1.
Am J Cardiol ; 112(6): 895-903, 2013 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-23756546

RESUMO

We tested the clinically relevant diagnostic accuracy of a new electrocardiographic (ECG) recording system incorporating all 10 ECG electrodes in a single-size glove worn on the patient's left arm and placed on the chest. The PhysioGlove (PG) was designed to allow fast, reproducible, electrode placement with only minimal training. The American College of Cardiology/American Heart Association ECG recording guidelines and others have repeatedly highlighted the unacceptable progressive deterioration in ECG accuracy mainly resulting from a performer's lack of proficiency and diligence, leading to frequent electrode misplacement. We studied 428 consenting adult patients with a broad spectrum of anthropomorphic characteristics and ECG and cardiovascular pathologic entities. The chest girth was measured to ascertain the single-size PG clinical diagnostic accuracy in ≥90% of this patient population. For each patient, a PG and standard-cable electrocardiogram were consecutively recorded and interpreted by experienced electrocardiographers. The study included 3 phases: phase 1, run-in (n = 120); phase 2, comparative diagnostic accuracy (n = 208); and phase 3, randomized, blinded, diagnostic accuracy (n = 100). Of the entire study population (n = 428), 92% fit the chest girth range of 85 to 118 cm (34 to 47 in.), representing the reference standard clinical diagnostic PG chest girth range. The phase 2 PG diagnostic accuracy was 91.3% for entire chest girth range and 95.7% for the 89.4% of patients with a chest girth within the reference range. The mean PG diagnostic accuracy in phase 3 was 93% (95% confidence interval 89% to 95%). In conclusion, compared with standard-cable electrocardiograms, the PG demonstrated excellent diagnostic accuracy (93% to 95.7%) in ≥90% of a typical western adult patient population. The PG's ease of use and minimal training requirements offer a promising tool to markedly improve ECG clinical diagnostic accuracy in most adult western patients.


Assuntos
Eletrocardiografia/métodos , Eletrocardiografia/normas , Eletrodos/normas , Cardiopatias/diagnóstico , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Diagnóstico Diferencial , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Índice de Gravidade de Doença , Adulto Jovem
2.
JACC Cardiovasc Imaging ; 2(7): 802-12, 2009 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19608128

RESUMO

OBJECTIVES: This study sought to establish normal values for real-time 3-dimensional echocardiography (RT3DE)-derived left ventricular (LV) dyssynchrony index (LVDI) and determine its age dependency, and to compare dyssynchrony in patients with normal LV function and patients with dilated cardiomyopathy (DCM), with and without left bundle branch block (LBBB). BACKGROUND: Cardiac resynchronization therapy is known to be ineffective in one-third of patients with heart failure, highlighting the need for alternative techniques to assess LV dyssynchrony. METHODS: Datasets from RT3DE were analyzed to calculate LVDI using 16- and 17-segment models. First, 135 normal subjects were studied to establish LVDI abnormality threshold (mean + 2 SD) and to study the relationship with age. Then, 3 groups of patients (N = 16 each: DCM with and without LBBB, normal LV function with LBBB) were compared with 50 age-matched normal control subjects. RESULTS: In normal subjects, the 16-segment model resulted in a lower LVDI abnormality threshold than the 17-segment model (4.0% vs. 4.5%). In patients with normal LV function, LVDI was significantly lower than in those with DCM, irrespective of LBBB. Although LBBB resulted in a nearly 2-fold increase in LVDI in patients with normal LV function, its effects were nonsignificant in DCM. All patients with DCM and ejection fraction <35% had abnormally high LVDI, likely as a result of low signal-to-noise ratio in low-amplitude regional volume curves hampering accurate determination of regional ejection time. CONCLUSIONS: Normal values established in this study resulted in indiscriminate diagnosis of abnormal dyssynchrony in all patients with reduced LV function. The value of RT3DE-derived LVDI in the evaluation of dyssynchrony in patients with reduced LV function needs to be critically reassessed because of the inability to accurately detect end-ejection in low-amplitude regional volume curves. Alternative indices of dyssynchrony need to be developed to address this limitation.


Assuntos
Bloqueio de Ramo/diagnóstico por imagem , Cardiomiopatia Dilatada/diagnóstico por imagem , Ecocardiografia Tridimensional , Interpretação de Imagem Assistida por Computador , Disfunção Ventricular Esquerda/diagnóstico por imagem , Adolescente , Adulto , Distribuição por Idade , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Bloqueio de Ramo/fisiopatologia , Bloqueio de Ramo/terapia , Cardiomiopatia Dilatada/fisiopatologia , Cardiomiopatia Dilatada/terapia , Estudos de Casos e Controles , Criança , Pré-Escolar , Cardioversão Elétrica , Feminino , Humanos , Técnicas In Vitro , Pessoa de Meia-Idade , Modelos Cardiovasculares , Variações Dependentes do Observador , Seleção de Pacientes , Valor Preditivo dos Testes , Estudos Prospectivos , Valores de Referência , Reprodutibilidade dos Testes , Fatores Sexuais , Volume Sistólico , Disfunção Ventricular Esquerda/fisiopatologia , Disfunção Ventricular Esquerda/terapia , Função Ventricular Esquerda , Adulto Jovem