1.
J Clin Microbiol ; 59(3)2021 02 18.
Artigo em Inglês | MEDLINE | ID: mdl-33361338

RESUMO

Remote areas of many low and middle income (LMI) countries have poor access to HIV viral load (HIV VL) testing. The SAMBA II (simple amplification-based assay) Semi-Q whole-blood test (Diagnostics for the Real World [DRW], Cambridge, UK) is a point-of-care assay, which uses leucodepletion technology to allow whole-blood testing in remote settings. A total of 1,540 consecutive HIV-positive clinic patients in Cameroon (250), United Kingdom (633), Ukraine (412), and Zimbabwe (245) donated venous blood (all countries) and finger prick blood (all except UK) for testing on SAMBA II. SAMBA II results were compared with simultaneous plasma results on the Abbott RealTime HIV-1 (Abbott Molecular, Des Plaines, IL) viral load assay and interpreted as either <1,000 RNA copies/ml or ≥1,000 RNA copies/ml. For 1,528 venous whole-blood samples tested on SAMBA II, overall percent agreement with the reference test at a cutoff HIV VL of ≥1,000 copies/ml was 96.9% (1,480/1,528; 95% confidence interval [CI], 95.9% to 97.7%), negative percent agreement was 97.7% (1,259/1,289; 95% CI, 96.7% to 98.4%), and positive percent agreement was 92.5% (221/239; 95% CI, 88.4% to 95.5%). For 854 finger prick samples, there was 95.0% (811/854; 95% CI, 93.3% to 96.3%) overall percent agreement, 98.0% (625/638; 95% CI, 96.5% to 98.9%) negative percent agreement, and 86.1% (186/216; 95% CI, 80.8% to 90.4%) positive percent agreement. These rose to 93.5% (82.1% to 98.6%), 97.6% (95.6% to 98.8%), and 95.6% (93.3% to 97.3%) after exclusion of aberrant results from the Ukraine center. These results show a high level of agreement between SAMBA-II and a laboratory-based assay. SAMBA-II has a performance that is suitable to use as a VL point-of-care assay in remote settings.


Assuntos
Infecções por HIV , HIV-1 , Camarões , Infecções por HIV/diagnóstico , HIV-1/genética , Humanos , Sistemas Automatizados de Assistência Junto ao Leito , RNA Viral , Sensibilidade e Especificidade , Ucrânia , Reino Unido , Carga Viral
2.
PLoS One ; 14(11): e0223597, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31747448

RESUMO

BACKGROUND: In Zimbabwe, viral load (VL) testing for people living with HIV on antiretroviral therapy is performed at the National Microbiology Reference Laboratory using a NucliSens machine. Anecdotal evidence has shown that invalid graphs for "Target Not Detectable (TND)" will upon repeat VL testing produce a valid result for virus not detected, therefore removing the need to repeat the test. This needs formal assessment. OBJECTIVES: To determine i) intra- and inter-rater agreement of the visual interpretation of NucliSens graphs (Target Detectable [TD], TND and No Line [NL]) between two laboratory scientists and ii) sensitivity, specificity and predictive values of the NucliSens graphs compared with repeat VL results. METHOD: Cross sectional study using secondary data. Two laboratory scientists independently rated graphs one week apart for intra-rater agreement and compared final ratings with each other for inter-rater agreement. Consensus interpretations of graphs were compared with repeat VL results. Kappa coefficients were used to obtain measures of agreement. RESULTS: There were 562 patients with NucliSens graphs and repeat VL. Kappa scores were: 0.98 (Scientist A); 0.99 (Scientist B); 0.96 (Scientist A versus Scientist B); and 0.65 (NucliSens graphs versus VL). Sensitivity, specificity, positive predictive value and negative predictive value for graphs compared with VL were 71%, 92%, 79% and 89% respectively. CONCLUSION: Intra-and inter-rater agreements were almost perfect. The negative predictive value translates to a false negative rate of 11%. If repeat VL testing is not done, the clinical consequences need to be balanced against cost savings and the risks outweigh the benefits.


Assuntos
Gráficos por Computador , Interpretação Estatística de Dados , Infecções por HIV/virologia , Carga Viral , Virologia/instrumentação , Adulto , Artefatos , Estudos Transversais , Feminino , Humanos , Masculino , Variações Dependentes do Observador
3.
Diagnostics (Basel) ; 9(3)2019 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-31366024

RESUMO

While reporting human immunodeficiency virus (HIV) viral load (VL) using dried blood spot (DBS) in the BioMerieux NucliSENS platform, application of the hematocrit correction factor has been suggested. In this cross-sectional study from the National Microbiology Reference Laboratory of Zimbabwe, we assessed whether hematocrit correction (individual and/or mean) in DBS results improved the correlation with plasma VL and prediction of VL non-suppression (≥1000 copies per ml in plasma). Of 517 specimens during August-December 2018, 65(12.6%) had non-suppressed plasma VL results. The hematocrit correction factor ranged from 1.3 to 2.0 with a mean of 1.6, standard deviation (SD: 1.5, 1.7). The intraclass correlation (ICC) for mean (0.859, 95% CI: 0.834, 0.880) and individual (0.809, 95% CI: 0.777, 0.837) hematocrit corrected DBS results were not significantly different. The uncorrected DBS results had a significantly lower ICC (0.640, 95% CI: 0.586, 0.688) when compared to corrected DBS results. There were no significant differences in validity, predictive values, and areas under the receiver operating characteristics curves for all three DBS results when predicting VL non-suppression. To conclude, hematocrit correction of DBS VL results improved agreement with the plasma results but did not improve prediction of VL non-suppression. The results were not significantly different for individual and mean corrected results.