Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Rev Sci Instrum ; 91(11): 113306, 2020 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-33261443

RESUMO

Versatile high-power pulsed electron-beam accelerators that meet the requirements of pulsed high-power specifications are needed for appropriate applications in medical industry, defense, and other industries. The pulsed electron beam accelerator comprising a Marx generator and Blumlein pulse forming line (PFL) is designed to accelerate the electron beams at the level of 1 MeV when electrostatically discharging. The performance specifications of Marx generators consisting of a 100 kV DC power supply, R-L-C circuit, and high voltage switch are at a maximum 800 kV. At this time, by using the capacitance mismatching principle between the Marx generator and the Blumlein PFL under the law of preserving the amount of charge, it is possible to generate a high voltage in the form of a square pulse up to about 1.1 MV, as much as 1.37 times the charged voltage of the Marx generator. As a result, energy transmission from the Marx generator with a high efficiency of about 85% to the Blumlein PFL is possible. The aim of this study is that the pulsed high-power electron-beam accelerator can be used to change the diode impedance, and the energy of the accelerated electron beam reaches a level of 1 MeV with the square pulse width of about 100 ns at the flat-top in the range of relativistic electron beam generation. Performance tests were securely carried out by installing a dummy load based on CuSO4 solution varying the diode impedance to deter damage to the circuit by preventing reflected waves from being generated in the load.

2.
J Radiat Res ; 59(5): 588-592, 2018 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-29939311

RESUMO

The Korea Heavy Ion Medical Accelerator project focuses on the development of medical accelerator facilities for delivering carbon-ion beams to cancer patients. The purpose of the present study was to estimate the clinical need for carbon-ion therapy in Korea. Seven tumor sites, namely head and neck, liver, lung, colon and rectum, prostate, bone and soft tissue, and pancreas were selected as eligible sites for receiving carbon-ion radiotherapy (RT) by radiation oncologists of the Korea Institute of Radiological and Medical Sciences. Cancer incidence data for the selected tumor sites were obtained from the Korea National Cancer Incidence Database in order to estimate the potential medical need for carbon-ion RT. The carbon-ion RT adaption rate was assessed based on the clinical experience of other carbon-ion therapy facilities. An estimation model was constructed for estimating the medical need for carbon-ion RT, and from this, 25 606 patients were deemed to be potential candidates for carbon-ion RT. This estimated potential need corresponded to 10% of newly diagnosed cancer patients in Korea. The realistic estimation was calculated as ranging between 4000 and 6300 patients, depending on the carbon-ion RT adaptation rate. This estimated medical need corresponded to 2-3% of newly diagnosed cancer patients in Korea. Taken together, our findings suggest that there is a clear medical need for carbon-ion RT in Korea, with at least 4000 potential patients per year.


Assuntos
Radioterapia com Íons Pesados , Neoplasias/radioterapia , Radioterapia (Especialidade)/métodos , Radioterapia (Especialidade)/normas , Neoplasias Ósseas/radioterapia , Carbono , Neoplasias do Colo/radioterapia , Bases de Dados Factuais , Fracionamento da Dose de Radiação , Feminino , Neoplasias de Cabeça e Pescoço/radioterapia , Humanos , Incidência , Neoplasias Hepáticas/radioterapia , Neoplasias Pulmonares/radioterapia , Masculino , Neoplasias/epidemiologia , Neoplasias Pancreáticas/radioterapia , Neoplasias da Próstata/radioterapia , Neoplasias Retais/radioterapia , República da Coreia , Neoplasias de Tecidos Moles/radioterapia
3.
Int J Oncol ; 47(4): 1440-50, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26314590

