Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Radiat Prot Dosimetry ; 155(2): 236-40, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23230217

RESUMO

The linear attenuation coefficient is an important factor in the correction of self-attenuation. In this study, a cone beam from a source of ∼1 µCi was utilised, not equipped with the collimator, and a complete geometric configuration was mathematically modelled. Samples of NaCl, Na2CO3 and (NH4)2SO4 were used to verify the mathematical model. The linear attenuation coefficient can be calculated within ∼4 % of difference in the cylindrical sample at energies of 59.5, 121.8, 244.7, 344.2 and 444.0 keV.


Assuntos
Sulfato de Amônio/química , Carbonatos/química , Modelos Teóricos , Cloreto de Sódio/química , Espectrometria gama/instrumentação , Raios gama , Fótons , Espalhamento de Radiação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...