J Shoulder Elbow Surg ; 33(4): 872-879, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37689103

RESUMO

BACKGROUND: Current methods available for assessment of radiolucency and in-between fin (IBF) growth of a glenoid component have not undergone interobserver reliability testing for an all-polyethylene fluted central peg (FCP) glenoid. The purpose of this study was to evaluate anteroposterior radiographs of an FCP glenoid component at ≥48 months comparing commonly used scales to a new method adapted to the FCP. Our hypothesis was that the new method would result in acceptable intra- and interobserver agreement and a more accurate description of radiographic findings. METHODS: We reviewed ≥48-month follow-up radiographs of patients treated with a primary aTSA using an FCP glenoid. Eighty-three patients were included in the review. Radiographs were evaluated by 5 reviewers using novel IBF radiodensity and radiolucency assessments and the Wirth and Lazarus methods. To assess intraobserver reliability, a subset of 40 images was reviewed. Kappa statistics were calculated to determine intra- and interobserver reliability; correlations were assessed using Pearson correlation. RESULTS: Interobserver agreement (κ score) was as follows: IBF 0.71, radiolucency 0.68, Wirth 0.48, and Lazarus 0.22. Intraobserver agreement ranges were as follows: IBF radiodensity 0.36-0.67, radiolucency 0.55-0.62, Wirth 0.11-0.73, and Lazarus 0.04-0.46. Correlation analysis revealed the following: IBF to Wirth r = 0.93, radiolucency to Lazarus r = 0.92 (P value <.001 for all). CONCLUSION: This study introduces a radiographic assessment method developed specifically for an FCP glenoid component. Results show high interobserver and acceptable intraobserver reliability for the method presented in this study. The new scales provide a more accurate description of radiographic findings, helping to identify glenoid components that may be at risk for loosening.


Assuntos
Artroplastia do Ombro , Artroplastia de Substituição , Cavidade Glenoide , Prótese Articular , Articulação do Ombro , Humanos , Polietileno , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/cirurgia , Artroplastia de Substituição/métodos , Reprodutibilidade dos Testes , Seguimentos , Resultado do Tratamento , Desenho de Prótese , Cavidade Glenoide/diagnóstico por imagem , Cavidade Glenoide/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...