RESUMO

Endothelial cells (ECs), that comprise the tumor vasculature, are critical targets for anticancer radiotherapy. The aim of this work was to study the mechanism by which SU5416, a known anti-angiogenesis inhibitor, modifies the radiation responses of human vascular ECs. Two human endothelial cell lines (HUVEC and 2H11) were treated with SU5416 alone, radiation alone, or a combination of both. In vitro tests were performed using colony forming assays, FACS analysis, western blotting, immunohistochemistry, migration assay, invasion assays and endothelial tube formation assays. The combination of radiation and SU5416 significantly inhibited cell survival, the repair of radiation-induced DNA damage, and induced apoptosis. It also caused cell cycle arrest, inhibited cell migration and invasion, and suppressed angiogenesis. In this study, our results first provide a scientific rationale to combine SU5416 with radiotherapy to target ECs and suggest its clinical application in combination cancer treatment with radiotherapy.


Assuntos
Inibidores da Angiogênese/farmacologia , Células Endoteliais/efeitos dos fármacos , Células Endoteliais/efeitos da radiação , Indóis/farmacologia , Pirróis/farmacologia , Radiossensibilizantes/farmacologia , Apoptose/efeitos dos fármacos , Apoptose/efeitos da radiação , Western Blotting , Linhagem Celular , Movimento Celular/efeitos dos fármacos , Movimento Celular/efeitos da radiação , Proliferação de Células/efeitos dos fármacos , Proliferação de Células/efeitos da radiação , Citometria de Fluxo , Humanos , Imuno-Histoquímica
4.
Radiat Oncol ; 9: 193, 2014 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-25175383

RESUMO

BACKGROUND: To compare dosimetric parameters of volumetric modulated arc therapy (VMAT) and non-coplanar intensity modulated radiotherapy (IMRT) for nasal cavity and paranasal sinus cancer with regard to the coverage of planning target volume (PTV) and the sparing of organs at risk (OAR). METHODS: Ten patients with nasal cavity or paranasal sinus cancer were re-planned by VMAT (two-arc) plan and non-coplanar IMRT (7-, 11-, and 15-beam) plans. Planning objectives were to deliver 60 Gy in 30 fractions to 95% of PTV, with maximum doses (D(max)) of <50 Gy to the optic nerves, optic chiasm, and brainstem, <40 Gy to the eyes and <10 Gy to the lenses. The target mean dose (D(mean)) to the parotid glands was <25 Gy, and no constraints were applied to the lacrimal glands. Planning was optimized to minimized doses to OAR without compromising coverage of the PTV. VMAT and three non-coplanar IMRT (7-, 11-, and 15-beam) plans were compared using the heterogeneity and conformity indices (HI and CI) of the PTV, D(max) and D(mean) of the OAR, treatment delivery time, and monitor units (MUs). RESULTS: The HI and CI of VMAT plan were superior to those of the 7-, 11-, and 15-beam non-coplanar IMRT. VMAT and non-coplanar IMRT (7-, 11-, and 15-beam) showed equivalent sparing effects for the optic nerves, optic chiasm, brainstem, and parotid glands. For the eyes and lenses, VMAT achieved equivalent or better sparing effects when compared with the non-coplanar IMRT plans. VMAT showed lower MUs and reduced treatment delivery time when compared with non-coplanar IMRT. CONCLUSIONS: In 10 patients with nasal cavity or paranasal sinus cancer, a VMAT plan provided better homogeneity and conformity for PTV than non-coplanar IMRT plans, with a shorter treatment delivery time, while achieving equal or better OAR-sparing effects and using fewer MUs.


Assuntos
Cavidade Nasal/efeitos da radiação , Neoplasias dos Seios Paranasais/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Olho/efeitos da radiação , Humanos , Aparelho Lacrimal/efeitos da radiação , Nervo Óptico/efeitos da radiação , Órgãos em Risco/efeitos da radiação , Neoplasias dos Seios Paranasais/patologia , Seios Paranasais/patologia , Seios Paranasais/efeitos da radiação , Glândula Parótida/efeitos da radiação , Radiometria , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/efeitos adversos , Carga Tumoral
5.
Australas Phys Eng Sci Med ; 37(4): 635-44, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25154880

RESUMO

Conventional laser accelerated proton beam has broad energy spectra. It is not suitable for clinical use directly, so it is necessary for employing energy selection system. However, in the conventional laser accelerated proton system, the intensity of the proton beams in the low energy regime is higher than that in the high energy regime. Thus, to generate spread-out-Bragg peak (SOBP), stronger weighting value to the higher energy proton beams is needed and weaker weighting value to the lower energy proton beams is needed, which results in the wide range of weighting values. The purpose of this research is to investigate a method for efficient generating of the SOBP with varying magnetic field in the energy selection system using a carbon-proton mixture target. Energy spectrum of the laser accelerated proton beams was acquired using Particle-In-Cell simulations. The Geant4 Monte Carlo simulation toolkit was implemented for energy selection, particle transportation, and dosimetric property measurement. The energy selection collimator hole size of the energy selection system was changed from 1 to 5 mm in order to investigate the effect of hole size on the dosimetric properties for Bragg peak and SOBP. To generate SOBP, magnetic field in the energy selection system was changed during beam irradiation with each beam weighting factor. In this study, our results suggest that carbon-proton mixture target based laser accelerated proton beams can generate quasi-monoenergetic energy distribution and result in the efficient generation of SOBP. A further research is needed to optimize SOBP according to each range and modulated width using an optimized weighting algorithm.


Assuntos
Carbono/efeitos da radiação , Lasers , Modelos Estatísticos , Radiometria/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Alta Energia/métodos , Algoritmos , Simulação por Computador , Humanos , Método de Monte Carlo , Terapia com Prótons , Dosagem Radioterapêutica
6.
J Nanosci Nanotechnol ; 11(1): 773-7, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21446543

RESUMO

The Achilles tendon consists mainly of type I collagen fibers that contain collagen fibrils. When the Achilles tendon is injured, it is inflamed. The collagenase-induced model has been widely used to study tendinitis. The major advantages of atomic force microscopy (AFM) over conventional optical and electron microscopy for bio-imaging include its non-requirement of a special coating and vacuum, and its capability to perform imaging in all environments. AFM force-distance measurements have become a fundamental tool in the fields of surface chemistry, biochemistry and materials science. Therefore, the changes in the ultrastructure and adhesion force of the collagen fibrils on the Achilles tendons of rats with Achilles tendinitis were observed using AFM. The changes in the structure of the Achilles tendons were evaluated based on the diameter and D-banding of the collagen fibrils. Collagenase-induced Achilles tendinitis was induced with the injection of 30 microl crude collagenase into 7-week-old male Sprague-Dawley rats. The animals were each sacrificed on the first, second, third, fifth and seventh day after the collagenase injection. The normal and injured Achilles tendons were fixed in 4% buffered formalin and dehydrated with increasing concentrations of ethanol. AFM was performed using the non-contact mode at the resolution of 512 x 512 pixels, with a scan speed of 0.8 line/sec. The adhesion force was measured via the force-distance curve that resulted from the interactions between the AFM tip and the collagen fibril sample using the contact mode. The diameter of the collagen fibrils in the Achilles tendons significantly decreased (p < 0.05) after the collagenase injection, and the pattern of the D-banding of the collagen fibrils was similar to that of the diameter changes. The adhesion force decreased until the fifth day after the collagenase injection, but increased on the seventh day after the collagenase injection (p < 0.0001).


Assuntos
Tendão do Calcâneo/lesões , Colágeno/metabolismo , Microscopia de Força Atômica , Tendinopatia/metabolismo , Tendinopatia/patologia , Adesividade/efeitos dos fármacos , Animais , Fenômenos Biomecânicos/efeitos dos fármacos , Colágeno/química , Colagenases , Modelos Animais de Doenças , Masculino , Ratos , Ratos Sprague-Dawley , Tendinopatia/induzido quimicamente
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA