Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Front Surg ; 5: 49, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30105227

RESUMO

Objective: One of the late-onset complications of cardiac implanted electronic devices (CIEDs) is central venous obstruction (CVO). The aim of this study was to investigate the feasibility, efficacy, and safety of endovascular treatment of CIED-related CVOs. Methods:Eighteen patients who underwent endovascular management of their device-related CVO were reviewed. Patients were classified into three groups: Group I patients were asymptomatic and needed lead replacement; Group II patients presented with symptomatic CVO without lead dysfunction, and Group III patients were referred with both symptomatic CVO and lead dysfunction. A treatment strategy involved recanalization and balloon angioplasty for Group I and angioplasty/stents for Groups II and III. Technical success, clinical success, complications, and long-term follow-up were assessed. Results: Thirteen patients were in Group I, four in Group II, and one in Group III. Technical and clinical success was achieved in 17 patients (94%). No major complications were reported. Restenosis was observed in two patients at 40 and 42 weeks of follow-up, and these patients were successfully treated with angioplasty. Conclusion: Endovascular management of CVO due to CIED is a safe and efficient technique. Plain balloon angioplasty is sufficient for lead replacement purposes, while stenting is needed for symptomatic CVO to achieve good long-term patency.

2.
Eur Radiol ; 28(11): 4792-4799, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29789906

RESUMO

OBJECTIVES: Recanalization of peripheral chronic total occlusions (CTO) is technically challenging especially in cases of in-stent and/or pre-stent and heavily calcified lesions. A high-frequency vibrational device (HFVD) was first used as a secondary-intention device in CTO recanalizations when they were refractory to a guidewire. The aim of this study was to assess the safety and efficacy of the HFVD as a first-line treatment for challenging CTOs and thus to define the percutaneous intentional intraluminal-assisted recanalization (PILAR) technique. METHODS: Fifty-two patients were treated with the HFVD. Only challenging CTOs were included: 7 pre-stent, 7 in-stent, and 38 highly calcified CTOs. Technical success was defined as the ability to cross the CTO using the HFVD. Secondary outcome was defined as successful intraluminal crossing. Safety endpoints were procedure-related thromboembolism or perforation. Patients were followed up at 3 months and 1 year. RESULTS: The technical success rate for recanalization was 90%, of which 83% were intraluminal. The mean recanalized length was 91 ± 44 mm. One thromboembolic complication occurred, which was subsequently treated with thromboaspiration. Three-month and 1-year primary patency rates were 92% and 79%, respectively. CONCLUSIONS: HFVD-based PILAR is a safe and effective technique for in-stent or pre-stent CTO recanalization of long and calcified lesions. KEY POINTS: • Intraluminal recanalization is the preferred procedure in heavily calcified or pre-/in-stent CTO. • First-line use of assisted intraluminal recanalization for CTO defines the PILAR technique. • HFVD-based PILAR is safe and provides a high success rate for challenging CTO recanalization.


Assuntos
Cateterismo/métodos , Claudicação Intermitente/terapia , Perna (Membro)/irrigação sanguínea , Vibração/uso terapêutico , Adulto , Idoso , Idoso de 80 Anos ou mais , Angiografia , Doença Crônica , Feminino , Humanos , Claudicação Intermitente/diagnóstico , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
4.
Radiat Oncol ; 7: 134, 2012 Aug 08.
Artigo em Inglês | MEDLINE | ID: mdl-22873771

RESUMO

BACKGROUND: To assess the influence of sentinel lymph nodes (SNs) SPECT/CT and 18 F-choline (18 F-FCH) PET/CT in radiotherapy (RT) treatment planning for prostate cancer patients with a high-risk for lymph node (LN) involvement. METHODS: Twenty high-risk prostate cancer patients underwent a pelvic SPECT acquisition following a transrectal ultrasound guided injection of 99mTc-Nanocoll into the prostate. In all patients but one an 18 F-FCH PET/CT for RT treatment planning was performed. SPECT studies were coregistered with the respective abdominal CTs. Pelvic SNs localized on SPECT/CT and LN metastases detected by 18 F-FCH PET/CT were compared to standard pelvic clinical target volumes (CTV). RESULTS: A total of 104 pelvic SNs were identified on SPECT/CT (mean 5.2 SNs/patient; range 1-10). Twenty-seven SNs were located outside the standard pelvic CTV, 17 in the proximal common iliac and retroperitoneal regions above S1, 9 in the pararectal fat and 1 in the inguinal region. SPECT/CT succeeded to optimize the definition of the CTV and treatment plans in 6/20 patients due to the presence of pararectal SNs located outside the standard treatment volume. 18 F-FCH PET/CT identified abnormal tracer uptake in the iliac LN region in 2/19 patients. These abnormal LNs were negative on SPECT/CT suggesting a potential blockade of lymphatic drainage by metastatic LNs with a high tumour burden. CONCLUSIONS: Multimodality imaging which combines SPECT/CT prostate lymphoscintigraphy and 18 F-FCH PET/CT identified SNs outside standard pelvic CTVs or highly suspicious pelvic LNs in 40% of high-risk prostate cancer patients, highlighting the potential impact of this approach in RT treatment planning.


Assuntos
Colina/farmacologia , Fluordesoxiglucose F18/farmacologia , Imagem Multimodal/métodos , Tomografia por Emissão de Pósitrons , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Tomografia Computadorizada por Raios X , Idoso , Humanos , Processamento de Imagem Assistida por Computador , Linfonodos/patologia , Metástase Linfática/diagnóstico , Metástase Linfática/patologia , Linfocintigrafia/métodos , Masculino , Pessoa de Meia-Idade , Antígeno Prostático Específico/metabolismo , Neoplasias da Próstata/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos
5.
J Magn Reson Imaging ; 24(2): 418-22, 2006 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-16795090

RESUMO

Intracranial stenting is increasingly being used to treat intracranial aneurysms and stenoses. We wanted to assess the utility of magnetic resonance angiography (MRA) in the follow-up of patients treated with various types of intracranial stents and to assess the utility of performing gadolinium-enhanced MRA. A total of 19 patients having undergone intracranial stenting for aneurysms were imaged by MRI at 1.5T. A total of 20 stents were placed in 19 patients. In addition to conventional T2- and diffusion-weighted MRI, 3D time-of-flight MRA was performed before and after contrast administration. In the case of metallic INX stents (N = 7), there was a signal drop at the level of the vessel. which did not allow to evaluating the parent vessel, whereas this was visible in Nitinol stents (N = 8). Additionally a stent with a wire had a small artifact (N = 3). Contrast administration also improved vessel lumen visualization. In the case of Nitinol stents, MRA can be used to reliably demonstrate the vessel lumen after intracranial stenting. The use of postcontrast 3D time-of-flight imaging helps improve the intraluminal definition.


Assuntos
Aneurisma Intracraniano/terapia , Angiografia por Ressonância Magnética/métodos , Stents , Adulto , Idoso , Ligas , Meios de Contraste/administração & dosagem , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Iopamidol/administração & dosagem , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...