Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
3.
JACC Clin Electrophysiol ; 9(8 Pt 3): 1719-1729, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37227359

RESUMO

BACKGROUND: Multiple cardiac sarcoidosis (CS) diagnostic schemes have been published. OBJECTIVES: This study aims to evaluate the association of different CS diagnostic schemes with adverse outcomes. The diagnostic schemes evaluated were 1993, 2006, and 2017 Japanese criteria and the 2014 Heart Rhythm Society criteria. METHODS: Data were collected from the Cardiac Sarcoidosis Consortium, an international registry of CS patients. Outcome events were any of the following: all-cause mortality, left ventricular assist device placement, heart transplantation, and appropriate implantable cardioverter-defibrillator therapy. Logistic regression analysis evaluated the association of outcomes with each CS diagnostic scheme. RESULTS: A total of 587 subjects met the following criteria: 1993 Japanese (n = 310, 52.8%), 2006 Japanese (n = 312, 53.2%), 2014 Heart Rhythm Society (n = 480, 81.8%), and 2017 Japanese (n = 112, 19.1%). Patients who met the 1993 criteria were more likely to experience an event than patients who did not (n = 109 of 310, 35.2% vs n = 59 of 277, 21.3%; OR: 2.00; 95% CI: 1.38-2.90; P < 0.001). Similarly, patients who met the 2006 criteria were more likely to have an event than patients who did not (n = 116 of 312, 37.2% vs n = 52 of 275, 18.9%; OR: 2.54; 95% CI: 1.74-3.71; P < 0.001). There was no statistically significant association between the occurrence of an event and whether a patient met the 2014 or the 2017 criteria (OR: 1.39; 95% CI: 0.85-2.27; P = 0.18 or OR: 1.51; 95% CI: 0.97-2.33; P = 0.067, respectively). CONCLUSIONS: CS patients who met the 1993 and the 2006 criteria had higher odds of adverse clinical outcomes. Future research is needed to prospectively evaluate existing diagnostic schemes and develop new risk models for this complex disease.


Assuntos
Cardiomiopatias , Desfibriladores Implantáveis , Transplante de Coração , Miocardite , Sarcoidose , Humanos , Sarcoidose/diagnóstico , Sarcoidose/epidemiologia , Sarcoidose/complicações , Desfibriladores Implantáveis/efeitos adversos
4.
J Interv Card Electrophysiol ; 66(8): 1859-1865, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36754907

RESUMO

BACKGROUND: To date, few risk models have been validated to predict recurrent atrial fibrillation (AF) >1 year after ablation. The SCALE-CryoAF score was previously derived to predict very late return of AF (VLRAF) >1 year following cryoballoon ablation (CBA), with strong predictive ability. In this study, we aim to validate the SCALE-CryoAF score for VLRAF after CBA in a novel patient cohort. METHODS: Retrospective analysis of a prospectively maintained single-center database was performed. Inclusion criteria were pulmonary vein isolation using CBA 2017-2020. Exclusion criteria included prior ablation, <1-year follow-up, lack of pre-CBA echocardiogram, additional ablation lesion sets, and documented AF recurrence 90-365 days post-CBA. The area under the curve (AUC) of SCALE-CryoAF was compared to the derivation value and other established risk models. RESULTS: Among 469 CBA performed, 241 (61% male, 62.8 ±11.7 years old) cases were included in analysis. There were 37 (15.4%) patients who developed VLRAF. Patients with VLRAF had a higher SCALE-CryoAF score (VLRAF 5.4 ± 2.7; no VLRAF 3.1 ± 2.9; p<0.001). SCALE-CryoAF was linearly associated with VLRAF (y=14.35x-11.72, R2=0.99), and a score > 5 had a 32.7% risk of VLRAF. The SCALE-CryoAF risk model predicted VLRAF with an AUC of 0.74, which was similar to the derivation value (AUCderivation: 0.73) and statistically superior to MB-LATER, CHA2DS2-VASc, and CHADS2 scores. CONCLUSIONS: The current analysis validates the ability of SCALE-CryoAF to predict VLRAF after CBA in a novel patient cohort. Patients with a high SCALE-CryoAF score should be monitored closely for recurrent AF >1 year following CBA.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Feminino , Fibrilação Atrial/cirurgia , Resultado do Tratamento , Estudos Retrospectivos , Fatores de Risco , Ecocardiografia , Recidiva , Veias Pulmonares/cirurgia
5.
J Cardiovasc Electrophysiol ; 33(12): 2560-2566, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36317453

