Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Appl Radiat Isot ; 153: 108826, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31525708

RESUMO

Holmium-166 is a high-energy ß--emitter radionuclide (~ 1.8 MeV) with a short half-life (~26.8h) that offers great potential as an alternative to 90Y for the treatment of liver cancer based on radioembolization. The possibility of quantitative Single Photon Emission Computed Tomography (SPECT) imaging of the main γ-ray emission at 80.6 keV, in addition to strong paramagnetic properties suitable for Magnetic Resonance Imaging (MRI), complement this therapeutic potential. The present paper describes the measurements carried out in three European radionuclide metrology laboratories for primary standardization of 166Ho and new determinations of X- and γ-ray photon-emission intensities in the framework of the European EMPIR project MRTDosimetry. New half-life measurements were also performed.


Assuntos
Hólmio/análise , Doses de Radiação , Radioisótopos/análise , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/radioterapia , Tomografia Computadorizada de Emissão de Fóton Único
2.
Phys Lett B ; 761: 281-286, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-28057978

RESUMO

The hypothesis that proximity to the Sun causes variation of decay constants at permille level has been tested and disproved. Repeated activity measurements of mono-radionuclide sources were performed over periods from 200 days up to four decades at 14 laboratories across the globe. Residuals from the exponential nuclear decay curves were inspected for annual oscillations. Systematic deviations from a purely exponential decay curve differ from one data set to another and are attributable to instabilities in the instrumentation and measurement conditions. The most stable activity measurements of alpha, beta-minus, electron capture, and beta-plus decaying sources set an upper limit of 0.0006% to 0.008% to the amplitude of annual oscillations in the decay rate. Oscillations in phase with Earth's orbital distance to the Sun could not be observed within a 10-6 to 10-5 range of precision. There are also no apparent modulations over periods of weeks or months. Consequently, there is no indication of a natural impediment against sub-permille accuracy in half-life determinations, renormalisation of activity to a distant reference date, application of nuclear dating for archaeology, geo- and cosmochronology, nor in establishing the SI unit becquerel and seeking international equivalence of activity standards.

3.
Appl Radiat Isot ; 109: 231-235, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26651176

RESUMO

The present paper addresses the calibration of well-type ionization chambers (ICs) used at LNE-LNHB as standard transfer instruments to calibrate hospitals in the case of SIR-Spheres(®)(90)Y resin microspheres (Sirtex, Australia). Developed for interventional oncology, this radiopharmaceutical is directly injected in the liver for cancer treatment via a selective internal radiation therapy. The present work was carried out in the framework of the European project "Metrology for molecular radiotherapy" (MetroMRT). As commonly performed in radionuclide metrology for radiopharmaceuticals, the objective is to ensure the metrological traceability of SIR-Spheres(®) to hospitals. Preceding studies were focused on primary measurements of SIR-Spheres(®) based on the TDCR (Triple to Double Coincidence Ratio) method, applied after the dissolution of the (90)Y-labeled resin microspheres. As (90)Y is a high-energy ß(-)-emitter, the IC response strongly depends on the transport of electrons in the radioactive solution and surroundings (vial, chamber liners and materials). The variability of the IC-response due to the geometry dependence is investigated by means of measurements and Monte Carlo simulations in the case of a Vinten IC. The aim of the present study was also to propose a reliable uncertainty for ICs calibrations for the standard transfer of SIR-Spheres(®) to hospitals.

4.
Appl Radiat Isot ; 97: 170-176, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25579458

RESUMO

The project "Metrology for molecular radiotherapy" is a collaborative European project initiated to bring together expertize in ionizing radiation metrology and nuclear medicine research. This project deals with the development of personalized dosimetry to individual patients who are undergoing molecular radiotherapy (also known as targeted radionuclide therapy). The general aim is to provide a metrological traceability to primary standards for individual dosimetry in the case of molecular radiotherapy. In particular, one objective is the standardization of (90)Y-labeled resin microspheres SIR-Spheres (Sirtex, Sydney, Australia) used for the treatment of liver cancer by radioembolization. The present paper describes the primary measurements carried out using the Triple to Double Coincidence Ratio (TDCR) method applied after the complete dissolution of the SIR-Spheres in the Sirtex vial. A method for the dissolution was developed to optimize the homogeneity of the solution to enable the primary measurements based on Cherenkov and liquid scintillation counting. A comprehensive description of the protocol implemented for the microsphere dissolution is reported. First calibration factors obtained with the reference ionization chambers at LNE-LNHB are also given.

5.
Appl Radiat Isot ; 70(9): 2232-6, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22429557

RESUMO

The response of a Vacutec 70129 ionization chamber was calculated using the PENELOPE-2008 Monte Carlo code and compared to experimental data. The filling gas mixture composition and its pressure have been determined using IC simulated response adjustment to experimental results. The Monte Carlo simulation revealed a physical effect in the detector response to photons due to the presence of xenon in the chamber. A very good agreement is found between calculated and experimental calibration coefficients for 17 radionuclides.


Assuntos
Modelos Estatísticos , Radiometria/instrumentação , Radiometria/normas , Calibragem , Simulação por Computador , Análise de Falha de Equipamento , Internacionalidade , Doses de Radiação , Padrões de Referência , Valores de Referência
6.
Phys Rev C Nucl Phys ; 54(2): 784-790, 1996 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-9971402
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...