Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Breath Res ; 18(2)2024 Jan 18.
Artigo em Inglês | MEDLINE | ID: mdl-38176080

RESUMO

When attempts to lose body fat mass frequently fail, breath acetone (BA) monitoring may assist fat mass loss during a low-carbohydrate diet as it can provide real-time body fat oxidation levels. This randomized controlled study aimed to evaluate the effectiveness of monitoring BA levels and providing feedback on fat oxidation during a three-week low-carbohydrate diet intervention. Forty-seven participants (mean age = 27.8 ± 4.4 years, 53.3% females, body mass index = 24.1 ± 3.4 kg m-2) were randomly assigned to three groups (1:1:1 ratio): daily BA assessment with a low-carbohydrate diet, body weight assessment (body scale (BS)) with a low-carbohydrate diet, and low-carbohydrate diet only. Primary outcome was the change in fat mass and secondary outcomes were the changes in body weight and body composition. Forty-five participants completed the study (compliance rate: 95.7%). Fat mass was significantly reduced in all three groups (allP< 0.05); however, the greatest reduction in fat mass was observed in the BA group compared to the BS (differences in changes in fat mass, -1.1 kg; 95% confidence interval: -2.3, -0.2;P= 0.040) and control (differences in changes in fat mass, -1.3 kg; 95% confidence interval: -2.1, -0.4;P= 0.013) groups. The BA group showed significantly greater reductions in body weight and visceral fat mass than the BS and control groups (allP< 0.05). In addition, the percent body fat and skeletal muscle mass were significantly reduced in both BA and BS groups (allP< 0.05). However, no significant differences were found in changes in body fat percentage and skeletal muscle mass between the study groups. Monitoring BA levels, which could have motivated participants to adhere more closely to the low-carbohydrate diet, to assess body fat oxidation rates may be an effective intervention for reducing body fat mass (compared to body weight assessment or control conditions). This approach could be beneficial for individuals seeking to manage body fat and prevent obesity.


Assuntos
Acetona , Redução de Peso , Feminino , Humanos , Adulto Jovem , Adulto , Masculino , Testes Respiratórios , Composição Corporal/fisiologia , Peso Corporal , Tecido Adiposo
2.
J Int Soc Sports Nutr ; 20(1): 2264278, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37791478

RESUMO

OBJECTIVE: We examined the effects of short-term KD on exercise efficiency and hormonal response during and after the graded exercise testing. METHODS: Fourteen untrained healthy adults (8 males, 6 females, age 26.4 ± 3.1 [SD] years; BMI 24.8 ± 4.6 kg/m2; peak VO2max 54.0 ± 5.8 ml/kg FFM/min) completed 3-days of a mixed diet (MD) followed by another 3-days of KD after 3-days of washout period. Upon completion of each diet arm, participants underwent graded exercise testing with low- (LIE; 40% of VO2max), moderate- (MIE; 55%), and high-intensity exercise (HIE; 70%). Exercise efficiency was calculated as work done (kcal/min)/energy expenditure (kcal/min). RESULTS: Fat oxidation during the recovery period was higher in KD vs. MD. Despite identical workload during HIE, participants after having KD vs. MD showed higher energy expenditure and lower exercise efficiency (10.1 ± 0.7 vs. 12.5 ± 0.3%, p < .01). After KD, free fatty acid (FFA) concentrations were higher during MIE and recovery vs. resting, and beta-hydroxybutylate (BOHB) was lower at HIE vs. resting. Cortisol concentrations after KD was higher during recovery vs. resting, with no significant changes during graded exercise testing after MD. CONCLUSIONS: Our data suggest that short-term KD is favorable to fat metabolism leading increased circulating FFA and BOHB during LIE to MIE. However, it is notable that KD may cause 1) exercise inefficiency manifested by increased energy expenditure and 2) elevated exercise stress during HIE and recovery. Trial registration: KCT0005172, International Clinical Trials Registry Platform.


Assuntos
Dieta Cetogênica , Adulto , Feminino , Humanos , Masculino , Adulto Jovem , Metabolismo Energético , Exercício Físico/fisiologia , Teste de Esforço , Oxirredução
3.
Sensors (Basel) ; 22(5)2022 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-35271202

RESUMO

We report a breath hydrogen analyzer based on Pd-coated SnO2 nanorods (Pd-SnO2 NRs) sensor integrated into a miniaturized gas chromatography (GC) column. The device can measure a wide range of hydrogen (1-100 ppm), within 100 s, using a small volume of human breath (1 mL) without pre-concentration. Especially, the mini-GC integrated with Pd-SnO2 NRs can detect 1 ppm of H2, as a lower detection limit, at a low operating temperature of 152 °C. Furthermore, when the breath hydrogen analyzer was exposed to a mixture of interfering gases, such as carbon dioxide, nitrogen, methane, and acetone, it was found to be capable of selectively detecting only H2. We found that the Pd-SnO2 NRs were superior to other semiconducting metal oxides that lack selectivity in H2 detection. Our study reveals that the Pd-SnO2 NRs integrated into the mini-GC device can be utilized in breath hydrogen analyzers to rapidly and accurately detect hydrogen due to its high selectivity and sensitivity.


Assuntos
Hidrogênio , Nanotubos , Acetona/análise , Testes Respiratórios/métodos , Gases/análise , Humanos , Hidrogênio/química
4.
Ultrason Sonochem ; 84: 105956, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35190351

RESUMO

In this study, we introduce cobalt (Co)-doped zinc oxide (ZnO) spherical beads (SBs), synthesized using a sonochemical process, and their utilization for an acetone sensor that can be applied to an exhalation diagnostic device. The sonochemically synthezied Co-doped ZnO SBs were polycrystalline phases with sizes of several hundred nanometers formed by the aggregation of ZnO nanocrystals. As the Co doping concentration increased, the amount of substitutionally doped Co2+ in the ZnO nanocrystals increased, and we observed that the fraction of Co3+ in the Co-doped ZnO SBs increased while the fraction of oxygen vacancies decreased. At an optimal Co-doping concentration of 2 wt%, the sensor operating temperature decreased from 300 to 250 °C, response to 1 ppm acetone improved from 3.3 to 7.9, and minimum acetone detection concentration was measured at 43 ppb (response, 1.75). These enhancements are attributed to the catalytic role of Co3+ in acetone oxidation. Finally, a sensor fabricated using 2 wt% Co-doped ZnO SBs was installed in a commercially available exhalation diagnostic device to successfully measure the concentration of acetone in 1 ml of exhaled air from a healthy adult, returning a value of 0.44 ppm.


Assuntos
Nanopartículas , Óxido de Zinco , Acetona , Cobalto/química , Nanopartículas/química , Zinco , Óxido de Zinco/química
5.
ACS Sens ; 6(9): 3195-3203, 2021 09 24.
Artigo em Inglês | MEDLINE | ID: mdl-34260223

RESUMO

For extremely sensitive acetone sensors, here, we introduced an alcohol-assisted surfactant-free Langmuir-Blodgett process to rapidly assemble a single-layered two-dimensional (2D) network as a suitable percolation strategy of metal oxide semiconductor nanomaterials. The single-layered 2D network formation mechanism was investigated using zinc oxide (ZnO) nanobeads (NBs). Furthermore, the correlation between the response of the gas sensor and the average percolation number of the ZnO NBs, controlled by multi-stacking the 2D network, was investigated. It was inferred that a reduction in the number of percolations led to maximization of the response. Additionally, the versatility of the optimal percolation strategy was experimentally verified by confirming similar results to that achieved with ZnO NBs when utilizing different sizes, shapes, and compositions of metal oxides. Finally, the practical effectiveness of our extremely sensitive strategy was solidified by illustrating the response enhancement in a commercial exhalation diagnostic system that measures the amount of acetone in only 1 mL of exhalation.


Assuntos
Nanoestruturas , Óxidos
6.
Sensors (Basel) ; 20(23)2020 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-33271990

RESUMO

The purpose of our study was to validate a newly developed breath acetone (BrAce) analyzer, and to explore if BrAce could predict aerobic exercise-related substrate use. Six healthy men ran on a treadmill at 70% of maximal oxygen consumption (VO2max) for 1 h after two days of a low-carbohydrate diet. BrAce and blood ketone (acetoacetate (ACAC), beta-hydroxybutyrate (BOHB)) levels were measured at baseline and at different time points of post-exercise. BrAce values were validated against blood ketones and respiratory exchange ratio (RER). Our results showed that BrAce was moderately correlated with BOHB (r = 0.68, p < 0.01), ACAC (r = 0.37, p < 0.01) and blood ketone (r = 0.60, p < 0.01), suggesting that BrAce reflect blood ketone levels, which increase when fat is oxidized. Furthermore, BrAce also negatively correlated with RER (r = 0.67, p < 0.01). In our multiple regression analyses, we found that when BMI and VO2max were added to the prediction model in addition to BrAce, R2 values increased up to 0.972 at rest and 0.917 at 1 h after exercise. In conclusion, BrAce level measurements of our BrAce analyzer reflect blood ketone levels and the device could potentially predict fat oxidation.


Assuntos
Acetona , Testes Respiratórios , Gastos em Saúde , Ácido 3-Hidroxibutírico , Metabolismo Energético , Exercício Físico , Humanos , Masculino , Oxirredução , Consumo de Oxigênio
7.
J Breath Res ; 6(1): 017101, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22368249

RESUMO

The objective of this study is to standardize protocols for clinical research into oral malodor caused by volatile sulfur compounds (VSCs). To detect VSCs, a gas chromatograph (GC) using a flame photometric detector equipped with a bandpass filter (at 393 nm) is the gold standard (sensitivity: 5 × 10(-11) gS s(-1)). The baselines of VSC concentrations in mouth air varied considerably over a week. When the subjects refrained from eating, drinking and oral hygiene including mouth rinsing, the VSC concentrations remained constant until eating. Over a 6 h period after a meal, VSC concentrations decreased dramatically (p < 0.01). These results point to optimal times and conditions for sampling subjects. Several portable devices were compared with the measurements by the GCs. Portable GCs demonstrated capabilities similar to those of the GCs. We also applied the recommended protocols described below to clinical research testing the efficacy of ZnCl(2) products, and confirmed that using the recommended protocols in a randomized crossover design would provide very clear results. Proposed protocols include: (a) a short-term study rather than a long-term study is strongly recommended, since the VSC concentrations are constant in the short term; (b) a crossover study would be the best design to avoid the effects of individual specificities on each clinical intervention; (c) measurements of VSCs should preferably be carried out using either a GC or portable GCs.


Assuntos
Pesquisa Biomédica/normas , Testes Respiratórios/métodos , Protocolos Clínicos/normas , Halitose/diagnóstico , Compostos de Enxofre/análise , Cromatografia Gasosa , Humanos , Boca , Higiene Bucal
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...