RESUMO

INTRODUCTION: Esophageal thermal injury (ETI) is a well-recognized complication of atrial fibrillation (AF) ablation. Previous studies have demonstrated that direct esophageal cooling reduces ETI during radiofrequency AF ablation. The purpose of this study was to evaluate the use of an esophageal warming device to prevent ETI during cryoballoon ablation (CBA) for AF. METHODS: This prospective, double-blinded study enrolled 42 patients with symptomatic AF undergoing CBA. Patients were randomized to the treatment group with esophageal warming (42°C) using recirculated water through a multilumen, silicone tube inserted into the esophagus (EnsoETM®; Attune Medical) (WRM) or the control group with a luminal single-electrode esophageal temperature monitoring probe (LET). Patients underwent upper endoscopy esophagogastroduodenoscopy (EGD) the following day. ETI was classified into four grades. RESULTS: Baseline patient characteristics were similar between groups. Procedural characteristics including number of freezes, total freeze time, early freeze terminations, coldest balloon temperature, procedure duration, posterior wall ablation, and proton pump inhibitor and transesophageal echocardiogram use before procedure were not different between groups. The EGD was completed in 40/42 patients. There was significantly more ETI in the WRM group compared to the LET group (n = 8 [38%] vs. n = 1 [5%], p = 0.02). All ETI lesions were grade 1 (erythema) or 2 (superficial ulceration). Total freeze time in the left inferior pulmonary vein was predictive of ETI (360 vs. 300 s, p = 0.03). CONCLUSION: Use of a luminal heat exchange tube for esophageal warming during CBA for AF was paradoxically associated with a higher risk of ETI.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Estudos Prospectivos , Temperatura , Ablação por Cateter/métodos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Criocirurgia/efeitos adversos
6.
Eur Heart J ; 43(47): 4872-4883, 2022 12 14.
Artigo em Inglês | MEDLINE | ID: mdl-36030464

RESUMO

BACKGROUND: The subcutaneous implantable cardioverter-defibrillator (S-ICD) is developed to overcome lead-related complications and systemic infections, inherent to transvenous ICD (TV-ICD) therapy. The PRAETORIAN trial demonstrated that the S-ICD is non-inferior to the TV-ICD with regard to the combined primary endpoint of inappropriate shocks and complications. This prespecified secondary analysis evaluates all complications in the PRAETORIAN trial. METHODS AND RESULTS: The PRAETORIAN trial is an international, multicentre, randomized trial in which 849 patients with an indication for ICD therapy were randomized to receive an S- ICD (N = 426) or TV-ICD (N = 423) and followed for a median of 49 months. Endpoints were device-related complications, lead-related complications, systemic infections, and the need for invasive interventions. Thirty-six device-related complications occurred in 31 patients in the S-ICD group of which bleedings were the most frequent. In the TV-ICD group, 49 complications occurred in 44 patients of which lead dysfunction was most frequent (HR: 0.69; P = 0.11). In both groups, half of all complications were within 30 days after implantation. Lead-related complications and systemic infections occurred significantly less in the S-ICD group compared with the TV-ICD group (P < 0.001, P = 0.03, respectively). Significantly more complications required invasive interventions in the TV-ICD group compared with the S-ICD group (8.3% vs. 4.3%, HR: 0.59; P = 0.047). CONCLUSION: This secondary analysis shows that lead-related complications and systemic infections are more prevalent in the TV-ICD group compared with the S-ICD group. In addition, complications in the TV-ICD group were more severe as they required significantly more invasive interventions. This data contributes to shared decision-making in clinical practice.


Assuntos
Morte Súbita Cardíaca , Desfibriladores Implantáveis , Humanos , Resultado do Tratamento , Desfibriladores Implantáveis/efeitos adversos
8.
Cardiol J ; 29(2): 272-283, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-32378730

RESUMO

BACKGROUND: Cardiac autonomic neuropathy (CAN) is a complication of diabetes mellitus (DM) that is associated with increased mortality. Exercise-based assessment of autonomic function has identified diminished parasympathetic reactivation after exercise in type 2 DM. It is postulated herein, that this would be more prominent among those with type 1 DM. METHODS: Sixteen subjects with type 1 DM (age 32.9 ± 10.1 years), 18 subjects with type 2 DM (55.4 ± 8.0 years) and 30 controls (44.0 ± 11.6 years) underwent exercise-based assessment of autonomic function. Two 16-min submaximal bicycle tests were performed followed by 45 min of recovery. On the second test, atropine (0.04 mg/kg) was administered near end-exercise so that all of the recovery occurred under parasympathetic blockade. Plasma epinephrine and norepinephrine levels were measured at rest, during exercise, and during recovery. RESULTS: There were no differences in resting or end-exercise heart rates in the three groups. Parasympathetic effect on RR-intervals during recovery (p < 0.03) and heart rate recovery (p = 0.02) were blunted in type 2 DM. Type 1 DM had higher baseline epinephrine and norepinephrine levels (p < 0.03), and exhibited persistent sympathoexcitation during recovery. CONCLUSIONS: Despite a longer duration of DM in the study patients with type 1 versus type 2 DM, diminished parasympathetic reactivation was not noted in type 1 DM. Instead, elevation in resting plasma catecholamines was noted compared to type 2 DM and controls. The variable pathophysiology for exercise-induced autonomic abnormalities in type 1 versus type 2 DM may impact prognosis.


Assuntos
Diabetes Mellitus Tipo 2 , Adulto , Sistema Nervoso Autônomo , Diabetes Mellitus Tipo 2/complicações , Diabetes Mellitus Tipo 2/diagnóstico , Epinefrina/farmacologia , Exercício Físico/fisiologia , Teste de Esforço , Frequência Cardíaca/fisiologia , Humanos , Norepinefrina/farmacologia , Adulto Jovem
9.
Circulation ; 145(5): 321-329, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34779221

RESUMO

BACKGROUND: The PRAETORIAN trial (A Prospective, Randomized Comparison of Subcutaneous and Transvenous Implantable Cardioverter Defibrillator Therapy) showed noninferiority of subcutaneous implantable cardioverter defibrillator (S-ICD) compared with transvenous implantable cardioverter defibrillator (TV-ICD) with regard to inappropriate shocks and complications. In contrast to TV-ICD, S-ICD cannot provide antitachycardia pacing for monomorphic ventricular tachycardia. This prespecified secondary analysis evaluates appropriate therapy and whether antitachycardia pacing reduces the number of appropriate shocks. METHODS: The PRAETORIAN trial was an international, investigator-initiated randomized trial that included patients with an indication for implantable cardioverter defibrillator (ICD) therapy. Patients with previous ventricular tachycardia <170 bpm or refractory recurrent monomorphic ventricular tachycardia were excluded. In 39 centers, 849 patients were randomized to receive an S-ICD (n=426) or TV-ICD (n=423) and were followed for a median of 49.1 months. ICD programming was mandated by protocol. Appropriate ICD therapy was defined as therapy for ventricular arrhythmias. Arrhythmias were classified as discrete episodes and storm episodes (≥3 episodes within 24 hours). Analyses were performed in the modified intention-to-treat population. RESULTS: In the S-ICD group, 86 of 426 patients received appropriate therapy, versus 78 of 423 patients in the TV-ICD group, during a median follow-up of 52 months (48-month Kaplan-Meier estimates 19.4% and 17.5%; P=0.45). In the S-ICD group, 83 patients received at least 1 shock, versus 57 patients in the TV-ICD group (48-month Kaplan-Meier estimates 19.2% and 11.5%; P=0.02). Patients in the S-ICD group had a total of 254 shocks, compared with 228 shocks in the TV-ICD group (P=0.68). First shock efficacy was 93.8% in the S-ICD group and 91.6% in the TV-ICD group (P=0.40). The first antitachycardia pacing attempt successfully terminated 46% of all monomorphic ventricular tachycardias, but accelerated the arrhythmia in 9.4%. Ten patients with S-ICD experienced 13 electrical storms, versus 18 patients with TV-ICD with 19 electrical storms. Patients with appropriate therapy had an almost 2-fold increased relative risk of electrical storms in the TV-ICD group compared with the S-ICD group (P=0.05). CONCLUSIONS: In this trial, no difference was observed in shock efficacy of S-ICD compared with TV-ICD. Although patients in the S-ICD group were more likely to receive an ICD shock, the total number of appropriate shocks was not different between the 2 groups. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT01296022.


Assuntos
Arritmias Cardíacas/terapia , Desfibriladores Implantáveis/normas , Idoso , Arritmias Cardíacas/diagnóstico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento
10.
JAMA Cardiol ; 7(2): 175-183, 2022 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-34787643

RESUMO

Importance: Ventricular tachycardia (VT) is associated with high mortality in patients with cardiac sarcoidosis (CS), and medical management of CS-associated VT is limited by high failure rates. The role of catheter ablation has been investigated in small, single-center studies. Objective: To investigate outcomes associated with VT ablation in patients with CS. Design, Setting, and Participants: This cohort study from the Cardiac Sarcoidosis Consortium registry (2003-2019) included 16 tertiary referral centers in the US, Europe, and Asia. A total of 158 consecutive patients with CS and VT were included (33% female; mean [SD] age, 52 [11] years; 53% with ejection fraction [EF] <50%). Exposures: Catheter ablation of CS-associated VT and, as appropriate, medical treatment. Main Outcomes and Measures: Immediate and short-term outcomes included procedural success, elimination of VT storm, and reduction in defibrillator shocks. The primary long-term outcome was the composite of VT recurrence, heart transplant (HT), or death. Results: Complete procedural success (no inducible VT postablation) was achieved in 85 patients (54%). Sixty-five patients (41%) had preablation VT storm that did not recur postablation in 53 (82%). Defibrillator shocks were significantly reduced from a median (IQR) of 2 (1-5) to 0 (0-0) in the 30 days before and after ablation (P < .001). During median (IQR) follow-up of 2.5 (1.1-4.9) years, 73 patients (46%) experienced VT recurrence and 81 (51%) experienced the composite primary outcome. One- and 2-year rates of survival free of VT recurrence, HT, or death were 60% and 52%, respectively. EF less than 50% and myocardial inflammation on preprocedural 18F-fluorodeoxyglucose positron emission tomography were significantly associated with adverse prognosis in multivariable analysis for the primary outcome (HR, 2.24; 95% CI, 1.37-3.64; P = .001 and HR, 2.93; 95% CI, 1.31-6.55; P = .009, respectively). History of hypertension was associated with a favorable long-term outcome (adjusted HR, 0.51; 95% CI, 0.28-0.92; P = .02). Conclusions and Relevance: In this observational study of selected patients with CS and VT, catheter ablation was associated with reductions in defibrillator shocks and recurrent VT storm. Preablation LV dysfunction and myocardial inflammation were associated with adverse long-term prognosis. These data support the role of catheter ablation in conjunction with medical therapy in the management of CS-associated VT.


Assuntos
Antiarrítmicos/uso terapêutico , Cardiomiopatias/terapia , Ablação por Cateter , Morte Súbita Cardíaca/prevenção & controle , Sarcoidose/terapia , Taquicardia Ventricular/cirurgia , Adulto , Cardiomiopatias/complicações , Cardiomiopatias/diagnóstico por imagem , Cardiomiopatias/fisiopatologia , Desfibriladores Implantáveis , Cardioversão Elétrica/estatística & dados numéricos , Feminino , Fluordesoxiglucose F18 , Coração/diagnóstico por imagem , Transplante de Coração/estatística & dados numéricos , Humanos , Inflamação/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Mortalidade , Análise Multivariada , Miocárdio , Tomografia por Emissão de Pósitrons , Compostos Radiofarmacêuticos , Recidiva , Sarcoidose/complicações , Sarcoidose/diagnóstico por imagem , Sarcoidose/fisiopatologia , Volume Sistólico , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/fisiopatologia , Resultado do Tratamento
11.
J Cardiovasc Electrophysiol ; 32(8): 2097-2104, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34191371

RESUMO

INTRODUCTION: Obesity is an established risk factor for recurrent atrial fibrillation (AF) after ablation. The impact of pre-procedure weight changes on freedom from AF (FFAF) after ablation in obese and nonobese patients is unknown. METHODS: A single-center retrospective cohort study of patients undergoing pulmonary vein isolation was performed. Before ablation, all candidates were encouraged to adopt healthy lifestyle habits according to American Heart Association guidelines, including weight loss, by their physician. The primary endpoint was FFAF through 1-year after completion of the 3-month blanking period. RESULTS: Of the 601 patients (68% male; average age 62.1 ± 10.3 years) included in analysis, 234 patients (38.9%) were obese (body mass index ≥ 30) and 315 (52.4%) had paroxysmal AF. FFAF was observed in 420 patients (69.9%) at 15 months. Percent change in weight that occurred during the year before ablation independently predicted FFAF through 15-months in all patients (adjusted odds ratio = 1.17, 95% confidence interval: 1.11-1.23). Subgroup analyses based on paroxysmal vs persistent AF, presence of obesity, and history of prior ablation were performed. Percent change in weight over the year before ablation was independently associated with FFAF in all subgroups except nonobese patients with persistent AF. CONCLUSION: Pre-ablation weight loss was associated with FFAF in both obese and nonobese patients. Further studies are needed to define the optimal approach to weight loss before AF ablation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/cirurgia , Recidiva , Estudos Retrospectivos , Resultado do Tratamento , Redução de Peso
12.
J Interv Card Electrophysiol ; 60(3): 513-520, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32415554

RESUMO

PURPOSE: Patients with chronic kidney disease are predisposed to heart rhythm disorders including atrial fibrillation (AF). Several studies have suggested that radiofrequency catheter ablation of AF improves renal function. However, little data exists for pulmonary vein isolation with cryoballoon ablation (CBA). The purpose of this study is to assess change in renal function following CBA for AF. METHOD: This is a single-center retrospective study that included patients who underwent CBA for AF between 2011 and 2016. Patients were grouped by baseline-estimated glomerular filtration rate (eGFR): ≥ 90 (Stage G1), 60-89.9 (Stage G2), and 30-59.9 mL/min/1.73 m2 (Stage G3). Change in eGFR was assessed > 3 months post-ablation. RESULTS: A total of 306 patients with both pre- and post-ablation serum creatinine measurements available were included. Baseline eGFRs for Stages G1, G2, and G3 patients were 103.5 ± 12.9 (n = 82), 74.7 ± 8.2 (n = 184), and 52.6 ± 6.6 mL/min/1.73 m2 (n = 40), respectively. Renal function was assessed 310.8 ± 104.2 days post-ablation. Average intra-procedural contrast use was 58.4 ± 23.8 mL. There was no significant change in eGFR following CBA in Stage G1 patients (p = 0.10). For those with Stages G2 and G3 renal function, eGFR improved by 6.1% (4.2 mL/min/1.73 m2, p < 0.01) and 13.8% (7.2 mL/min/1.73 m2, p < 0.01), respectively. This improvement was seen regardless of the presence or absence of recurrent atrial arrhythmias. CONCLUSIONS: CBA for AF may be associated with an improvement in renal function, particularly among those with a reduced baseline eGFR despite recurrence of atrial arrhythmias and intra-procedural contrast use.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Humanos , Rim/diagnóstico por imagem , Rim/fisiologia , Rim/cirurgia , Recidiva , Estudos Retrospectivos , Resultado do Tratamento
14.
J Cardiovasc Electrophysiol ; 31(7): 1579-1584, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32400079

RESUMO

INTRODUCTION: Moderate sedation (MS) during cryoballoon ablation (CBA) avoids risks of general anesthesia (GA) and improves electrophysiology (EP) lab throughput. However, one barrier to the use of MS is the potential for patient discomfort. The objective of this study was to compare patient-reported outcome measures following CBA for paroxysmal atrial fibrillation (pAF) under MS and GA. METHODS AND RESULTS: Consecutive patients undergoing a first CBA for pAF under GA or MS were prospectively enrolled. The sedation method was assigned based on patient and provider preference, and perceived airway risk. The primary outcomes were quality of recovery (measured using a validated 40 question survey; QoR-40) and likelihood to recommend (LTR) the procedure and sedation method (measured by Likert scale). Secondary outcomes were acute pulmonary vein (PV) isolation rate, procedure, fluoroscopy and ablation times, and complication rates. Forty-seven GA and 53 MS patients were included. The mean age was 64.9 ± 9.4 years and mean CHA2 DS2 -VASc score was 2.0 ± 1.4. QoR-40 scores were 184.6 ± 16.4 for GA and 187.6 ± 10.2 for MS (P = .28). LTR responses were similar between groups. Mean procedure times were 148.2 ± 56.0 minutes for GA and 129.4 ± 31.4 minutes for MS (P = .038). Fluoroscopy and ablation times were similar between groups. A total of 100% (409/409) of PVs were acutely isolated. One hemopericardium occurred in the MS group requiring pericardiocentesis. CONCLUSION: MS for CBA offers an alternative to GA that is safe and well-tolerated by patients with comparable success rates and improved EP lab throughput.


