Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 296
Filtrar
2.
Eur Phys J C Part Fields ; 84(1): 18, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38205101

RESUMO

High-precision searches for an electric dipole moment of the neutron (nEDM) require stable and uniform magnetic field environments. We present the recent achievements of degaussing and equilibrating the magnetically shielded room (MSR) for the n2EDM experiment at the Paul Scherrer Institute. We present the final degaussing configuration that will be used for n2EDM after numerous studies. The optimized procedure results in a residual magnetic field that has been reduced by a factor of two. The ultra-low field is achieved with the full magnetic-field-coil system, and a large vacuum vessel installed, both in the MSR. In the inner volume of ∼1.4m3, the field is now more uniform and below 300 pT. In addition, the procedure is faster and dissipates less heat into the magnetic environment, which in turn, reduces its thermal relaxation time from 12h down to 1.5h.

3.
Eur Phys J C Part Fields ; 83(11): 1061, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38021215

RESUMO

We present a novel Active Magnetic Shield (AMS), designed and implemented for the n2EDM experiment at the Paul Scherrer Institute. The experiment will perform a high-sensitivity search for the electric dipole moment of the neutron. Magnetic-field stability and control is of key importance for n2EDM. A large, cubic, 5 m side length, magnetically shielded room (MSR) provides a passive, quasi-static shielding-factor of about 105 for its inner sensitive volume. The AMS consists of a system of eight complex, feedback-controlled compensation coils constructed on an irregular grid spanned on a volume of less than 1000 m3 around the MSR. The AMS is designed to provide a stable and uniform magnetic-field environment around the MSR, while being reasonably compact. The system can compensate static and variable magnetic fields up to ±50µT (homogeneous components) and ±5µT/m (first-order gradients), suppressing them to a few µT in the sub-Hertz frequency range. The presented design concept and implementation of the AMS fulfills the requirements of the n2EDM experiment and can be useful for other applications, where magnetically silent environments are important and spatial constraints inhibit simpler geometrical solutions.

4.
Phys Rev Lett ; 131(19): 191801, 2023 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-38000426

RESUMO

Models that postulate the existence of hidden sectors address contemporary questions, such as the source of baryogenesis and the nature of dark matter. Neutron-to-hidden-neutron oscillations are among the possible mixing processes and have been tested with ultracold neutron storage and passing-through-wall experiments to set constraints on the oscillation period τ_{nn^{'}}. These searches probe the oscillations as a function of the mass splitting due to the neutron-hidden-neutron energy degeneracy. In this work, we present a new limit derived from neutron disappearance in ultracold neutron beam experiments. The overall limit, given by τ_{nn^{'}}>1 s for |δm|∈[2,69] peV(95.45% C.L.), covers the yet unexplored intermediate mass-splitting range and contributes to the ongoing research on hidden sectors.

5.
Phys Rev Lett ; 131(14): 142501, 2023 Oct 06.
Artigo em Inglês | MEDLINE | ID: mdl-37862664

RESUMO

We present the measurement of the two-neutrino double-ß decay rate of ^{76}Ge performed with the GERDA Phase II experiment. With a subset of the entire GERDA exposure, 11.8 kg yr, the half-life of the process has been determined: T_{1/2}^{2ν}=(2.022±0.018_{stat}±0.038_{syst})×10^{21} yr. This is the most precise determination of the ^{76}Ge two-neutrino double-ß decay half-life and one of the most precise measurements of a double-ß decay process. The relevant nuclear matrix element can be extracted: M_{eff}^{2ν}=(0.101±0.001).

6.
Eur Phys J C Part Fields ; 83(9): 778, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37674593

RESUMO

We search for tri-nucleon decays of 76Ge in the dataset from the GERmanium Detector Array (GERDA) experiment. Decays that populate excited levels of the daughter nucleus above the threshold for particle emission lead to disintegration and are not considered. The ppp-, ppn-, and pnn-decays lead to 73Cu, 73Zn, and 73Ga nuclei, respectively. These nuclei are unstable and eventually proceed by the beta decay of 73Ga to 73Ge (stable). We search for the 73Ga decay exploiting the fact that it dominantly populates the 66.7 keV 73mGa state with half-life of 0.5 s. The nnn-decays of 76Ge that proceed via 73mGe are also included in our analysis. We find no signal candidate and place a limit on the sum of the decay widths of the inclusive tri-nucleon decays that corresponds to a lower lifetime limit of 1.2×1026 yr  (90% credible interval). This result improves previous limits for tri-nucleon decays by one to three orders of magnitude.

