Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 243
Filtrar
1.
Surg Endosc ; 38(4): 2124-2133, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38443502

RESUMO

BACKGROUND: Endoscopic full-thickness gastric resection (EFTGR) with regional lymph node dissection (LND) has been used for early gastric cancer (EGC) exceeding the indications for endoscopic submucosal dissection (ESD). The extent of the dissected lymph nodes is crucial. A 3D near-infrared (NIR) video robot system significantly enhances visualization of the lymphatic system. However, this system has not been used in EFTGR with LND. Thus, this study assessed the benefits of the 3D NIR video robot system in a clinical setting. METHODS: Between February 2015 and September 2018, 24 patients with EGC exceeding the indications for ESD were treated with EFTGR and LND using a 3D NIR video system with the da Vinci surgical robot. Indocyanine green (ICG) was injected endoscopically around the tumor, and basin node (BN) dissection around the nodes was examined using the 3D NIR video system of the da Vinci Si surgical robot. Subsequently, robot-assisted EFTGR was performed. The primary outcome was the 5-year survival rate. RESULT: During a 5-year follow-up of all 24 patients, an 80-year-old patient with an ulcer and T2 invasion was lost to follow-up. Among the remaining 23 patients, no mortality or recurrence was observed. CONCLUSION: No metastasis or mortality occurred using the da Vinci robot-assisted EFTGR with LLND and a 3D NIR video system for patients who required radical gastrectomy for EGC in over 5 years. Hence, this may be a safe and effective method for radical gastrectomy; further studies are required confirming its effectiveness.


Assuntos
Ressecção Endoscópica de Mucosa , Robótica , Neoplasias Gástricas , Humanos , Idoso de 80 Anos ou mais , Ressecção Endoscópica de Mucosa/métodos , Mucosa Gástrica/cirurgia , Excisão de Linfonodo/métodos , Linfonodos/patologia , Gastrectomia/métodos , Neoplasias Gástricas/cirurgia , Neoplasias Gástricas/patologia , Estudos Retrospectivos
2.
Surg Endosc ; 38(5): 2533-2541, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38472530

RESUMO

BACKGROUND: Endoscopic full-thickness gastric resection (EFTGR) with laparoscopic regional lymph node dissection (LLND) and endoscopic submucosal dissection (ESD) with LLND have been investigated as treatment options for early gastric cancer beyond the absolute indications for ESD. However, comparative studies on the long-term outcomes of these procedures are lacking. This study aimed to analyze and compare the 10-year outcomes of both procedures in a real clinical setting. METHODS: Between January 2009 and December 2013, 28 and 37 patients diagnosed with EGC beyond the absolute indications for ESD were treated with EFTGR with LLND and ESD with LLND, respectively. In both procedures, the dye was injected into the tumor. However, after injection and LLND, EFTGR was performed immediately in the EFTGR with LLND group, whereas LLND was followed by ESD in the ESD with LLND group. The primary endpoint was the 10-year survival rate. RESULTS: The EFTGR with LLND group had one case of local recurrence (3.6%) and mortality (3.6%) each, while the ESD with LLND group had none (0.0% for both); however, the differences were not statistically significant (P = 0.247 for each). Furthermore, there was no significant difference in complications such as ischemia and anastomosis leakage between the groups (P = 0.247). CONCLUSIONS: When the procedures were properly applied, EFTGR with LLND and ESD with LLND did not increase the 10-year mortality in patients with EGC beyond the absolute ESD indications compared with conventional radical gastrectomy.


Assuntos
Ressecção Endoscópica de Mucosa , Laparoscopia , Excisão de Linfonodo , Neoplasias Gástricas , Humanos , Neoplasias Gástricas/cirurgia , Neoplasias Gástricas/patologia , Excisão de Linfonodo/métodos , Feminino , Masculino , Laparoscopia/métodos , Pessoa de Meia-Idade , Idoso , Resultado do Tratamento , Ressecção Endoscópica de Mucosa/métodos , Estudos Retrospectivos , Gastrectomia/métodos , Gastroscopia/métodos , Taxa de Sobrevida , Recidiva Local de Neoplasia
3.
Biomater Res ; 28: 0011, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38500782

RESUMO

Background: To improve the efficiency of neural development from human embryonic stem cells, human embryoid body (hEB) generation is vital through 3-dimensional formation. However, conventional approaches still have limitations: long-term cultivation and laborious steps for lineage determination. Methods: In this study, we controlled the size of hEBs for ectodermal lineage specification using cell-penetrating magnetic nanoparticles (MNPs), which resulted in reduced time required for initial neural induction. The magnetized cells were applied to concentrated magnetic force for magnet-derived multicellular organization. The uniformly sized hEBs were differentiated in neural induction medium (NIM) and suspended condition. This neurally induced MNP-hEBs were compared with other groups. Results: As a result, the uniformly sized MNP-hEBs in NIM showed significantly improved neural inductivity through morphological analysis and expression of neural markers. Signaling pathways of the accelerated neural induction were detected via expression of representative proteins; Wnt signaling, dopaminergic neuronal pathway, intercellular communications, and mechanotransduction. Consequently, we could shorten the time necessary for early neurogenesis, thereby enhancing the neural induction efficiency. Conclusion: Overall, this study suggests not only the importance of size regulation of hEBs at initial differentiation stage but also the efficacy of MNP-based neural induction method and stimulations for enhanced neural tissue regeneration.

4.
Ear Nose Throat J ; : 1455613241234818, 2024 Feb 29.
Artigo em Inglês | MEDLINE | ID: mdl-38424695

RESUMO

Objective: To analyze changes in olfactory function after endoscopic endonasal skull base surgery and compare performance of the olfactory questionnaire with those of conventional psychophysical tests. Methods: Patients were classified into 5 categories for olfactory function evaluation (normal, mild hyposmia, moderate hyposmia, severe hyposmia, and anosmia) based on a self-assessment. Patients also underwent the butanol threshold test (BTT), Cross-Cultural Smell Identification Test (CCSIT), and 11-item olfactory questionnaire. Subjects with normosmia preoperatively and who were followed up at least 6 months after surgery were analyzed. Receiver operating characteristic curves and confusion matrix analysis were performed for BTT, CCSIT, and olfactory questionnaire to compare their diagnostic abilities. The effects of age, preoperative olfaction, septal flap, tumor pathology, and tumor size on postoperative olfaction were evaluated using multivariate linear regression analysis. Results: Data from 108 patients were analyzed. Postoperative changes in the olfactory questionnaire were significantly associated with changes in the BTT and CCSIT. The area under the curve for postoperative self-olfactory function classification was highest for olfactory questionnaire (0.894), followed by BTT (0.767) and CCSIT (0.688). Patient age at the time of surgery and preoperative BTT score were significantly related to postoperative olfactory outcomes. Conclusion: The olfactory questionnaire correlated well with conventional psychosomatic olfactory function tests. In combination with clinical parameters and preoperative psychosomatic olfactory function tests, the olfactory questionnaire is suitable for assessing subjective olfactory function after endoscopic endonasal skull base surgery.

5.
Laryngoscope Investig Otolaryngol ; 9(1): e1206, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38362197

RESUMO

Objectives: This study aimed to evaluate the characteristics and treatment outcomes of inverted papillomas involving the frontal sinus. Methods: Patients treated for inverted papilloma involving the frontal sinus between 2003 and 2020 were reviewed. Tumors were classified based on their extent (Extent 1: partially encroaching on the frontal sinus; Extent 2: completely filling the frontal sinus; Extent 3: eroding bony borders beyond the frontal sinus) and site of origin (Origin 1: originating outside the frontal sinus and prolapsing into the frontal sinus; Origin 2: originating from the frontal sinus walls medial to the vertical plane of the lamina papyracea; Origin 3: originating from the frontal sinus walls lateral to the vertical plane of the lamina papyracea). Treatment outcomes including tumor recurrence and patency of the frontal recess were analyzed according to tumor characteristics and surgical treatment modalities. Results: A total of 49 surgical cases were analyzed. Extent 1 were the most common type (n = 27), followed by Extent 2 (n = 15), and Extent 3 (n = 7). The most common sites of origin were Origin 1 (n = 23), followed by Origin 2 (n = 15), and Origin 3 (n = 11). Overall, there were nine recurrences (18.4%). Recurrence was not associated with tumor extent, whereas tumor origin, particularly Origin 3 was associated with higher recurrence; 1/23 (4.3%) for Origin 1, 3/15 (20.0%) for Origin 2, and 5/11 (45.5%) for Origin 3 (Log-rank p < .001). Draf III frontal sinusotomy was associated with in the highest patency rate (84.6%) during the follow-up. Conclusion: The recurrence rate of frontal sinus inverted papilloma depends on tumor origin rather than the extent of the tumor. In particular, lesions originating from the frontal sinus lateral to the lamina papyracea recur frequently. Draf III frontal sinusotomy can achieve patent frontal recess allowing active surveillance. Level of Evidence: IV.

6.
Artigo em Inglês | MEDLINE | ID: mdl-38404243

RESUMO

Objectives: Due to the rarity of olfactory neuroblastoma (ONB), there is an ongoing debate about optimal treatment strategies, especially for early staged or locally advanced cases. Therefore, our study aims to explore experiences from multiple centers, focusing on factors that influence the oncological outcomes of ONB. Methods: We retrospectively analyzed 195 ONB patients treated at nine tertiary hospitals in South Korea between December 1992 and December 2019. Kaplan-Meier survival analysis was used to evaluate oncological outcomes, and the Cox proportional hazards regression model was employed to analyze prognostic factors for survival outcomes. Furthermore, we conducted 1:1 nearest-neighbor matching to investigate differences in clinical outcomes according to the use of neoadjuvant chemotherapy. Results: In our cohort, the 5-year overall survival rate (OS) was 78.6%, and the 5-year disease-free survival rate (DFS) was 62.4%. The Cox proportional hazards model revealed that the mKadish stage and Dulguerov T status were significant for DFS, while the mKadish stage and Hyams grade were identified as prognostic factors for OS. The subgroup analyses indicated a trend toward improved 5-year DFS with dural resection in mKadish A and B cases, even though that result was statistically insignificant. Induction chemotherapy did not provide a survival benefit in this study after matching for the mKadish stage and nodal status. Conclusion: Clinical staging and pathologic grading are important prognostic factors in ONB. Dural resection in mKadish A and B did not show a significant survival benefit. Induction chemotherapy did not show a survival benefit, even after stage matching.

7.
Polymers (Basel) ; 16(2)2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-38257033

RESUMO

The integration of nanoparticles (NPs) into molecular self-assemblies has been extensively studied with the aim of building well-defined, ordered structures which exhibit advanced properties and performances. This study demonstrates a novel strategy for the preparation of a spike-like self-assembly designed to enhance UV blocking. Poly(2-hydroxyethyl aspartamide) (PHEA) substituted with octadecyl chains and menthyl anthranilate (C18-M-PHEA) was successfully synthesized by varying the number of grafted groups to control their morphology and UV absorption. The in situ incorporation of polymerized rod-like TiO2 within the C18-M-PHEA self-aggregates generated spike-like self-assemblies (TiO2@C18-M-PHEA) with a chestnut burr structure in aqueous solution. The results showed that the spike-like self-assemblies integrated with TiO2 NPs exhibited a nine-fold increase in UV protection by simultaneous UV absorption and scattering compared with the pure TiO2 NPs formed via a bulk mixing process. This work provides a novel method for UV protection using self-assembling poly(amino acid)s derivatives integrated with functional nanoparticles to tune their morphology and organization.

8.
Autophagy ; 20(2): 365-379, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-37712850

RESUMO

Cerebral ischemia induces massive mitochondrial damage, leading to neuronal death. The elimination of damaged mitochondria via mitophagy is critical for neuroprotection. Here we show that the level of PA2G4/EBP1 (proliferation-associated 2G4) was notably increased early during transient middle cerebral artery occlusion and prevented neuronal death by eliciting cerebral ischemia-reperfusion (IR)-induced mitophagy. Neuron-specific knockout of Pa2g4 increased infarct volume and aggravated neuron loss with impaired mitophagy and was rescued by introduction of adeno-associated virus serotype 2 expressing PA2G4/EBP1. We determined that PA2G4/EBP1 is ubiquitinated on lysine 376 by PRKN/PARKIN on the damaged mitochondria and interacts with receptor protein SQSTM1/p62 for mitophagy induction. Thus, our study suggests that PA2G4/EBP1 ubiquitination following cerebral IR-injury promotes mitophagy induction, which may be implicated in neuroprotection.Abbreviations: AAV: adeno-associated virus; ACTB: actin beta; BNIP3L/NIX: BCL2 interacting protein 3 like; CA1: Cornu Ammonis 1; CASP3: caspase 3; CCCP: carbonyl cyanide m-chlorophenyl hydrazone; DMSO: dimethyl sulfoxide; PA2G4/EBP1: proliferation-associated 2G4; FUNDC1: FUN14 domain containing 1; IB: immunoblotting; ICC: immunocytochemistry; IHC: immunohistochemistry; IP: immunoprecipitation; MCAO: middle cerebral artery occlusion; MEF: mouse embryonic fibroblast; OGD: oxygen-glucose deprivation; PRKN/PARKIN: parkin RBR E3 ubiquitin protein ligase; PINK1: PTEN induced kinase 1; RBFOX3/NeuN: RNA binding fox-1 homolog 3; SQSTM1/p62: sequestosome 1; TIMM23: translocase of inner mitochondrial membrane 23; TOMM20: translocase of outer mitochondrial membrane 20; TUBB: tubulin beta class I; WT: wild-type.


Assuntos
Isquemia Encefálica , Mitofagia , Animais , Camundongos , Mitofagia/genética , Proteína Sequestossoma-1/metabolismo , Infarto da Artéria Cerebral Média , Autofagia , Proteínas Quinases/metabolismo , Fibroblastos/metabolismo , Ubiquitinação , Ubiquitina-Proteína Ligases/metabolismo , Proteínas de Membrana/metabolismo , Proteínas Mitocondriais/metabolismo
9.
Sleep Breath ; 28(1): 1-9, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37421520

RESUMO

PURPOSE: Snoring is the most common symptom of obstructive sleep apnea. Various objective methods of measuring snoring are available, and even if the measurement is performed the same way, communication is difficult because there are no common reference values between the researcher and clinician with regard to intensity and frequency, among other variables. In other words, no consensus regarding objective measurement has been reached. This study aimed to review the literature related to the objective measurement of snoring, such as measurement devices, definitions, and device locations. METHODS: A literature search based on the PubMed, Cochrane, and Embase databases was conducted from the date of inception to April 5, 2023. Twenty-nine articles were included in this study. Articles that mentioned only the equipment used for measurement and did not include individual details were excluded from the study. RESULTS: Three representative methods for measuring snoring emerged. These include (1) a microphone, which measures snoring sound; (2) piezoelectric sensor, which measures snoring vibration; and (3) nasal transducer, which measures airflow. In addition, recent attempts have been made to measure snoring using smartphones and applications. CONCLUSION: Numerous studies have investigated both obstructive sleep apnea and snoring. However, the objective methods of measuring snoring and snoring-related concepts vary across studies. Consensus in the academic and clinical communities on how to measure and define snoring is required.