Assuntos
Anestesia Geral , Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Medidas de Resultados Relatados pelo Paciente , Veias Pulmonares , Idoso , Anestesia Geral/efeitos adversos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Sedação Consciente/efeitos adversos , Criocirurgia/efeitos adversos , Humanos , Pessoa de Meia-Idade , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Resultado do Tratamento
15.
Circ Arrhythm Electrophysiol ; 13(5): e007853, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32286853

RESUMO

BACKGROUND: Nodoventricular and nodofascicular accessory pathways (AP) are uncommon connections between the atrioventricular node and the fascicles or ventricles. METHODS: Five patients with nodofascicular or nodoventricular tachycardia were studied. RESULTS: We identified 5 patients with concealed, left-sided nodoventricular (n=4), and nodofascicular (n=1) AP. We proved the participation of AP in tachycardia by delivering His-synchronous premature ventricular contractions that either delayed the subsequent atrial electrogram or terminated the tachycardia (n=3), and by observing an increase in VA interval coincident with left bundle branch block (n=2). The APs were not atrioventricular pathways because the septal VA interval during tachycardia was <70 ms in 3, 1 had spontaneous atrioventricular dissociation, and in 1 the atria were dissociated from the circuit with atrial overdrive pacing. Entrainment from the right ventricle showed ventricular fusion in 4 out of 5 cases. A left-sided origin of the AP was suspected after failed ablation of the right inferior extension of atrioventricular node in 3 cases and by observing a VA increase with left bundle branch block in 2 cases. The nodofascicular and 3 of the nodoventricular AP were successfully ablated from within the proximal coronary sinus (CS) guided by recorded potentials at the roof of the CS, and 1 nodoventricular AP was ablated via a transseptal approach near the CS os. CONCLUSIONS: Left-sided nodofascicular and nodoventricular AP appear to connect the ventricles with the CS musculature in the region of the CS os. Mapping and successful ablation sites can be guided by recording potentials within or near the CS os.


Assuntos
Feixe Acessório Atrioventricular/cirurgia , Ablação por Cateter , Frequência Cardíaca , Taquicardia Supraventricular/cirurgia , Feixe Acessório Atrioventricular/diagnóstico , Feixe Acessório Atrioventricular/fisiopatologia , Potenciais de Ação , Adulto , Ablação por Cateter/efeitos adversos , Técnicas Eletrofisiológicas Cardíacas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/fisiopatologia , Fatores de Tempo , Resultado do Tratamento
16.
J Cardiovasc Electrophysiol ; 31(5): 1031-1037, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32115794

RESUMO

INTRODUCTION: Focal impulse and rotor modulation (FIRM) ablation can be used to target nonpulmonary vein (PV) sources of atrial fibrillation (AF). No published studies have compared freedom from atrial fibrillation (FFAF) after pulmonary vein reisolation (PVRI) plus FIRM to PVRI alone in patients with reconnected PVs undergoing repeat ablation. METHODS: A 3:1 matched retrospective cohort study was performed on 21 patients with recurrent AF and PV reconnection who underwent PVRI plus FIRM-guided ablation and 63 patients with recurrent AF treated with PVRI alone at a single institution. All patients in the PVRI-alone cohort had cryoballoon PVRI at the time of repeat ablation without additional lesion sets for AF. Cases were matched based on the type of AF (paroxysmal vs nonparoxysmal), left atrial diameter (±4 mm), left ventricular ejection fraction (±10%), duration of AF (±18 months), and age (±5 years). The primary endpoint was FFAF after a 3-month blanking period. RESULTS: Out of 53 total FIRM cases performed at Northwestern Memorial Hospital between 2015 and 2017, 21 patients had PVRI plus FIRM for recurrent AF with PV reconnection. These patients had an average of 3.3 ± 2.1 rotors (60% left atrial) ablated. Over a median follow-up time of 24.7 months (interquartile range, 13-36 months), patients in the PVRI-alone cohort demonstrated a higher rate of FFAF (n = 35; 55.6%) than patients in the PVRI plus FIRM-guided ablation cohort (n = 7; 33.3%) (logrank P = .049). CONCLUSION: In patients undergoing repeat ablation for AF with PV reconnection, PVRI plus FIRM did not increase FFAF compared to PVRI alone.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Criocirurgia , Técnicas Eletrofisiológicas Cardíacas , Procedimento do Labirinto , Veias Pulmonares/cirurgia , Potenciais de Ação , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Criocirurgia/efeitos adversos , Bases de Dados Factuais , Feminino , Frequência Cardíaca , Humanos , Masculino , Procedimento do Labirinto/efeitos adversos , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Veias Pulmonares/fisiopatologia , Recidiva , Reoperação , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
17.
J Interv Card Electrophysiol ; 57(2): 233-240, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31102114

RESUMO

PURPOSE: Pulmonary vein isolation (PVI) by cryoballoon ablation (CBA) has emerged as a commonly used technique for the treatment of atrial fibrillation. We sought to explore the incidence, risk factors for, and characterization of post-CBA-PVI atrial flutter. METHODS: We analyzed a prospective registry of patients who underwent CBA-PVI at a single institution. We included patients with more than 3 months of follow-up data and excluded those with a history of cavotricuspid isthmus (CTI) ablation. Locations of post-CBA-PVI atrial flutters were determined by analysis of intracardiac electrograms and electroanatomic maps. RESULTS: There were 556 patients included in the analysis. The mean age was 61.0 ± 10.6 years, 67.4% were male, the number of failed anti-arrhythmic medication trials was 1.2 ± 0.8, and the duration of atrial fibrillation pre-CBA was 54.3 ± 69.1 months. The 28-mm second-generation cryoballoon was used almost exclusively. Over a median follow-up time of 22.7 ± 17.9 months, 25 (4.5%) patients developed post-CBA-PVI atrial flutter after the 3-month blanking period. Of those 25 patients, 15 (60%) underwent subsequent ablation to eliminate the atrial flutter circuit, with 60% being CTI-dependent and the remainder left-sided (p value not significant). Risk factors for the development of atrial flutter included NYHA class ≥ 2 (OR 5.02, p < 0.001), presence of baseline bundle branch block (OR 4.33, p = 0.006), and left ventricular ejection fraction < 50% (OR 3.36, p = 0.007). CONCLUSIONS: The rate of post-CBA-PVI atrial flutter is low after the blanking period even with medium-term follow-up. The origin of atrial flutter is equally divided between the right and left atria.


Assuntos
Fibrilação Atrial/cirurgia , Flutter Atrial/epidemiologia , Criocirurgia/métodos , Complicações Pós-Operatórias/epidemiologia , Veias Pulmonares/cirurgia , Eletrocardiografia , Técnicas Eletrofisiológicas Cardíacas , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Sistema de Registros , Estudos Retrospectivos
18.
J Interv Card Electrophysiol ; 58(2): 209-217, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31327104

RESUMO

PURPOSE: Cryoballoon ablation (CBA) is an effective technique for pulmonary vein isolation (PVI). To date, there are no risk models to predict very late recurrence of atrial fibrillation (VLRAF) after CBA. METHODS: Retrospective analysis of a single-center database was performed. Inclusion criteria included PVI using CBA for atrial fibrillation (AF) without additional ablation targets, follow-up > 365 days, and no recurrent AF between 90 and 365 days after procedure. The primary endpoint was recurrent AF > 30 s > 12 months post-CBA. A risk model was created using clinical variables. RESULTS: Of 674 CBA performed from 2011 to 2016, 300 patients (200 male, 62.0 ± 9.9 years) met inclusion criteria. Of these, 159 (53.0%) patients had paroxysmal AF. Patients had an average of 9.5 ± 2.7 cryoballoon freezes, and no patients required additional radiofrequency ablation lesion sets. Over a follow-up of 995 ± 490 days, 77/300 (25.7%) patients exhibited VLRAF. Univariate and multivariate analyses demonstrated that Structural heart disease (1 point), Coronary artery disease (3 points), left Atrial diameter > 43 mm (1 point), Left bundle branch block (3 points), Early return of AF (4 points), and non-paroxysmal AF (3 points) were risk factors for VLRAF. Combining these variables into a risk model, SCALE-CryoAF, (min 0; max 15) predicted VLRAF with an area under the curve of 0.73. CONCLUSION: SCALE-CryoAF is the first risk model to specifically predict first recurrence of AF beyond 1 year, VLRAF, after CBA. Model discrimination demonstrates that SCALE-CryoAF predicts VLRAF after CBA significantly better than other risk models for AF recurrence.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Humanos , Masculino , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Recidiva , Estudos Retrospectivos , Resultado do Tratamento
19.
Pacing Clin Electrophysiol ; 42(6): 694-704, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30912155

RESUMO

BACKGROUND: While several studies have evaluated predictors for atrial fibrillation (AF) recurrence following catheter ablation, there are limited data specific to cryoballoon ablation (CBA). METHODS: We analyzed a prospective registry of patients at a single institution who underwent CBA. Recurrence of AF (RAF) was defined as recurrence of AF by 12-month follow-up, excluding the 3-month blanking period. Univariate analysis was performed to evaluate predictors of RAF. Receiver operating characteristic analysis was used to compare and evaluate the performance of various risk scores for discriminating risk of RAF. RESULTS: There were 542 patients included in the analysis with mean age 61.3 ± 10.6 years, 67.9% male, and 51.6% paroxysmal AF (PAF). Overall, only left atrial diameter (LAD) > 40 mm and ERAF (early recurrence of AF within 0-3 month blanking period) were significant predictors of RAF. In the PAF specific subgroup, LAD > 40 mm, AF duration > 12 months, prior stroke or transient ischemic attack, ERAF, and having previously failed an antiarrhythmic drug were significant predictors of RAF. In persistent AF (PeAF) subgroup, obstructive sleep apnea (OSA) and ERAF were significant predictors of RAF. Out of clinical risk scores tested, BASEAF2 had the highest performance with area under the curve of 0.646 (95% confidence interval [0.548, 0.708]; P < .01). CONCLUSIONS: In this single-center retrospective study of CBA, we found only LAD > 40 mm and ERAF to be predictors of RAF. We identified OSA as a potential targetable risk factor in PeAF patients undergoing CBA. Out of risk scores tested for discriminating risk of RAF, BASEAF2 had the best performance.


Assuntos
Fibrilação Atrial/cirurgia , Criocirurgia/métodos , Idoso , Antiarrítmicos/administração & dosagem , Fibrilação Atrial/fisiopatologia , Feminino , Seguimentos , Humanos , Ataque Isquêmico Transitório/complicações , Masculino , Pessoa de Meia-Idade , Recidiva , Estudos Retrospectivos , Fatores de Risco , Apneia Obstrutiva do Sono/complicações , Acidente Vascular Cerebral/complicações , Fatores de Tempo
20.
Am J Cardiol ; 122(7): 1175-1178, 2018 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-30072132

RESUMO

The efficacy of novel oral anticoagulants (NOACs) in severely obese patients is uncertain as volume of distribution is related to weight, and few such patients were enrolled in the pivotal trials. As the month after direct-current cardioversion (DCCV) for atrial fibrillation and atrial flutter is a high-risk period for stroke, we sought to evaluate the safety of performing DCCV in obese patients on NOAC. All patients who underwent DCCV after ≥3 weeks of NOAC or therapeutic warfarin treatment without a previous transesophageal echocardiogram over a 3-year period at a single center were included. Obesity groups were defined as normal (body mass index [BMI] < 25), overweight (BMI 25 to <30), class 1 obesity (BMI 30 to <35), class 2 obesity (BMI 35 to <40), and class 3 or severe obesity (BMI ≥ 40). The primary end point was stroke at 30days. Of 761 patients, 73 were severely obese, 78 class 2 obese, 197 class 1 obese, 254 overweight, and 159 in the normal weight group. Average age 66.4 ± 10.3years and 32.5% women. Mean CHA2DS2-VASc score was 2.6 ± 1.6, and 78.9% were on NOACs with no differences in groups. There were no strokes in the severely obese group, and 1 each in class 2 obesity and normal weight (p = 0.3). In conclusion, there was a low rate of stroke in all weight classes after DCCV in patients taking NOACs and warfarin. NOAC use in severely obese patients who underwent DCCV appears safe even in the absence of transesophageal echocardiogram.


Assuntos
Anticoagulantes/administração & dosagem , Fibrilação Atrial/terapia , Flutter Atrial/terapia , Cardioversão Elétrica , Obesidade/complicações , Acidente Vascular Cerebral/prevenção & controle , Administração Oral , Idoso , Antiarrítmicos/administração & dosagem , Fibrilação Atrial/diagnóstico por imagem , Flutter Atrial/diagnóstico por imagem , Ecocardiografia Transesofagiana , Feminino , Humanos , Masculino , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...