Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Eur Respir J ; 2024 Jul 26.
Artigo em Inglês | MEDLINE | ID: mdl-39060016

RESUMO

INTRODUCTION: Pulmonary embolism (PE) is a well-recognised complication of COVID-19 infection, and chronic thromboembolic pulmonary disease with and without pulmonary hypertension (CTEPD/CTEPH) are potential life-limiting consequences. At present the burden of CTEPD/CTEPH is unclear and optimal and cost-effective screening strategies yet to be established. METHODS: We evaluated the CTEPD/CTEPH referral rate to the UK national multidisciplinary team (MDT) during the 2017-2022 period to establish the national incidence of CTEPD/CTEPH potentially attributable to COVID-19-associated PE with historical comparator years. All individual cases of suspected CTEPH were reviewed by the MDT for evidence of associated COVID-19. In a separate multicentre cohort, the risk of developing CTEPH following hospitalisation with COVID-19 was calculated using simple clinical parameters at a median of 5 months post hospital discharge according to existing risk scores using symptoms, ECG and NT pro-BNP. RESULTS: By the second year of the pandemic, CTEPH diagnoses had returned to the pre-pandemic baseline (23.1 versus 27.8 cases per month, p=0.252). Of 334 confirmed CTEPD/CTEPH cases, 4 (1.2%) patients were identified to have CTEPH potentially associated with COVID-19 PE, and a further 3 (0.9%) CTEPD without PH. Of 1094 patients (mean age 58 years, 60.4% male) hospitalised with COVID-19 screened across the UK, 11 (1.0%) were at high risk of CTEPH at follow-up, none of whom had a diagnosis of CTEPH made at the national MDT. CONCLUSION: A-priori risk of developing CTEPH following COVID-19-related hospitalisation is low. Simple risk scoring is a potentially effective way of screening patients for further investigation.

2.
J Hypertens ; 42(9): 1581-1589, 2024 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-38780173

RESUMO

OBJECTIVES: Effects of potassium supplementation on blood pressure (BP) may be offset by an increase in plasma aldosterone. The magnitude of potassium-dependent regulation of aldosterone secretion in humans is not fully characterized; it is not clear whether this is mediated by activation of the renin-angiotensin-aldosterone system (RAAS), as a result of a reduction in BP or other mechanisms. We performed a systematic review and meta-analysis of clinical trials assessing effects of potassium on plasma aldosterone and renin in adult individuals. METHODS: This was carried out in accordance with PRISMA guidelines. Three databases were searched: MEDLINE, EMBASE and CENTRAL. Titles were firstly screened by title and abstract for relevance before full-text articles were assessed for eligibility. The keywords used included "aldosterone", "potassium" and "RAAS". RESULTS: 6395 articles were retrieved and after title/abstract screening, 123 full-text articles were assessed for eligibility. Thirty-six met the prespecified inclusion/exclusion criteria (of which 18/36 also reported systolic BP). Potassium supplementation caused a significant decrease in systolic BP (mean difference [95% CI] -3.69 mmHg [-4.91, -2.46], P  < 0.001) and increase in serum potassium (+0.37 [0.23, 0.52] mmol/l, P  < 0.001). There was an increase in plasma aldosterone (standardized difference 0.426 [0.299, 0.553], P  < 0.001) but not in plasma renin activity. Meta-regression showed a significant positive correlation between change in plasma aldosterone and change in serum potassium ( P  < 0.001). CONCLUSIONS: Potassium supplementation increases plasma aldosterone concentrations, which correlates with the increase in serum potassium concentration which does not appear to be mediated by an increase in plasma renin activity.


Assuntos
Aldosterona , Pressão Sanguínea , Suplementos Nutricionais , Potássio , Humanos , Aldosterona/sangue , Potássio/sangue , Pressão Sanguínea/efeitos dos fármacos , Sistema Renina-Angiotensina/efeitos dos fármacos , Renina/sangue
3.
Eur Heart J Cardiovasc Imaging ; 25(7): 901-911, 2024 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-38597630

RESUMO

AIMS: Hypertensive patients of African ancestry (Afr-a) have higher incidences of heart failure and worse clinical outcomes than hypertensive patients of European ancestry (Eu-a), yet the underlying mechanisms remain misunderstood. This study investigated right (RV) and left (LV) ventricular remodelling alongside myocardial tissue derangements between Afr-a and Eu-a hypertensives. METHODS AND RESULTS: 63 Afr-a and 47 Eu-a hypertensives underwent multi-parametric cardiovascular magnetic resonance. Biventricular volumes, mass, function, mass/end-diastolic volume (M/V) ratios, T2 and pre-/post-contrast T1 relaxation times, synthetic extracellular volume, and myocardial fibrosis (MF) were measured. 3D shape modelling was implemented to delineate ventricular geometry. LV and RV mass (indexed to body-surface-area) and M/V ratio were significantly greater in Afr-a than Eu-a hypertensives (67.1 ± 21.7 vs. 58.3 ± 16.7 g/m2, 12.6 ± 3.48 vs. 10.7 ± 2.71 g/m2, 0.79 ± 0.21 vs. 0.70 ± 0.14 g/mL, and 0.16 ± 0.04 vs. 0.13 ± 0.03 g/mL, respectively; P < 0.03). Afr-a patients showed greater basal interventricular septum thickness than Eu-a patients, influencing LV hypertrophy and RV cavity changes. This biventricular remodelling was associated with prolonged T2 relaxation time (47.0 ± 2.2 vs. 45.7 ± 2.2 ms, P = 0.005) and higher prevalence (23% vs. 4%, P = 0.001) and extent of MF [2.3 (0.6-14.3) vs. 1.6 (0.9-2.5) % LV mass, P = 0.008] in Afr-a patients. Multivariable linear regression showed that modifiable cardiovascular risk factors and greater end-diastolic volume, but not ethnicity, were independently associated with greater LV mass. CONCLUSION: Afr-a hypertensives had distinctive biventricular remodelling, including increased RV mass, septal thickening and myocardial tissue abnormalities compared with Eu-a hypertensives. From this study, modifiable cardiovascular risk factors and ventricular geometry, but not ethnicity, were independently associated with greater LV myocardial mass.


Assuntos
População Negra , Hipertensão , Imagem Cinética por Ressonância Magnética , Remodelação Ventricular , População Branca , Humanos , Masculino , Remodelação Ventricular/fisiologia , Feminino , Pessoa de Meia-Idade , Hipertensão/etnologia , Hipertensão/complicações , Imagem Cinética por Ressonância Magnética/métodos , População Branca/estatística & dados numéricos , População Negra/estatística & dados numéricos , Estudos de Coortes , Idoso , Adulto , Medição de Risco , Miocárdio/patologia , Hipertrofia Ventricular Esquerda/diagnóstico por imagem , Hipertrofia Ventricular Esquerda/etnologia , Hipertrofia Ventricular Esquerda/fisiopatologia
4.
Eur J Heart Fail ; 26(4): 829-840, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38623713

RESUMO

AIMS: Prediction and early detection of heart failure (HF) is crucial to mitigate its impact on quality of life, survival, and healthcare expenditure. Here, we explored the predictive value of serum metabolomics (168 metabolites detected by proton nuclear magnetic resonance [1H-NMR] spectroscopy) for incident HF. METHODS AND RESULTS: Leveraging data of 68 311 individuals and >0.8 million person-years of follow-up from the UK Biobank cohort, we (i) fitted per-metabolite Cox proportional hazards models to assess individual metabolite associations, and (ii) trained and validated elastic net models to predict incident HF using the serum metabolome. We benchmarked discriminative performance against a comprehensive, well-validated clinical risk score (Pooled Cohort Equations to Prevent HF [PCP-HF]). During a median follow-up of ≈12.3 years, several metabolites showed independent association with incident HF (90/168 adjusting for age and sex, 48/168 adjusting for PCP-HF). Performance-optimized risk models effectively retained key predictors representing highly correlated clusters (≈80% feature reduction). Adding metabolomics to PCP-HF improved predictive performance (Harrel's C: 0.768 vs. 0.755, ΔC = 0.013, [95% confidence interval [CI] 0.004-0.022], continuous net reclassification improvement [NRI]: 0.287 [95% CI 0.200-0.367], relative integrated discrimination improvement [IDI]: 17.47% [95% CI 9.463-27.825]). Models including age, sex and metabolomics performed almost as well as PCP-HF (Harrel's C: 0.745 vs. 0.755, ΔC = 0.010 [95% CI -0.004 to 0.027], continuous NRI: 0.097 [95% CI -0.025 to 0.217], relative IDI: 13.445% [95% CI -10.608 to 41.454]). Risk and survival stratification was improved by integrating metabolomics. CONCLUSION: Serum metabolomics improves incident HF risk prediction over PCP-HF. Scores based on age, sex and metabolomics exhibit similar predictive power to clinically-based models, potentially offering a cost-effective, standardizable, and scalable single-domain alternative.


Assuntos
Insuficiência Cardíaca , Metabolômica , Humanos , Insuficiência Cardíaca/sangue , Insuficiência Cardíaca/epidemiologia , Feminino , Masculino , Metabolômica/métodos , Medição de Risco/métodos , Pessoa de Meia-Idade , Incidência , Idoso , Biomarcadores/sangue , Reino Unido/epidemiologia , Seguimentos , Valor Preditivo dos Testes
5.
Blood Press Monit ; 29(4): 203-206, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38502042

RESUMO

OBJECTIVE: To report a validation of the Riester Big Ben Square Desk Aneroid Sphygmomanometer according to the international protocol developed by the Working Group on Blood Pressure Monitoring of the European Society of Hypertension 2002 (ESH-IP 2002) in the interest of transparency. This legacy publication is intended to assure users that the device satisfied the requirements in place at that time. METHODS: Performance of the device was assessed by participants' age, sex, arm circumference and entry SBP/DBP. Validation was performed in 33 participants. The sphygmomanometer was assessed according to the ESH-IP, which defines zones of accuracy compared to the mercury standard as ≤5, ≤10, ≤15 mmHg or more. RESULTS: The mean (± SD) age was 50.5 ±â€…13.0 years, range 29-71 years, entry SBP 142.6 ±â€…23.7 mmHg, entry DBP 89.0 ±â€…17.8 mmHg. The device passed all the requirements listed and the validation protocol. The Riester Big Ben Square Desk aneroid sphygmomanometer slightly underestimated the observer-measured SBP, yet slightly overestimated DBP. The observer-device disagreement was -0.8 ±â€…6.4 mmHg SBP and +0.6 ±â€…4.0 mmHg DBP. CONCLUSION: These data show that the Riester Big Ben Square Desk aneroid sphygmomanometer fulfilled the ESH-IP 2002 requirements for the validation of BP monitors. It was on this basis that the British and Irish Hypertension Society recommended it for clinical use in the adult population.


Assuntos
Determinação da Pressão Arterial , Humanos , Pessoa de Meia-Idade , Masculino , Adulto , Feminino , Idoso , Determinação da Pressão Arterial/instrumentação , Esfigmomanômetros/normas , Hipertensão/diagnóstico , Hipertensão/fisiopatologia , Pressão Sanguínea
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA