Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Turk J Gastroenterol ; 34(9): 932-942, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37565797

RESUMO

BACKGROUND/AIMS: The number of endoscopic procedures and related adverse events is increasing. We investigated South Korean endoscopists' awareness and experience of endoscopic adverse events. MATERIALS AND METHODS: We used Google Forms to conduct an online questionnaire survey among South Korean endoscopists from December 11 to 29, 2020. The survey comprised 30 questions developed by members of the Quality Management Committee of the Korean Society of Gastrointestinal Endoscopy. RESULTS: In total, 475 endoscopists participated in the survey. Of these, 454 (95.6%) were board-certified gastroenterologists and 255 (53.7%) had >10 years of endoscopy experience. Most participants had experienced serious adverse events requiring hospitalization (80.4%, 382/475); however, only 100 (21.1%) were aware of programs for the prevention and management of adverse endoscopic events in their affiliated endoscopy centers. Most participants (98.5%, 468/475) agreed with the need for education on medical accidents for healthcare workers. Responses were inconsistent regarding the definition of adverse events formulated by the 2010 American Society for Gastrointestinal Endoscopy Workshop. Most participants were not aware of the minimal standard terminology (76.6%, 364/475) and had not used it when writing endoscopy reports (88.8%, 422/475). Responses were inconsistent regarding which events to record in endoscopy records. CONCLUSION: Further discussion on the nationwide adverse-event reporting system and education program for adverse events related to endoscopy is needed to ensure the safety of patients and endoscopists.


Assuntos
Endoscopia Gastrointestinal , Gastroenterologistas , Humanos , Estados Unidos , Endoscopia Gastrointestinal/métodos , Inquéritos e Questionários , República da Coreia
2.
J Acoust Soc Am ; 136(2): EL72-7, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25096149

RESUMO

For the analysis of non-stationary signals generated by a non-linear process like fault of an induction motor, empirical mode decomposition (EMD) is the best choice as it decomposes the signal into its natural oscillatory modes known as intrinsic mode functions (IMFs). However, some of these oscillatory modes obtained from a fault signal are not significant as they do not bear any fault signature and can cause misclassification of the fault instance. To solve this issue, a novel IMF selection algorithm is proposed in this work.

3.
J Acoust Soc Am ; 131(2): EL126-32, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22352611

RESUMO

A modified loop filter design method for plucked string instruments is introduced. Previous loop filter designs do not properly represent the frequency-dependent damping of a silk stringed instrument. To solve this problem, the modified method evaluates how many harmonics are required and which portion of the sound should be chosen to effectively replicate the instrument. Then, the most reasonable filter parameters are determined based on the frequency signal-to-noise ratio of the synthesized sound.

4.
Nanoscale Res Lett ; 7: 30, 2012 Jan 05.
Artigo em Inglês | MEDLINE | ID: mdl-22221314

RESUMO

We developed a method to use NH2-functionalized polymer films to align and immobilize DNA molecules on a Si substrate. The plasma-polymerized cyclohexane film was deposited on the Si substrate according to the radio frequency plasma-enhanced chemical vapor deposition method using a single molecular precursor, and it was then treated by the dielectric barrier discharge method in a nitrogen environment under atmospheric pressure. Changes in the chemistry of the surface functional groups were studied using X-ray photoelectron spectroscopy and Fourier transformed infrared spectroscopy. The wettability of the surfaces was examined using dynamic contact angle measurements, and the surface morphology was evaluated using atomic force microscopy.We utilized a tilting method to align λ-DNA molecules that were immobilized by the electrostatic interaction between the amine groups in NH2-functionalized polymer films and the phosphate groups in the DNA. The DNA was treated with positively charged gold nanoparticles to make a conductive nanowire that uses the DNA as a template. We observed that the NH2-functionalized polymer film was useful for aligning and immobilizing the DNA, and thus the DNA-templated nanowires.

5.
Nanoscale Res Lett ; 7: 25, 2012 Jan 05.
Artigo em Inglês | MEDLINE | ID: mdl-22221881

RESUMO

Metal-doped ZnO [MZO] thin films show changes of the following properties by a dopant. First, group III element (Al, In, Ga)-doped ZnO thin films have a high conductivity having an n-type semiconductor characteristic. Second, group I element (Li, Na, K)-doped ZnO thin films have high resistivity due to a dopant that accepts a carrier. The metal-doped ZnO (M = Li, Ag) films were prepared by radio frequency magnetron sputtering on glass substrates with the MZO targets. We investigated on the optical and electrical properties of the as-sputtered MZO films as dependences on the doping contents in the targets. All the MZO films had shown a preferred orientation in the [002] direction. As the quantity and the variety of metal dopants were changed, the crystallinity and the transmittance, as well as optical band gap were changed. The electrical resistivity was also changed with changing metal doping amounts and kinds of dopants. An epitaxial Li-doped ZnO film has a high resistivity and very smooth surface; it will have the most optimum conditions which can be used for the piezoelectric devices.

6.
Nanoscale Res Lett ; 7(1): 62, 2012 Jan 05.
Artigo em Inglês | MEDLINE | ID: mdl-22221905

RESUMO

Nitrogen-doped thiophene plasma polymer [N-ThioPP] thin films were deposited by radio frequency (13.56 MHz) plasma-enhanced chemical vapor deposition method. Thiophene was used as organic precursor (carbon source) with hydrogen gas as the precursor bubbler gas. Additionally, nitrogen gas [N2] was used as nitrogen dopant. Furthermore, additional argon was used as a carrier gas. The as-grown polymerized thin films were analyzed using ellipsometry, Fourier-transform infrared [FT-IR] spectroscopy, Raman spectroscopy, and water contact angle measurement. The ellipsometry results showed the refractive index change of the N-ThioPP film. The FT-IR spectra showed that the N-ThioPP films were completely fragmented and polymerized from thiophene.

7.
Nanoscale Res Lett ; 7(1): 89, 2012 Jan 26.
Artigo em Inglês | MEDLINE | ID: mdl-22280933

RESUMO

The hydrophilic TiO2 films were successfully deposited on slide glass substrates using titanium tetraisopropoxide as a single precursor without carriers or bubbling gases by a metal-organic chemical vapor deposition method. The TiO2 films were employed by scanning electron microscopy, Fourier transform infrared spectrometry, UV-Visible [UV-Vis] spectroscopy, X-ray diffraction, contact angle measurement, and atomic force microscopy. The temperature of the substrate was 500°C, and the temperatures of the precursor were kept at 75°C (sample A) and 60°C (sample B) during the TiO2 film growth. The TiO2 films were characterized by contact angle measurement and UV-Vis spectroscopy. Sample B has a very low contact angle of almost zero due to a superhydrophilic TiO2 surface, and transmittance is 76.85% at the range of 400 to 700 nm, so this condition is very optimal for hydrophilic TiO2 film deposition. However, when the temperature of the precursor is lower than 50°C or higher than 75°C, TiO2 could not be deposited on the substrate and a cloudy TiO2 film was formed due to the increase of surface roughness, respectively.

8.
J Nanosci Nanotechnol ; 11(8): 7315-8, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22103185

RESUMO

Recently anti-reflective films (AR) have been intensely studied. Particularly for textured silicon solar cells, the AR films can further reduce the reflection of the incident light through trapping the incident light into the cells. In this work, TiO2 anti-reflection films have been grown on the textured Si (100) substrate which is processed in two steps, and the films are deposited using metal-organic chemical vapor deposition (MOCVD) with a precursor of titanium tetra-isopropoxide (TTIP). The effect of the substrate texture and the growth conditions of TiO2 films on the reflectance has been investigated. Pyramid size of textured silicon had approximately 2-9 microm. A well-textured silicon surface can lower the reflectance to 10%. For more reduced reflection, TiO2 anti-reflection films on the textured silicon were deposited at 600 degrees C using titanium tetra-isopropoxide (TTIP) as a precursor by metal-organic chemical vapor deposition (MOCVD), and the deposited TiO2 layers were then treated by annealing for 2 h in air at 600 and 1000 degrees C, respectively. In this process, the treated samples by annealing showed anatase and rutile phases, respectively. The thickness of TiO2 films was about 75 +/- 5 nm. The reflectance at specific wavelength can be reduced to 3% in optimum layer.

9.
J Nanosci Nanotechnol ; 11(6): 5328-33, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21770184

RESUMO

Microwave (MW) plasma was applied to the surface of polyimide (PI) films as a treatment to enhance the adhesion between copper deposition layer and PI surface for electroless plating. The influences of nitrogen MW plasma treatment on chemical composition of the PI surface were investigated by using X-Ray photoelectron spectroscopy (XPS). The wettability was also investigated by water contact angle measurement. The surface morphologies of PI films before and after treatment were characterized with atomic force microscopy (AFM). The contact angle results show that was dramatically decreased to 16.1 degrees at the optimal treatment condition from 72.1 degrees (untreated PI). However, the root mean square (RMS) roughness of treated PI film was almost unchanged. The AFM roughness was stayed from 1.0 to 1.2 with/without plasma treatment. XPS data show a nitrogen increase when PI films exposed to N2 MW plasma. Electroless copper depositions were carried out with the free-formaldehyde method using glyoxylic acid as the reducing reagent and mixture palladium chloride, tin chloride as activation solution. Adhesion property between polyimide surface and copper layer was investigated by tape test.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...