Assuntos
Apneia Obstrutiva do Sono , Ronco , Humanos , Polissonografia/métodos , Som , Vibração
10.
JAMA Otolaryngol Head Neck Surg ; 150(1): 22-29, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-37971771

RESUMO

Importance: Consumer-level sleep analysis technologies have the potential to revolutionize the screening for obstructive sleep apnea (OSA). However, assessment of OSA prediction models based on in-home recording data is usually performed concurrently with level 1 in-laboratory polysomnography (PSG). Establishing the predictability of OSA using sound data recorded from smartphones based on level 2 PSG at home is important. Objective: To validate the performance of a prediction model for OSA using breathing sound recorded from smartphones in conjunction with level 2 PSG at home. Design, Setting, and Participants: This diagnostic study followed a prospective design, involving participants who underwent unattended level 2 home PSG. Breathing sounds were recorded during sleep using 2 smartphones, one with an iOS operating system and the other with an Android operating system, simultaneously with home PSG in participants' own home environment. Participants were 19 years and older, slept alone, and had either been diagnosed with OSA or had no previous diagnosis. The study was performed between February 2022 and February 2023. Main Outcomes and Measures: Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of the predictive model based on the recorded breathing sounds. Results: Of the 101 participants included during the study duration, the mean (SD) age was 48.3 (14.9) years, and 51 (50.5%) were female. For the iOS smartphone, the sensitivity values at apnea-hypopnea index (AHI) levels of 5, 15, and 30 per hour were 92.6%, 90.9%, and 93.3%, respectively, with specificities of 84.3%, 94.4%, and 94.4%, respectively. Similarly, for the Android smartphone, the sensitivity values at AHI levels of 5, 15, and 30 per hour were 92.2%, 90.0%, and 92.9%, respectively, with specificities of 84.0%, 94.4%, and 94.3%, respectively. The accuracy for the iOS smartphone was 88.6%, 93.3%, and 94.3%, respectively, and for the Android smartphone was 88.1%, 93.1%, and 94.1% at AHI levels of 5, 15, and 30 per hour, respectively. Conclusions and Relevance: This diagnostic study demonstrated the feasibility of predicting OSA with a reasonable level of accuracy using breathing sounds obtained by smartphones during sleep at home.


Assuntos
Apneia Obstrutiva do Sono , Smartphone , Humanos , Feminino , Pessoa de Meia-Idade , Masculino , Polissonografia , Sons Respiratórios , Apneia Obstrutiva do Sono/diagnóstico , Sono
11.
Nat Biomed Eng ; 2023 Oct 30.
Artigo em Inglês | MEDLINE | ID: mdl-37903901

RESUMO

The high stiffness of intravenous needles can cause tissue injury and increase the risk of transmission of blood-borne pathogens through accidental needlesticks. Here we describe the development and performance of an intravenous needle whose stiffness and shape depend on body temperature. The needle is sufficiently stiff for insertion into soft tissue yet becomes irreversibly flexible after insertion, adapting to the shape of the blood vessel and reducing the risk of needlestick injury on removal, as we show in vein phantoms and ex vivo porcine tissue. In mice, the needles had similar fluid-delivery performance and caused substantially less inflammation than commercial devices for intravenous access of similar size. We also show that an intravenous needle integrated with a thin-film temperature sensor can monitor core body temperature in mice and detect fluid leakage in porcine tissue ex vivo. Temperature-responsive intravenous needles may improve patient care.

12.
Clin Exp Otorhinolaryngol ; 16(4): 359-368, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37641857

RESUMO

OBJECTIVES: Several criteria exist for classifying chronic rhinosinusitis with nasal polyps (CRSwNP) as eosinophilic or non-eosinophilic. This study attempted to evaluate several criteria for defining eosinophilic CRSwNP from clinical and immunological perspectives. METHODS: A cohort of 84 patients (73 patients with CRSwNP and 11 control patients) was retrospectively analyzed. Patients were divided into eosinophilic and non-eosinophilic CRSwNP based on four different criteria: eosinophils (EOS) accounting for more than 20% of the total inflammatory cells; ≥70 EOS per high-power field (HPF); >55 EOS/HPF; and ≥10 EOS/HPF. Preoperative clinical characteristics, the immunological profiles of 14 cytokines from nasal tissue, and postoperative outcomes were compared between eosinophilic and non-eosinophilic CRSwNP based on each criterion. These criteria were immunologically validated by using 14 cytokines to predict the performance of tissue eosinophilia with a random forest model. RESULTS: Patients with eosinophilic CRSwNP were significantly older when the criterion of ≥10 EOS/HPF or EOS >20% was used. The number of patients with aspirin intolerance was significantly higher in eosinophilic CRSwNP based on the criterion of EOS >20%. From an immunological perspective, non-type 2 inflammatory cytokines were significantly higher in non-eosinophilic CRSwNP with the criterion of EOS >20% of the total inflammatory cells. In addition, the criterion of EOS >20% of the total inflammatory cells resulted in the best prediction of eosinophilic CRSwNP, with an accuracy of 88.10% and area under the curve of 0.94. CONCLUSION: Clinical and immunological characteristics were different between eosinophilic and non-eosinophilic CRSwNP depending on a variety of criteria, and the. RESULTS: of this study should be taken into account when choosing the criterion for defining eosinophilic CRSwNP and interpreting the data accordingly.

13.
Clin Orthop Surg ; 15(3): 444-453, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37274492

RESUMO

Background: Laminoplasty is a common and effective surgery for decompression of the spinal cord in multilevel cervical myelopathy. The midline splitting technique (MST) and the unilateral open door technique (UODT) are the two most commonly performed laminoplasty techniques with continuous debate on which is preferable. This study aimed to add light to the matter by comparing and exploring the possible causes of different outcomes. Methods: A total of 101 patients who underwent laminoplasty for degenerative cervical myelopathy were included in this study. Radiographic measurements including C2-7 Cobb angle, C2-7 range of motion (ROM), Pavlov ratio of the most compressed level, and canal area with diameter were compared. Modified Japanese Orthopedic Association (mJOA) score and complications including C5 palsy, axial neck pain, hinge fractures, and spacer displacement were also compared. Statistical analysis was performed using independent samples t-test, chi-square test, Fisher's exact test, and linear mixed model. Results: C2-7 ROM, canal diameter, Pavlov ratio, and mJOA score did not demonstrate differences between the two techniques. The UODT group had greater postoperative canal expansion but had more loss of C2-7 lordosis than did the MST group. Of the complications, hinge fractures were more common in the UODT group, with more loss of C2-7 lordosis in patients with hinge fractures. On the other hand, spacer displacement occurred only in the MST group, with lesser canal expansion in patients with spacer displacement. Conclusions: The two laminoplasty techniques both demonstrated effectiveness in treating patients with multilevel cervical myelopathy. However, care should be given to avoid hinge fractures and spacer displacement since both can possibly lead to unfavorable outcomes.


Assuntos
Laminoplastia , Humanos , Vértebras Cervicais/diagnóstico por imagem , Vértebras Cervicais/cirurgia , Laminoplastia/efeitos adversos , Laminoplastia/métodos , Lordose , Estudos Retrospectivos , Doenças da Medula Espinal/diagnóstico por imagem , Doenças da Medula Espinal/cirurgia , Resultado do Tratamento
14.
Heliyon ; 9(5): e15945, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37223703

RESUMO

Background: Oxidative stress is considered as one of the main causes of Parkinson's disease (PD), however the exact etiology of PD is still unknown. Although it is known that Proviral Integration Moloney-2 (PIM2) promotes cell survival by its ability to inhibit formation of reactive oxygen species (ROS) in the brain, the precise functional role of PIM2 in PD has not been fully studied yet. Objective: We investigated the protective effect of PIM2 against apoptosis of dopaminergic neuronal cells caused by oxidative stress-induced ROS damage by using the cell permeable Tat-PIM2 fusion protein in vitro and in vivo. Methods: Transduction of Tat-PIM2 into SH-SY5Y cells and apoptotic signaling pathways were determined by Western blot analysis. Intracellular ROS production and DNA damage was confirmed by DCF-DA and TUNEL staining. Cell viability was determined by MTT assay. PD animal model was induced by 1-methyl-4-phenyl-1,2,3,6-tetrahydropyridine (MPTP) and protective effects were examined using immunohistochemistry. Results: Transduced Tat-PIM2 inhibited the apoptotic caspase signaling and reduced the production of ROS induced by 1-methyl-4-phenylpyridinium (MPP+) in SH-SY5Y cells. Furthermore, we confirmed that Tat-PIM2 transduced into the substantia nigra (SN) region through the blood-brain barrier and this protein protected the Tyrosine hydroxylase-positive cells by observation of immunohistostaining. Tat-PIM2 also regulated antioxidant biomolecules such as SOD1, catalase, 4-HNE, and 8-OHdG which reduce the formation of ROS in the MPTP-induced PD mouse model. Conclusion: These results indicated that Tat-PIM2 markedly inhibited the loss of dopaminergic neurons by reducing ROS damage, suggesting that Tat-PIM2 might be a suitable therapeutic agent for PD.

15.
Allergy Asthma Immunol Res ; 15(4): 437-450, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37075796

RESUMO

PURPOSE: Cluster analyses on inflammatory markers of chronic rhinosinusitis (CRS) in Asians from multicenter data are lacking. This multicenter study aimed to identify the endotypes of CRS in Koreans and to evaluate the relationship between the endotypes and clinical parameters. METHODS: Nasal tissues were obtained from patients with CRS and controls who underwent surgery. The endotypes of CRS were investigated by measuring interleukin (IL)-5, interferon (IFN)-γ, IL-17A, IL-22, IL-1ß, IL-6, IL-8, matrix metalloproteinase-9, eotaxin-3, eosinophil cationic protein, myeloperoxidase (MPO), human neutrophil elastase (HNE), periostin, transforming growth factor-ß1, total immunoglobulin E (IgE), and staphylococcal enterotoxin (SE)-specific IgE. We performed hierarchical cluster analysis and evaluated the phenotype, comorbidities, and Lund-Mackay computed tomography (LM CT) score in each cluster. RESULTS: Five clusters and 3 endotypes were extracted from 244 CRS patients: cluster 1 had no upregulated mediators compared to the other clusters (mild mixed inflammatory CRS); clusters 2, 3, and 4 had higher concentrations of neutrophil-associated mediators including HNE, IL-8, IL-17A, and MPO (T3 CRS); and cluster 5 had higher levels of eosinophil-associated mediators (T2 CRS). SE-specific IgE was undetectable in T3 CRS and had low detectable levels (6.2%) even in T2 CRS. The CRS with nasal polyps (CRSwNP) phenotype and LM CT scores showed no significant differences between T2 and T3 CRS, while the incidence of comorbid asthma was higher in T2 CRS than T3 CRS. In T3 clusters, higher levels of neutrophilic markers were associated with disease severity and CRSwNP phenotype. CONCLUSIONS: In Koreans, there is a distinct T3 CRS endotype showing a high proportion of CRSwNP and severe disease extent, along with T2 CRS.

16.
Clin Exp Otorhinolaryngol ; 16(2): 159-164, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36916031

RESUMO

OBJECTIVES: Systemic inflammation plays a key role in the pathogenesis of obstructive sleep apnea (OSA); however, easy-to-use methods to evaluate the severity of systemic inflammation have yet to be developed. This study investigated the association between systemic inflammation markers that could be derived from the complete blood count (CBC) profile and sleep parameters in a large number of patients with OSA. METHODS: Patients who visited our hospital's Otorhinolaryngology Sleep Clinic between January 2017 and April 2022 underwent polysomnography and routine laboratory tests, including a CBC. Associations between three systemic inflammatory markers-the systemic immune-inflammation index (SII), neutrophil-lymphocyte ratio (NLR), and platelet-lymphocyte ratio (PLR)-and polysomnographic and demographic factors including age, sex, body mass index, the apnea-hypopnea index (AHI), the hypopnea index (HI), lowest oxygen saturation (%), the Pittsburgh Sleep Quality Index (PSQI), the Epworth Sleepiness Scale, and percentages of non-rapid eye movement (REM) sleep stage 3, REM sleep, and snoring time were analyzed. The inflammation markers were compared among OSA subgroups, and associations were also analyzed in subgroups with different OSA severities. RESULTS: In total, 1,102 patients (968 men and 134 women) were included, and their mean AHI was 33.0±24.3. PSQI was significantly associated with SII (P=0.027). No independent significant factors were identified for the NLR or PLR. Within the simple snoring and mild OSA subgroups, no significant association was found between sleep parameters and the SII. In the severe OSA subgroup, the AHI (P=0.004) and PSQI (P=0.012) were independently associated with the SII. CONCLUSION: Our study analyzed systemic inflammatory markers based on the CBC, a simple, relatively cost-effective test, and showed that the AHI and SII were significantly correlated only in the severe OSA subgroup.

18.
BMB Rep ; 56(4): 234-239, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36571143

RESUMO

Thioredoxin-like protein 1 (TXNL1), one of the thioredoxin superfamily known as redox-regulator, plays an essential in maintaining cell survival via various antioxidant and anti-apoptotic mechanisms. It is well known that relationship between ischemia and oxidative stress, however, the role of TXNL1 protein in ischemic damage has not been fully investigated. In the present study, we aimed to determine the protective role of TXNL1 against on ischemic injury in vitro and in vivo using cell permeable Tat-TXNL1 fusion protein. Transduced Tat-TXNL1 inhibited ROS production and cell death in H2O2-exposed hippocampal neuronal (HT-22) cells and modulated MAPKs and Akt activation, and pro-apoptotic protein expression levels in the cells. In an ischemia animal model, Tat-TXNL1 markedly decreased hippocampal neuronal cell death and the activation of astrocytes and microglia. These findings indicate that cell permeable Tat-TXNL1 protects against oxidative stress in vitro and in vivo ischemic animal model. Therefore, we suggest Tat-TXNL1 can be a potential therapeutic protein for ischemic injury. [BMB Reports 2023; 56(4): 234-239].


Assuntos
Lesões Encefálicas , Peróxido de Hidrogênio , Animais , Peróxido de Hidrogênio/farmacologia , Linhagem Celular , Apoptose , Estresse Oxidativo , Produtos do Gene tat/metabolismo , Isquemia , Tiorredoxinas/genética , Tiorredoxinas/metabolismo , Proteínas Recombinantes de Fusão/genética , Proteínas Recombinantes de Fusão/farmacologia , Proteínas Recombinantes de Fusão/metabolismo
20.
Adv Mater ; 34(44): e2204805, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36190163

RESUMO

Robotic skin with human-skin-like sensing ability holds immense potential in various fields such as robotics, prosthetics, healthcare, and industries. To catch up with human skin, numerous studies are underway on pressure sensors integrated on robotic skin to improve the sensitivity and detection range. However, due to the trade-off between them, existing pressure sensors have achieved only a single aspect, either high sensitivity or wide bandwidth. Here, an adaptive robotic skin is proposed that has both high sensitivity and broad bandwidth with an augmented pressure sensing ability beyond the human skin. A key for the adaptive robotic skin is a tunable pressure sensor built with uniform gallium microgranules embedded in an elastomer, which provides large tuning of the sensitivity and the bandwidth, excellent sensor-to-sensor uniformity, and high reliability. Through the mode conversion based on the solid-liquid phase transition of gallium microgranules, the sensor provides 97% higher sensitivity (16.97 kPa-1 ) in the soft mode and 262.5% wider bandwidth (≈1.45 MPa) in the rigid mode compared to the human skin. Successful demonstration of the adaptive robotic skin verifies its capabilities in sensing a wide spectrum of pressures ranging from subtle blood pulsation to body weight, suggesting broad use for various applications.


Assuntos
Gálio , Percepção do Tato , Humanos , Reprodutibilidade dos Testes , Pele , Tato
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...