Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 39
Filtrar
1.
ACS Nano ; 18(20): 12781-12794, 2024 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-38733343

RESUMO

Circulating tumor DNA (ctDNA) detection has been acknowledged as a promising liquid biopsy approach for cancer diagnosis, with various ctDNA assays used for early detection and treatment monitoring. Dispersible magnetic nanoparticle-based electrochemical detection methods have been proposed as promising candidates for ctDNA detection based on the detection performance and features of the platform material. This study proposes a nanoparticle surface-localized genetic amplification approach by integrating Fe3O4-Au core-shell nanoparticles into polymerase chain reactions (PCR). These highly dispersible and magnetically responsive superparamagnetic nanoparticles act as nano-electrodes that amplify and accumulate target ctDNA in situ on the nanoparticle surface upon PCR amplification. These nanoparticles are subsequently captured and subjected to repetitive electrochemical measurements to induce reconfiguration-mediated signal amplification for ultrasensitive (∼3 aM) and rapid (∼7 min) metastatic breast cancer ctDNA detection in vitro. The detection platform can also detect metastatic biomarkers from in vivo samples, highlighting the potential for clinical applications and further expansion to rapid and ultrasensitive multiplex detection of various cancers.


Assuntos
DNA Tumoral Circulante , Eletrodos , Humanos , DNA Tumoral Circulante/sangue , DNA Tumoral Circulante/genética , Biópsia Líquida , Amplificação de Genes , Nanopartículas de Magnetita/química , Neoplasias da Mama/sangue , Neoplasias da Mama/diagnóstico , Neoplasias da Mama/patologia , Neoplasias da Mama/genética , Ouro/química , Propriedades de Superfície , Técnicas Eletroquímicas/métodos , Reação em Cadeia da Polimerase , Feminino
2.
Elife ; 122024 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-38270169

RESUMO

The α-arrestins form a large family of evolutionally conserved modulators that control diverse signaling pathways, including both G-protein-coupled receptor (GPCR)-mediated and non-GPCR-mediated pathways, across eukaryotes. However, unlike ß-arrestins, only a few α-arrestin targets and functions have been characterized. Here, using affinity purification and mass spectrometry, we constructed interactomes for 6 human and 12 Drosophila α-arrestins. The resulting high-confidence interactomes comprised 307 and 467 prey proteins in human and Drosophila, respectively. A comparative analysis of these interactomes predicted not only conserved binding partners, such as motor proteins, proteases, ubiquitin ligases, RNA splicing factors, and GTPase-activating proteins, but also those specific to mammals, such as histone modifiers and the subunits of V-type ATPase. Given the manifestation of the interaction between the human α-arrestin, TXNIP, and the histone-modifying enzymes, including HDAC2, we undertook a global analysis of transcription signals and chromatin structures that were affected by TXNIP knockdown. We found that TXNIP activated targets by blocking HDAC2 recruitment to targets, a result that was validated by chromatin immunoprecipitation assays. Additionally, the interactome for an uncharacterized human α-arrestin ARRDC5 uncovered multiple components in the V-type ATPase, which plays a key role in bone resorption by osteoclasts. Our study presents conserved and species-specific protein-protein interaction maps for α-arrestins, which provide a valuable resource for interrogating their cellular functions for both basic and clinical research.


Assuntos
Arrestina , ATPases Vacuolares Próton-Translocadoras , Animais , Humanos , Histonas , Drosophila , Arrestinas , Mamíferos
3.
Opt Lett ; 48(7): 1642-1645, 2023 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-37221730

RESUMO

We introduce a method of geometric screen modification to remove ghost reflections commonly observed in deflectometry optical testing. The proposed method modifies the optical layout and illumination source area to bypass the generation of reflected rays from the undesired surface. The layout flexibility of deflectometry allows us to design specific system layouts that avoid the generation of interrupting secondary rays. The proposed method is supported by optical raytrace simulations, and experimental results are demonstrated with convex and concave lens case studies. Finally, the limitations of the digital masking method are discussed.

4.
Biomedicines ; 11(2)2023 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-36830950

RESUMO

Cancer is the second leading cause of death worldwide, accounting for approximately 10 million deaths in 2020 [...].

5.
J Synchrotron Radiat ; 30(Pt 1): 65-75, 2023 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-36601927

RESUMO

Grazing-incidence reflective optics are commonly used in synchrotron radiation and free-electron laser facilities to transport and focus the emitted X-ray beams. To preserve the imaging capability at the diffraction limit, the fabrication of these optics requires precise control of both the residual height and slope errors. However, all the surface figuring methods are height based, lacking the explicit control of surface slopes. Although our preliminary work demonstrated a one-dimensional (1D) slope-based figuring model, its 2D extension is not straightforward. In this study, a novel 2D slope-based figuring method is proposed, which employs an alternating objective optimization on the slopes in the x- and y-directions directly. An analytical simulation revealed that the slope-based method achieved smaller residual slope errors than the height-based method, while the height-based method achieved smaller residual height errors than the slope-based method. Therefore, a hybrid height and slope figuring method was proposed to further enable explicit control of both the height and slopes according to the final mirror specifications. An experiment to finish an elliptical-cylindrical mirror using the hybrid method with ion beam figuring was then performed. Both the residual height and slope errors converged below the specified threshold values, which verified the feasibility and effectiveness of the proposed ideas.

6.
Opt Express ; 30(10): 16442-16458, 2022 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-36221487

RESUMO

Computer Controlled Optical Surfacing (CCOS) is widely applied for fabricating large aspheric optical surfaces. For large optics fabrication, various sizes of polishing tools are used sequentially. This raises the importance of efficient and globally optimized dwell time map of each tool. In this study, we propose a GEnetic Algorithm-powered Non-Sequential (GEANS) optimization technique to improve the feasibility of the conventional non-sequential optimization technique. GEANS consists of two interdependent parts: i) compose an influence matrix by imposing constraints on adjacent dwell points and ii) induce the desired dwell time map through the genetic algorithm. CCOS simulation results show that GEANS generates a preferable dwell time map that provides high figuring efficiency and structural similarity with the shape of target removal map, while improving computational efficiency more than 1000 times over the conventional non-sequential optimization method. The practicability of GEANS is demonstrated through error analyses. Random tool positioning error and tool influence function errors are imposed on dwell time maps. Compared to the conventional non-sequential optimization method, the power spectral density values of residual surface error from GEANS remain stable. GEANS also shows superior applicability when the maximum acceleration of a tool is applied.

7.
Opt Express ; 30(10): 16957-16972, 2022 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-36221529

RESUMO

With the rapid development of precision technologies, the demand of high-precision optical surfaces has drastically increased. These optical surfaces are mainly fabricated with computer controlled optical surfacing (CCOS). In a CCOS process, a target surface removal profile is achieved by scheduling the dwell time for a set of machine tools. The optimized dwell time should be positive and smooth to ensure convergence to the target while considering CNC dynamics. The total run time of each machine tool is also expected to be balanced to improve the overall processing efficiency. In the past few decades, dwell time optimization for a single machine tool has been extensively developed. While the methods are applicable to multi-tool scenarios, they fail to consider the overall contributions of multiple tools simultaneously. In this paper, we conduct a systematic study on the strategies for multi-tool dwell time optimization and propose an innovative method for simultaneously scheduling dwell time for multiple tools for the first time. First, the influential factors to the positiveness and smoothness of dwell time solutions for a single machine tool are analyzed. The compensation strategies that minimize the residual while considering the CNC dynamics limit are then proposed. Afterwards, these strategies are extended to the proposed multi-tool optimization that further balances the run time of machine tools. Finally, the superiority of each strategy is carefully studied via simulation and experiment. The experiment is performed by bonnet polishing a 60 mm × 60 mm mirror with three tools of different diameters (i.e., 12 mm, 8 mm, and 5 mm). The figure error of the mirror is reduced from 45.42 nm to 11.18 nm root mean square in 13.28 min. Moreover, the measured polishing result well coincides with the estimation, which proves the effectiveness of the proposed method.

8.
Opt Express ; 30(19): 33479-33489, 2022 Sep 12.
Artigo em Inglês | MEDLINE | ID: mdl-36242383

RESUMO

OASIS (Orbiting Astronomical Satellite for Investigating Stellar Systems) is a space-based observatory with a 14 m diameter inflatable primary antenna that will perform high spectral resolution observations at terahertz frequencies. The large inflatable aperture, non-traditional surface configuration, and the double layered membrane structure afford unique challenges to the modeling and testing of the primary antenna. A 1-meter prototype of the primary antenna (A1) was built to validate our technical approach. A laser radar coordinate measuring system was adopted to measure the shape of A1. In addition, deflectometry was performed to monitor the stability of A1 during the radar measurement. Test cases pertaining to specific operational conditions expected for the 14 m OASIS primary were explored. The measured data were then compared to the Fichter model and Finite-element Analyzer for Inflatable Membranes (FAIM).

9.
Opt Express ; 30(16): 29295-29309, 2022 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-36299107

RESUMO

Deterministic optics fabrication using sub-aperture tools has been vital for manufacturing precision optical surfaces. The fabrication process requires the tool influence function and the tool path to calculate the dwell time that guides the tool to bring surface quality within tight design tolerances. Widely used spiral and raster paths may leave excess waviness from the tool path, and the unavoidable constant removal layer is added to obtain positive dwell time. This waviness can be removed by either using smaller tools sequentially or randomizing the tool path. However, the existing tool-path solutions can hardly adapt to different surface aperture shapes and localized surface errors. Process efficiency and accuracy are also not well considered in tool-path planning. We propose an innovative zonal Random Adaptive Path (RAP) to solve these problems in this study. Firstly, RAP can be flexibly adapted to different surface aperture shapes by introducing part boundary. Secondly, an average threshold strategy is used in the RAP planning to improve efficiency, enabling the surface errors to be selectively corrected. Finally, the threshold is performed in several passes within one processing cycle, each with its RAP, until the desired residual is achieved. The performance of the proposed RAP is studied by comparing it with the conventional tool paths. The results demonstrated that RAP takes the least processing time and achieves the best surface quality, which verifies the effectiveness of RAP in deterministic optics fabrication.

10.
Micromachines (Basel) ; 13(9)2022 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-36144069

RESUMO

In a lidar system, replacing moving components with solid-state devices is highly anticipated to make a reliable and compact lidar system, provided that a substantially large beam area with a large angular extent as well as high angular resolution is assured for the lidar transmitter and receiver. A new quasi-solid-state lidar optical architecture employs a transmitter with a two-dimensional MEMS mirror for fine beam steering at a fraction of the degree of the angular resolution and is combined with a digital micromirror device for wide FOV scanning over 37 degree while sustaining a large aperture area of 140 mm squared. In the receiver, a second digital micromirror device is synchronized to the transmitter DMD, which enables a large FOV receiver. An angular resolution of 0.57°(H) by 0.23° (V) was achieved with 0.588 fps for scanning 1344 points within the field of view.

11.
Opt Lett ; 47(15): 3636-3639, 2022 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-35913280

RESUMO

We introduce an on-axis deflectometry test configuration for axicon metrology. Axicons are challenging to measure due to their characteristically steep, convex geometry. However, if an axicon is coaxially aligned with a camera and a surrounding cylindrical illumination source, high-resolution surface measurements can be obtained via the principle of deflectometry. Emitted from the temporally modulated source, light deflects at the conical surface and into the entrance pupil of a camera, illuminating the full axicon aperture except the ø 0.5-mm rounded tip. Deflectometry measurements of a 100° and 140° axicon show holistic cone angle agreement within 0.035° against touch probe data and up to 7.93 root µm mean square difference from a best-fit cone. We discuss the non-planar illumination architecture, sensitivity, and experimental results of arbitrary apex angle axicons.

12.
Opt Express ; 29(23): 38737-38757, 2021 Nov 08.
Artigo em Inglês | MEDLINE | ID: mdl-34808920

RESUMO

Computer-Controlled Optical Surfacing (CCOS) has been greatly developed and widely used for precision optical fabrication in the past three decades. It relies on robust dwell time solutions to determine how long the polishing tools must dwell at certain points over the surfaces to achieve the expected forms. However, as dwell time calculations are modeled as ill-posed deconvolution, it is always non-trivial to reach a reliable solution that 1) is non-negative, since CCOS systems are not capable of adding materials, 2) minimizes the residual in the clear aperture 3) minimizes the total dwell time to guarantee the stability and efficiency of CCOS processes, 4) can be flexibly adapted to different tool paths, 5) the parameter tuning of the algorithm is simple, and 6) the computational cost is reasonable. In this study, we propose a novel Universal Dwell time Optimization (UDO) model that universally satisfies these criteria. First, the matrix-based discretization of the convolutional polishing model is employed so that dwell time can be flexibly calculated for arbitrary dwell points. Second, UDO simplifies the inverse deconvolution as a forward scalar optimization for the first time, which drastically increases the solution stability and the computational efficiency. Finally, the dwell time solution is improved by a robust iterative refinement and a total dwell time reduction scheme. The superiority and general applicability of the proposed algorithm are verified on the simulations of different CCOS processes. A real application of UDO in improving a synchrotron X-ray mirror using Ion Beam Figuring (IBF) is then demonstrated. The simulation indicates that the estimated residual in the 92.3 mm × 15.7 mm CA can be reduced from 6.32 nm Root Mean Square (RMS) to 0.20 nm RMS in 3.37 min. After one IBF process, the measured residual in the CA converges to 0.19 nm RMS, which coincides with the simulation.

13.
Opt Lett ; 46(22): 5571-5574, 2021 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-34780408

RESUMO

One of deflectometry's cardinal strengths is its ability to measure highly dynamically sloped optics without needing physical null references. Accurate surface measurements using deflectometry, however, require precise calibration processes. In this Letter, we introduce an alignment technique using a computational fiducial to align a deflectometry system without additional hardware equipment (i.e., algorithmic innovation). Using the ray tracing program, we build relationships between the plane of the screen and detector and algorithmically generate a fiducial pattern for the deflectometry configuration. Since the fiducial pattern is based on ideal system geometry, misalignment of the unit under test with its target position causes a discrepancy between the actual image on the camera detector and the ideal fiducial image. We leverage G and C vector polynomials to quantify misalignment and estimate the alignment status through a reverse optimization method. Simulation and experimental results demonstrate that the proposed algorithm can align the 195mm×80mm of a rectangular aperture freeform optic within 10 µm of peak-to-valley accuracy. The computational fiducial-based alignment algorithm is simple to apply and can be an essential procedure for conventional methods of deflectometry system alignment.

14.
Biomed Opt Express ; 12(9): 5629-5643, 2021 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-34692205

RESUMO

We have developed a low-cost, chromatic confocal endomicroscope (CCE) that can image a cross-section of the tissue at cellular resolution. In CCE, a custom miniature objective lens was used to focus different wavelengths into different tissue depths. Therefore, each tissue depth was encoded with the wavelength. A custom miniature spectrometer was used to spectrally-disperse light reflected from the tissue and generate cross-sectional confocal images. The CCE prototype had a diameter of 9.5 mm and a length of 68 mm. Measured resolution was high, 2 µm and 4 µm for lateral and axial directions, respectively. Effective field size was 468 µm. Preliminary results showed that CCE can visualize cellular details from cross-sections of the tissue in vivo down to the tissue depth of 100 µm.

15.
Opt Express ; 29(10): 15114-15132, 2021 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-33985218

RESUMO

Precision optics have been widely required in many advanced technological applications. X-ray mirrors, as an example, serve as the key optical components at synchrotron radiation and free electron laser facilities. They are rectangular silicon or glass substrates where a rectangular Clear Aperture (CA) needs to be polished to sub-nanometer Root Mean Squared (RMS) to keep the imaging capability of the incoming X-ray wavefront at the diffraction limit. The convolutional polishing model requires a CA to be extended with extra data, from which the dwell time is calculated via deconvolution. However, since deconvolution is very sensitive to boundary errors and noise, the existing surface extension methods can hardly fulfill the sub-nanometer requirement. On one hand, the figure errors in a CA were improperly modeled during the extension, leading to continuity issues along the boundary. On the other hand, uncorrectable high-frequency errors and noise were also extended. In this study, we propose a novel Robust Iterative Surface Extension (RISE) method that resolves these problems with a data fitting strategy. RISE models the figure errors in a CA with orthogonal polynomials and ensures that only correctable errors are fit and extended. Combined with boundary conditions, an iterative refinement of dwell time is then proposed to compensate the errors brought by the extension and deconvolution, which drastically reduces the estimated figure error residuals in a CA while the increase of total dwell time is negligible. To our best knowledge, RISE is the first data fitting-based surface extension method and is the first to optimize dwell time based on iterative extension. An experimental verification of RISE is given by fabricating two elliptic cylinders (10 mm × 80 mm CAs) starting from a sphere with a radius of curvature around 173 m using ion beam figuring. The figure errors in the two CAs greatly improved from 204.96 nm RMS and 190.28 nm RMS to 0.62 nm RMS and 0.71 nm RMS, respectively, which proves that RISE is an effective method for sub-nanometer level X-ray mirror fabrication.

16.
Cancer Res ; 81(1): 77-90, 2021 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-32967925

RESUMO

Histone methyltransferase NSD3 is frequently dysregulated in human cancers, yet the epigenetic role of NSD3 during cancer development remains elusive. Here we report that NSD3-induced methylation of H3K36 is crucial for breast tumor initiation and metastasis. In patients with breast cancer, elevated expression of NSD3 was associated with recurrence, distant metastasis, and poor survival. In vivo, NSD3 promoted malignant transformation of mammary epithelial cells, a function comparable to that of HRAS. Furthermore, NSD3 expanded breast cancer-initiating cells and promoted epithelial-mesenchymal transition to trigger tumor invasion and metastasis. Mechanistically, the long isoform (full-length transcript) of NSD3, but not its shorter isoform lacking a catalytic domain, cooperated with EZH2 and RNA polymerase II to stimulate H3K36me2/3-dependent transactivation of genes associated with NOTCH receptor cleavage, leading to nuclear accumulation of NICD and NICD-mediated transcriptional repression of E-cadherin. Furthermore, mice harboring primary and metastatic breast tumors with overexpressed NSD3 showed sensitivity to NOTCH inhibition. Together, our findings uncover the critical epigenetic role of NSD3 in the modulation of NOTCH-dependent breast tumor progression, providing a rationale for targeting the NSD3-NOTCH signaling regulatory axis in aggressive breast cancer. SIGNIFICANCE: This study demonstrates the functional significance of histone methyltransferase NSD3 in epigenetic regulation of breast cancer stemness, EMT, and metastasis, suggesting NSD3 as an actionable therapeutic target in metastatic breast cancer.


Assuntos
Neoplasias da Mama/patologia , Metilação de DNA , Regulação Neoplásica da Expressão Gênica , Histona-Lisina N-Metiltransferase/metabolismo , Histonas/metabolismo , Neoplasias Pulmonares/secundário , Proteínas Nucleares/metabolismo , Receptor Notch1/metabolismo , Animais , Apoptose , Biomarcadores Tumorais/genética , Biomarcadores Tumorais/metabolismo , Neoplasias da Mama/genética , Neoplasias da Mama/metabolismo , Movimento Celular , Proliferação de Células , Epigênese Genética , Feminino , Histona-Lisina N-Metiltransferase/genética , Histonas/genética , Humanos , Neoplasias Pulmonares/genética , Neoplasias Pulmonares/metabolismo , Camundongos , Camundongos Endogâmicos NOD , Camundongos SCID , Proteínas Nucleares/genética , Prognóstico , Receptor Notch1/genética , Taxa de Sobrevida , Células Tumorais Cultivadas , Ensaios Antitumorais Modelo de Xenoenxerto
17.
Opt Lett ; 45(23): 6426-6429, 2020 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-33258828

RESUMO

Fabrication of large optics is a time-consuming process and requires a vast investment in manpower and financial resources. Increasing the material removal rate of polishing tools and minimizing dwell time are two common ways of reducing the processing time. Indeed, the polishing efficiency can be further improved if multiple tools are used at the same time. In this Letter, we propose a dual-tool deterministic polishing model, which multiplexes the dwell time and optimizes the run parameters of two polishing tools simultaneously. The run velocities of the two tools are coordinated by boundary conditions with a velocity adjustment algorithm, and the corresponding polishing paths are studied. We demonstrate this model with a simulation of polishing one segment of the Giant Magellan Telescope, where, with the proposed dual-tool multiplexing, the processing time of an ø8.4 m mirror has been reduced by 50.54% compared with that using two tools in a sequential schedule.

18.
Appl Opt ; 59(28): 8568-8574, 2020 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-33104535

RESUMO

We investigated interference fringes due to superposition of diverging light waves reflected from the two sides of a plane parallel plate. A non-localized fringe pattern of high contrast was obtained as a function of incident angle when we used a coherent diverging beam. We found that the fringe density increased to a certain angle and then decreased thereafter, against the common belief that the fringe density increases monotonically with the angle of incidence. Because the fringe density is maximum at this angle and does not change rapidly in the vicinity, we could employ Fourier analysis to estimate interferometric parameters, such as thickness, refractive index, and wavelength, that determine the characteristic stationary fringe density.

19.
Sci Rep ; 10(1): 8135, 2020 May 18.
Artigo em Inglês | MEDLINE | ID: mdl-32424222

RESUMO

With the rapid evolution of synchrotron X-ray sources, the demand for high-precision X-ray mirrors has greatly increased. Single nanometer profile error is required to keep imaging capability at the diffraction limit. Ion Beam Figuring (IBF), as a highly deterministic surfacing technique, has been used for ultra-precision finishing of mirrors. One crucial step that guides the IBF process is dwell time calculation. A valid dwell time solution should be non-negative and duplicate the shape of the desired removal map. Another important aspect is to minimize the total dwell time. In this study, we propose a Robust Iterative Fourier Transform-based dwell time Algorithm (RIFTA) that automatically fulfills these requirements. First, the thresholded inverse filtering in Fourier transform-based deconvolution is stabilized and automated by optimizing the threshold value using the Nelder-Mead simplex algorithm. Second, a novel two-level iterative scheme is proposed to guarantee the minimized total dwell time with its non-negativity at each dwell point. Third, a bicubic resampling is employed to flexibly adapt the calculated dwell time map to any IBF process intervals. The performance of RIFTA is first studied with simulation, followed by a comparison with the other state-of-the-art dwell time algorithms. We then demonstrate with an experiment that, using the dwell time calculated by the RIFTA, the total dwell time is shortened by a factor of two and the RMS in a 5 × 50 mm clear aperture was reduced from 3.4 nm to 1.1 nm after one IBF run, which proves the effectiveness and the efficiency of the proposed algorithm.

20.
Appl Opt ; 59(11): 3306-3314, 2020 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-32400440

RESUMO

With the rapid evolution of synchrotron x-ray sources, the demand for high-quality precision x-ray mirrors has greatly increased. Single nanometer shape accuracy is required to keep imaging capabilities at the diffraction limit. Ion beam figuring (IBF) has been used frequently for ultra-precision finishing of mirrors, but achieving the ultimate accuracy depends on three important points: careful alignment, accurate dwell time calculation and implementation, and accurate optical metrology. The Optical Metrology Group at National Synchrotron Light Source II has designed and built a position-velocity-time-modulated two-dimensional IBF system (PVT-IBF) with three novel characteristics: (1) a beam footprint on the mirror was used as a reference to align the coordinate systems between the metrology and the IBF hardware; (2) the robust iterative Fourier transform-based dwell time algorithm proposed by our group was applied to obtain an accurate dwell time map; and (3) the dwell time was then transformed to velocities and implemented with the PVT motion scheme. In this study, the technical aspects of the PVT-IBF systems are described in detail, followed by an experimental demonstration of the figuring results. In our first experiment, the 2D RMS in a $ 50\;{\rm mm} \times 5\;{\rm mm} $50mm×5mm clear aperture was reduced from 3.4 to 1.1 nm after one IBF run. In our second experiment, due to a 5 mm pinhole installed in front of the source, the 2D RMS in a $ 50\;{\rm mm} \times 5\;{\rm mm} $50mm×5mm clear aperture was reduced from 39.1 to 1.9 nm after three IBF runs, demonstrating that our PVT-IBF solution is an effective and deterministic figuring process.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...