensitizing strategy.


Assuntos
Antibióticos Antineoplásicos/farmacologia , Carcinoma Pulmonar de Lewis/irrigação sanguínea , Carcinoma Pulmonar de Lewis/terapia , Quimiorradioterapia , Doxorrubicina/farmacologia , Neoplasias da Próstata/irrigação sanguínea , Neoplasias da Próstata/terapia , Doses de Radiação , Remodelação Vascular/efeitos da radiação , Animais , Antibióticos Antineoplásicos/metabolismo , Carcinoma Pulmonar de Lewis/metabolismo , Carcinoma Pulmonar de Lewis/patologia , Doxorrubicina/metabolismo , Feminino , Humanos , Masculino , Camundongos Endogâmicos C57BL , Camundongos Nus , Neovascularização Patológica , Células PC-3 , Neoplasias da Próstata/metabolismo , Neoplasias da Próstata/patologia , Distribuição Tecidual , Carga Tumoral/efeitos dos fármacos , Carga Tumoral/efeitos da radiação , Hipóxia Tumoral , Microambiente Tumoral , Ensaios Antitumorais Modelo de Xenoenxerto
17.
Int J Radiat Oncol Biol Phys ; 104(2): 343-354, 2019 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-30716523

RESUMO

PURPOSE: To apply a voxel-based analysis to identify urethrovesical symptom-related subregions (SRSs) associated with acute and late urinary toxicity in prostate cancer radiation therapy. METHODS AND MATERIALS: Two hundred seventy-two patients with prostate cancer treated with intensity-modulated radiation therapy/image-guided radiation therapy were analyzed prospectively. Each patient's computed tomography imaging was spatially normalized to a common coordinate system via nonrigid registration. The obtained deformation fields were used to map the dose of each patient to the common coordinate system. A voxel-based statistical analysis was applied to generate 3-dimensional dose-volume maps for different urinary symptoms, allowing the identification of corresponding SRSs with statistically significant dose differences between patients with or without toxicity. Each SRS was propagated back to each individual's native space, and dose-volume histograms (DVHs) for the SRSs and the whole bladder were computed. Logistic and Cox regression were used to estimate the SRS's prediction capability compared with the whole bladder. RESULTS: A local dose-effect relationship was found in the bladder and the urethra. SRSs were identified for 5 symptoms: acute incontinence in the urethra, acute retention in the bladder trigone, late retention and dysuria in the posterior part of the bladder, and late hematuria in the superior part of the bladder, with significant dose differences between patients with and without toxicity, ranging from 1.2 to 9.3 Gy. The doses to the SRSs were significantly predictive of toxicity, with maximum areas under the receiver operating characteristic curve of 0.73 for acute incontinence, 0.62 for acute retention, 0.70 for late retention, 0.81 for late dysuria, and 0.67 for late hematuria. The bladder DVH was predictive only for late retention, dysuria, and hematuria (area under the curve, 0.65-0.72). CONCLUSIONS: The dose delivered to the urethra and the posterior and superior parts of the bladder was predictive of acute incontinence and retention and of late retention, dysuria, and hematuria. The dose to the whole bladder was moderately predictive.


Assuntos
Gráficos por Computador , Neoplasias da Próstata/radioterapia , Radioterapia Guiada por Imagem/efeitos adversos , Radioterapia de Intensidade Modulada/efeitos adversos , Uretra/diagnóstico por imagem , Bexiga Urinária/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Disuria/diagnóstico por imagem , Hematúria/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Lesões por Radiação/diagnóstico por imagem , Radioterapia Guiada por Imagem/métodos , Radioterapia de Intensidade Modulada/métodos , Análise de Regressão , Uretra/efeitos da radiação , Bexiga Urinária/efeitos da radiação , Incontinência Urinária/diagnóstico por imagem , Retenção Urinária/diagnóstico por imagem
18.
Sci Rep ; 7(1): 2280, 2017 05 23.
Artigo em Inglês | MEDLINE | ID: mdl-28536438

RESUMO

The concept of hypofractionation is gaining momentum in radiation oncology centres, enabled by recent advances in radiotherapy apparatus. The gain of efficacy of this innovative treatment must be defined. We present a computer model based on translational murine data for in silico testing and optimization of various radiotherapy protocols with respect to tumour resistance and the microenvironment heterogeneity. This model combines automata approaches with image processing algorithms to simulate the cellular response of tumours exposed to ionizing radiation, modelling the alteration of oxygen permeabilization in blood vessels against repeated doses, and introducing mitotic catastrophe (as opposed to arbitrary delayed cell-death) as a means of modelling radiation-induced cell death. Published data describing cell death in vitro as well as tumour oxygenation in vivo are used to inform parameters. Our model is validated by comparing simulations to in vivo data obtained from the radiation treatment of mice transplanted with human prostate tumours. We then predict the efficacy of untested hypofractionation protocols, hypothesizing that tumour control can be optimized by adjusting daily radiation dosage as a function of the degree of hypoxia in the tumour environment. Further biological refinement of this tool will permit the rapid development of more sophisticated strategies for radiotherapy.


Assuntos
Oxigênio/metabolismo , Neoplasias da Próstata/radioterapia , Radioterapia/métodos , Ensaios Antitumorais Modelo de Xenoenxerto , Algoritmos , Animais , Morte Celular/efeitos da radiação , Simulação por Computador , Difusão , Humanos , Masculino , Camundongos , Modelos Biológicos , Células PC-3 , Neoplasias da Próstata/patologia , Carga Tumoral/efeitos da radiação
19.
Phys Med ; 32(5): 664-70, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-27132030

RESUMO

PURPOSE: Static beam intensity-modulated-radiation-therapy (IMRT) and/or Volumetric-Modulated-Arc-Therapy (VMAT) are now available in many regional radiotherapy departments. The aim of this multi-institutional audit was to design a new methodology based on radiochromic films to perform an independent quality control. METHODS: A set of data were sent to all participating centres for two clinical localizations: prostate and Head and Neck (H&N) cancers. The agreement between calculations and measurements was verified in the Octavius phantom (PTW) by point measurements using ionization chambers and by 2D measurements using EBT3 radiochromic films. Due to uncertainties in the whole procedure, criteria were set to 5% and 3% in local dose and 3mm in distance excluding doses lower than 10% of the maximum doses. No normalization point or area was used for the quantitative analysis. RESULTS: 13 radiotherapy centres participated in this audit involving 28 plans (12 IMRT, 16 VMAT). For point measurements, mean errors were -0.18±1.54% and 0.00±1.58% for prostate and H&N cases respectively. For 2D measurements with 5%/3mm criteria, gamma map analysis showed a pixel pass rate higher than 95% for prostate and H&N. Mean gamma index was lower than 0.4 for prostate and 0.5 for H&N. Both techniques yielded similar results. CONCLUSION: This study showed the feasibility of an independent quality control by peers for conventional IMRT and VMAT. Results from all participating centres were found to be in good agreement. This regional study demonstrated the feasibility of our new methodology based on radiochromic films without dose normalization on a specific point.


Assuntos
Neoplasias de Cabeça e Pescoço/radioterapia , Neoplasias da Próstata/radioterapia , Radioterapia de Intensidade Modulada/métodos , Radioterapia/métodos , Calibragem , Dosimetria Fotográfica , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Imagens de Fantasmas , Controle de Qualidade , Radiometria , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Rotação
20.
Front Oncol ; 5: 204, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26442216

RESUMO

BACKGROUND: Surgery plus adjuvant radiotherapy is standard care for locally advanced prostate cancer (stage pT3R1). Intraoperative low-energy photon radiotherapy offers several advantages over external beam radiotherapy, and several systems are now available for its delivery, using spherical applicators, which require only limited shielding. The aim of this study was to evaluate the feasibility of this technique for the prostate bed. MATERIALS AND METHODS: Applicators were assessed using MRI image data and cadaveric dissection. In cadavers, targeted tissues, defined as a urethral section, both neurovascular bundle sections, the bladder neck and the beds of the seminal vesicles, were marked with metallic surgical clips. Distances between clips and applicator were measured using CT. A dosimetric study of the application of 12 Gy at 5 mm depth was performed using CT images of prostatectomized cadavers. RESULTS: Using MRI images from 34 prostate cancer patients, we showed that the ideal applicator diameter ranges from 45 to 70 mm. Using applicators of different sizes to encompass the prostate bed in nine cadavers, we showed that the distance between target tissues and applicator was <2 mm for all target tissues except the upper extremity of the seminal vesicles (19 mm). Dosimetric study showed a good dose distribution in all target tissues in contact with the applicator, with a low probability of rectum and bladder complication. CONCLUSION: Intraoperative radiotherapy of the prostate bed is feasible, with good coverage of targeted tissues. Clinical study of safety and efficacy is now required.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...