1.
J Instrum ; 9: C07004, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25018777

RESUMO

A novel positron emission tomography (PET) scanner design based on a room-temperature pixelated CdTe solid-state detector is being developed within the framework of the Voxel Imaging PET (VIP) Pathfinder project [1]. The simulation results show a great potential of the VIP to produce high-resolution images even in extremely challenging conditions such as the screening of a human head [2]. With unprecedented high channel density (450 channels/cm3) image reconstruction is a challenge. Therefore optimization is needed to find the best algorithm in order to exploit correctly the promising detector potential. The following reconstruction algorithms are evaluated: 2-D Filtered Backprojection (FBP), Ordered Subset Expectation Maximization (OSEM), List-Mode OSEM (LM-OSEM), and the Origin Ensemble (OE) algorithm. The evaluation is based on the comparison of a true image phantom with a set of reconstructed images obtained by each algorithm. This is achieved by calculation of image quality merit parameters such as the bias, the variance and the mean square error (MSE). A systematic optimization of each algorithm is performed by varying the reconstruction parameters, such as the cutoff frequency of the noise filters and the number of iterations. The region of interest (ROI) analysis of the reconstructed phantom is also performed for each algorithm and the results are compared. Additionally, the performance of the image reconstruction methods is compared by calculating the modulation transfer function (MTF). The reconstruction time is also taken into account to choose the optimal algorithm. The analysis is based on GAMOS [3] simulation including the expected CdTe and electronic specifics.

2.
J Instrum ; 9(5)2014 May 12.
Artigo em Inglês | MEDLINE | ID: mdl-24883078

RESUMO

Over the last two decades there have been a growing number of designs for positron emission tomography (PET) cameras optimized to image the breast. These devices, commonly known as positron emission mammography (PEM) cameras allow much more spatial resolution by putting the photon detectors directly on the breast. PEM cameras have a compact geometry with a restricted field of view (FOV) thus exhibiting higher performance and lower cost than large whole body PET scanners. Typical PEM designs are based on scintillators such as bismuth germanate (BGO), lutetium oxorthosilicate (LSO) or lutetium yttrium orthosicilate (LYSO), and characterized by large parallax error due to deficiency of the depth of interaction (DOI) information from crystals. In the case of parallel geometry PEM, large parallax error results in poor image resolution along the vertical axis. In the framework of the Voxel Imaging PET (VIP) pathfinder project, we propose a high resolution PEM scanner based on pixelated solid-state CdTe detectors. The pixel PEM device with a millimeter-size pixel pitch provides an excellent spatial resolution in all directions 8 times better than standard commercial devices with a point spread function (PSF) of 1 mm full width at half maximum (FWHM) and excellent energy resolution of down to 1.6% FWHM at 511 keV photons at room temperature. The system is capable to detect down to 1 mm diameter hot spheres in warm background.

3.
J Instrum ; 9(6)2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24932209

RESUMO

A proposed Compton camera prototype based on pixelated CdTe is simulated and evaluated in order to establish its feasibility and expected performance in real laboratory tests. The system is based on module units containing a 2×4 array of square CdTe detectors of 10×10 mm2 area and 2 mm thickness. The detectors are pixelated and stacked forming a 3D detector with voxel sizes of 2 × 1 × 2 mm3. The camera performance is simulated with Geant4-based Architecture for Medicine-Oriented Simulations(GAMOS) and the Origin Ensemble(OE) algorithm is used for the image reconstruction. The simulation shows that the camera can operate with up to 104 Bq source activities with equal efficiency and is completely saturated at 109 Bq. The efficiency of the system is evaluated using a simulated 18F point source phantom in the center of the Field-of-View (FOV) achieving an intrinsic efficiency of 0.4 counts per second per kilobecquerel. The spatial resolution measured from the point spread function (PSF) shows a FWHM of 1.5 mm along the direction perpendicular to the scatterer, making it possible to distinguish two points at 3 mm separation with a peak-to-valley ratio of 8.

4.
J Instrum ; 9: C12027, 2014 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-25729404

RESUMO

The Voxel Imaging PET (VIP) Pathfinder project intends to show the advantages of using pixelated semiconductor technology for nuclear medicine applications to achieve an improved image reconstruction without efficiency loss. It proposes designs for Positron Emission Tomography (PET), Positron Emission Mammography (PEM) and Compton gamma camera detectors with a large number of signal channels (of the order of 106). The design is based on the use of a pixelated CdTe Schottky detector to have optimal energy and spatial resolution. An individual read-out channel is dedicated for each detector voxel of size 1 × 1 × 2 mm3 using an application-specific integrated circuit (ASIC) which the VIP project has designed, developed and is currently evaluating experimentally. The behaviour of the signal charge carriers in CdTe should be well understood because it has an impact on the performance of the readout channels. For this purpose the Finite Element Method (FEM) Multiphysics COMSOL software package has been used to simulate the behaviour of signal charge carriers in CdTe and extract values for the expected charge sharing depending on the impact point and bias voltage. The results on charge sharing obtained with COMSOL are combined with GAMOS, a Geant based particle tracking Monte Carlo software package, to get a full evaluation of the amount of charge sharing in pixelated CdTe for different gamma impact points.

5.
J Instrum ; 9: C12032, 2014 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-25729405

RESUMO

We report on the measurement of drift properties of electrons and holes in a CdTe diode grown by the travelling heating method (THM). Mobility and lifetime of both charge carriers has been measured independently at room temperature and fixed bias voltage using charge integration readout electronics. Both electrode sides of the detector have been exposed to a 241Am source in order to obtain events with full contributions of either electrons or holes. The drift time has been measured to obtain the mobility for each charge carrier. The Hecht equation has been employed to evaluate the lifetime. The measured values for µτe/h (mobility-lifetime product) are in agreement with earlier published data.

6.
J Instrum ; 82013 Apr 29.
Artigo em Inglês | MEDLINE | ID: mdl-23814604

RESUMO

The Voxel Imaging PET (VIP) Pathfinder project intends to show the advantages of using pixelated solid-state technology for nuclear medicine applications. It proposes designs for Positron Emission Tomography (PET), Positron Emission Mammography (PEM) and Compton gamma camera detectors with a large number of signal channels (of the order of 106). For PET scanners, conventional algorithms like Filtered Back-Projection (FBP) and Ordered Subset Expectation Maximization (OSEM) are straightforward to use and give good results. However, FBP presents difficulties for detectors with limited angular coverage like PEM and Compton gamma cameras, whereas OSEM has an impractically large time and memory consumption for a Compton gamma camera with a large number of channels. In this article, the Origin Ensemble (OE) algorithm is evaluated as an alternative algorithm for image reconstruction. Monte Carlo simulations of the PET design are used to compare the performance of OE, FBP and OSEM in terms of the bias, variance and average mean squared error (MSE) image quality metrics. For the PEM and Compton camera designs, results obtained with OE are presented.

7.
J Instrum ; 82013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23750177

RESUMO

We report on the characterization of 2 mm thick CdTe diode detector with Schottky contacts to be employed in a novel conceptual design of PET scanner. Results at -8°C with an applied bias voltage of -1000 V/mm show a 1.2% FWHM energy resolution at 511 keV. Coincidence time resolution has been measured by triggering on the preamplifier output signal to improve the timing resolution of the detector. Results at the same bias and temperature conditions show a FWHM of 6 ns with a minimum acceptance energy of 500 keV. These results show that pixelated CdTe Schottky diode is an excellent candidate for the development of next generation nuclear medical imaging devices such as PET, Compton gamma cameras, and especially PET-MRI hybrid systems when used in a magnetic field immune configuration.

8.
J Instrum ; 82013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23750176

RESUMO

A positron emission mammograph (PEM) is an organ dedicated positron emission tomography (PET) scanner for breast cancer detection. State-of-the-art PEMs employing scintillating crystals as detection medium can provide metabolic images of the breast with significantly higher sensitivity and specificity with respect to standard whole body PET scanners. Over the past few years, crystal PEMs have dramatically increased their importance in the diagnosis and treatment of early stage breast cancer. Nevertheless, designs based on scintillators are characterized by an intrinsic deficiency of the depth of interaction (DOI) information from relatively thick crystals constraining the size of the smallest detectable tumor. This work shows how to overcome such intrinsic limitation by substituting scintillating crystals with pixelated CdTe detectors. The proposed novel design is developed within the Voxel Imaging PET (VIP) Pathfinder project and evaluated via Monte Carlo simulation. The volumetric spatial resolution of the VIP-PEM is expected to be up to 6 times better than standard commercial devices with a point spread function of 1 mm full width at half maximum (FWHM) in all directions. Pixelated CdTe detectors can also provide an energy resolution as low as 1.5% FWHM at 511 keV for a virtually pure signal with negligible contribution from scattered events.

9.
Eur Radiol ; 22(1): 205-10, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21874360

RESUMO

OBJECTIVE: To test a digital imaging X-ray device based on the direct capture of X-ray photons with pixel detectors, which are coupled with photon-counting readout electronics. METHODS: The chip consists of a matrix of 256 × 256 pixels with a pixel pitch of 55 µm. A monolithic image of 11.2 cm × 7 cm was obtained by the consecutive displacement approach. Images of embalmed anatomical specimens of eight human hands were obtained at four different dose levels (skin dose 2.4, 6, 12, 25 µGy) with the new detector, as well as with a flat-panel detector. RESULTS: The overall rating scores for the evaluated anatomical regions ranged from 5.23 at the lowest dose level, 6.32 at approximately 6 µGy, 6.70 at 12 µGy, to 6.99 at the highest dose level with the photon-counting system. The corresponding rating scores for the flat-panel detector were 3.84, 5.39, 6.64, and 7.34. When images obtained at the same dose were compared, the new system outperformed the conventional DR system at the two lowest dose levels. At the higher dose levels, there were no significant differences between the two systems. CONCLUSION: The photon-counting detector has great potential to obtain musculoskeletal images of excellent quality at very low dose levels.


Assuntos
Mãos/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/instrumentação , Doenças Musculoesqueléticas/diagnóstico por imagem , Fótons , Intensificação de Imagem Radiográfica/instrumentação , Cadáver , Desenho de Equipamento , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Doses de Radiação , Intensificação de Imagem Radiográfica/métodos