Phys Med ; 31(5): 553-9, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26048682

RESUMO

PURPOSE: This paper describes the hardware and software characteristics of a 3D optical scanner (P3DS) developed in-house. The P3DS consists of an LED light source, diffuse screen, step motor, CCD camera, and scanner management software with 3D reconstructed software. MATERIALS AND METHOD: We performed optical simulation, 2D and 3D reconstruction image testing, and pre-clinical testing for the P3DS. We developed the optical scanner with three key characteristics in mind. First, we developed a continuous scanning method to expand possible clinical applications. Second, we manufactured a collimator to improve image quality by reducing scattering from the light source. Third, we developed an optical scanner with changeable camera positioning to enable acquisition of optimal images according to the size of the gel dosimeter. RESULTS: We confirmed ray-tracing in P3DS with optic simulation and found that 2D projection and 3D reconstructed images were qualitatively similar to the phantom images. For pre-clinical tests, the dose distribution and profile showed good agreement among RTP, optical CT, and external beam radiotherapy film data for the axial and coronal views. The P3DS has shown that it can scan and reconstruct for evaluation of the gel dosimeter within 1 min. We confirmed that the P3DS system is a useful tool for the measurement of 3D dose distributions for 3D radiation therapy QA. Further experiments are needed to investigate quantitative analysis for 3D dose distribution.


Assuntos
Imageamento Tridimensional/instrumentação , Imagem Óptica/instrumentação , Medicina de Precisão/instrumentação , Doses de Radiação , Radiometria/instrumentação , Desenho de Equipamento , Humanos , Neuroma Acústico/diagnóstico por imagem , Tomografia Computadorizada por Raios X
2.
J Appl Clin Med Phys ; 13(6): 3818, 2012 Nov 08.
Artigo em Inglês | MEDLINE | ID: mdl-23149775

RESUMO

This study evaluated the mechanical accuracy of an in-house-developed couch-based tracking system (CBTS) according to respiration data. The overall delay time of the CBTS was calculated, and the accuracy, reproducibility, and loading effect of the CBTS were evaluated according to the sinusoidal waveform and various respiratory motion data of real patients with and without a volunteer weighing 75kg. The root mean square (rms) error of the accuracy, the reproducibility, and the sagging measurements were calculated for the three axes (X, Y, and Z directions) of the CBTS. The overall delay time of the CBTS was 0.251 sec. The accuracy and reproducibility in the Z direction in real patient data were poor, as indicated by high rms errors. The results of the loading effect were within 1.0 mm in all directions. This novel CBTS has the potential for clinical application for tumor tracking in radiation therapy.


Assuntos
Movimento/fisiologia , Neoplasias/radioterapia , Aceleradores de Partículas/instrumentação , Respiração , Humanos , Neoplasias/diagnóstico por imagem , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X
3.
Med Dosim ; 37(3): 296-304, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22277157

RESUMO

In this study, a computer-based system for routine quality assurance (QA) of a linear accelerator (linac) was developed by using the dosimetric properties of an amorphous silicon electronic portal imaging device (EPID). An acrylic template phantom was designed such that it could be placed on the EPID and be aligned with the light field of the collimator. After irradiation, portal images obtained from the EPID were transferred in DICOM format to a computer and analyzed using a program we developed. The symmetry, flatness, field size, and congruence of the light and radiation fields of the photon beams from the linac were verified simultaneously. To validate the QA system, the ion chamber and film (X-Omat V2; Kodak, New York, NY) measurements were compared with the EPID measurements obtained in this study. The EPID measurements agreed with the film measurements. Parameters for beams with energies of 6 MV and 15 MV were obtained daily for 1 month using this system. It was found that our QA tool using EPID could substitute for the film test, which is a time-consuming method for routine QA assessment.


Assuntos
Garantia da Qualidade dos Cuidados de Saúde/normas , Radiometria/instrumentação , Radiometria/normas , Radioterapia Conformacional/instrumentação , Radioterapia Conformacional/normas , Ecrans Intensificadores para Raios X/normas , Desenho de Equipamento , Internacionalidade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade