Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
RSC Adv ; 14(12): 8331-8340, 2024 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-38469191

RESUMO

The ever-increasing risks posed by antibiotic-resistant bacteria have stimulated considerable interest in the development of novel antimicrobial strategies, including the use of nanomaterials that can be activated on demand and result in irreversible damage to pathogens. Microwave electric field-assisted bactericidal effects on representative Gram-negative and Gram-positive bacterial strains were achieved in the presence of hybrid polydopamine-silver nanoparticles (PDA-Ag NPs) under low-power microwave irradiation using a resonant cavity (1.3 W, 2.45 GHz). A 3-log reduction in the viability of bacterial populations was observed within 30 minutes which was attributed to the attachment of PDA-Ag NPs and associated membrane disruption in conjunction with the production of intra-bacterial reactive oxygen species (ROS). A synergistic effect between PDA and Ag has been demonstrated whereby PDA acts both as an Ag NP carrier and a microwave enhancer. These properties together with the remarkable adhesivity of PDA are opening a route to design of antibacterial adhesives and surface coatings for prevention of biofilm formation.

2.
Biochem Biophys Res Commun ; 661: 89-98, 2023 06 18.
Artigo em Inglês | MEDLINE | ID: mdl-37087803

RESUMO

The ubiquity of wireless electronic-device connectivity has seen microwaves emerge as one of the fastest growing forms of electromagnetic exposure. A growing evidence-base refutes the claim that wireless technologies pose no risk to human health at current safety levels designed to limit thermal (heating) effects. The potential impact of non-thermal effects of microwave exposure, especially in electrically-excitable tissues (e.g., heart), remains controversial. We exposed human embryonic stem-cell derived cardiomyocytes (CM), under baseline and beta-adrenergic receptor (ß-AR)-stimulated conditions, to microwaves at 2.4 GHz, a frequency used extensively in wireless communication (e.g., 4G, Bluetooth™ and WiFi). To control for any effect of sample heating, experiments were done in CM subjected to matched rates of direct heating or CM maintained at 37 °C. Detailed profiling of the temporal and amplitude features of Ca2+ signalling in CM under these experimental conditions was reconciled with the extent and spatial clustering of apoptosis. The data show that exposure of CM to 2.4 GHz EMF eliminated the normal Ca2+ signalling response to ß-AR stimulation and provoked spatially-clustered apoptosis. This is first evidence that non-thermal effects of 2.4 GHz microwaves might have profound effects on human CM function, responsiveness to activation, and survival.


Assuntos
Micro-Ondas , Receptores Adrenérgicos beta , Humanos , Miócitos Cardíacos , Transdução de Sinais , Campos Eletromagnéticos
3.
BMC Med Inform Decis Mak ; 23(1): 38, 2023 02 22.
Artigo em Inglês | MEDLINE | ID: mdl-36814262

RESUMO

BACKGROUND: Innovation in healthcare technologies can result in more convenient and effective treatment that is less costly, but a persistent challenge to widespread adoption in health and social care is end user acceptability. The purpose of this study was to capture UK public opinions and attitudes to novel healthcare technologies (NHTs), and to better understand the factors that contribute to acceptance and future use. METHODS: An online survey was distributed to the UK public between April and May 2020. Respondents received brief information about four novel healthcare technologies (NHTs) in development: a laser-based tool for early diagnosis of osteoarthritis, a virtual reality tool to support diabetes self-management, a non-invasive continuous glucose monitor using microwave signals, a mobile app for patient reported monitoring of rheumatoid arthritis. They were queried on their general familiarity and attitudes to technology, and their willingness to accept each NHT in their future care. Responses were analysed using summary statistics and content analysis. RESULTS: Knowledge about NHTs was diverse, with respondents being more aware about the health applications of mobile apps (66%), followed by laser-based technology (63.8%), microwave signalling (28%), and virtual reality (18.3%). Increasing age and the presence of a self-reported medical condition favoured acceptability for some NHTs, whereas self-reported understanding of how the NHT works resulted in elevated acceptance scores across all NHTs presented. Common contributors to hesitancy were safety and risks from use. Respondents wanted more information and evidence to help inform their decisions, ideally provided verbally by a general practitioner or health professional. Other concerns, such as privacy, were NHT-specific but equally important in decision-making. CONCLUSIONS: Early insight into the knowledge and preconceptions of the public about NHTs in development can assist their design and prospectively mitigate obstacles to acceptance and adoption.


Assuntos
Atenção à Saúde , Aplicativos Móveis , Humanos , Atitude , Inquéritos e Questionários , Reino Unido
4.
Sensors (Basel) ; 22(23)2022 Dec 06.
Artigo em Inglês | MEDLINE | ID: mdl-36502229

RESUMO

Cervical tissue hydration level is one of the most important parameters to monitor in the early diagnosis of preterm birth. Electrical-impedance-spectroscopy-based techniques are often used, but they suffer from limited accuracy. Open microwave coaxial probes have been widely used as a broadband dielectric characterization technique for human tissue samples due to their versatility, but with limited accuracy due to their nonresonant nature. In this work, a resonant microwave open coaxial probe with multiple harmonic resonances is proposed as a sensing platform for tissue-hydration-level monitoring. The mechanical design was analyzed and verified by finite-element full 3D electromagnetic simulation and experiments. Dominant sources of errors and the ways to mitigate them were discussed. In vitro experiments were carried out on human cervix samples to verify the precision and accuracy by comparing the results to a commercial skin-hydration sensor. The proposed sensor shows mean fractional frequency shift of (3.3 ± 0.3) × 10-4 per unit % over the entire data. This translates into an absolute frequency shift (ΔfN) of 252 ± 23 kHz/%, 455 ± 41 kHz/%, and 647 ± 57 kHz/% at second, fourth, and sixth harmonic resonance, respectively.


Assuntos
Nascimento Prematuro , Recém-Nascido , Feminino , Humanos , Micro-Ondas , Espectroscopia Dielétrica , Colo do Útero , Pele
5.
J Am Chem Soc ; 143(10): 3934-3943, 2021 03 17.
Artigo em Inglês | MEDLINE | ID: mdl-33660507

RESUMO

The nature of anionic alkali metals in solution is traditionally thought to be "gaslike" and unperturbed. In contrast to this noninteracting picture, we present experimental and computational data herein that support ion pairing in alkalide solutions. Concentration dependent ionic conductivity, dielectric spectroscopy, and neutron scattering results are consistent with the presence of superalkali-alkalide ion pairs in solution, whose stability and properties have been further investigated by DFT calculations. Our temperature dependent alkali metal NMR measurements reveal that the dynamics of the alkalide species is both reversible and thermally activated suggesting a complicated exchange process for the ion paired species. The results of this study go beyond a picture of alkalides being a "gaslike" anion in solution and highlight the significance of the interaction of the alkalide with its complex countercation (superalkali).

6.
J Magn Reson ; 310: 106644, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31812887

RESUMO

A unique dual mode X-band Continuous Wave (CW) EPR resonator designed for simultaneous EPR measurement and rapid microwave (MW) induced sample heating is described. Chemical reactions subjected to a flow of energy and matter can be perturbed away from the thermodynamic equilibrium by imposing a rapid shock or physical change to the system. Depending on the magnitude of the perturbation, these changes can dictate the subsequent evolution of the entire system, allowing for instance to populate non-equilibrium reactive intermediate states. Temperature jump (T-jump) experiments are a common method to achieve such perturbations. Most T-jump experiments are based on Joule Heating methods or IR lasers. Here we demonstrate the principle of rapid sample heating based on microwaves. The benefits of MW heating include (i) rapid and efficient heating (i.e. using a tuned resonant cavity, >99% efficient power transfer to the sample can be achieved), and (ii) volumetric heating (i.e. the entire sample volume rises in temperature at once, since heat is generated in the sample instead of being transferred to it). Accordingly, the key concept of the design is the use of a cavity resonator allowing EPR detection (at 9.5 GHz) and simultaneous sample heating (at 6.1 GHz). Temperature increments of 50 °C within a few seconds are possible. This is evidenced and illustrated here by probing the temperature-induced variation of the rotational dynamics of 16-doxyl stearic acid methyl ester (16-DSE) spin probe grafted on the surface of sodium dodecyl sulphate (SDS) micelles in water, as well as copper (II) acetylacetonate in chloroform. Rapid changes in the rotational dynamics of the paramagnetic centres provide direct evidence for the in situ and simultaneous EPR measurement-heating capabilities of the resonator. Improvements afforded by the use of pulsed MW sources will enable faster heating time scales to be achieved. In the longer term, this current study demonstrates the simple and direct possibilities for using MW heating as a means of performing T-jump experiments.

7.
J Biomed Opt ; 24(5): 1-11, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30816030

RESUMO

Biological systems with intrinsic luminescent properties serve as powerful and noninvasive bioreporters for real-time and label-free monitoring of cell physiology. This study employs the bioluminescent marine bacterium Vibrio fischeri to investigate the effects of separated microwave electric (E) and magnetic (H) fields. Using a cylindrical TM010 mode aluminum resonant cavity, designed to spatially separate E and H fields of a pulsed microwave (2.45 GHz) input, we sampled at 100-ms intervals the 490-nm emission of bioluminescence from suspensions of the V. fischeri. E-field exposure (at 4.24 and 13.4 kV/m) results in rapid and sensitive responses to 100-ms pulses. H-field excitation elicits no measurable responses, even at 100-fold higher power input levels (equivalent to 183 A/m). The observed effects on bacterial light output partially correlate with measured E-field-induced temperature increases. In conclusion, the endogenous bioluminescence of V. fischeri provides a sensitive and noninvasive method to assess the biological effects of microwave fields.


Assuntos
Aliivibrio fischeri/metabolismo , Aliivibrio fischeri/efeitos da radiação , Eletricidade , Luminescência , Micro-Ondas , Alumínio , Medições Luminescentes , Campos Magnéticos , Fótons , Software , Temperatura , Fatores de Tempo
8.
IEEE Trans Microw Theory Tech ; 63(10 Pt 1): 3016-3025, 2015 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-26568639

RESUMO

A design of a microwave noninvasive continuous blood glucose monitoring sensor and its interference test results are presented. The novelty of the proposed sensor is that it comprises two spatially separated split-ring resonators, where one interacts with the change in glucose level of a sample under test while the other ring is used as a reference. The reference ring has a slightly different resonant frequency and is desensitized to the sample owing to its location, thus allowing changes in temperature to be calibrated out. From an oral glucose tolerance test with two additional commercially available sensors (blood strip and continuous glucose monitor) in parallel, we obtained encouraging performance for our sensor comparable with those of the commercial sensors. The effects of endogenous interferents common to all subjects, i.e., common sugars, vitamins (ascorbic acid), and metabolites (uric acid) have also been investigated by using a large Franz cell assembly. From the interference test, it is shown that the change in sensor response is dominated by changes in glucose level for concentrations relevant to blood, and the effects of interferents are negligible in comparison.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA