Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Heart Rhythm O2 ; 5(1): 8-16, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38312208

RESUMO

Background: Conduction system pacing (CSP), either as His bundle pacing (HBP) or as left bundle branch area pacing (LBBAP), may be superior to right ventricular apical or septal pacing. Objective: The study sought to present acute results for a new guiding catheter (Biotronik Selectra 3D) designed for CSP implantations of a retractable screw-in lead (Biotronik Solia S). Methods: The primary endpoint of the prospective, international nonrandomized BIO|MASTER.Selectra 3D study was freedom from catheter-related serious adverse device effects (SADEs) within 1 week of lead implantation. Results: Of 157 enrolled patients, CSP was achieved in 147 (93.6%) patients. No SADEs occurred within 7 days. LBBAP was achieved in 82 patients (45 as crossover from an HBP attempt) and HBP in 65 (44.2%) patients. In centers considering both HBP and LBBAP, the CSP implantation success approached 99%. Successful CSP implantations lasted on average ∼50 minutes (fluoroscopy ∼6 minutes). Most procedures (87.9%) needed only 1 catheter, even after switch from HBP to LBBAP. The catheter's handling was rated largely positive. In patients without bundle branch block, mean QRS duration increased from 106 ms (intrinsic) to 122 ms (CSP) (P = .001). In patients with bundle branch block, mean QRS duration decreased from 151 ms (intrinsic) to 137 ms (CSP) (P = .004). Conclusion: The Selectra 3D catheter is a valuable tool for HBP and LBBAP implantations of the stylet-supported pacemaker leads. When implanters considered both HBP and LBBAP, the success rate was ∼99%. Flexibility to change between different approaches may be advisable in heterogeneous and challenging areas, such as CSP implantations.

2.
Oxf Med Case Reports ; 2017(9): omx051, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28928978

RESUMO

A 71-year-old female patient has a history of complete heart block and recurrent pacemaker site infection requiring multiple pacemaker explanations. A leadless pacemaker using passive fixation was inserted into the right ventricular apex via transvenous approach without complications. This case illustrates the feasibility of implanting a leadless pacemaker system in a small-sized adult with a low body mass index of 16 (weight: 33.7 kg, height: 145 cm) which may have potential application in elderly Asian subjects.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...