1.
Implement Sci Commun ; 4(1): 80, 2023 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-37461120

RESUMO

BACKGROUND: Apnoea of prematurity (AOP) is a common condition among preterm infants. Methylxanthines, such as caffeine and aminophylline/theophylline, can help prevent and treat AOP. Due to its physiological benefits and fewer side effects, caffeine citrate is recommended for the prevention and treatment of AOP. However, caffeine citrate is not available in most resource-constrained settings (RCS) due to its high cost. Challenges in RCS using caffeine citrate to prevent AOP include identifying eligible preterm infants where gestational age is not always known and the capability for continuous monitoring of vital signs to readily identify apnoea. We aim to develop an evidence-based care bundle that includes caffeine citrate to prevent and manage AOP in tertiary healthcare facilities in Kenya. METHODS: This protocol details a prospective mixed-methods clinical feasibility study on using caffeine citrate to manage apnoea of prematurity in a single facility tertiary-care newborn unit (NBU) in Nairobi, Kenya. This study will include a 4-month formative research phase followed by the development of an AOP clinical-care-bundle prototype over 2 months. In the subsequent 4 months, implementation and improvement of the clinical-care-bundle prototype will be undertaken. The baseline data will provide contextualised insights on care practices within the NBU that will inform the development of a context-sensitive AOP clinical-care-bundle prototype. The clinical care bundle will be tested and refined further during an implementation phase of the quality improvement initiative using a PDSA framework underpinned by quantitative and qualitative clinical audits and stakeholders' engagement. The quantitative component will include all neonates born at gestation age < 34 weeks and any neonate prescribed aminophylline or caffeine citrate admitted to the NBU during the study period. DISCUSSION: There is a need to develop evidence-based and context-sensitive clinical practice guidelines to standardise and improve the management of AOP in RCS. Concerns requiring resolution in implementing such guidelines include diagnosis of apnoea, optimal timing, dosing and administration of caffeine citrate, standardisation of monitoring devices and alarm limits, and discharge protocols. We aim to provide a feasible standardised clinical care bundle for managing AOP in low and middle-income settings.

2.
Sci Rep ; 12(1): 11722, 2022 07 09.
Artigo em Inglês | MEDLINE | ID: mdl-35810244

RESUMO

Clinically feasible multiparameter continuous physiological monitoring technologies are needed for use in resource-constrained African healthcare facilities to allow for early detection of critical events and timely intervention for major morbidities in high-risk neonates. We conducted a prospective clinical feasibility study of a novel multiparameter continuous physiological monitoring technology in neonates at Pumwani Maternity Hospital in Nairobi, Kenya. To assess feasibility, we compared the performance of Sibel's Advanced Neonatal Epidermal (ANNE) technology to reference technologies, including Masimo's Rad-97 pulse CO-oximeter with capnography technology for heart rate (HR), respiratory rate (RR), and oxygen saturation (SpO2) measurements and Spengler's Tempo Easy non-contact infrared thermometer for temperature measurements. We evaluated key performance criteria such as up-time, clinical event detection performance, and the agreement of measurements compared to those from the reference technologies in an uncontrolled, real-world setting. Between September 15 and December 15, 2020, we collected and analyzed 503 h of ANNE data from 109 enrolled neonates. ANNE's up-time was 42 (11%) h more for HR, 77 (25%) h more for RR, and 6 (2%) h less for SpO2 compared to the Rad-97. However, ANNE's ratio of up-time to total attached time was less than Rad-97's for HR (0.79 vs 0.86), RR (0.68 vs. 0.79), and SpO2 (0.69 vs 0.86). ANNE demonstrated adequate performance in identifying high and low HR and RR and high temperature events; however, showed relatively poor performance for low SpO2 events. The normalized spread of limits of agreement were 8.4% for HR and 52.2% for RR and the normalized root-mean-square deviation was 4.4% for SpO2. Temperature agreement showed a spread of limits of agreement of 2.8 °C. The a priori-identified optimal limits were met for HR and temperature but not for RR or SpO2. ANNE was clinically feasible for HR and temperature but not RR and SpO2 as demonstrated by the technology's up-time, clinical event detection performance, and the agreement of measurements compared to those from the reference technologies.


Assuntos
Maternidades , Oximetria , Estudos de Viabilidade , Feminino , Humanos , Recém-Nascido , Quênia , Monitorização Fisiológica , Gravidez , Estudos Prospectivos , Tecnologia
3.
PLoS One ; 17(6): e0267026, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35771801

RESUMO

BACKGROUND: Neonatal multiparameter continuous physiological monitoring (MCPM) technologies assist with early detection of preventable and treatable causes of neonatal mortality. Evaluating accuracy of novel MCPM technologies is critical for their appropriate use and adoption. METHODS: We prospectively compared the accuracy of Sibel's Advanced Neonatal Epidermal (ANNE) technology with Masimo's Rad-97 pulse CO-oximeter with capnography and Spengler's Tempo Easy reference technologies during four evaluation rounds. We compared accuracy of heart rate (HR), respiratory rate (RR), oxygen saturation (SpO2), and skin temperature using Bland-Altman plots and root-mean-square deviation analyses (RMSD). Sibel's ANNE algorithms were optimized between each round. We created Clarke error grids with zones of 20% to aid with clinical interpretation of HR and RR results. RESULTS: Between November 2019 and August 2020 we collected 320 hours of data from 84 neonates. In the final round, Sibel's ANNE technology demonstrated a normalized bias of 0% for HR and 3.1% for RR, and a non-normalized bias of -0.3% for SpO2 and 0.2°C for temperature. The normalized spread between 95% upper and lower limits-of-agreement (LOA) was 4.7% for HR and 29.3% for RR. RMSD for SpO2 was 1.9% and 1.5°C for temperature. Agreement between Sibel's ANNE technology and the reference technologies met the a priori-defined thresholds for 95% spread of LOA and RMSD. Clarke error grids showed that all HR and RR observations were within a 20% difference. CONCLUSION: Our findings suggest acceptable agreement between Sibel's ANNE and reference technologies. Clinical effectiveness, feasibility, usability, acceptability, and cost-effectiveness investigations are necessary for large-scale implementation.


Assuntos
Oximetria , Taxa Respiratória , Humanos , Recém-Nascido , Quênia , Monitorização Fisiológica/métodos , Oximetria/métodos , Oxigênio , Taxa Respiratória/fisiologia
4.
J Clin Monit Comput ; 36(6): 1869-1879, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35332406

RESUMO

Accurate measurement of respiratory rate (RR) in neonates is challenging due to high neonatal RR variability (RRV). There is growing evidence that RRV measurement could inform and guide neonatal care. We sought to quantify neonatal RRV during a clinical study in which we compared multiparameter continuous physiological monitoring (MCPM) devices. Measurements of capnography-recorded exhaled carbon dioxide across 60-s epochs were collected from neonates admitted to the neonatal unit at Aga Khan University-Nairobi hospital. Breaths were manually counted from capnograms and using an automated signal detection algorithm which also calculated mean and median RR for each epoch. Outcome measures were between- and within-neonate RRV, between- and within-epoch RRV, and 95% limits of agreement, bias, and root-mean-square deviation. Twenty-seven neonates were included, with 130 epochs analysed. Mean manual breath count (MBC) was 48 breaths per minute. Median RRV ranged from 11.5% (interquartile range (IQR) 6.8-18.9%) to 28.1% (IQR 23.5-36.7%). Bias and limits of agreement for MBC vs algorithm-derived breath count, MBC vs algorithm-derived median breath rate, MBC vs algorithm-derived mean breath rate were - 0.5 (- 2.7, 1.66), - 3.16 (- 12.12, 5.8), and - 3.99 (- 11.3, 3.32), respectively. The marked RRV highlights the challenge of performing accurate RR measurements in neonates. More research is required to optimize the use of RRV to improve care. When evaluating MCPM devices, accuracy thresholds should be less stringent in newborns due to increased RRV. Lastly, median RR, which discounts the impact of extreme outliers, may be more reflective of the underlying physiological control of breathing.