7.
Hong Kong Med J ; 29(4): 311-321, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37532669

RESUMO

INTRODUCTION: We conducted translation and psychometric validation of a self-administered, 22-item dichotomous response-based questionnaire to identify nocturia aetiologies and co-morbidities in adult patients. METHODS: The Targeting the individual's Aetiology of Nocturia to Guide Outcomes (TANGO) questionnaire was forward- and backward-translated, then finalised using a standardised methodology. The resulting version, a Chinese version of the TANGO [TANGO (CV)], was evaluated for internal consistency, test-retest reliability, content validity, convergent validity, criterion validity, and discriminant validity via responses from 65 participants (46 men and 19 women; mean age, 67 years, range, 50-88), in comparison with other validated questionnaires and a 4-day bladder/sleep diary. RESULTS: Only 0.4% of responses were missing; 3% of participants required assistance with comprehension. The Kuder-Richardson Formula 20 (KR-20) coefficient for the whole tool was 0.711. Kappa values for individual domains and the whole tool varied from 0.871 to 0.866, indicating satisfactory test-retest reliability. There was strong agreement between the sum of positive responses to each domain and the whole tool (intra-class correlation coefficient=0.878-1.000). Modest correlations (ρ=0.4-0.6) were detected between the tool and bladder/sleep diary-based parameters for convergent validity. Criterion validity was confirmed for each domain and the whole tool [ρ=0.287-0.687]. In receiver operating characteristic analysis, the tool could distinguish patients (≥2 nocturia episodes/night) from controls (≤1 nocturia episode/night) [Youden's J statistic=0.453, area under the curve=0.818, 95% confidence interval (CI)=0.683-0.953] and patients with significant nocturia distress from patients with mild nocturia distress (Youden's J statistic=0.398, area under the curve=0.729, 95% CI=0.581-0.878). CONCLUSION: The TANGO (CV) was formally crossculturally adapted and translated. Its psychometric properties (except sensitivity to change) were validated.


Assuntos
Noctúria , Adulto , Masculino , Humanos , Feminino , Idoso , Noctúria/diagnóstico , Noctúria/etiologia , Comparação Transcultural , Psicometria , Reprodutibilidade dos Testes , Inquéritos e Questionários
8.
Hong Kong Med J ; 29(4): 324-329, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37424071

RESUMO

INTRODUCTION: Prostate-specific antigen-based screening for prostate cancer reportedly does not improve cancer-specific survival. However, there remain concerns about the increasing incidence of advanced disease at initial presentation. Here, we investigated the incidences and types of complications that occur during the course of disease in patients with metastatic hormone-sensitive prostate cancer (mHSPC). METHODS: This study included 100 consecutive patients who were diagnosed with mHSPC at five hospitals from January 2016 to August 2017. Analyses were conducted using patient data extracted from a prospectively collected database, along with information about complications and readmission obtained from electronic medical records. RESULTS: The median patient age was 74 years and the median serum prostate-specific antigen level at diagnosis was 202.5 ng/mL. Ninety-nine patients received androgen deprivation therapy; 17 of these patients also received chemotherapy. During a mean follow-up period of 32.9 months, 41 patients reported bone pain; of these patients, 21 developed pathologic fractures and eight had cord compression. Twenty-eight patients developed retention of urine; of these patients, 10 (36%) required surgery and 11 (39%) required long-term urethral catheter use. Among 15 patients who developed ureteral obstruction, four (27%) required ureteral stenting and four (27%) required long-term nephrostomy drainage. Other complications included anaemia (41%) and deep vein thrombosis (4%). Fifty-nine (59%) patients had ≥1 unplanned hospital admission during the course of disease; 16% of such patients had >5 episodes of readmission. CONCLUSION: Among patients with mHSPC, 70% experienced disease-related complications and unplanned hospital admissions, which substantially burdened both patients and the healthcare system.


Assuntos
Neoplasias da Próstata , Masculino , Humanos , Idoso , Neoplasias da Próstata/complicações , Neoplasias da Próstata/tratamento farmacológico , Antígeno Prostático Específico , Antagonistas de Androgênios/efeitos adversos , Hormônios/uso terapêutico
9.
Hong Kong Med J ; 29(4): 359.e1-359.e3, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37316159
10.
Hong Kong Med J ; 29(3): 208-213, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37349137

RESUMO

INTRODUCTION: Didactic lectures have been the foundation of learning for many medical students. However, in recent years, the flipped classroom model has become increasingly popular in medical education. This approach enhances pre-class learning, allowing the limited contact time between clinicians and medical students to be focused on practical issues. This study evaluated the effectiveness and non-inferiority of online micromodule teaching in terms of knowledge transfer concerning specific urology topics. METHODS: Medical students without prior exposure to the urology subspecialty were enrolled in the study, then randomised to a traditional didactic lecture group or an online micromodule group. Knowledge transfer was assessed by pre-intervention and post-intervention multiple-choice questions and objective structured clinical examinations that involved the acquisition of medical histories from real patients. RESULTS: In total, 45 medical students were enrolled (22 in the traditional didactic group and 23 in the online micromodule group). In terms of knowledge transfer (assessed by objective structured clinical examinations), the efficacy of online micromodules was comparable to traditional didactic lectures, although the difference was not statistically significant (P=0.823). There were no significant differences in terms of knowledge acquisition, retention, or clinical application between the two groups. CONCLUSION: In terms of acquiring, retaining, and applying foundational urological knowledge, online micromodules can help medical students to achieve outcomes comparable with the outcomes of didactic lectures. Online micromodules may be a viable alternative to traditional didactic lectures in urology education.


Assuntos
Educação Médica , Estudantes de Medicina , Humanos , Estudos de Viabilidade , Aprendizagem , Escolaridade , Currículo
11.
Eur Phys J C Part Fields ; 83(4): 319, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37122826

RESUMO

The ability to detect liquid argon scintillation light from within a densely packed high-purity germanium detector array allowed the Gerda experiment to reach an exceptionally low background rate in the search for neutrinoless double beta decay of 76 Ge. Proper modeling of the light propagation throughout the experimental setup, from any origin in the liquid argon volume to its eventual detection by the novel light read-out system, provides insight into the rejection capability and is a necessary ingredient to obtain robust background predictions. In this paper, we present a model of the Gerda liquid argon veto, as obtained by Monte Carlo simulations and constrained by calibration data, and highlight its application for background decomposition.

12.
Hong Kong Med J ; 29(2): 174.e1-174.e3, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-37088704
14.
Rev Sci Instrum ; 93(9): 095105, 2022 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-36182526

RESUMO

We present the magnetically shielded room (MSR) for the n2EDM experiment at the Paul Scherrer Institute, which features an interior cubic volume with each side of length 2.92 m, thus providing an accessible space of 25 m3. The MSR has 87 openings of diameter up to 220 mm for operating the experimental apparatus inside and an intermediate space between the layers for housing sensitive signal processing electronics. The characterization measurements show a remanent magnetic field in the central 1 m3 below 100 pT and a field below 600 pT in the entire inner volume, up to 4 cm to the walls. The quasi-static shielding factor at 0.01 Hz measured with a sinusoidal 2 µT peak-to-peak signal is about 100 000 in all three spatial directions and increases rapidly with frequency to reach 108 above 1 Hz.

15.
Eur Phys J C Part Fields ; 81(6): 512, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34720721

RESUMO

We present the design of a next-generation experiment, n2EDM, currently under construction at the ultracold neutron source at the Paul Scherrer Institute (PSI) with the aim of carrying out a high-precision search for an electric dipole moment of the neutron. The project builds on experience gained with the previous apparatus operated at PSI until 2017, and is expected to deliver an order of magnitude better sensitivity with provision for further substantial improvements. An overview is of the experimental method and setup is given, the sensitivity requirements for the apparatus are derived, and its technical design is described.

16.
Eur Phys J A Hadron Nucl ; 57(4): 152, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34776778

RESUMO

Psychological bias towards, or away from, prior measurements or theory predictions is an intrinsic threat to any data analysis. While various methods can be used to try to avoid such a bias, e.g. actively avoiding looking at the result, only data blinding is a traceable and trustworthy method that can circumvent the bias and convince a public audience that there is not even an accidental psychological bias. Data blinding is nowadays a standard practice in particle physics, but it is particularly difficult for experiments searching for the neutron electric dipole moment (nEDM), as several cross measurements, in particular of the magnetic field, create a self-consistent network into which it is hard to inject a false signal. We present an algorithm that modifies the data without influencing the experiment. Results of an automated analysis of the data are used to change the recorded spin state of a few neutrons within each measurement cycle. The flexible algorithm may be applied twice (or more) to the data, thus providing the option of sequentially applying various blinding offsets for separate analysis steps with independent teams. The subtle manner in which the data are modified allows one subsequently to adjust the algorithm and to produce a re-blinded data set without revealing the initial blinding offset. The method was designed for the 2015/2016 measurement campaign of the nEDM experiment at the Paul Scherrer Institute. However, it can be re-used with minor modification for the follow-up experiment n2EDM, and may be suitable for comparable projects elsewhere.

18.
Hong Kong Med J ; 27(4): 258-265, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33632937

RESUMO

INTRODUCTION: The objective was to investigate the changes in urology practice during coronavirus disease 2019 (COVID-19) pandemic with a perspective from our experience with severe acute respiratory syndrome (SARS) in 2003. METHODS: Institutional data from all urology centres in the Hong Kong public sector during the COVID-19 pandemic (1 Feb 2020-31 Mar 2020) and a non-COVID-19 control period (1 Feb 2019-31 Mar 2019) were acquired. An online anonymous questionnaire was used to gauge the impact of COVID-19 on resident training. The clinical output of tertiary centres was compared with data from the SARS period. RESULTS: The numbers of operating sessions, clinic attendance, cystoscopy sessions, prostate biopsy, and shockwave lithotripsy sessions were reduced by 40.5%, 28.5%, 49.6%, 44.8%, and 38.5%, respectively, across all the centres reviewed. The mean numbers of operating sessions before and during the COVID-19 pandemic were 85.1±30.3 and 50.6±25.7, respectively (P=0.005). All centres gave priority to cancer-related surgeries. Benign prostatic hyperplasia-related surgery (39.1%) and ureteric stone surgery (25.5%) were the most commonly delayed surgeries. The degree of reduction in urology services was less than that during SARS (47.2%, 55.3%, and 70.5% for operating sessions, cystoscopy, and biopsy, respectively). The mean numbers of operations performed by residents before and during the COVID-19 pandemic were 75.4±48.0 and 34.9±17.2, respectively (P=0.002). CONCLUSION: A comprehensive review of urology practice during the COVID-19 pandemic revealed changes in every aspect of practice.


Assuntos
COVID-19/epidemiologia , Controle de Doenças Transmissíveis/métodos , Internato e Residência , Padrões de Prática Médica , Síndrome Respiratória Aguda Grave/epidemiologia , Procedimentos Cirúrgicos Urológicos , Urologia , Atenção à Saúde/organização & administração , Atenção à Saúde/tendências , Surtos de Doenças/estatística & dados numéricos , Hong Kong/epidemiologia , Humanos , Internato e Residência/métodos , Internato e Residência/organização & administração , Inovação Organizacional , Padrões de Prática Médica/organização & administração , Padrões de Prática Médica/tendências , SARS-CoV-2 , Procedimentos Cirúrgicos Urológicos/métodos , Procedimentos Cirúrgicos Urológicos/estatística & dados numéricos , Urologia/educação , Urologia/estatística & dados numéricos
19.
Sci Adv ; 6(37)2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32917695

RESUMO

Embryonic diapause is a maternally controlled phenomenon. The molecule controlling the onset of the phenomenon is unknown. We demonstrated that overexpression of microRNA let-7a or incubation with let-7g-enriched extracellular vesicles from endometrial epithelial cells prolonged the in vitro survival of mouse blastocysts, which developed into live pups after having been transferred to foster mothers. Similar to in vivo dormant blastocysts, let-7-induced dormant blastocysts exhibited low level of proliferation, apoptosis, and nutrient metabolism. Let-7 suppressed c-myc/mTORC1 and mTORC2 signaling to induce embryonic diapause. It also inhibited ODC1 expression reducing biosynthesis of polyamines, which are known to reactivate dormant embryos. Furthermore, the overexpression of let-7 blocked trophoblast differentiation and implantation potential of human embryo surrogates, and prolonged survival of human blastocysts in vitro, supporting the idea that embryonic diapause was an evolutionary conserved phenomenon. In conclusion, let-7 is the main factor inducing embryonic diapause.


Assuntos
Diapausa , Vesículas Extracelulares , MicroRNAs , Animais , Blastocisto/fisiologia , Implantação do Embrião/genética , Desenvolvimento Embrionário/genética , Endométrio/metabolismo , Vesículas Extracelulares/metabolismo , Feminino , Camundongos , MicroRNAs/genética , MicroRNAs/metabolismo
20.
Phys Rev Lett ; 124(8): 081803, 2020 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-32167372

RESUMO

We present the result of an experiment to measure the electric dipole moment (EDM) of the neutron at the Paul Scherrer Institute using Ramsey's method of separated oscillating magnetic fields with ultracold neutrons. Our measurement stands in the long history of EDM experiments probing physics violating time-reversal invariance. The salient features of this experiment were the use of a ^{199}Hg comagnetometer and an array of optically pumped cesium vapor magnetometers to cancel and correct for magnetic-field changes. The statistical analysis was performed on blinded datasets by two separate groups, while the estimation of systematic effects profited from an unprecedented knowledge of the magnetic field. The measured value of the neutron EDM is d_{n}=(0.0±1.1_{stat}±0.2_{sys})×10^{-26} e.cm.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...