Assuntos
Capnografia , Taxa Respiratória , Recém-Nascido , Humanos , Taxa Respiratória/fisiologia , Quênia , Monitorização Fisiológica , Respiração
5.
Sci Rep ; 12(1): 3097, 2022 02 23.
Artigo em Inglês | MEDLINE | ID: mdl-35197529

RESUMO

Multiparameter continuous physiological monitoring (MCPM) technologies are critical in the clinical management of high-risk neonates; yet, these technologies are frequently unavailable in many African healthcare facilities. We conducted a prospective clinical feasibility study of EarlySense's novel under-mattress MCPM technology in neonates at Pumwani Maternity Hospital in Nairobi, Kenya. To assess feasibility, we compared the performance of EarlySense's technology to Masimo's Rad-97 pulse CO-oximeter with capnography technology for heart rate (HR) and respiratory rate (RR) measurements using up-time, clinical event detection performance, and accuracy. Between September 15 and December 15, 2020, we collected and analyzed 470 hours of EarlySense data from 109 enrolled neonates. EarlySense's technology's up-time per neonate was 2.9 (range 0.8, 5.3) hours for HR and 2.1 (range 0.9, 4.0) hours for RR. The difference compared to the reference was a median of 0.6 (range 0.1, 3.1) hours for HR and 0.8 (range 0.1, 2.9) hours for RR. EarlySense's technology identified high HR and RR events with high sensitivity (HR 81%; RR 83%) and specificity (HR 99%; RR 83%), but was less sensitive for low HR and RR (HR 0%; RR 14%) although maintained specificity (HR 100%; RR 95%). There was a greater number of false negative and false positive RR events than false negative and false positive HR events. The normalized spread of limits of agreement was 9.6% for HR and 28.6% for RR, which met the a priori-identified limit of 30%. EarlySense's MCPM technology was clinically feasible as demonstrated by high percentage of up-time, strong clinical event detection performance, and agreement of HR and RR measurements compared to the reference technology. Studies in critically ill neonates, assessing barriers and facilitators to adoption, and costing analyses will be key to the technology's development and potential uptake and scale-up.


Assuntos
Maternidades , Hospitais Públicos , Doenças do Recém-Nascido/diagnóstico , Doenças do Recém-Nascido/prevenção & controle , Monitorização Fisiológica/métodos , Reações Falso-Negativas , Reações Falso-Positivas , Estudos de Viabilidade , Feminino , Frequência Cardíaca , Humanos , Recém-Nascido , Quênia , Limite de Detecção , Gravidez , Estudos Prospectivos , Taxa Respiratória , Risco
6.
BMJ Open ; 12(1): e053486, 2022 01 11.
Artigo em Inglês | MEDLINE | ID: mdl-35017248

RESUMO

OBJECTIVE: To assess the feasibility, usability and acceptability of two non-invasive, multiparameter, continuous physiological monitoring (MCPM) technologies for use in neonates within a resource-constrained healthcare setting in sub-Saharan Africa. DESIGN: A qualitative study using in-depth interviews and direct observations to describe healthcare professional and caregiver perspectives and experiences with investigational MCPM technologies from EarlySense and Sibel compared with selected reference technologies. SETTING: Pumwani Maternity Hospital is a public, high-volume, tertiary hospital in Nairobi, Kenya. PARTICIPANTS: In-depth interviews were conducted with five healthcare administrators, 12 healthcare providers and 10 caregivers. Direct observations were made of healthcare providers using the technologies on 12 neonates overall. RESULTS: Design factors like non-invasiveness, portability, ease-of-use and ability to measure multiple vital signs concurrently emerged as key themes supporting the usability and acceptability of the investigational technologies. However, respondents also reported feasibility challenges to implementation, including overcrowding in the neonatal unit, lack of reliable access to electricity and computers, and concerns about cost and maintenance needs. To improve acceptability, respondents highlighted the need for adequate staffing to appropriately engage caregivers and dispel misconceptions about the technologies. CONCLUSION: Study participants were positive about the usefulness of the investigational technologies to strengthen clinical care quality and identification of at-risk neonates for better access to timely interventions. These technologies have the potential to improve equity of access to appropriate healthcare services and neonatal outcomes in sub-Saharan African healthcare facilities. However, health system strengthening is also critical to support sustainable uptake of technologies into routine care. TRIAL REGISTRATION NUMBER: NCT03920761.


Assuntos
Centros de Atenção Terciária , Estudos de Viabilidade , Feminino , Humanos , Recém-Nascido , Quênia , Monitorização Fisiológica , Gravidez , Pesquisa Qualitativa
7.
Arch Dis Child ; 107(6): 558-564, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-34740876

RESUMO

BACKGROUND: Globally, 2.5 million neonates died in 2018, accounting for 46% of under-5 deaths. Multiparameter continuous physiological monitoring (MCPM) of neonates allows for early detection and treatment of life-threatening health problems. However, neonatal monitoring technology is largely unavailable in low-resource settings. METHODS: In four evaluation rounds, we prospectively compared the accuracy of the EarlySense under-mattress device to the Masimo Rad-97 pulse CO-oximeter with capnography reference device for heart rate (HR) and respiratory rate (RR) measurements in neonates in Kenya. EarlySense algorithm optimisations were made between evaluation rounds. In each evaluation round, we compared 200 randomly selected epochs of data using Bland-Altman plots and generated Clarke error grids with zones of 20% to aid in clinical interpretation. RESULTS: Between 9 July 2019 and 8 January 2020, we collected 280 hours of MCPM data from 76 enrolled neonates. At the final evaluation round, the EarlySense MCPM device demonstrated a bias of -0.8 beats/minute for HR and 1.6 breaths/minute for RR, and normalised spread between the 95% upper and lower limits of agreement of 6.2% for HR and 27.3% for RR. Agreement between the two MCPM devices met the a priori-defined threshold of 30%. The Clarke error grids showed that all observations for HR and 197/200 for RR were within a 20% difference. CONCLUSION: Our research indicates that there is acceptable agreement between the EarlySense and Masimo MCPM devices in the context of large within-subject variability; however, further studies establishing cost-effectiveness and clinical effectiveness are needed before large-scale implementation of the EarlySense MCPM device in neonates. TRIAL REGISTRATION NUMBER: NCT03920761.


Assuntos
Oximetria , Taxa Respiratória , Frequência Cardíaca , Humanos , Recém-Nascido , Quênia , Monitorização Fisiológica , Taxa Respiratória/fisiologia
8.
J Med Internet Res ; 23(10): e29755, 2021 10 28.
Artigo em Inglês | MEDLINE | ID: mdl-34709194

RESUMO

BACKGROUND: Continuous physiological monitoring technologies are important for strengthening hospital care for neonates, particularly in resource-constrained settings, and understanding user perspectives is critical for informing medical technology design, development, and optimization. OBJECTIVE: This study aims to assess the feasibility, usability, and acceptability of 2 noninvasive, multiparameter, continuous physiological monitoring technologies for use in neonates in an African health care setting. METHODS: We assessed 2 investigational technologies from EarlySense and Sibel, compared with the reference Masimo Rad-97 technology through in-depth interviews and direct observations. A purposive sample of health care administrators, health care providers, and caregivers at Aga Khan University Hospital, a tertiary, private hospital in Nairobi, Kenya, were included. Data were analyzed using a thematic approach in NVivo 12 software. RESULTS: Between July and August 2020, we interviewed 12 health care providers, 5 health care administrators, and 10 caregivers and observed the monitoring of 12 neonates. Staffing and maintenance of training in neonatal units are important feasibility considerations, and simple training requirements support the feasibility of the investigational technologies. Key usability characteristics included ease of use, wireless features, and reduced number of attachments connecting the neonate to the monitoring technology, which health care providers considered to increase the efficiency of care. The main factors supporting acceptability included caregiver-highlighted perceptions of neonate comfort and health care respondent technology familiarity. Concerns about the side effects of wireless connections, electromagnetic fields, and mistrust of unfamiliar technologies have emerged as possible acceptability barriers to investigational technologies. CONCLUSIONS: Overall, respondents considered the investigational technologies feasible, usable, and acceptable for the care of neonates at this health care facility. Our findings highlight the potential of different multiparameter continuous physiological monitoring technologies for use in different neonatal care settings. Simple and user-friendly technologies may help to bridge gaps in current care where there are many neonates; however, challenges in maintaining training and ensuring feasibility within resource-constrained health care settings warrant further research. INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID): RR2-10.1136/bmjopen-2019-035184.


Assuntos
Cuidadores , Pessoal de Saúde , Estudos de Viabilidade , Hospitais Privados , Humanos , Recém-Nascido , Quênia , Monitorização Fisiológica , Tecnologia , Centros de Atenção Terciária